-
1
-
-
50549156477
-
Arthroplasty of the hip; A new operation
-
J. Charnley Arthroplasty of the hip; a new operation Lancet 27 1961 1129 1132
-
(1961)
Lancet
, vol.27
, pp. 1129-1132
-
-
Charnley, J.1
-
2
-
-
0020533173
-
Uncemented acetabular replacement
-
P.A. Ring Uncemented acetabular replacement Arch Orthop Trauma Surg 101 1983 225 229
-
(1983)
Arch Orthop Trauma Surg
, vol.101
, pp. 225-229
-
-
Ring, P.A.1
-
3
-
-
0015977514
-
Zementlose Verankerung von Endoprothesen nach dem Tragrippenprinzip
-
H. Mittelmeier Zementlose Verankerung von Endoprothesen nach dem Tragrippenprinzip Z Orthop Ihre Grenzgeb 112 1974 27 33
-
(1974)
Z Orthop Ihre Grenzgeb
, vol.112
, pp. 27-33
-
-
Mittelmeier, H.1
-
5
-
-
0013912485
-
Replacement of arthritic hips by the McKee-Farrar prosthesis
-
G.K. McKee, and J. Watson-Farrar Replacement of arthritic hips by the McKee-Farrar prosthesis J Bone Joint Surg 48B 1966 245 259
-
(1966)
J Bone Joint Surg
, vol.48
, pp. 245-259
-
-
McKee, G.K.1
Watson-Farrar, J.2
-
6
-
-
0025308746
-
Cementless uncoated polyethylene acetabular components in total hip replacement. Review of five- to 10-year results
-
J. Wilson-MacDonald, E.W. Morscher, and Z. Masar Cementless uncoated polyethylene acetabular components in total hip replacement. Review of five- to 10-year results J Bone Joint Surg 72B 1990 423 430
-
(1990)
J Bone Joint Surg
, vol.72
, pp. 423-430
-
-
Wilson-Macdonald, J.1
Morscher, E.W.2
Masar, Z.3
-
7
-
-
0008721363
-
Current state of cementless fixation of endoprosthesis
-
E. Morscher Current state of cementless fixation of endoprosthesis Swiss Med 9 1987 27 44
-
(1987)
Swiss Med
, vol.9
, pp. 27-44
-
-
Morscher, E.1
-
8
-
-
0024956607
-
Cementless press-fit cup. Principles, experimental data, and three-year follow-up study
-
E.W. Morscher, H. Bereiter, and C. Lampert Cementless press-fit cup. Principles, experimental data, and three-year follow-up study Clin Orthop 249 1989 12 20
-
(1989)
Clin Orthop
, vol.249
, pp. 12-20
-
-
Morscher, E.W.1
Bereiter, H.2
Lampert, C.3
-
9
-
-
0030841384
-
Rationale of a flexible press fit cup in total hip replacement. 5-year follow-up in 280 procedures
-
E.W. Morscher, B. Berli, W. Jockers, and R. Schenk Rationale of a flexible press fit cup in total hip replacement. 5-year follow-up in 280 procedures Clin Orthop 341 1997 42 50
-
(1997)
Clin Orthop
, vol.341
, pp. 42-50
-
-
Morscher, E.W.1
Berli, B.2
Jockers, W.3
Schenk, R.4
-
10
-
-
0026527960
-
Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. a 12-year radiographic review
-
R.L. Barrack, R.D. Mulroy Jr, and W.H. Harris Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review J Bone Joint Surg 74B 1992 385 389
-
(1992)
J Bone Joint Surg
, vol.74
, pp. 385-389
-
-
Barrack, R.L.1
Mulroy Jr., R.D.2
Harris, W.H.3
-
11
-
-
0025161599
-
The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review
-
R.D. Mulroy Jr, and W.H. Harris The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic review J Bone Joint Surg 72B 1990 757 760
-
(1990)
J Bone Joint Surg
, vol.72
, pp. 757-760
-
-
Mulroy Jr., R.D.1
Harris, W.H.2
-
12
-
-
0022360572
-
Verlaufsbeobachtung von Hüftendoprothesen nach Abschluss realer Belastungsbedingungen von 10 Jahren
-
H.W. Buchholz, K. Heinert, and M. Wargenau Verlaufsbeobachtung von Hüftendoprothesen nach Abschluss realer Belastungsbedingungen von 10 Jahren Z Orthop Ihre Grenzgeb 123 1985 815 820
-
(1985)
Z Orthop Ihre Grenzgeb
, vol.123
, pp. 815-820
-
-
Buchholz, H.W.1
Heinert, K.2
Wargenau, M.3
-
13
-
-
0020534033
-
Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty
-
E.W. Morscher, and A. Schmassmann Failures of total hip arthroplasty and probable incidence of revision surgery in the future. Calculations according to a mathematical model based on a ten years' experience in total hip arthroplasty Arch Orthop Trauma Surg 101 1983 137 143
-
(1983)
Arch Orthop Trauma Surg
, vol.101
, pp. 137-143
-
-
Morscher, E.W.1
Schmassmann, A.2
-
14
-
-
0024789770
-
Comparison between straight- and curved-stem Muller femoral prostheses. 5- to 10-year results of 545 total hip replacements
-
J. Wilson-MacDonald, and E. Morscher Comparison between straight- and curved-stem Muller femoral prostheses. 5- to 10-year results of 545 total hip replacements Arch Orthop Trauma Surg 109 1990 14 20
-
(1990)
Arch Orthop Trauma Surg
, vol.109
, pp. 14-20
-
-
Wilson-Macdonald, J.1
Morscher, E.2
-
15
-
-
0026662669
-
Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
-
T.P. Schmalzried, M. Jasty, and W.H. Harris Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space J Bone Joint Surg 74A 1992 849 863
-
(1992)
J Bone Joint Surg
, vol.74
, pp. 849-863
-
-
Schmalzried, T.P.1
Jasty, M.2
Harris, W.H.3
-
16
-
-
4244062902
-
Cementless implantation of a modified M.E. Müller straight-stem endoprosthesis
-
E.W. Morscher Springer Berlin, Heidelberg, New York
-
D. Parpan, and R. Ganz Cementless implantation of a modified M.E. Müller straight-stem endoprosthesis E.W. Morscher The cementless fixation of hip endoprosthesis 1984 Springer Berlin, Heidelberg, New York 156 167
-
(1984)
The Cementless Fixation of Hip Endoprosthesis
, pp. 156-167
-
-
Parpan, D.1
Ganz, R.2
-
17
-
-
0027076231
-
Clinical and radiographic results of the Muller straight stem used as a press-fit
-
I. Stockley, L. McLean, and A.E. Gross Clinical and radiographic results of the Muller straight stem used as a press-fit J Arthroplasty 7 1992 477 482
-
(1992)
J Arthroplasty
, vol.7
, pp. 477-482
-
-
Stockley, I.1
McLean, L.2
Gross, A.E.3
-
18
-
-
0034951153
-
Effect of femoral component offset on polyethylene wear in total hip arthroplasty
-
D.P. Sakalkale, P.F. Sharkey, K. Eng, W.J. Hozack, and R.H. Rothman Effect of femoral component offset on polyethylene wear in total hip arthroplasty Clin Orthop 388 2001 125 134
-
(2001)
Clin Orthop
, vol.388
, pp. 125-134
-
-
Sakalkale, D.P.1
Sharkey, P.F.2
Eng, K.3
Hozack, W.J.4
Rothman, R.H.5
-
19
-
-
0344472834
-
The bone cement cuff in hip endoprosthesis: Results of 80 postmortem studies
-
E. Morscher Springer Berlin, Heidelberg, New York, Tokyo
-
A. Gächter The bone cement cuff in hip endoprosthesis: results of 80 postmortem studies E. Morscher The cementless fixation of hip endoprosthesis 1984 Springer Berlin, Heidelberg, New York, Tokyo 11 16
-
(1984)
The Cementless Fixation of Hip Endoprosthesis
, pp. 11-16
-
-
Gächter, A.1
-
20
-
-
0019249787
-
Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures
-
R. Huiskes Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures Acta Orthop Scand Suppl 185 1980 1 208
-
(1980)
Acta Orthop Scand Suppl
, vol.185
, pp. 1-208
-
-
Huiskes, R.1
-
21
-
-
0018375440
-
An investigation of the effect of cement thickness on an implant by finite element stress analysis
-
B.M. Kwak, O.K. Lim, Y.Y. Kim, and K. Rim An investigation of the effect of cement thickness on an implant by finite element stress analysis Int Orthop 2 1979 315 319
-
(1979)
Int Orthop
, vol.2
, pp. 315-319
-
-
Kwak, B.M.1
Lim, O.K.2
Kim, Y.Y.3
Rim, K.4
-
22
-
-
0025147719
-
Histomorphological studies of the long-term skeletal responses to well fixed cemented femoral components
-
M. Jasty, W.J. Maloney, C.R. Bragdon, T. Haire, and W.H. Harris Histomorphological studies of the long-term skeletal responses to well fixed cemented femoral components J Bone Joint Surg 72A 1990 1220 1229
-
(1990)
J Bone Joint Surg
, vol.72
, pp. 1220-1229
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
Haire, T.4
Harris, W.H.5
-
23
-
-
0028214666
-
The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results
-
E. Ebramzadeh, A. Sarmiento, H.A. McKellop, A. Llinas, and W. Gogan The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results J Bone Joint Surg 76A 1994 77 87
-
(1994)
J Bone Joint Surg
, vol.76
, pp. 77-87
-
-
Ebramzadeh, E.1
Sarmiento, A.2
McKellop, H.A.3
Llinas, A.4
Gogan, W.5
-
24
-
-
0019957225
-
Femoral component loosening using contemporary techniques of femoral cement fixation
-
W.H. Harris, J.C. McCarthy Jr, and D.A. O'Neill Femoral component loosening using contemporary techniques of femoral cement fixation J Bone Joint Surg 64A 1982 1063 1067
-
(1982)
J Bone Joint Surg
, vol.64
, pp. 1063-1067
-
-
Harris, W.H.1
McCarthy Jr., J.C.2
O'Neill, D.A.3
-
25
-
-
0033025224
-
Status of cementation technique in total hip endoprostheses in Germany
-
S.J. Breusch, R. Berghof, U. Schneider, G. Weiss, H.G. Simank, and M. Lukoschek Status of cementation technique in total hip endoprostheses in Germany Z Orthop Ihre Grenzgeb 137 1999 101 107
-
(1999)
Z Orthop Ihre Grenzgeb
, vol.137
, pp. 101-107
-
-
Breusch, S.J.1
Berghof, R.2
Schneider, U.3
Weiss, G.4
Simank, H.G.5
Lukoschek, M.6
-
26
-
-
0034901376
-
Current cementing techniques in hip hemi-arthroplasty
-
S. Scott, A.W. McCaskie, S.J. Calder, C. Wildin, and P.J. Gregg Current cementing techniques in hip hemi-arthroplasty Injury 32 2001 461 464
-
(2001)
Injury
, vol.32
, pp. 461-464
-
-
Scott, S.1
McCaskie, A.W.2
Calder, S.J.3
Wildin, C.4
Gregg, P.J.5
-
27
-
-
0004208853
-
-
Springer Berlin, Heidelberg, New York
-
E.W. Morscher Endoprosthetics 1995 Springer Berlin, Heidelberg, New York
-
(1995)
Endoprosthetics
-
-
Morscher, E.W.1
-
28
-
-
0037837128
-
The cemented MS-30 stem in total hip replacement, matte versus polished surface: Minimum of five years of clinical and radiographic results of a prospective study
-
G.L. Winters M.J. Nutt ASTM International West Conshohocken (PA)
-
B. Berli, R. Elke, and E.W. Morscher The cemented MS-30 stem in total hip replacement, matte versus polished surface: minimum of five years of clinical and radiographic results of a prospective study G.L. Winters M.J. Nutt Stainless steels for medical and surgical applications. (ASTM Meeting, Pittsburgh, PA, May 2002) 2003 ASTM International West Conshohocken (PA) 249 261
-
(2003)
Stainless Steels for Medical and Surgical Applications. (ASTM Meeting, Pittsburgh, PA, May 2002)
, pp. 249-261
-
-
Berli, B.1
Elke, R.2
Morscher, E.W.3
-
29
-
-
0023681017
-
Experience with the Exeter total hip replacement since 1970
-
J.L. Fowler, G.A. Gie, A.J. Lee, and R.S. Ling Experience with the Exeter total hip replacement since 1970 Orthop Clin N Am 19 1988 477 489
-
(1988)
Orthop Clin N Am
, vol.19
, pp. 477-489
-
-
Fowler, J.L.1
Gie, G.A.2
Lee, A.J.3
Ling, R.S.4
-
30
-
-
0031828375
-
Loosening of matte and polished cemented femoral stems
-
D.W. Howie, R.G. Middleton, and K. Costi Loosening of matte and polished cemented femoral stems J Bone Joint Surg 80B 1998 573 576
-
(1998)
J Bone Joint Surg
, vol.80
, pp. 573-576
-
-
Howie, D.W.1
Middleton, R.G.2
Costi, K.3
-
32
-
-
0031864067
-
Analyse actuarielle à 10 ans d'une cohorte de 156 prothèses totales de hanche cimentées à couple de frottement alumine/poly-ethylène
-
S. LeMouel, J. Allain, and D. Goutallier Analyse actuarielle à 10 ans d'une cohorte de 156 prothèses totales de hanche cimentées à couple de frottement alumine/poly-ethylène Rev Chir Orthop 84 1998 338 345
-
(1998)
Rev Chir Orthop
, vol.84
, pp. 338-345
-
-
Lemouel, S.1
Allain, J.2
Goutallier, D.3
-
33
-
-
0001314078
-
Cemented and non-cemented hip arthroplasty with a proximal plasma sprayed titanium stem
-
C. Van der Straeten, M. Goossens, and T.A. Gruen Cemented and non-cemented hip arthroplasty with a proximal plasma sprayed titanium stem J Bone Joint Surg 81B Suppl II 1999 173
-
(1999)
J Bone Joint Surg
, vol.81
, Issue.2
, pp. 173
-
-
Van Der Straeten, C.1
Goossens, M.2
Gruen, T.A.3
-
34
-
-
0030972295
-
Low loosening rate of a cemented titanium straight shaft prosthesis in long-term follow-up
-
C. Eingartner, R. Volkmann, K. Kummel, and S. Weller Low loosening rate of a cemented titanium straight shaft prosthesis in long-term follow-up Swiss Surg 3 1997 49 54
-
(1997)
Swiss Surg
, vol.3
, pp. 49-54
-
-
Eingartner, C.1
Volkmann, R.2
Kummel, K.3
Weller, S.4
-
35
-
-
0034915640
-
Nine-year results of Mülller cemented titanium straight stems in total hip replacement
-
Y.P. Acklin, B.J. Berli, W. Frick, R. Elke, and E.W. Morscher Nine-year results of Mülller cemented titanium straight stems in total hip replacement Arch Orthop Trauma Surg 121 2001 391 398
-
(2001)
Arch Orthop Trauma Surg
, vol.121
, pp. 391-398
-
-
Acklin, Y.P.1
Berli, B.J.2
Frick, W.3
Elke, R.4
Morscher, E.W.5
-
36
-
-
0033851948
-
The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties
-
L.I. Havelin, L.B. Engesaeter, B. Espehaug, O. Furnes, S.A. Lie, and S.E. Vollset The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties Acta Orthop Scand 71 2000 337 353
-
(2000)
Acta Orthop Scand
, vol.71
, pp. 337-353
-
-
Havelin, L.I.1
Engesaeter, L.B.2
Espehaug, B.3
Furnes, O.4
Lie, S.A.5
Vollset, S.E.6
-
37
-
-
0028857458
-
Early aseptic loosening of uncemented femoral components in primary total hip replacement. a review based on the Norwegian Arthroplasty Register
-
L.I. Havelin, B. Espehaug, S.E. Vollset, and L.B. Engesaeter Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register J Bone Joint Surg 77B 1995 11 17
-
(1995)
J Bone Joint Surg
, vol.77
, pp. 11-17
-
-
Havelin, L.I.1
Espehaug, B.2
Vollset, S.E.3
Engesaeter, L.B.4
-
38
-
-
0008667386
-
Swedish hip registry: Results with 20-year follow up with validation clinically and radiographically
-
Orlando, FL, March 15-19
-
Malchau H., Sodermann P., Herberts P. Swedish hip registry: results with 20-year follow up with validation clinically and radiographically. Presented at the 67th Annual Meeting of the American Academy of Orthopaedic Surgeons, Orlando, FL, March 15-19, 2000
-
(2000)
67th Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Malchau, H.1
Sodermann, P.2
Herberts, P.3
-
39
-
-
0034033672
-
Aseptic loosening of Boneloc cemented Exeter total hip replacement. a 5 year follow-up of the first 100 hips
-
P.B. Thomsen, S. Bøvling, B. Jacoby, and T.B. Hansen Aseptic loosening of Boneloc cemented Exeter total hip replacement. A 5 year follow-up of the first 100 hips Hip Intl 10 2000 102 107
-
(2000)
Hip Intl
, vol.10
, pp. 102-107
-
-
Thomsen, P.B.1
Bøvling, S.2
Jacoby, B.3
Hansen, T.B.4
-
40
-
-
0036200705
-
Current state of cement fixation in THR
-
E.W. Morscher, and D. Wirz Current state of cement fixation in THR Acta Orthop Belg 68 1 2002 1 12
-
(2002)
Acta Orthop Belg
, vol.68
, Issue.1
, pp. 1-12
-
-
Morscher, E.W.1
Wirz, D.2
-
42
-
-
0038513570
-
Results of in vitro studies about the mechanism of wear in the stem-cement interface of THR
-
G.L. Winters M.J. Nutt ASTM International West Conshohocken, PA
-
D. Wirz, B. Zurfluh, B. Göpfert, F. Li, W. Frick, and E.W. Morscher Results of in vitro studies about the mechanism of wear in the stem-cement interface of THR G.L. Winters M.J. Nutt Stainless steels for medical and surgical applications 2002 ASTM International West Conshohocken, PA 222 234
-
(2002)
Stainless Steels for Medical and Surgical Applications
, pp. 222-234
-
-
Wirz, D.1
Zurfluh, B.2
Göpfert, B.3
Li, F.4
Frick, W.5
Morscher, E.W.6
-
44
-
-
0037773104
-
Schwingverschleiss von Titan gegen Knochen verursacht Abriebpartikel kleiner als Zellgrösse
-
K.H. Zum Gahr DGM Verlag Oberursel
-
M.A. Wimmer, R. Nassutt, A. Lersner, J. Kunze, and E. Schneider Schwingverschleiss von Titan gegen Knochen verursacht Abriebpartikel kleiner als Zellgrösse K.H. Zum Gahr Reibung und Verschleiss 1996 DGM Verlag Oberursel
-
(1996)
Reibung und Verschleiss
-
-
Wimmer, M.A.1
Nassutt, R.2
Lersner, A.3
Kunze, J.4
Schneider, E.5
-
45
-
-
0038449860
-
Fretting wear of titanium and cobalt-chromium alloys against bone cement
-
New Orleans, LA, Mar 16-22
-
Wimmer M.A., Schneider E. Fretting wear of titanium and cobalt-chromium alloys against bone cement. Annual Meeting of the Orthopedic Research Society, New Orleans, LA, Mar 16-22, 1998
-
(1998)
Annual Meeting of the Orthopedic Research Society
-
-
Wimmer, M.A.1
Schneider, E.2
-
46
-
-
0038449861
-
Fretting wear of titanium against bone-cement depends on the surface finish of titanium
-
Amsterdam, The Netherlands
-
Wimmer M.A., Bluhm A., Hansen I., Heckel L., Schneider E. Fretting wear of titanium against bone-cement depends on the surface finish of titanium. Annual Meeting of the European Orthopedic Research Society, Amsterdam, The Netherlands, 1998
-
(1998)
Annual Meeting of the European Orthopedic Research Society
-
-
Wimmer, M.A.1
Bluhm, A.2
Hansen, I.3
Heckel, L.4
Schneider, E.5
-
47
-
-
0033628937
-
Biological reactions to wear debris in total joint replacement
-
E. Ingham, and J. Fisher Biological reactions to wear debris in total joint replacement Proc Inst Mech Eng 214 1 2000 21 37
-
(2000)
Proc Inst Mech Eng
, vol.214
, Issue.1
, pp. 21-37
-
-
Ingham, E.1
Fisher, J.2
-
49
-
-
0033332224
-
Fretting corrosion of materials for orthopaedic implants: A study of a metal/polymer contact in an artificial physiological medium
-
B. Tritschler, B. Forest, and J. Rieu Fretting corrosion of materials for orthopaedic implants: a study of a metal/polymer contact in an artificial physiological medium Tribol Int 32 1999 587 596
-
(1999)
Tribol Int
, vol.32
, pp. 587-596
-
-
Tritschler, B.1
Forest, B.2
Rieu, J.3
-
50
-
-
0024675934
-
An analysis of changes in the surfaces of metallic femoral components in hip prostheses: A study of 60 prostheses removed after 1-20 years
-
U.E. Pazzaglia, L. Pedrotti, R. Ramella, and G. Zatti An analysis of changes in the surfaces of metallic femoral components in hip prostheses: a study of 60 prostheses removed after 1-20 years Ital Orthop Traumatol 15 1998 221
-
(1998)
Ital Orthop Traumatol
, vol.15
, pp. 221
-
-
Pazzaglia, U.E.1
Pedrotti, L.2
Ramella, R.3
Zatti, G.4
-
51
-
-
0030453223
-
Crevice corrosion of cemented titanium alloy stems in total hip replacements
-
H.G. Willert, L.G. Broback, G.H. Buchhorn, P.H. Jensen, G. Koster, and I. Lang Crevice corrosion of cemented titanium alloy stems in total hip replacements Clin Orthop Rel Res 333 1996 51 75
-
(1996)
Clin Orthop Rel Res
, vol.333
, pp. 51-75
-
-
Willert, H.G.1
Broback, L.G.2
Buchhorn, G.H.3
Jensen, P.H.4
Koster, G.5
Lang, I.6
-
53
-
-
0142097416
-
Use of isothermal heat-conduction microcalorimetry (IHCMC) for the evaluation of synthetic biomaterials
-
G. Lewis, and A.U. Daniels Use of isothermal heat-conduction microcalorimetry (IHCMC) for the evaluation of synthetic biomaterials J Biomed Mater Res 66B 2003 487 501
-
(2003)
J Biomed Mater Res
, vol.66
, pp. 487-501
-
-
Lewis, G.1
Daniels, A.U.2
-
54
-
-
0037210094
-
Isothermal microcalorimetry: An analytical technique for assessing the dynamic chemical stability of UHMWPE
-
S.J. Charlebois, A.U. Daniels, and G. Lewis Isothermal microcalorimetry: an analytical technique for assessing the dynamic chemical stability of UHMWPE Biomaterials 24 2003 291 296
-
(2003)
Biomaterials
, vol.24
, pp. 291-296
-
-
Charlebois, S.J.1
Daniels, A.U.2
Lewis, G.3
|