메뉴 건너뛰기




Volumn 405, Issue , 2002, Pages 70-78

Analysis of long-term cemented total hip arthroplasty retrievals

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT; METAL; POLYETHYLENE;

EID: 0036908878     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-200212000-00009     Document Type: Conference Paper
Times cited : (71)

References (37)
  • 1
    • 0025047558 scopus 로고
    • Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties
    • Anthony PP, Gie GA, Howie CR, Ling RM: Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg 72B:971-979, 1991.
    • (1991) J Bone Joint Surg , vol.72 B , pp. 971-979
    • Anthony, P.P.1    Gie, G.A.2    Howie, C.R.3    Ling, R.M.4
  • 2
    • 0000259728 scopus 로고
    • Experimental strain-analysis in the femoral cement mantel of simulated total hip arthroplasties
    • Burke DW, Davies JP, O'Connor DO, Harris WH: Experimental strain-analysis in the femoral cement mantel of simulated total hip arthroplasties. Orthop Trans 9:296, 1984.
    • (1984) Orthop Trans , vol.9 , pp. 296
    • Burke, D.W.1    Davies, J.P.2    O'Connor, D.O.3    Harris, W.H.4
  • 6
    • 0023892038 scopus 로고
    • Radiographic changes in bone dimensions in asymptomatic cemented total hip arthroplastie
    • Comadoll JL, Sherman RE, Gustilo RB, Bechtold JE: Radiographic changes in bone dimensions in asymptomatic cemented total hip arthroplastie. J Bone Joint Surg 70A:433-438, 1988.
    • (1988) J Bone Joint Surg , vol.70 A , pp. 433-438
    • Comadoll, J.L.1    Sherman, R.E.2    Gustilo, R.B.3    Bechtold, J.E.4
  • 9
    • 0020826227 scopus 로고
    • Cement strain measurement surrounding loose and well-fixed femoral component stems
    • Crowninshield RD, Tolbert JR: Cement strain measurement surrounding loose and well-fixed femoral component stems. J Biomed Mater Res 17:819-828, 1983.
    • (1983) J Biomed Mater Res , vol.17 , pp. 819-828
    • Crowninshield, R.D.1    Tolbert, J.R.2
  • 10
    • 0019764242 scopus 로고
    • Histomorphology of the bone-to-cement interface. Remodeling of the cortex and revascularization of the medullary canal in animal experiments
    • Salvati EA (ed). St Louis, CV Mosby
    • Draenert K: Histomorphology of the Bone-to-Cement Interface. Remodeling of the Cortex and Revascularization of the Medullary Canal in Animal Experiments. In Salvati EA (ed). In The Hip: Proceedings of the Ninth Open Scientific Meeting of the Hip Society. St Louis, CV Mosby 71-110, 1981.
    • (1981) In The Hip: Proceedings of the Ninth Open Scientific Meeting of the Hip Society , pp. 71-110
    • Draenert, K.1
  • 11
    • 0026465249 scopus 로고
    • In vitro study of initial stability of a conical collared component
    • Fischer KJ, Carter DR, Maloney WJ: In vitro study of initial stability of a conical collared component. J Arthroplasty 7:389-395, 1992.
    • (1992) J Arthroplasty , vol.7 , pp. 389-395
    • Fischer, K.J.1    Carter, D.R.2    Maloney, W.J.3
  • 12
    • 0017154560 scopus 로고
    • The femoral stem/cement interface in total hip replacement
    • Fornaiser VL, Cameron HU: The femoral stem/cement interface in total hip replacement. Clin Orthop 116:248-252, 1976.
    • (1976) Clin Orthop , vol.116 , pp. 248-252
    • Fornaiser, V.L.1    Cameron, H.U.2
  • 13
    • 0026070354 scopus 로고
    • A three-dimensional nonlinear finite element study of the effect of cementprosthesis debonding in cemented femoral total hip components
    • Harrigan TP, Harris WH: A three-dimensional nonlinear finite element study of the effect of cementprosthesis debonding in cemented femoral total hip components. J Biomech 24:1047-1058, 1991.
    • (1991) J Biomech , vol.24 , pp. 1047-1058
    • Harrigan, T.P.1    Harris, W.H.2
  • 14
    • 0023908985 scopus 로고
    • The correlation between roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties
    • Hodgkinson JP, Shelley P, Wroblewski BM: The correlation between roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 228:105-109, 1988.
    • (1988) Clin Orthop , vol.228 , pp. 105-109
    • Hodgkinson, J.P.1    Shelley, P.2    Wroblewski, B.M.3
  • 15
    • 0024720110 scopus 로고
    • Endosteal bone loss after total hip arthroplasty
    • Hoffman AA, Wyatt B, France EP, et al: Endosteal bone loss after total hip arthroplasty. Clin Orthop 245:138-144, 1989.
    • (1989) Clin Orthop , vol.245 , pp. 138-144
    • Hoffman, A.A.1    Wyatt, B.2    France, E.P.3
  • 16
    • 0003104060 scopus 로고
    • Stress patterns, failure modes, and bone remodeling
    • Fitzgerald Jr RH (ed). New York, Raven Press
    • Huiskes R: Stress Patterns, Failure Modes, and Bone Remodeling. In Fitzgerald Jr RH (ed). Non-Cemented Total Hip Arthroplasty. New York, Raven Press 283-302, 1988.
    • (1988) Non-Cemented Total Hip Arthroplasty , pp. 283-302
    • Huiskes, R.1
  • 17
    • 0025784682 scopus 로고
    • The initiation of failure in cemented femoral components of hip arthroplasties
    • Jasty M, Maloney WJ, Bragdon CR, et al: The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg 73B:551-558, 1991.
    • (1991) J Bone Joint Surg , vol.73 B , pp. 551-558
    • Jasty, M.1    Maloney, W.J.2    Bragdon, C.R.3
  • 18
    • 0025147719 scopus 로고
    • Histomorphological studies of the long-term skeletal responses to well-fixed cemented femoral component
    • Jasty M, Maloney WJ, Bragdon CR, Harie T, Harris WH: Histomorphological studies of the long-term skeletal responses to well-fixed cemented femoral component. J Bone Joint Surg 72A: 1220-1229, 1990.
    • (1990) J Bone Joint Surg , vol.72 A , pp. 1220-1229
    • Jasty, M.1    Maloney, W.J.2    Bragdon, C.R.3    Harie, T.4    Harris, W.H.5
  • 19
    • 0031792614 scopus 로고    scopus 로고
    • Importance of a thin cement mantle: Autopsy studies of eight hips: Autopsy studies
    • Kawate K, Maloney WJ, Bragdon CA, et al: Importance of a thin cement mantle: Autopsy studies of eight hips: Autopsy studies. Clin Orthop 355:70-76, 1998.
    • (1998) Clin Orthop , vol.355 , pp. 70-76
    • Kawate, K.1    Maloney, W.J.2    Bragdon, C.A.3
  • 21
    • 0021359644 scopus 로고
    • The influence of prosthetic stem stiffness and of a collar on stresses in the proximal endof a femur with a cemented femoral component
    • Lewis JL, Askew MJ, Wixson RL, Kramer GM, Tarr RR: The influence of prosthetic stem stiffness and of a collar on stresses in the proximal endof a femur with a cemented femoral component. J Bone Joint Surg 66A:280-286, 1984.
    • (1984) J Bone Joint Surg , vol.66 A , pp. 280-286
    • Lewis, J.L.1    Askew, M.J.2    Wixson, R.L.3    Kramer, G.M.4    Tarr, R.R.5
  • 22
    • 0024954244 scopus 로고
    • Biochemical and histological investigation of cemented total hip arthroplasties: A study of autopsy-retrieved femurs after in vitro cycling
    • Maloney WJ, Jasty M, Burke DW, et al: Biochemical and histological investigation of cemented total hip arthroplasties: A study of autopsy-retrieved femurs after in vitro cycling. Clin Orthop 249:129-140, 1989.
    • (1989) Clin Orthop , vol.249 , pp. 129-140
    • Maloney, W.J.1    Jasty, M.2    Burke, D.W.3
  • 25
    • 0030339451 scopus 로고    scopus 로고
    • Skeletal response to well-fixed femoral components inserted with and without cement
    • Maloney WJ, Sychterz C, Bradgon C, et al: Skeletal response to well-fixed femoral components inserted with and without cement. Clin Orthop 333:15-26, 1996.
    • (1996) Clin Orthop , vol.333 , pp. 15-26
    • Maloney, W.J.1    Sychterz, C.2    Bradgon, C.3
  • 26
    • 0014746120 scopus 로고
    • Abduction forces in the one-legged stance
    • McCleish RD, Chamley J: Abduction forces in the one-legged stance. J Biomech 3:191-209, 1970.
    • (1970) J Biomech , vol.3 , pp. 191-209
    • McCleish, R.D.1    Chamley, J.2
  • 27
    • 0021718314 scopus 로고
    • Instability of total hip prosthesis at rotational stress
    • Mjoberg B, Hansson LI, Selvik G: Instability of total hip prosthesis at rotational stress. Acta Orthop Scand 55:504-506, 1984.
    • (1984) Acta Orthop Scand , vol.55 , pp. 504-506
    • Mjoberg, B.1    Hansson, L.I.2    Selvik, G.3
  • 28
    • 0017837076 scopus 로고
    • Proximal strain distribution in the loaded femur: An in vitro comparison of the distributions in the intact femur and after insertion of different hip replacement femoral components
    • Oh I, Harris WH: Proximal strain distribution in the loaded femur: An in vitro comparison of the distributions in the intact femur and after insertion of different hip replacement femoral components. J Bone Joint Surg 60A:75-85, 1978.
    • (1978) J Bone Joint Surg , vol.60 A , pp. 75-85
    • Oh, I.1    Harris, W.H.2
  • 29
    • 0023555193 scopus 로고
    • Femoral expansion in total hip arthroplasty
    • Poss R, Staehlin P, Larson M: Femoral expansion in total hip arthroplasty. J Arthroplasty 2:259-264, 1987.
    • (1987) J Arthroplasty , vol.2 , pp. 259-264
    • Poss, R.1    Staehlin, P.2    Larson, M.3
  • 30
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty: The role of polyethylene wear debris and the concept of the effective joint space
    • Schmalzried TP, Jasty M, Harris WH: Periprosthetic bone loss in total hip arthroplasty: The role of polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg 74A:849-863, 1992.
    • (1992) J Bone Joint Surg , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 31
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
    • Schmalzried TP, Kwong LM, Jasty M, et al: The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy. Clin Orthop 274:60-78, 1992.
    • (1992) Clin Orthop , vol.274 , pp. 60-78
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 32
    • 0027521055 scopus 로고
    • Autopsy studies of the cement-bone interface of well-fixed cemented total hip replacements
    • Schmalzried TP, Maloney WJ, Kwong LM, Jasty M, Harris WH: Autopsy studies of the cement-bone interface of well-fixed cemented total hip replacements. J Arthroplasty 8:179-188, 1993.
    • (1993) J Arthroplasty , vol.8 , pp. 179-188
    • Schmalzried, T.P.1    Maloney, W.J.2    Kwong, L.M.3    Jasty, M.4    Harris, W.H.5
  • 33
    • 0032818038 scopus 로고    scopus 로고
    • Reduced bone stress as predicted by composite beam theory correlates with cortical bone loss following cemented total hip arthroplasty
    • Silva MJ, Reed KL, Robertson DD, et al: Reduced bone stress as predicted by composite beam theory correlates with cortical bone loss following cemented total hip arthroplasty. J Orthop Res 17:525-531, 1999.
    • (1999) J Orthop Res , vol.17 , pp. 525-531
    • Silva, M.J.1    Reed, K.L.2    Robertson, D.D.3
  • 34
    • 0020055897 scopus 로고
    • Stress distributions in the acetabular region: I: Before and after total joint replacement
    • Vasu R, Carter DR, Harris WH: Stress distributions in the acetabular region: I: Before and after total joint replacement. J Biomech 15:155-164, 1982.
    • (1982) J Biomech , vol.15 , pp. 155-164
    • Vasu, R.1    Carter, D.R.2    Harris, W.H.3
  • 35
    • 0023161998 scopus 로고
    • Strain and micromotions of press-fit femoral stem prosthesis
    • Walker PS, Schneeweis D, Murphy S, Nelson P: Strain and micromotions of press-fit femoral stem prosthesis. J Biomech 20:693-702, 1987.
    • (1987) J Biomech , vol.20 , pp. 693-702
    • Walker, P.S.1    Schneeweis, D.2    Murphy, S.3    Nelson, P.4
  • 36
    • 0017462028 scopus 로고
    • Reactions of the articular capsule to wear products of artificial joint prostheses
    • Willert HG, Semlitsch J: Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 11:157-164, 1977.
    • (1977) J Biomed Mater Res , vol.11 , pp. 157-164
    • Willert, H.G.1    Semlitsch, J.2
  • 37
    • 0018706337 scopus 로고
    • The mechanism of failure of the femoral prosthesis in total hip replacement
    • Wroblewski BM: The mechanism of failure of the femoral prosthesis in total hip replacement. Int Orthop 3:137-139, 1979.
    • (1979) Int Orthop , vol.3 , pp. 137-139
    • Wroblewski, B.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.