메뉴 건너뛰기




Volumn 1, Issue , 2008, Pages 531-535

Multifield analysis using multiple code coupling of a MEMS based micropump with biocompatible membrane materials for biomedical applications

Author keywords

[No Author keywords available]

Indexed keywords

ABS RESINS; BIOLOGICAL MATERIALS; BIOMEDICAL ENGINEERING; BIOPHYSICS; CODES (SYMBOLS); COMPOSITE MICROMECHANICS; DIFFUSERS (FLUID); DRUG DELIVERY; FUNCTIONAL POLYMERS; MEMS; MICROELECTROMECHANICAL DEVICES; THREE DIMENSIONAL;

EID: 51549092304     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BMEI.2008.320     Document Type: Conference Paper
Times cited : (8)

References (12)
  • 1
    • 0032598155 scopus 로고    scopus 로고
    • Optimization design of a piezoelectric micropump
    • Int. Journal of Adv. Manuf. Technol, 15 (1999) pp
    • Y.H. Mu, N.P. Hung, K.A. Ngoi, "Optimization design of a piezoelectric micropump". Int. Journal of Adv. Manuf. Technol, 15 (1999) pp. 573-576.
    • Mu, Y.H.1    Hung, N.P.2    Ngoi, K.A.3
  • 2
    • 0035980452 scopus 로고    scopus 로고
    • Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology
    • L. Cao, Susan Mantell, Dennis Polla, "Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology". Sensors and Actuators-A, 94 (2001) pp. 117-125.
    • (2001) Sensors and Actuators-A , vol.94 , pp. 117-125
    • Cao, L.1    Mantell, S.2    Polla, D.3
  • 3
    • 33845713196 scopus 로고    scopus 로고
    • Enzhu, Enzhu Li, Longtu Li.,"Simulations and analysis of a piezoelectric micropump
    • B. Wang, Xiangcheng Chu, Enzhu, Enzhu Li, Longtu Li.,"Simulations and analysis of a piezoelectric micropump", Ultrasonics, 44 (2006) pp. 643-646.
    • (2006) Ultrasonics , vol.44 , pp. 643-646
    • Wang, B.1    Chu, X.2
  • 4
    • 0034251181 scopus 로고    scopus 로고
    • Numerical and experimental studies of flat walled diffuser elements for valveless micropumps
    • A. Olsson, E. Stemme, "Numerical and experimental studies of flat walled diffuser elements for valveless micropumps", Sensors and Actuators A- Physical, 84, (2000) pp. 165-175.
    • (2000) Sensors and Actuators A- Physical , vol.84 , pp. 165-175
    • Olsson, A.1    Stemme, E.2
  • 5
    • 0035975581 scopus 로고    scopus 로고
    • Analytical solutions for the dynamic analysis of a valveless micropump: A membrane-fluid coupling study
    • L. Pan, T. Nguyen, G.R Liu, K.Y Lam, T. Jiang, "Analytical solutions for the dynamic analysis of a valveless micropump: a membrane-fluid coupling study", Sensors and Actuators A- Physical, 93 (2001) 173-181.
    • (2001) Sensors and Actuators A- Physical , vol.93 , pp. 173-181
    • Pan, L.1    Nguyen, T.2    Liu, G.R.3    Lam, K.Y.4    Jiang, T.5
  • 6
    • 17444378993 scopus 로고    scopus 로고
    • B. Fan, G. Song, F. Hussain, Simulation of piezoelectrically actuated valveless micropump, J. Smart Materials and Struct, 14 (2005) pp. 400-405.
    • B. Fan, G. Song, F. Hussain, "Simulation of piezoelectrically actuated valveless micropump", J. Smart Materials and Struct, 14 (2005) pp. 400-405.
  • 7
    • 34347376804 scopus 로고    scopus 로고
    • Qifeng Cui, Chengliang Liu, Xuan F. (William) Zha, Study on a piezoelectric micropump for the controlled drug delivery system, Microfluidics and Nanofluidics 3(4) (2007) pp. 377-390.
    • Qifeng Cui, Chengliang Liu, Xuan F. (William) Zha, "Study on a piezoelectric micropump for the controlled drug delivery system", Microfluidics and Nanofluidics 3(4) (2007) pp. 377-390.
  • 8
    • 51549098751 scopus 로고    scopus 로고
    • Coupled Field Analysis Guide, ANSYS Release 11.0, Chapeter4, Multifield Analysis Using Code Coupling, pp. 149
    • Coupled Field Analysis Guide, ANSYS Release 11.0, Chapeter4, Multifield Analysis Using Code Coupling, pp. 149
  • 9
    • 33847681431 scopus 로고    scopus 로고
    • Molecular dynamics simulations of the elastic properties of polymer/carbon nanotube composites
    • Yu Han, James Elliott, "Molecular dynamics simulations of the elastic properties of polymer/carbon nanotube composites", Computational Materials Science, 39, (2006) pp. 315-323
    • (2006) Computational Materials Science , vol.39 , pp. 315-323
    • Han, Y.1    Elliott, J.2
  • 10
    • 34047167637 scopus 로고    scopus 로고
    • Nanomechanical characterization of polymer beam structures for BioMEMS applications
    • Manuel Palacio, Bharat Bhushan, Nicholas Ferrell, Derek Hansford, "Nanomechanical characterization of polymer beam structures for BioMEMS applications", Sensors and Actuators A, 135, (2007) pp. 637-650.
    • (2007) Sensors and Actuators A , vol.135 , pp. 637-650
    • Palacio, M.1    Bhushan, B.2    Ferrell, N.3    Hansford, D.4
  • 11
    • 25844436255 scopus 로고    scopus 로고
    • Disposable polydimethylsiloxane/silicon hybrid chips for protein detection
    • S. Li et al., "Disposable polydimethylsiloxane/silicon hybrid chips for protein detection" Biosensors and Bioelectronics, 21, (2005) pp. 574-580
    • (2005) Biosensors and Bioelectronics , vol.21 , pp. 574-580
    • Li, S.1
  • 12
    • 43449116405 scopus 로고    scopus 로고
    • Qifeng Cui, Chengliang Liu and Xuan F. Zha, Simulation and optimization of a piezoelectric micropump for medical applications, Int. J. Adv. Manuf. Technol, 10.1007/s00170-006-0867-x, Springer, 2006.
    • Qifeng Cui, Chengliang Liu and Xuan F. Zha, "Simulation and optimization of a piezoelectric micropump for medical applications", Int. J. Adv. Manuf. Technol, 10.1007/s00170-006-0867-x, Springer, 2006.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.