메뉴 건너뛰기




Volumn 21, Issue 7, 2008, Pages 663-676

Enhanced sensitivity with fast three-dimensional blood-oxygen-level-dependent functional MRI: Comparison of SENSE-PRESTO and 2D-EPI at 3T

Author keywords

Blood oxygen level dependent (BOLD); Echo planar imaging (EPI); Functional MRI; MR pulse sequence; Principle of echo shifting with a train of observations (PRESTO); Sensitivity encoding (SENSE)

Indexed keywords

ACOUSTIC INTENSITY; BLOOD; CHEMICAL ACTIVATION; NONMETALS; OXYGEN; SIGNAL TO NOISE RATIO; STANDARDS; THREE DIMENSIONAL; TWO DIMENSIONAL;

EID: 50049108951     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1235     Document Type: Article
Times cited : (96)

References (31)
  • 1
    • 0030468874 scopus 로고    scopus 로고
    • Functional magnetic resonance neuroimaging data acquisition techniques
    • Duyn JH, Yang Y, Frank JA, Mattay VS, Hou L. Functional magnetic resonance neuroimaging data acquisition techniques. Neuroimage 1996; 4(3 Pt 3): S76-S83.
    • (1996) Neuroimage , vol.4 , Issue.3 PART 3
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Mattay, V.S.4    Hou, L.5
  • 2
    • 0035849892 scopus 로고    scopus 로고
    • Neurophysiological investigation of the basis of the fMRI signal
    • Logothetis NK, Pauls J, Augath M, Trinath T, Oeltermann A. Neurophysiological investigation of the basis of the fMRI signal. Nature 2001; 412(6843): 150-157.
    • (2001) Nature , vol.412 , Issue.6843 , pp. 150-157
    • Logothetis, N.K.1    Pauls, J.2    Augath, M.3    Trinath, T.4    Oeltermann, A.5
  • 4
    • 0028788237 scopus 로고
    • Echo-volumar imaging (EVI) of the brain at 3.0T: First normal volunteer and functional imaging results
    • Mansfield P, Coxon R, Hykin J. Echo-volumar imaging (EVI) of the brain at 3.0T: first normal volunteer and functional imaging results. J Comput Assist Tomogr 1995; 19(6): 847-852.
    • (1995) J Comput Assist Tomogr , vol.19 , Issue.6 , pp. 847-852
    • Mansfield, P.1    Coxon, R.2    Hykin, J.3
  • 5
    • 0030066541 scopus 로고    scopus 로고
    • Echo-volumar imaging (EVI) at 0.5 T: First whole-body volunteer studies
    • Harvey PR, Mansfield P. Echo-volumar imaging (EVI) at 0.5 T: first whole-body volunteer studies. Magn Reson Med 1996; 35(1): 80-88.
    • (1996) Magn Reson Med , vol.35 , Issue.1 , pp. 80-88
    • Harvey, P.R.1    Mansfield, P.2
  • 6
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model
    • Ogawa S, Menon RS, Tank DW, Kim SG, Merkle H, Ellermann JM, Ugurbil K. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. Biophys. J. 1993; 64(3): 803-812.
    • (1993) Biophys. J , vol.64 , Issue.3 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3    Kim, S.G.4    Merkle, H.5    Ellermann, J.M.6    Ugurbil, K.7
  • 7
    • 0347595449 scopus 로고    scopus 로고
    • EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0T: Sensitivity dependence on echo time and acquisition bandwidth
    • Fera F, Yongbi MN, van Gelderen P, Frank JA, Mattay VS, Duyn JH. EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0T: sensitivity dependence on echo time and acquisition bandwidth. J Magn Reson Imaging 2004; 19(1): 19-26.
    • (2004) J Magn Reson Imaging , vol.19 , Issue.1 , pp. 19-26
    • Fera, F.1    Yongbi, M.N.2    van Gelderen, P.3    Frank, J.A.4    Mattay, V.S.5    Duyn, J.H.6
  • 8
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • Liu G, Sobering G, Duyn J, Moonen CT. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993; 30(6): 764-768.
    • (1993) Magn Reson Med , vol.30 , Issue.6 , pp. 764-768
    • Liu, G.1    Sobering, G.2    Duyn, J.3    Moonen, C.T.4
  • 9
    • 0032189299 scopus 로고    scopus 로고
    • Phase navigator correction in 3D fMRI improves detection of brain activation: Quantitative assessment with a graded motor activation procedure
    • Ramsey NF, van den Brink JS, van Muiswinkel AM, Folkers PJ, Moonen CT, Jansma JM, Kahn RS. Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure. Neuroimage 1998; 8(3): 240-248.
    • (1998) Neuroimage , vol.8 , Issue.3 , pp. 240-248
    • Ramsey, N.F.1    van den Brink, J.S.2    van Muiswinkel, A.M.3    Folkers, P.J.4    Moonen, C.T.5    Jansma, J.M.6    Kahn, R.S.7
  • 12
    • 0011837940 scopus 로고    scopus 로고
    • Moonen CTW, Bandettini PA eds, Springer Verlag: Berlin
    • Ramsey NF. In Functional MRI, Moonen CTW, Bandettini PA (eds). Springer Verlag: Berlin, 1999; 421-432.
    • (1999) Functional MRI , pp. 421-432
    • Ramsey, N.F.1
  • 15
    • 0036892919 scopus 로고    scopus 로고
    • Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging
    • de Zwart JA, van Gelderen P, Kellman P, Duyn JH. Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging. Magn Reson Med 2002; 48(6): 1011-1020.
    • (2002) Magn Reson Med , vol.48 , Issue.6 , pp. 1011-1020
    • de Zwart, J.A.1    van Gelderen, P.2    Kellman, P.3    Duyn, J.H.4
  • 17
    • 0141506077 scopus 로고    scopus 로고
    • A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series
    • Klarhofer M, Dilharreguy B, van Gelderen P, Moonen CT. A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series. Magn Reson Med 2003; 50(4): 830-838.
    • (2003) Magn Reson Med , vol.50 , Issue.4 , pp. 830-838
    • Klarhofer, M.1    Dilharreguy, B.2    van Gelderen, P.3    Moonen, C.T.4
  • 20
    • 1842556754 scopus 로고    scopus 로고
    • A stereotactic method for image-guided transcranial magnetic stimulation validated with fMRI and motor-evoked potentials
    • Neggers SF, Langerak TR, Schutter DJ, Mandl RC, Ramsey NF, Lemmens PJ, Postma A. A stereotactic method for image-guided transcranial magnetic stimulation validated with fMRI and motor-evoked potentials. Neuroimage 2004; 21(4): 1805-1817.
    • (2004) Neuroimage , vol.21 , Issue.4 , pp. 1805-1817
    • Neggers, S.F.1    Langerak, T.R.2    Schutter, D.J.3    Mandl, R.C.4    Ramsey, N.F.5    Lemmens, P.J.6    Postma, A.7
  • 22
    • 0004172276 scopus 로고    scopus 로고
    • 2nd edn, Frackowiak RSJ, Ashburner JT, Penny WD, Zeki S, Friston KJ, Frith CD, Dolan RJ, Price CJ eds, Academic Press: New York
    • Henson RNA. In Human Brain Function, 2nd edn, Frackowiak RSJ, Ashburner JT, Penny WD, Zeki S, Friston KJ, Frith CD, Dolan RJ, Price CJ (eds). Academic Press: New York, 2003.
    • (2003) Human Brain Function
    • Henson, R.N.A.1
  • 23
    • 0026781154 scopus 로고
    • A three dimensional statistical analysis for CBF activation studies in the human brain
    • Worsley KJ, Evans AC, Marrett S, Neelin P. A three dimensional statistical analysis for CBF activation studies in the human brain. J Cereb Blood Flow Metab. 1992; 12: 900-918.
    • (1992) J Cereb Blood Flow Metab , vol.12 , pp. 900-918
    • Worsley, K.J.1    Evans, A.C.2    Marrett, S.3    Neelin, P.4
  • 24
    • 0029931242 scopus 로고    scopus 로고
    • A unified statistical approach for determining significant voxels in images of cerebral activation
    • Worsley KJ, Marrett S, Neelin P, Vandal AC, Friston KJ, Evans AC. A unified statistical approach for determining significant voxels in images of cerebral activation. Hum Brain Mapp 1996; 4: 58-73.
    • (1996) Hum Brain Mapp , vol.4 , pp. 58-73
    • Worsley, K.J.1    Marrett, S.2    Neelin, P.3    Vandal, A.C.4    Friston, K.J.5    Evans, A.C.6
  • 26
    • 0027312891 scopus 로고
    • Tesla gradient recalled echo characteristics of photic stimulation-induced signal changes in the human primary visual cortex
    • Menon RS, Ogawa S, Tank DW, Ugurbil K. Tesla gradient recalled echo characteristics of photic stimulation-induced signal changes in the human primary visual cortex. Magn Reson Med 1993; 30(3): 380-386.
    • (1993) Magn Reson Med , vol.30 , Issue.3 , pp. 380-386
    • Menon, R.S.1    Ogawa, S.2    Tank, D.W.3    Ugurbil, K.4
  • 29
    • 0346373773 scopus 로고    scopus 로고
    • Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    • de Zwart JA, Ledden PJ, van Gelderen P, Bodurka J, Chu R, Duyn JH. Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla. Magn Reson Med 2004; 51(1): 22-26.
    • (2004) Magn Reson Med , vol.51 , Issue.1 , pp. 22-26
    • de Zwart, J.A.1    Ledden, P.J.2    van Gelderen, P.3    Bodurka, J.4    Chu, R.5    Duyn, J.H.6
  • 31
    • 0032477863 scopus 로고    scopus 로고
    • Event-related functional MRI: Past, present, and future
    • Rosen BR, Buckner RL, Dale AM. Event-related functional MRI: past, present, and future. Proc Natl Acad Sci USA 1998; 95(3): 773-780.
    • (1998) Proc Natl Acad Sci USA , vol.95 , Issue.3 , pp. 773-780
    • Rosen, B.R.1    Buckner, R.L.2    Dale, A.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.