메뉴 건너뛰기




Volumn 43, Issue 6, 2000, Pages 779-786

PRESTO-SENSE: An ultrafast whole-brain fMRI technique

Author keywords

PRESTO; SENSE; Sensitivity encoding; Ultrafast imaging; Whole brain functional mapping

Indexed keywords

ENCODING (SYMBOLS); MAGNETIC RESONANCE IMAGING; SIGNAL ENCODING;

EID: 0034089499     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/1522-2594(200006)43:6<779::AID-MRM1>3.0.CO;2-4     Document Type: Article
Times cited : (102)

References (29)
  • 2
    • 0026754226 scopus 로고
    • Intrinsic signal changes accompanying sensory stimulation: Functional brain mapping with magnetic resonance imaging
    • Ogawa S, Tank DW, Menon R, Ellermann JM, Kim SG, Merkle H, Ugurbil K. Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. Proc Natl Acad Sci USA 1992;89:5951-5955.
    • (1992) Proc Natl Acad Sci USA , vol.89 , pp. 5951-5955
    • Ogawa, S.1    Tank, D.W.2    Menon, R.3    Ellermann, J.M.4    Kim, S.G.5    Merkle, H.6    Ugurbil, K.7
  • 5
    • 0032477863 scopus 로고    scopus 로고
    • Event-related functional MRI: Past, present, and future
    • Rosen BR, Buckner RL, Dale AM. Event-related functional MRI: past, present, and future. Proc Natl Acad Sci USA 1998;95:773-780.
    • (1998) Proc Natl Acad Sci USA , vol.95 , pp. 773-780
    • Rosen, B.R.1    Buckner, R.L.2    Dale, A.M.3
  • 6
    • 0343818073 scopus 로고    scopus 로고
    • Variability of the hemodynamic response to different stimuli in single event paradigms
    • Sydney
    • Janz C, Schmitt C, Fischer H, Speck O, Hennig J. Variability of the hemodynamic response to different stimuli in single event paradigms. In: Proc 6th Conf ISMRM, Sydney, 1998. p 165.
    • (1998) Proc 6th Conf ISMRM , pp. 165
    • Janz, C.1    Schmitt, C.2    Fischer, H.3    Speck, O.4    Hennig, J.5
  • 7
    • 0031705384 scopus 로고    scopus 로고
    • Event-related fMRI and the hemodynamic response
    • Buckner RL. Event-related fMRI and the hemodynamic response. Hum Brain Map 1998;6:373-377.
    • (1998) Hum Brain Map , vol.6 , pp. 373-377
    • Buckner, R.L.1
  • 8
    • 0030727106 scopus 로고    scopus 로고
    • Parametric analysis of fMRI data using linear systems methods
    • Cohen MS. Parametric analysis of fMRI data using linear systems methods. Neuroimage 1997;6:93-103.
    • (1997) Neuroimage , vol.6 , pp. 93-103
    • Cohen, M.S.1
  • 9
    • 0029856050 scopus 로고    scopus 로고
    • Detection of cortical activation during averaged single trials of a cognitive task using functional magnetic resonance imaging
    • KM OC
    • Buckner RL, Bandettini PA, KM OC, Savoy RL, Petersen SE, Raichle ME, Rosen BR. Detection of cortical activation during averaged single trials of a cognitive task using functional magnetic resonance imaging. Proc Natl Acad Sci USA 1996;93:14878-14883.
    • (1996) Proc Natl Acad Sci USA , vol.93 , pp. 14878-14883
    • Buckner, R.L.1    Bandettini, P.A.2    Savoy, R.L.3    Petersen, S.E.4    Raichle, M.E.5    Rosen, B.R.6
  • 10
    • 8544281645 scopus 로고    scopus 로고
    • Evaluation of this early response in fMRI in individual subjects using short stimulus duration
    • Hu X, Le TH, Ugurbil K. Evaluation of this early response in fMRI in individual subjects using short stimulus duration. Magn Reson Med 1997;37:877-884.
    • (1997) Magn Reson Med , vol.37 , pp. 877-884
    • Hu, X.1    Le, T.H.2    Ugurbil, K.3
  • 11
    • 0343382407 scopus 로고    scopus 로고
    • Ultrafast wholo-brain 3D fMRI using PRESTO with the acquisition shifted over 2 excitation pulses
    • Sydney
    • van den Brink JS, Hoogduin H, Ramsey NF, Folkers PJM. Ultrafast wholo-brain 3D fMRI using PRESTO with the acquisition shifted over 2 excitation pulses. In: Proc. 6th Conf ISMRM. Sydney, 1998. p 1432.
    • (1998) Proc. 6th Conf ISMRM , pp. 1432
    • Van Den Brink, J.S.1    Hoogduin, H.2    Ramsey, N.F.3    Folkers, P.J.M.4
  • 12
    • 0031964292 scopus 로고    scopus 로고
    • A comparison of fast MR scan techniques for cerebral activation studies at 1.5 Tesla
    • erratum Magn Reson Med 1998 39:following 505
    • Yang Y, Glover GH, van Gelderen P, Patel AC, Mattay VS, Frank JA, Duyn JH. A comparison of fast MR scan techniques for cerebral activation studies at 1.5 Tesla. Magn Reson Med 1998;39:61-67 [erratum Magn Reson Med 1998 39:following 505].
    • (1998) Magn Reson Med , vol.39 , pp. 61-67
    • Yang, Y.1    Glover, G.H.2    Van Gelderen, P.3    Patel, A.C.4    Mattay, V.S.5    Frank, J.A.6    Duyn, J.H.7
  • 14
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • Liu G, Sobering G, Duyn J, Moonen CT. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993;30:764-768.
    • (1993) Magn Reson Med , vol.30 , pp. 764-768
    • Liu, G.1    Sobering, G.2    Duyn, J.3    Moonen, C.T.4
  • 17
    • 0032189299 scopus 로고    scopus 로고
    • Phase navigator correction in 3D fMRI improves detection of brain activation: Quantitative assessment with a graded motor activation procedure
    • Ramsey NF, van den Brink JS, van Muiswinkel AM, Folkers PJ, Moonen CT, Jansma JM, Kahn RS. Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure. Neuroimage 1998;8:240-248.
    • (1998) Neuroimage , vol.8 , pp. 240-248
    • Ramsey, N.F.1    Van Den Brink, J.S.2    Van Muiswinkel, A.M.3    Folkers, P.J.4    Moonen, C.T.5    Jansma, J.M.6    Kahn, R.S.7
  • 21
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods RP, Cherry SR, Mazziotta JC. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 1992;16: 620-633.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 22
    • 0027288454 scopus 로고
    • Processing strategies for time-course data sets in functional MRI of the human brain
    • Bandettini PA, Jesmanowicz A, Wong EC, Hyde JS. Processing strategies for time-course data sets in functional MRI of the human brain. Magn Reson Med 1993;30:161-173.
    • (1993) Magn Reson Med , vol.30 , pp. 161-173
    • Bandettini, P.A.1    Jesmanowicz, A.2    Wong, E.C.3    Hyde, J.S.4
  • 26
    • 0029142688 scopus 로고
    • Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils
    • Wang J, Reykowski A, Dickas J. Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils. IEEE Trans Biomed Eng 1995;42:908-917.
    • (1995) IEEE Trans Biomed Eng , vol.42 , pp. 908-917
    • Wang, J.1    Reykowski, A.2    Dickas, J.3
  • 27
    • 0029147415 scopus 로고
    • Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain
    • Wald LL, Carvajal L, Moyher SE, Nelson SJ, Grant PE, Barkovich AJ, Vigneron DB. Phased array detectors and an automated intensity-correction algorithm for high-resolution MR imaging of the human brain. Magn Reson Med 1995;34:433-439.
    • (1995) Magn Reson Med , vol.34 , pp. 433-439
    • Wald, L.L.1    Carvajal, L.2    Moyher, S.E.3    Nelson, S.J.4    Grant, P.E.5    Barkovich, A.J.6    Vigneron, D.B.7
  • 28
    • 0031751859 scopus 로고    scopus 로고
    • Preoperative staging of cervical carcinoma: Phased array coil fast spin-echo versus body coil spin-echo T2-weighted MR imaging
    • Yu KK, Hricak H, Subak LL, Zaloudek CJ, Powell CB. Preoperative staging of cervical carcinoma: phased array coil fast spin-echo versus body coil spin-echo T2-weighted MR imaging. AJR Am J Roentgenol 1998;171:707-711.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 707-711
    • Yu, K.K.1    Hricak, H.2    Subak, L.L.3    Zaloudek, C.J.4    Powell, C.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.