메뉴 건너뛰기




Volumn 60, Issue 3, 2004, Pages 981-993

SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device

Author keywords

EPID; IMRT; In vivo dosimetry; Quality assurance

Indexed keywords

DOSE DELIVERY; INTENSITY-MODULATED RADIOTHERAPY (IMRT); INTERFACTION RADIOLOGY; PATIENT GEOMETRY;

EID: 4744359705     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2004.06.025     Document Type: Article
Times cited : (24)

References (40)
  • 1
    • 0035192124 scopus 로고    scopus 로고
    • Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode
    • T. LoSasso, C.S. Chui, C.C. Ling Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode Med Phys 28 2001 2209 2219
    • (2001) Med Phys , vol.28 , pp. 2209-2219
    • Losasso, T.1    Chui, C.S.2    Ling, C.C.3
  • 2
    • 0035889335 scopus 로고    scopus 로고
    • Intensity modulated radiotherapy: Current status and issues of interest
    • Intensity Modulated Radiation Therapy Collaborative Working Group (IMRTCWG) 200151
    • Intensity Modulated Radiation Therapy Collaborative Working Group (IMRTCWG) Intensity modulated radiotherapy: Current status and issues of interest Int J Radiat Oncol Biol Phys 200151 880 914
    • Int J Radiat Oncol Biol Phys , pp. 880-914
  • 3
    • 0036311362 scopus 로고    scopus 로고
    • Quality assurance of intensity-modulated radiotherapy
    • D.A. Low Quality assurance of intensity-modulated radiotherapy Semin Radiat Oncol 12 2002 219 228
    • (2002) Semin Radiat Oncol , vol.12 , pp. 219-228
    • Low, D.A.1
  • 4
    • 10744231470 scopus 로고    scopus 로고
    • Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee
    • G.A. Ezzell, J.M. Galvin, D Low Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee Med Phys 30 2003 2089 2115
    • (2003) Med Phys , vol.30 , pp. 2089-2115
    • Ezzell, G.A.1    Galvin, J.M.2    Low, D.3
  • 5
    • 0029865277 scopus 로고    scopus 로고
    • Dosimetric verification of intensity-modulated fields
    • X. Wang, S. Spirou, T LoSasso Dosimetric verification of intensity-modulated fields Med Phys 23 1996 317 327
    • (1996) Med Phys , vol.23 , pp. 317-327
    • Wang, X.1    Spirou, S.2    Losasso, T.3
  • 6
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • C. Burman, C.S. Chui, G Kutcher Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate Int J Radiat Oncol Biol Phys 39 1997 863 873
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 863-873
    • Burman, C.1    Chui, C.S.2    Kutcher, G.3
  • 7
    • 0032521249 scopus 로고    scopus 로고
    • Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients
    • Tsai JS, Wazer DE, Ling MN, et al. Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. Int J Radiat Oncol Biol Phys 1998;40:1213-1230.
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 1213-1230
    • Tsai, J.S.1    Wazer, D.E.2    Ling, M.N.3
  • 8
    • 0032520945 scopus 로고    scopus 로고
    • Phantoms for IMRT dose distribution measurement and treatment verification
    • D.A. Low, R.L. Gerber, S Mutic Phantoms for IMRT dose distribution measurement and treatment verification Int J Radiat Oncol Biol Phys 40 1998 1231 1235
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 1231-1235
    • Low, D.A.1    Gerber, R.L.2    Mutic, S.3
  • 9
    • 0036804332 scopus 로고    scopus 로고
    • Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments
    • A. Van Esch, J. Bohsung, P Sorvari Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments Radiother Oncol 65 2002 53 70
    • (2002) Radiother Oncol , vol.65 , pp. 53-70
    • Van Esch, A.1    Bohsung, J.2    Sorvari, P.3
  • 10
    • 0037423914 scopus 로고    scopus 로고
    • A quality assurance phantom for IMRT dose verification
    • C.M. Ma, S.B. Jiang, T Pawlicki A quality assurance phantom for IMRT dose verification Phys Med Biol 48 2003 561 572
    • (2003) Phys Med Biol , vol.48 , pp. 561-572
    • Ma, C.M.1    Jiang, S.B.2    Pawlicki, T.3
  • 11
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique
    • M. Partridge, P.M. Evans, A Mosleh-Shirazi Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique Med Phys 25 1998 1872 1879
    • (1998) Med Phys , vol.25 , pp. 1872-1879
    • Partridge, M.1    Evans, P.M.2    Mosleh-Shirazi, A.3
  • 12
    • 0031854569 scopus 로고    scopus 로고
    • Accurate portal dose measurement with a fluoroscopic electronic portal imaging device for open and wedged beams and dynamic multileaf collimation
    • K.L. Pasma, M. Kroonwijk, J.C.J de Boer Accurate portal dose measurement with a fluoroscopic electronic portal imaging device for open and wedged beams and dynamic multileaf collimation Phys Med Biol 43 1998 2047 2060
    • (1998) Phys Med Biol , vol.43 , pp. 2047-2060
    • Pasma, K.L.1    Kroonwijk, M.2    De Boer, C.J.3
  • 13
    • 0032934417 scopus 로고    scopus 로고
    • Verification of segmented beam delivery using a commercial electronic portal imaging device
    • A.J. Curtin-Savard, E.B. Podgorsak Verification of segmented beam delivery using a commercial electronic portal imaging device Med Phys 26 1999 737 742
    • (1999) Med Phys , vol.26 , pp. 737-742
    • Curtin-Savard, A.J.1    Podgorsak, E.B.2
  • 14
    • 0032717807 scopus 로고    scopus 로고
    • Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device
    • K.L. Pasma, M.L.P. Dirkx, M. Kroonwijk, A.G. Visser, B.J.M. Heijmen Dosimetric verification of intensity modulated beams produced with dynamic multileaf collimation using an electronic portal imaging device Med Phys 26 1999 2373 2378
    • (1999) Med Phys , vol.26 , pp. 2373-2378
    • Pasma, K.L.1    Dirkx, M.L.P.2    Kroonwijk, M.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 15
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • H.V. James, S. Atherton, G.J Budgell Verification of dynamic multileaf collimation using an electronic portal imaging device Phys Med Biol 45 2000 495 509
    • (2000) Phys Med Biol , vol.45 , pp. 495-509
    • James, H.V.1    Atherton, S.2    Budgell, G.J.3
  • 16
    • 0034957234 scopus 로고    scopus 로고
    • Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields
    • A. Van Esch, B. Vanstraelen, J Verstraete Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields Radiother Oncol 60 2001 181 190
    • (2001) Radiother Oncol , vol.60 , pp. 181-190
    • Van Esch, A.1    Vanstraelen, B.2    Verstraete, J.3
  • 17
    • 0037376492 scopus 로고    scopus 로고
    • Evaluation of rapid dose map acquisition of a scanning liquid-filled ionization chamber electronic portal imaging device
    • J. Chang, G.S. Mageras, C.C. Ling Evaluation of rapid dose map acquisition of a scanning liquid-filled ionization chamber electronic portal imaging device Int J Radiat Oncol Biol Phys 55 2003 1432 1445
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , pp. 1432-1445
    • Chang, J.1    Mageras, G.S.2    Ling, C.C.3
  • 18
    • 0345688217 scopus 로고    scopus 로고
    • Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    • S.C. Vieira, R.S.J.P. Kaatee, M.L.P Dirkx Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device Med Phys 30 2003 2981 2987
    • (2003) Med Phys , vol.30 , pp. 2981-2987
    • Vieira, S.C.1    Kaatee, R.S.J.P.2    Dirkx, L.P.3
  • 19
    • 0031803138 scopus 로고    scopus 로고
    • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy: An algorithm for open beams
    • K.L. Pasma, B.J.M. Heijmen, M Kroonwijk Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy An algorithm for open beams Med Phys 25 1998 830 840
    • (1998) Med Phys , vol.25 , pp. 830-840
    • Pasma, K.L.1    Heijmen, B.J.M.2    Kroonwijk, M.3
  • 20
    • 0036735619 scopus 로고    scopus 로고
    • Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device
    • S.C. Vieira, M.L.P. Dirkx, K.L Pasma Fast and accurate leaf verification for dynamic multileaf collimation using an electronic portal imaging device Med Phys 29 2002 2034 2040
    • (2002) Med Phys , vol.29 , pp. 2034-2040
    • Vieira, S.C.1    Dirkx, M.L.P.2    Pasma, K.L.3
  • 21
    • 0032433905 scopus 로고    scopus 로고
    • In vivo dosimetry for prostate cancer patients using an electronic portal imaging device: Demonstration of internal organ motion
    • M. Kroonwijk, K.L. Pasma, S Quint In vivo dosimetry for prostate cancer patients using an electronic portal imaging device: Demonstration of internal organ motion Radiother Oncol 49 1998 125 132
    • (1998) Radiother Oncol , vol.49 , pp. 125-132
    • Kroonwijk, M.1    Pasma, K.L.2    Quint, S.3
  • 22
    • 0032784892 scopus 로고    scopus 로고
    • Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    • K.L. Pasma, M. Kroonwijk, S Quint Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients Int J Radiat Oncol Biol Phys 45 1999 1297 1303
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 1297-1303
    • Pasma, K.L.1    Kroonwijk, M.2    Quint, S.3
  • 23
    • 0033984574 scopus 로고    scopus 로고
    • On-line set-up corrections during radiotherapy of patients with gynecologic tumors
    • J.C. Stroom, M.J. Olofsen-van Acht, S Quint On-line set-up corrections during radiotherapy of patients with gynecologic tumors Int J Radiat Oncol Biol Phys 46 2000 499 506
    • (2000) Int J Radiat Oncol Biol Phys , vol.46 , pp. 499-506
    • Stroom, J.C.1    Olofsen-Van Acht, M.J.2    Quint, S.3
  • 24
    • 0035425538 scopus 로고    scopus 로고
    • A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload
    • H.C. de Boer, B.J.M. Heijmen A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload Int J Radiat Oncol Biol Phys 50 2001 1350 1365
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 1350-1365
    • De Boer, H.C.1    Heijmen, B.J.M.2
  • 25
    • 0035283667 scopus 로고    scopus 로고
    • Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning
    • H.C. de Boer, J.R. van Sornsen de Koste, S Senan Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning Int J Radiat Oncol Biol Phys 49 2001 857 868
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 857-868
    • De Boer, H.C.1    Van Sornsen De Koste, J.R.2    Senan, S.3
  • 26
    • 0035197855 scopus 로고    scopus 로고
    • Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation
    • H.C. de Boer, J.R. van Sornsen de Koste, C.L Creutzberg Electronic portal image assisted reduction of systematic set-up errors in head and neck irradiation Radiother Oncol 61 2001 299 308
    • (2001) Radiother Oncol , vol.61 , pp. 299-308
    • De Boer, H.C.1    Van Sornsen De Koste, J.R.2    Creutzberg, C.L.3
  • 27
    • 0029591732 scopus 로고
    • The accuracy of CT-based inhomogeneity corrections and in vivo dosimetry for the treatment of lung cancer
    • M. Essers, J.H. Lanson, G Leunens The accuracy of CT-based inhomogeneity corrections and in vivo dosimetry for the treatment of lung cancer Radiother Oncol 37 1995 199 208
    • (1995) Radiother Oncol , vol.37 , pp. 199-208
    • Essers, M.1    Lanson, J.H.2    Leunens, G.3
  • 28
    • 0031744989 scopus 로고    scopus 로고
    • First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose
    • R. Boellaard, M. van Herk, H Uiterwaal First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose Radiother Oncol 47 1998 303 312
    • (1998) Radiother Oncol , vol.47 , pp. 303-312
    • Boellaard, R.1    Van Herk, M.2    Uiterwaal, H.3
  • 29
    • 4644365006 scopus 로고    scopus 로고
    • The CCD-camera based electronic portal imaging device (EPID) revisited; Can a-Si flat panel EPIDs do better?
    • 200264
    • J.C.J. de Boer, J.C. Barnhoorn, B.J.M. Heijmen The CCD-camera based electronic portal imaging device (EPID) revisited; can a-Si flat panel EPIDs do better? [Abstract] Radiother Oncol 200264 S12
    • Radiother Oncol
    • De Boer, J.C.J.1    Barnhoorn, J.C.2    Heijmen, B.J.M.3
  • 30
    • 0033976918 scopus 로고    scopus 로고
    • Characterization of a high elbow, fluoroscopic electronic portal imaging device for portal dosimetry
    • J.C.J. de Boer, B.J.M. Heijmen, K.L Pasma Characterization of a high elbow, fluoroscopic electronic portal imaging device for portal dosimetry Phys Med Biol 45 2000 197 216
    • (2000) Phys Med Biol , vol.45 , pp. 197-216
    • De Boer, J.C.J.1    Heijmen, B.J.M.2    Pasma, K.L.3
  • 31
    • 0031860585 scopus 로고    scopus 로고
    • X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays
    • P. Munro, D.C. Bouius X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays Med Phys 25 1998 689 702
    • (1998) Med Phys , vol.25 , pp. 689-702
    • Munro, P.1    Bouius, D.C.2
  • 32
    • 0037458227 scopus 로고    scopus 로고
    • Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device
    • S.C. Vieira, M.L.P. Dirkx, K.L Pasma Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device Phys Med Biol 48 2003 157 166
    • (2003) Phys Med Biol , vol.48 , pp. 157-166
    • Vieira, S.C.1    Dirkx, M.L.P.2    Pasma, K.L.3
  • 33
    • 0032976707 scopus 로고    scopus 로고
    • Internal organ motion in prostate cancer patients treated in prone and supine treatment position
    • J.C. Stroom, P.C.M. Koper, G.A Korevaar Internal organ motion in prostate cancer patients treated in prone and supine treatment position Radiother Oncol 51 1999 237 248
    • (1999) Radiother Oncol , vol.51 , pp. 237-248
    • Stroom, J.C.1    Koper, P.C.M.2    Korevaar, G.A.3
  • 35
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • M.C. Kirby, P.C. Williams The use of an electronic portal imaging device for exit dosimetry and quality control measurements Int J Radiat Oncol Biol Phys 31 1995 593 596
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 593-596
    • Kirby, M.C.1    Williams, P.C.2
  • 36
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • V.N. Hansen, P.M. Evans, W. Swindell The application of transit dosimetry to precision radiotherapy Med Phys 23 1996 713 721
    • (1996) Med Phys , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 37
    • 0033828191 scopus 로고    scopus 로고
    • Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: Original research in the treatment of thoracic neoplasms
    • K. Nakagawa, Y. Aoki, M Tago Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: Original research in the treatment of thoracic neoplasms Int J Radiat Oncol Biol Phys 48 2000 449 457
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 449-457
    • Nakagawa, K.1    Aoki, Y.2    Tago, M.3
  • 38
    • 0035044866 scopus 로고    scopus 로고
    • A feasible method for clinical delivery verification and dose reconstruction in tomotherapy
    • J.M. Kapatoes, G.H. Olivera, K.J Ruchala A feasible method for clinical delivery verification and dose reconstruction in tomotherapy Med Phys 28 2001 528 542
    • (2001) Med Phys , vol.28 , pp. 528-542
    • Kapatoes, J.M.1    Olivera, G.H.2    Ruchala, K.J.3
  • 39
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • D.A. Jaffray, J.H. Siewerdsen, J.W Wong Flat-panel cone-beam computed tomography for image-guided radiation therapy Int J Radiat Oncol Biol Phys 53 2002 1337 1349
    • (2002) Int J Radiat Oncol Biol Phys , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3
  • 40
    • 0036703540 scopus 로고    scopus 로고
    • IMRT verification by three-dimensional dose reconstruction from portal beam measurements
    • M. Partridge, M. Ebert, B.M. Hesse IMRT verification by three-dimensional dose reconstruction from portal beam measurements Med Phys 29 2002 1847 1858
    • (2002) Med Phys , vol.29 , pp. 1847-1858
    • Partridge, M.1    Ebert, M.2    Hesse, B.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.