메뉴 건너뛰기




Volumn 48, Issue 2, 2003, Pages 157-166

Dosimetric verification of x-ray fields with steep dose gradients using an electronic portal imaging device

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CAMERAS; CHARGE COUPLED DEVICES; DOSIMETRY; FLUORESCENCE; IMAGING SYSTEMS; MEDICAL IMAGING; PHOTONS; X RAYS;

EID: 0037458227     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/48/2/302     Document Type: Article
Times cited : (28)

References (10)
  • 1
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • Burman C et al 1997 Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate Int. J. Radiat. Oncol. Biol. Phys. 39 863-73
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.39 , pp. 863-873
    • Burman, C.1
  • 2
    • 0033976918 scopus 로고    scopus 로고
    • Characterization of a high elbow, fluoroscopic electronic portal imaging device for portal dosimetry
    • de Boer J C J, Heijmen B J M, Pasma K L and Visser A G 2000 Characterization of a high elbow, fluoroscopic electronic portal imaging device for portal dosimetry Phys. Med. Biol. 45 197-16
    • (2000) Phys. Med. Biol. , vol.45 , pp. 197-216
    • de Boer, J.C.J.1    Heijmen, B.J.M.2    Pasma, K.L.3    Visser, A.G.4
  • 3
    • 0034957793 scopus 로고    scopus 로고
    • Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation
    • Essers M, de Langen M, Dirkx M L P and Heijmen B J M 2001 Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation Radiother. Oncol. 60 215-24
    • (2001) Radiother. Oncol. , vol.60 , pp. 215-224
    • Essers, M.1    de Langen, M.2    Dirkx, M.L.P.3    Heijmen, B.J.M.4
  • 5
    • 0032433905 scopus 로고    scopus 로고
    • In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID): Detection of internal organ motion
    • Kroonwijk M, Pasma K L, Quint S, Koper P C M, Visser A G and Heijmen B J M 1998 In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID): detection of internal organ motion Radiother. Oncol. 49 125-32
    • (1998) Radiother. Oncol. , vol.49 , pp. 125-132
    • Kroonwijk, M.1    Pasma, K.L.2    Quint, S.3    Koper, P.C.M.4    Visser, A.G.5    Heijmen, B.J.M.6
  • 6
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • Low D A, Harms W B, Mutic S and Purdy J A 1998 A technique for the quantitative evaluation of dose distributions Med. Phys. 25 656-61
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 7
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy?
    • Mijnheer B J, Battermann J J and Wambersie A 1987 What degree of accuracy is required and can be achieved in photon and neutron therapy? Radiother. Oncol. 8 237-52
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Battermann, J.J.2    Wambersie, A.3
  • 8
    • 0032717807 scopus 로고    scopus 로고
    • Dosimetric verification of intensity modulated beams produced with dynamic mulitleaf collimation using an electronic portal imaging device
    • Pasma K L, Dirkx M L P, Kroonwijk M, Visser A G and Heijmen B J M 1999a Dosimetric verification of intensity modulated beams produced with dynamic mulitleaf collimation using an electronic portal imaging device Med. Phys. 26 2373-8
    • (1999) Med. Phys. , vol.26 , pp. 2373-2378
    • Pasma, K.L.1    Dirkx, M.L.P.2    Kroonwijk, M.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 9
    • 0031854569 scopus 로고    scopus 로고
    • Accurate portal dose measurement with a fluoroscopic electronic portal imaging device for open and wedged beams and dynamic multileaf collimation
    • Pasma K L, Kroonwijk M, de Boer J C J, Visser A G and Heijmen B J M 1998 Accurate portal dose measurement with a fluoroscopic electronic portal imaging device for open and wedged beams and dynamic multileaf collimation Phys. Med. Biol. 43 2047-60
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2047-2060
    • Pasma, K.L.1    Kroonwijk, M.2    de Boer, J.C.J.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 10
    • 0032784892 scopus 로고    scopus 로고
    • Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients prostate
    • Pasma K L, Kroonwijk M, Quint S, Visser A G and Heijmen B J M 1999b Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients prostate Int. J. Radiat. Oncol. Biol. Phys. 45 1297-303
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.45 , pp. 1297-1303
    • Pasma, K.L.1    Kroonwijk, M.2    Quint, S.3    Visser, A.G.4    Heijmen, B.J.M.5