Radioactivity detectors for high-performance liquid chromatography in drug metabolism studies

Author keywords

Accelerator mass spectrometry; Heterogeneous counting; Homogeneous counting; HPLC; Microplate solid scintillation counting; Radioactivity detection

Indexed keywords

BIOCHEMISTRY; BODY FLUIDS; CHEMICALS; CHEMOTHERAPY; CHROMATOGRAPHIC ANALYSIS; CHROMATOGRAPHY; DETECTORS; DRUG DELIVERY; DRUG DOSAGE; FLUIDS; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; LIGHT EMISSION; LIQUID CHROMATOGRAPHY; LUMINESCENCE; MASS SPECTROMETRY; METABOLISM; NUCLEAR PHYSICS; RADIATION; RADIOACTIVITY; SCINTILLATION; SCINTILLATION COUNTERS;

EID: 45849124587     PISSN: 10826076     EISSN: 1520572X     Source Type: Journal    
DOI: 10.1080/10826070802126254     Document Type: Review
Times cited : (14)

References (81)
  • 1
    • 30444454824 scopus 로고    scopus 로고
    • Drug metabolism and pharmacogenetics: The British contribution to fields of international significance
    • Caldwell, J. Drug metabolism and pharmacogenetics: The British contribution to fields of international significance. Brit. J. Pharmacol. 2006, 147, S89-S99.
    • (2006) Brit. J. Pharmacol , vol.147
    • Caldwell, J.1
  • 2
    • 0020525989 scopus 로고
    • Richard Tecwyn Williams: The man, his work, his impact
    • Neuberger, A.; Smith, L. Richard Tecwyn Williams: the man, his work, his impact. Drug Metab. Rev. 1983, 14, 559-607.
    • (1983) Drug Metab. Rev , vol.14 , pp. 559-607
    • Neuberger, A.1    Smith, L.2
  • 3
    • 0011218338 scopus 로고
    • The estimation of basic organic compounds in biological material. I. General principles
    • Brodie, B.B.; Udenfriend, S.; Baer, J.E. The estimation of basic organic compounds in biological material. I. General principles. J. Biol. Chem. 1947, 168, 299-309.
    • (1947) J. Biol. Chem , vol.168 , pp. 299-309
    • Brodie, B.B.1    Udenfriend, S.2    Baer, J.E.3
  • 4
    • 45849151774 scopus 로고
    • The estimation of basic organic compounds in biological material. VI. Estimation by ultraviolet spectrophotometry
    • Josepheson, E.S.; Udenfriend, S.; Brodie, B.B. The estimation of basic organic compounds in biological material. VI. Estimation by ultraviolet spectrophotometry. J. Biol. Chem. 1947, 168, 341-344.
    • (1947) J. Biol. Chem , vol.168 , pp. 341-344
    • Josepheson, E.S.1    Udenfriend, S.2    Brodie, B.B.3
  • 6
    • 84908558283 scopus 로고
    • The metabolic degradation in the mouse of dibenzanthracene labeled in the 9 and 10 positions with carbon 14
    • Heidelberger, C.; Perkins, M.S.; Kirk, M.R. The metabolic degradation in the mouse of dibenzanthracene labeled in the 9 and 10 positions with carbon 14. Cancer Res. 1948, 8, 261-275.
    • (1948) Cancer Res , vol.8 , pp. 261-275
    • Heidelberger, C.1    Perkins, M.S.2    Kirk, M.R.3
  • 7
    • 8244245521 scopus 로고
    • The distribution of radioactivity following the feeding of carbon 14-labeled 2-acetylaminofluorene to rats
    • Morris, H.P.; Weisburger, J.H.; Weisburger, E.K. The distribution of radioactivity following the feeding of carbon 14-labeled 2-acetylaminofluorene to rats. Cancer Res. 1950, 10, 620-624.
    • (1950) Cancer Res , vol.10 , pp. 620-624
    • Morris, H.P.1    Weisburger, J.H.2    Weisburger, E.K.3
  • 9
    • 33947448199 scopus 로고
    • Chemical analysis and isotopic assay of organic compounds
    • Anderson, R.C.; Delabarre, Y.; Bothner-By, A.A. Chemical analysis and isotopic assay of organic compounds. Anal. Chem. 1952, 24, 1298-1303.
    • (1952) Anal. Chem , vol.24 , pp. 1298-1303
    • Anderson, R.C.1    Delabarre, Y.2    Bothner-By, A.A.3
  • 10
    • 33947454301 scopus 로고
    • Microdetermination of carbon and hydrogen in organic compounds
    • Naughton, J.J.; Frodyma, M.M. Microdetermination of carbon and hydrogen in organic compounds. Anal. Chem. 1950, 22, 711-714.
    • (1950) Anal. Chem , vol.22 , pp. 711-714
    • Naughton, J.J.1    Frodyma, M.M.2
  • 12
    • 45849122555 scopus 로고
    • The fate of 2,4,6-tri-(30,50-di-tert.-butyl-4′-hydroxybenzyl)mesitylene (Ionox 330) in the dog and rat
    • Wright, A.S.; Crowne, R.S.; Hathway, D.E. The fate of 2,4,6-tri-(30,50-di-tert.-butyl-4′-hydroxybenzyl)mesitylene (Ionox 330) in the dog and rat. Biochem. J. 1965, 95, 98-103.
    • (1965) Biochem. J , vol.95 , pp. 98-103
    • Wright, A.S.1    Crowne, R.S.2    Hathway, D.E.3
  • 13
    • 0014002315 scopus 로고
    • Recent investigations on cholesterol metabolism: Critical evaluation of radiochromatography and estimation procedures
    • Pascaud, P. Recent investigations on cholesterol metabolism: Critical evaluation of radiochromatography and estimation procedures. Adv. Tracer Methodol. 1966, 3, 181-198.
    • (1966) Adv. Tracer Methodol , vol.3 , pp. 181-198
    • Pascaud, P.1
  • 14
    • 0014784183 scopus 로고    scopus 로고
    • Hazelton, H.R.; Johnson, P. British J. Pharmacol. The use of gas-liquid chromatography-mass spectrometry in biochemical pharmacology. Biochem. Pharmacol. 1970, 39, 236P-237P.
    • Hazelton, H.R.; Johnson, P. British J. Pharmacol. The use of gas-liquid chromatography-mass spectrometry in biochemical pharmacology. Biochem. Pharmacol. 1970, 39, 236P-237P.
  • 15
    • 0009283254 scopus 로고
    • Radiochromatography: The Chromatography and Electrophoresis of Radiolabelled Compounds
    • Elsevier: Amsterdam
    • Roberts, T.A. Radiochromatography: The Chromatography and Electrophoresis of Radiolabelled Compounds. Journal of chromatography library series Vol. 14; Elsevier: Amsterdam, 1978.
    • (1978) Journal of chromatography library series , vol.14
    • Roberts, T.A.1
  • 16
    • 0025144610 scopus 로고
    • Radiochromatography in pharmaceutical and biomedical analysis
    • Veltkamp, A.C. Radiochromatography in pharmaceutical and biomedical analysis. J. Chromatogr. 1990, 531, 101-129.
    • (1990) J. Chromatogr , vol.531 , pp. 101-129
    • Veltkamp, A.C.1
  • 17
    • 4544295323 scopus 로고    scopus 로고
    • The use of radiolabeled compounds for ADME studies in discovery and extraploratory development
    • Marathe, P.H.; Shyu, W.C.; Humphreys, W.G. The use of radiolabeled compounds for ADME studies in discovery and extraploratory development. Curr. Pharmaceut. Des. 2004, 10, 2991-3008.
    • (2004) Curr. Pharmaceut. Des , vol.10 , pp. 2991-3008
    • Marathe, P.H.1    Shyu, W.C.2    Humphreys, W.G.3
  • 18
    • 0022860421 scopus 로고    scopus 로고
    • Nieves, E.; Rosenspire, K.C.; Filc-DeRicco, S.; Gelbard, A.S.; Cooper, Arthur J.L. High-performance liquid chromatographic on-line flow-through radioactivity detector system for analyzing amino acids and metabolites labeled with nitrogen-13. J. Chromatogr. 1986, 83, (2), 325-337.
    • Nieves, E.; Rosenspire, K.C.; Filc-DeRicco, S.; Gelbard, A.S.; Cooper, Arthur J.L. High-performance liquid chromatographic on-line flow-through radioactivity detector system for analyzing amino acids and metabolites labeled with nitrogen-13. J. Chromatogr. 1986, 83, (2), 325-337.
  • 19
    • 33845734598 scopus 로고    scopus 로고
    • A regulatory perspective on issues and approaches in characterizing human metabolites
    • Davis-Bruno, K.L.; Atrakchi, A. A regulatory perspective on issues and approaches in characterizing human metabolites. Chem. Res. Toxicol. 2006, 19, 1561-1563.
    • (2006) Chem. Res. Toxicol , vol.19 , pp. 1561-1563
    • Davis-Bruno, K.L.1    Atrakchi, A.2
  • 21
    • 24944563781 scopus 로고    scopus 로고
    • Seeing through the mist: Abundance versus percentage, commentary on metabolites in safety testing
    • Smith, D.A.; Obach, R.S. Seeing through the mist: Abundance versus percentage, commentary on metabolites in safety testing. Drug Metabol. Dispos. 2005, 33, 1409-1417.
    • (2005) Drug Metabol. Dispos , vol.33 , pp. 1409-1417
    • Smith, D.A.1    Obach, R.S.2
  • 22
    • 36849139233 scopus 로고
    • Scintillation counters for radioactive sample measurement
    • Anger, H.O. Scintillation counters for radioactive sample measurement. Rev. Sci. Instrum. 1951, 22, 912-914.
    • (1951) Rev. Sci. Instrum , vol.22 , pp. 912-914
    • Anger, H.O.1
  • 23
    • 36949065778 scopus 로고
    • Radioassay of aqueous solutions mixed with solid crystalline fluors
    • Steinberg, D. Radioassay of aqueous solutions mixed with solid crystalline fluors. Nature (London) 1959, 183, 1253-1254.
    • (1959) Nature (London) , vol.183 , pp. 1253-1254
    • Steinberg, D.1
  • 24
    • 1942510184 scopus 로고
    • Radioassay of carbon-14 in aqueous solutions by using a liquid scintillation spectrometer
    • Steinberg, D. Radioassay of carbon-14 in aqueous solutions by using a liquid scintillation spectrometer. Nature (London) 1958, 182, 740-741.
    • (1958) Nature (London) , vol.182 , pp. 740-741
    • Steinberg, D.1
  • 26
    • 4143116643 scopus 로고    scopus 로고
    • Liquid chromatography-accurate radioisotope counting and microplate scintillation counter technologies in drug metabolism studies
    • Nassar, A.E.F.; Parmentier, Y.; Martinet, M.; Lee, D.Y. Liquid chromatography-accurate radioisotope counting and microplate scintillation counter technologies in drug metabolism studies. J. Chromatogr. Sci. 2004, 42, 348-353.
    • (2004) J. Chromatogr. Sci , vol.42 , pp. 348-353
    • Nassar, A.E.F.1    Parmentier, Y.2    Martinet, M.3    Lee, D.Y.4
  • 27
    • 23544462582 scopus 로고
    • Limits for qualitative detection and quantitative determination: Application to radiochemistry
    • Lurie, L.A. Limits for qualitative detection and quantitative determination: Application to radiochemistry. Anal. Chem. 1968, 40, 586.
    • (1968) Anal. Chem , vol.40 , pp. 586
    • Lurie, L.A.1
  • 28
    • 33751109698 scopus 로고
    • Unterscheidung und Nachweis von Aktivitäten
    • Plesch, R. Unterscheidung und Nachweis von Aktivitäten. Die Atomwirtschaft 1962, 7, 602.
    • (1962) Die Atomwirtschaft , vol.7 , pp. 602
    • Plesch, R.1
  • 29
    • 33750102850 scopus 로고    scopus 로고
    • Bruin, G.J.; Waldmeier, F; Boernsen, K.O.; Pfaar, U.; Gross, G.; Zollinger, M. A microplate solid scintillation counter as a radioactive detector for high performance liquid chromatrography in drug metabolism: Validation and applications. J. Chromatogr. A 2006, 1133, 184-194.
    • Bruin, G.J.; Waldmeier, F; Boernsen, K.O.; Pfaar, U.; Gross, G.; Zollinger, M. A microplate solid scintillation counter as a radioactive detector for high performance liquid chromatrography in drug metabolism: Validation and applications. J. Chromatogr. A 2006, 1133, 184-194.
  • 30
    • 45849137526 scopus 로고
    • Application of filter paper partition chromatography to radioactive tracer studies
    • Fink, R.M.; Dent, C.E.; Fink, K. Application of filter paper partition chromatography to radioactive tracer studies. Nature (London) 1947, 160, 801-803.
    • (1947) Nature (London) , vol.160 , pp. 801-803
    • Fink, R.M.1    Dent, C.E.2    Fink, K.3
  • 31
    • 33947087114 scopus 로고
    • Summary of the state of the art in radiochromatography
    • Prydz, S. Summary of the state of the art in radiochromatography. Anal. Chem. 1973, 45, (14), 2317-2326.
    • (1973) Anal. Chem , vol.45 , Issue.14 , pp. 2317-2326
    • Prydz, S.1
  • 32
    • 33947490833 scopus 로고
    • A Compact radiochemical gas chromatograph
    • James, A.T.; Piper, E.A. A Compact radiochemical gas chromatograph. Anal. Chem. 1963, 35, 515-520.
    • (1963) Anal. Chem , vol.35 , pp. 515-520
    • James, A.T.1    Piper, E.A.2
  • 33
    • 0028345703 scopus 로고
    • Online coupling of packed column supercritical fluid chromatography with multiple wavelength detector and radioactivity flow-through detector
    • Lembke, P.; Engelhardt, H.; Ecker, R. Online coupling of packed column supercritical fluid chromatography with multiple wavelength detector and radioactivity flow-through detector. Chromatographia 1994, 38, (7-8), 491-501.
    • (1994) Chromatographia , vol.38 , Issue.7-8 , pp. 491-501
    • Lembke, P.1    Engelhardt, H.2    Ecker, R.3
  • 34
    • 0004290503 scopus 로고
    • Metabolism and excretion of carbon-14 labeled diethylcarbamazine
    • Bangham, D.R. Metabolism and excretion of carbon-14 labeled diethylcarbamazine. Brit. J. Pharmacol. Chemother. 1955, 10, 397-405.
    • (1955) Brit. J. Pharmacol. Chemother , vol.10 , pp. 397-405
    • Bangham, D.R.1
  • 35
    • 45849128393 scopus 로고
    • A simple helium - ethanol flow counter for monitoring chromatograph-column effluents containing weak beta-emitting isotopes
    • Bangham, D.R. A simple helium - ethanol flow counter for monitoring chromatograph-column effluents containing weak beta-emitting isotopes. Biochem. J. 1956, 62, (4), 552-553.
    • (1956) Biochem. J , vol.62 , Issue.4 , pp. 552-553
    • Bangham, D.R.1
  • 36
    • 45849132107 scopus 로고
    • Continuous determination of carbon-14 and sulfur-35 in aqueous medium by a scintillation device. Application to chromatographic effluents
    • Schram, E.; Lombaert, R. Continuous determination of carbon-14 and sulfur-35 in aqueous medium by a scintillation device. Application to chromatographic effluents. Anal. Chim. Acta 1957, 17, 417-422.
    • (1957) Anal. Chim. Acta , vol.17 , pp. 417-422
    • Schram, E.1    Lombaert, R.2
  • 37
    • 0003054424 scopus 로고
    • Determination of tritium and carbon-14 in aqueous solution with anthracene powder
    • Schram, E.; Lombaert, R. Determination of tritium and carbon-14 in aqueous solution with anthracene powder. Anal. Biochem. 1962, 3, 68-74.
    • (1962) Anal. Biochem , vol.3 , pp. 68-74
    • Schram, E.1    Lombaert, R.2
  • 38
    • 0345623696 scopus 로고
    • Continuous scintillation counting of carbon-14 and tritium in effluent of the automatic amino acid analyzer
    • Piez, K.A. Continuous scintillation counting of carbon-14 and tritium in effluent of the automatic amino acid analyzer. Anal. Biochem. 1962, 4, 444-458.
    • (1962) Anal. Biochem , vol.4 , pp. 444-458
    • Piez, K.A.1
  • 39
    • 4244071555 scopus 로고
    • A continuous flow analyzer for recording of light absorption and radioactivity in the eluates from chromatographic columns
    • Sjoberg, I.; Agren, G. A continuous flow analyzer for recording of light absorption and radioactivity in the eluates from chromatographic columns. Anal. Chem. 1964, 36, (6), 1017-1021.
    • (1964) Anal. Chem , vol.36 , Issue.6 , pp. 1017-1021
    • Sjoberg, I.1    Agren, G.2
  • 40
    • 0014289167 scopus 로고
    • Continuous-flow monitor system for detection of UV absorbance, carbon-14, and tritium effluent of a column chromatogram
    • Hunt, J.A. Continuous-flow monitor system for detection of UV absorbance, carbon-14, and tritium effluent of a column chromatogram. Anal. Biochem. 1968, 23, (2), 289-300.
    • (1968) Anal. Biochem , vol.23 , Issue.2 , pp. 289-300
    • Hunt, J.A.1
  • 41
    • 45849086211 scopus 로고
    • Scintillation counter for continuous monitoring of radioactivity in solutions
    • Clifford, K.H.; Hewett, A.J.W.; Popjak, G.J. Scintillation counter for continuous monitoring of radioactivity in solutions. J. Chromatogr. 1969, 40, (3-4), 377-385.
    • (1969) J. Chromatogr , vol.40 , Issue.3-4 , pp. 377-385
    • Clifford, K.H.1    Hewett, A.J.W.2    Popjak, G.J.3
  • 42
    • 45849083569 scopus 로고
    • Design and evaluation of a microradiometric detector for column liquid chromatography
    • Van Urk-Schoen, A.M.; Huber, J.F.K. Design and evaluation of a microradiometric detector for column liquid chromatography. Anal. Chim. Acta 1970, 52, (3), 519-527.
    • (1970) Anal. Chim. Acta , vol.52 , Issue.3 , pp. 519-527
    • Van Urk-Schoen, A.M.1    Huber, J.F.K.2
  • 43
    • 2142688933 scopus 로고
    • Continuous detection of radioactive effluents in liquid chromatography by heterogeneous or homogeneous scintillation counting
    • Schutte, L. Continuous detection of radioactive effluents in liquid chromatography by heterogeneous or homogeneous scintillation counting. J. Chromatogr. 1972, 72, (2), 303-309.
    • (1972) J. Chromatogr , vol.72 , Issue.2 , pp. 303-309
    • Schutte, L.1
  • 44
    • 85012812359 scopus 로고
    • Application of solid scintillators in high pressure radio column chromatography
    • Sieswerda, G.B.; Polak, H.L. Application of solid scintillators in high pressure radio column chromatography. Liq. Scintill. Count. 1972, 2, 49-59.
    • (1972) Liq. Scintill. Count , vol.2 , pp. 49-59
    • Sieswerda, G.B.1    Polak, H.L.2
  • 45
    • 45849144825 scopus 로고
    • Flow versus batch detection of radioactivity in column liquid chromatography
    • Sieswerda, G.B.; Poppe, H.; Huber, J.F.K. Flow versus batch detection of radioactivity in column liquid chromatography. Anal. Chim. Acta 1975, 78, (2), 343-358.
    • (1975) Anal. Chim. Acta , vol.78 , Issue.2 , pp. 343-358
    • Sieswerda, G.B.1    Poppe, H.2    Huber, J.F.K.3
  • 46
    • 0017440360 scopus 로고
    • Metabolism and pharmacokinetics of piprozoline in rat, dog and man. 2nd communication: Determination of metabolic profiles with the aid of an HPLC-radioactivity detection system following direct injection of urine and bile onto a reversed-phase column (author's transl.)
    • 2b, 508-511
    • Hodenberg, A.V.; Klemisch, W.; Vollmer, K.O. Metabolism and pharmacokinetics of piprozoline in rat, dog and man. 2nd communication: Determination of metabolic profiles with the aid of an HPLC-radioactivity detection system following direct injection of urine and bile onto a reversed-phase column (author's transl.). Arzneimittel-Forschung 1977, 27, (2b), 508-511.
    • (1977) Arzneimittel-Forschung , vol.27
    • Hodenberg, A.V.1    Klemisch, W.2    Vollmer, K.O.3
  • 47
    • 0016431486 scopus 로고
    • Novel method of sample transport and its application for continuous detection of radioactivity in the effluent of the high speed amino acid analyzer
    • Bakay, B. Novel method of sample transport and its application for continuous detection of radioactivity in the effluent of the high speed amino acid analyzer. Anal. Biochem. 1975, 63, (1), 87-98.
    • (1975) Anal. Biochem , vol.63 , Issue.1 , pp. 87-98
    • Bakay, B.1
  • 48
    • 0348249575 scopus 로고
    • High-efficiency solid scintillation radioactivity detection for high-performance liquid chromatography
    • Mackey, L.N.; Rodriguez, P.A.; Schroeder, F.B. High-efficiency solid scintillation radioactivity detection for high-performance liquid chromatography. J. Chromatogr. 1981, 208, (1), 1-8.
    • (1981) J. Chromatogr , vol.208 , Issue.1 , pp. 1-8
    • Mackey, L.N.1    Rodriguez, P.A.2    Schroeder, F.B.3
  • 49
    • 45849093381 scopus 로고    scopus 로고
    • Kessler, M.J. A sensitive radioactivity detector for HPLC. Amer. Lab. 1982, 14, (8), 52, 54, 56, 58-60, 62-63.
    • Kessler, M.J. A sensitive radioactivity detector for HPLC. Amer. Lab. 1982, 14, (8), 52, 54, 56, 58-60, 62-63.
  • 50
    • 0020647708 scopus 로고
    • Quantitation of radiolabeled biological molecules separated by high-performance liquid chromatography
    • Kessler, M.J. Quantitation of radiolabeled biological molecules separated by high-performance liquid chromatography. J. Chromatogr. 1983, 255, 209-217.
    • (1983) J. Chromatogr , vol.255 , pp. 209-217
    • Kessler, M.J.1
  • 51
    • 45849113332 scopus 로고
    • 2 (Eu) scintillator for high-performance liquid chromatography
    • 2 (Eu) scintillator for high-performance liquid chromatography. J. Chromatogr. 1985, 333, (1), 83-92.
    • (1985) J. Chromatogr , vol.333 , Issue.1 , pp. 83-92
    • Nakamura, Y.1    Koizumi, Y.2
  • 52
    • 0345458441 scopus 로고
    • High performance liquid chromatography coupled with radioactivity detection: A powerful tool for determining drug metabolite profiles in biological fluids. Zeitschrift fuer Naturforschung, C
    • Vollmer, K.O.; Klemisch, W.; Von Hodenberg, A. High performance liquid chromatography coupled with radioactivity detection: A powerful tool for determining drug metabolite profiles in biological fluids. Zeitschrift fuer Naturforschung, C: J. Biosci. 1986, 41, (1-2), 115-125.
    • (1986) J. Biosci , vol.41 , Issue.1-2 , pp. 115-125
    • Vollmer, K.O.1    Klemisch, W.2    Von Hodenberg, A.3
  • 53
    • 0018588737 scopus 로고
    • High-pressure liquid chromatography coupled with a radioactivity detector: Investigation into the biotransformations of tritium and carbon-14 labeled compounds
    • Dugger, H.A.; Orwig, B.A. High-pressure liquid chromatography coupled with a radioactivity detector: Investigation into the biotransformations of tritium and carbon-14 labeled compounds. Drug Metab. Rev. 1979, 10, (2), 247-269.
    • (1979) Drug Metab. Rev , vol.10 , Issue.2 , pp. 247-269
    • Dugger, H.A.1    Orwig, B.A.2
  • 54
    • 0019881119 scopus 로고
    • Application of simultaneous UV radioactivity high-performance liquid chromatography to the study of intermediary metabolism. I. Purine nucleotides, nucleosides and bases
    • Webster, H.K.; Whaun, J.M. Application of simultaneous UV radioactivity high-performance liquid chromatography to the study of intermediary metabolism. I. Purine nucleotides, nucleosides and bases. J. Chromatogr. 1981, 209, (2), 283-292.
    • (1981) J. Chromatogr , vol.209 , Issue.2 , pp. 283-292
    • Webster, H.K.1    Whaun, J.M.2
  • 55
    • 0023586443 scopus 로고
    • HPLC analysis of [3H]-arachidonic acid metabolites produced by smooth muscle and endothelial cells in response to leukotriene D4
    • Clark, M.A.; Conway, T.M.; Crooke, S.T. HPLC analysis of [3H]-arachidonic acid metabolites produced by smooth muscle and endothelial cells in response to leukotriene D4. J. Liq. Chromatogr. 1987, 10, (12), 2707-2719.
    • (1987) J. Liq. Chromatogr , vol.10 , Issue.12 , pp. 2707-2719
    • Clark, M.A.1    Conway, T.M.2    Crooke, S.T.3
  • 56
    • 0037442578 scopus 로고    scopus 로고
    • On-line liquid chromatographyaccurate radioisotope counting coupled with a radioactivity detector and mass spectrometer for metabolite identification in drug discovery and development
    • Nassar, A.E.F.; Bjorge, S.M.; Lee, D.Y. On-line liquid chromatographyaccurate radioisotope counting coupled with a radioactivity detector and mass spectrometer for metabolite identification in drug discovery and development. Anal. Chem. 2003, 75, (4), 785-790.
    • (2003) Anal. Chem , vol.75 , Issue.4 , pp. 785-790
    • Nassar, A.E.F.1    Bjorge, S.M.2    Lee, D.Y.3
  • 57
    • 0025313250 scopus 로고
    • Direct and reverse flow-through heterogeneous scintillation counting of radiolabeled amino acids using post-column solvent segmentation
    • Veltkamp, A.C.; Das, H.A.; Brinkman, U.A.T. Direct and reverse flow-through heterogeneous scintillation counting of radiolabeled amino acids using post-column solvent segmentation. J. Chromatogr. 1990, 508, (2), 301-308.
    • (1990) J. Chromatogr , vol.508 , Issue.2 , pp. 301-308
    • Veltkamp, A.C.1    Das, H.A.2    Brinkman, U.A.T.3
  • 59
    • 0023794108 scopus 로고
    • 14C]-urapidil and its main metabolites in rat plasma, using post-column ion-pair extraction and solvent segmentation techniques
    • 14C]-urapidil and its main metabolites in rat plasma, using post-column ion-pair extraction and solvent segmentation techniques. J. Pharmaceut. Biomed. Anal. 1988, 6, (6-8), 609-622.
    • (1988) J. Pharmaceut. Biomed. Anal , vol.6 , Issue.6-8 , pp. 609-622
    • Veltkamp, A.C.1    Das, H.A.2    Frei, R.W.3    Brinkman, U.A.T.4
  • 60
    • 0024599326 scopus 로고
    • Determination of radiolabeled proline and hydroxyproline in collagen hydrolysates by high-performance liquid chromatography with on-line radiometric detection
    • Macek, J.; Lichy, A.; Pesakova, V.; Adam, M. Determination of radiolabeled proline and hydroxyproline in collagen hydrolysates by high-performance liquid chromatography with on-line radiometric detection. J. Chromatogr. 1989, 488, (1), 267-274.
    • (1989) J. Chromatogr , vol.488 , Issue.1 , pp. 267-274
    • Macek, J.1    Lichy, A.2    Pesakova, V.3    Adam, M.4
  • 61
    • 0020420184 scopus 로고
    • Synchronized accumulating radioisotope detector for high-performance liquid chromatography
    • Baba, S.; Horie, M.; Watanabe, K. Synchronized accumulating radioisotope detector for high-performance liquid chromatography. J. Chromatogr. 1982, 244, (1), 57-64.
    • (1982) J. Chromatogr , vol.244 , Issue.1 , pp. 57-64
    • Baba, S.1    Horie, M.2    Watanabe, K.3
  • 62
    • 45849144103 scopus 로고    scopus 로고
    • www.raytest.com
  • 63
    • 0006243868 scopus 로고    scopus 로고
    • Incorporation of a RAM cell in a microcolumn for on-column detection of radiolabeled molecules for LC-RAM-ESI-MS
    • Sep
    • Schultz, G.A.; Alexander, J.N., IV. Incorporation of a RAM cell in a microcolumn for on-column detection of radiolabeled molecules for LC-RAM-ESI-MS. J. Microcol. Sep. 1998, 10, (5), 431-437.
    • (1998) J. Microcol , vol.10 , Issue.5 , pp. 431-437
    • Schultz, G.A.1    Alexander, J.N.I.2
  • 64
    • 0033566025 scopus 로고    scopus 로고
    • Whole-column radioactivity detection: Simultaneous separation and enhanced detectability
    • Link, J.M.; Synovec, R.E. Whole-column radioactivity detection: Simultaneous separation and enhanced detectability. Anal. Chem. 1999, 71, (14), 2700-2707.
    • (1999) Anal. Chem , vol.71 , Issue.14 , pp. 2700-2707
    • Link, J.M.1    Synovec, R.E.2
  • 65
    • 0031059632 scopus 로고    scopus 로고
    • Narrow-bore liquid chromatography-tandem mass spectrometry with simultaneous radioactivity monitoring for partially characterizing the biliary metabolites of an arginine fluoroalkyl ketone analog of D-MePhe-Pro-Arg, a potent thrombin inhibitor
    • Heath, T.G.; Mooney, J.P.; Broersma, R. Narrow-bore liquid chromatography-tandem mass spectrometry with simultaneous radioactivity monitoring for partially characterizing the biliary metabolites of an arginine fluoroalkyl ketone analog of D-MePhe-Pro-Arg, a potent thrombin inhibitor. J. Chromatogr., B: Biomed. Appl. 1997, 688, (2), 281-289.
    • (1997) J. Chromatogr., B: Biomed. Appl , vol.688 , Issue.2 , pp. 281-289
    • Heath, T.G.1    Mooney, J.P.2    Broersma, R.3
  • 66
    • 0036099429 scopus 로고    scopus 로고
    • Radiochemical detection for packed capillary liquid chromatography-mass spectrometry
    • Onisko, B.C. Radiochemical detection for packed capillary liquid chromatography-mass spectrometry. J. Amer. Soc. Mass Spectrom. 2002, 13, (1), 82-84.
    • (2002) J. Amer. Soc. Mass Spectrom , vol.13 , Issue.1 , pp. 82-84
    • Onisko, B.C.1
  • 67
    • 0036027838 scopus 로고    scopus 로고
    • Comparison of heterogeneous and homogeneous radioactivity flow detectors for simultaneous profiling and LC-MS/MS characterization of metabolites
    • Egnash, L.A.; Ramanathan, R. Comparison of heterogeneous and homogeneous radioactivity flow detectors for simultaneous profiling and LC-MS/MS characterization of metabolites. J. Pharmaceut. Biomed. Anal. 2002, 27, (1-2), 271-284.
    • (2002) J. Pharmaceut. Biomed. Anal , vol.27 , Issue.1-2 , pp. 271-284
    • Egnash, L.A.1    Ramanathan, R.2
  • 68
    • 45849124283 scopus 로고    scopus 로고
    • www.stopflow.com
  • 69
    • 33947160983 scopus 로고    scopus 로고
    • Novel approach to performing metabolite identification in drug metabolism
    • Nassar, A.-E.F.; Lee, D.Y. Novel approach to performing metabolite identification in drug metabolism. J. Chromatogr. Sci. 2007, 45, 113-119.
    • (2007) J. Chromatogr. Sci , vol.45 , pp. 113-119
    • Nassar, A.-E.F.1    Lee, D.Y.2
  • 70
    • 0034663268 scopus 로고    scopus 로고
    • Use of a microplate scintillation counter as a radioactive detector for miniaturized separtion techniques in drug metabolism
    • Boernsen, K.O.; Floeckher, J.M.; Bruin, G.J.M. Use of a microplate scintillation counter as a radioactive detector for miniaturized separtion techniques in drug metabolism. Anal. Chem. 2000, 72, (16), 3956-3959.
    • (2000) Anal. Chem , vol.72 , Issue.16 , pp. 3956-3959
    • Boernsen, K.O.1    Floeckher, J.M.2    Bruin, G.J.M.3
  • 71
    • 23444454671 scopus 로고    scopus 로고
    • Analysis of low level radioactive metabolites in biological fluids using high-performance liquid chromatography with microplate scintillation counting: Method validation and application
    • Zhu, M.; Zhao, W; Vazquez, N; Mitroka, J.G. Analysis of low level radioactive metabolites in biological fluids using high-performance liquid chromatography with microplate scintillation counting: method validation and application. J. Pharm. Biomed. Anal. 2005, 39, 233-245.
    • (2005) J. Pharm. Biomed. Anal , vol.39 , pp. 233-245
    • Zhu, M.1    Zhao, W.2    Vazquez, N.3    Mitroka, J.G.4
  • 72
    • 33846019976 scopus 로고    scopus 로고
    • TopCount coupled to ultra-performance liquid chromatography for the profiling of radiolabeld drug metabolites in complex biological samples
    • Dear, G.J.; Patel, N.; Kelly, P.J.; Webber, L.; Yung, M. TopCount coupled to ultra-performance liquid chromatography for the profiling of radiolabeld drug metabolites in complex biological samples. J. Chromatogr. B 2006, 844, 96-103.
    • (2006) J. Chromatogr. B , vol.844 , pp. 96-103
    • Dear, G.J.1    Patel, N.2    Kelly, P.J.3    Webber, L.4    Yung, M.5
  • 73
    • 0037442597 scopus 로고    scopus 로고
    • Combination of high-performance liquid chromatography and microplate scintillation counting for crop and animal metabolism studies: A comparison with classical on-line and thin-layer chromatography radioactivity detection
    • Kiffe, M.; Jehle, A.; Ruembeli, R. Combination of high-performance liquid chromatography and microplate scintillation counting for crop and animal metabolism studies: A comparison with classical on-line and thin-layer chromatography radioactivity detection. Anal. Chem. 2003, 75, 723-730.
    • (2003) Anal. Chem , vol.75 , pp. 723-730
    • Kiffe, M.1    Jehle, A.2    Ruembeli, R.3
  • 74
    • 0842281553 scopus 로고    scopus 로고
    • The use of 96-well Scintplates to facilitate definitive metabolism studies for drug candidates
    • Nedderman, A.N.R.; Savage, M.E.; White, K.L.; Walker, D.K. The use of 96-well Scintplates to facilitate definitive metabolism studies for drug candidates. J. Pharm. Biomed. Anal. 2004, 34, 607-617.
    • (2004) J. Pharm. Biomed. Anal , vol.34 , pp. 607-617
    • Nedderman, A.N.R.1    Savage, M.E.2    White, K.L.3    Walker, D.K.4
  • 75
    • 34250696563 scopus 로고    scopus 로고
    • Cytostar-T plates - A valid alternative for microplate scintillation counting of low radioactivity in combination with high-performance liquid chromatography in drug metabolism studies?
    • Kiffe, M.; Nufer, R.; Trunzer, M.; Graf, D. Cytostar-T plates - A valid alternative for microplate scintillation counting of low radioactivity in combination with high-performance liquid chromatography in drug metabolism studies? J. Chromatogr. A 2007, 1157, (1-2), 65-72.
    • (2007) J. Chromatogr. A , vol.1157 , Issue.1-2 , pp. 65-72
    • Kiffe, M.1    Nufer, R.2    Trunzer, M.3    Graf, D.4
  • 76
    • 33947234593 scopus 로고    scopus 로고
    • Two-dimensional liquid chromatography/ mass spectrometry set-up for structural elucidation of metabolites in complex biological matrices
    • Kiffe, M.; Graf, D.; Trunzer, M. Two-dimensional liquid chromatography/ mass spectrometry set-up for structural elucidation of metabolites in complex biological matrices. Rapid Commun. Mass Spectrom. 2007, 21, 961-970.
    • (2007) Rapid Commun. Mass Spectrom , vol.21 , pp. 961-970
    • Kiffe, M.1    Graf, D.2    Trunzer, M.3
  • 77
    • 0037365932 scopus 로고    scopus 로고
    • Big physics, small doses: The use of AMS and PET in human microdosing of development drugs
    • Lappin, G.; Garner, R.C. Big physics, small doses: the use of AMS and PET in human microdosing of development drugs. Nature Rev. 2003, 2, 233-240.
    • (2003) Nature Rev , vol.2 , pp. 233-240
    • Lappin, G.1    Garner, R.C.2
  • 78
    • 0033059135 scopus 로고    scopus 로고
    • Biomedical applications of accelerator mass spectrometry - isotope measurements at the level of the atom
    • Barker, J.; Garner, R.C. Biomedical applications of accelerator mass spectrometry - isotope measurements at the level of the atom. Rapid Comm. Mass Spectrom. 1999, 13, 285-293.
    • (1999) Rapid Comm. Mass Spectrom , vol.13 , pp. 285-293
    • Barker, J.1    Garner, R.C.2
  • 79
    • 33748361948 scopus 로고    scopus 로고
    • The use of accelerator mass spectrometry to obtain early human ADME/PK data. Expert Opin. Drug Metab
    • Lappin, G.; Garner, R.C. The use of accelerator mass spectrometry to obtain early human ADME/PK data. Expert Opin. Drug Metab. Toxicol. 2005, 1, 23-31.
    • (2005) Toxicol , vol.1 , pp. 23-31
    • Lappin, G.1    Garner, R.C.2
  • 80
    • 0035987901 scopus 로고    scopus 로고
    • 14C-labeled (R)-6-[Amino(4-chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl] -4-(3-chlorophenyl)-1-methyl-2(1H)-quinolinone (R115777), a farnesyl transferase inhibitor. Drug Metab. Disp. 2002, 30, 823-830.
    • 14C-labeled (R)-6-[Amino(4-chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl] -4-(3-chlorophenyl)-1-methyl-2(1H)-quinolinone (R115777), a farnesyl transferase inhibitor. Drug Metab. Disp. 2002, 30, 823-830.
  • 81
    • 0034281129 scopus 로고    scopus 로고
    • Accelerator mass spectrometry in pharmaceutical research and development - a new ultrasensitive analytical method for isotope measurement
    • Garner, R.C. Accelerator mass spectrometry in pharmaceutical research and development - a new ultrasensitive analytical method for isotope measurement. Curr. Drug Metab. 2000, 1, 205-213.
    • (2000) Curr. Drug Metab , vol.1 , pp. 205-213
    • Garner, R.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.