Volumn 3, Issue , 2004, Pages 2444-2447

Near-field scanning microwave microscopy for detection of subsurface biological anomalies

Author keywords

[No Author keywords available]

Indexed keywords

MICROWAVE RESONATOR; NEAR-FIELD SUBSURFACE MICROWAVE MICROSCOPY (NSMM); SPATIAL RESOLUTION; SURFACE DETECTION;

EID: 4544311573     PISSN: 15223965     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 2
    • 0000769683 scopus 로고    scopus 로고
    • High spatial resolution quantitative microwave impedance microscopy by a scanning tip microwave near-field microscope
    • Sept.
    • C. Gao, T. Wei, F. Duewer, Y. Lu and X. -D. Xiang, "High spatial resolution quantitative microwave impedance microscopy by a scanning tip microwave near-field microscope," Appl. Phys. Lett., vol. 71, no.13, pp. 1872-1874, Sept. 1997.
    • (1997) Appl. Phys. Lett. , vol.71 , Issue.13 , pp. 1872-1874
    • Gao, C.1    Wei, T.2    Duewer, F.3    Lu, Y.4    Xiang, X.D.5
  • 3
    • 21944445641 scopus 로고    scopus 로고
    • Combined millimeter-wave near-field microscope and capacitance distance control for the quantitative mapping of sheet resistance of conducting layers
    • Nov.
    • A. F. Lann, M. Golosovsky, D. Davidov and A. Frenkel, "Combined millimeter-wave near-field microscope and capacitance distance control for the quantitative mapping of sheet resistance of conducting layers," Appl. Phys. Lett., vol. 73, no. 19, pp. 2832-2835, Nov. 1998.
    • (1998) Appl. Phys. Lett. , vol.73 , Issue.19 , pp. 2832-2835
    • Lann, A.F.1    Golosovsky, M.2    Davidov, D.3    Frenkel, A.4
  • 4
    • 0000174723 scopus 로고    scopus 로고
    • Tip-sample distance feedback control in a scanning evanescent microwve microscope
    • May.
    • F. Duewer, C. Gao, I. Takeuchi, and X.-D. Xiang, "Tip-sample distance feedback control in a scanning evanescent microwve microscope," Appl. Phys. Lett., vol. 74, no. 18, pp. 2696-2699, May. 1999.
    • (1999) Appl. Phys. Lett. , vol.74 , Issue.18 , pp. 2696-2699
    • Duewer, F.1    Gao, C.2    Takeuchi, I.3    Xiang, X.-D.4
  • 5
    • 79956038753 scopus 로고    scopus 로고
    • Improved surface imaging with a near-field scanning microwave microscope using a tunable resonator
    • Jan.
    • S. Hong, J. Kirn w. Park, and K. Lee, "Improved surface imaging with a near-field scanning microwave microscope using a tunable resonator," Appl. Phys. Lett., vol. 80, no. 3, pp.524-526, Jan. 2002.
    • (2002) Appl. Phys. Lett. , vol.80 , Issue.3 , pp. 524-526
    • Hong, S.1    Kirn, J.2    Park, W.3    Lee, K.4
  • 8
    • 0023919699 scopus 로고
    • Non-palpable breast-lesions: Recommendation for biopsy based on suspicion of carcinoma at mammography
    • F. M. Hall, J. M. Storella, D. Z. Silverstone, and G. Wyshak, "Non-palpable breast-lesions: Recommendation for biopsy based on suspicion of carcinoma at mammography," Radiol., vol. 167, no. 2, pp.353-358, 1988.
    • (1988) Radiol. , vol.167 , Issue.2 , pp. 353-358
    • Hall, F.M.1    Storella, J.M.2    Silverstone, D.Z.3    Wyshak, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.