-
1
-
-
44949138475
-
-
Group T.L. (Ed), Advanced Medical Technology Association, Falls Church, Virginia
-
Bailey P.G. In: Group T.L. (Ed). Advamed-The Medical Technology Industry at a Glance (2004), Advanced Medical Technology Association, Falls Church, Virginia 37
-
(2004)
Advamed-The Medical Technology Industry at a Glance
, pp. 37
-
-
Bailey, P.G.1
-
2
-
-
0033567865
-
Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
-
Baker D.A., Hastings R.S., and Pruitt L. Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J. Biomed. Mater. Res. 46 4 (1999) 573-581
-
(1999)
J. Biomed. Mater. Res.
, vol.46
, Issue.4
, pp. 573-581
-
-
Baker, D.A.1
Hastings, R.S.2
Pruitt, L.3
-
3
-
-
0027575844
-
Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene
-
Cooper J.R., Dowson D., and Fisher J. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene. Wear 162-164 Part 1 (1993) 378-384
-
(1993)
Wear
, vol.162-164
, Issue.PART 1
, pp. 378-384
-
-
Cooper, J.R.1
Dowson, D.2
Fisher, J.3
-
4
-
-
0031626848
-
In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses
-
Proceedings of the Institution of Mechanical Engineers. Part H
-
Currier J.H., et al. In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses. Proceedings of the Institution of Mechanical Engineers. Part H. J. Eng. Med. 212 4 (1998) 293-302
-
(1998)
J. Eng. Med.
, vol.212
, Issue.4
, pp. 293-302
-
-
Currier, J.H.1
-
5
-
-
0028264489
-
Wear of ultra high molecular weight polyethylene in total artificial joints
-
Fisher J. Wear of ultra high molecular weight polyethylene in total artificial joints. Curr. Orthop. 8 3 (1994) 164-169
-
(1994)
Curr. Orthop.
, vol.8
, Issue.3
, pp. 164-169
-
-
Fisher, J.1
-
6
-
-
0019364909
-
The deformation and wear of plastic components in artificial knee joints; an experimental study
-
Walker P.S., et al. The deformation and wear of plastic components in artificial knee joints; an experimental study. Eng. Med. 10 1 (1981) 33-38
-
(1981)
Eng. Med.
, vol.10
, Issue.1
, pp. 33-38
-
-
Walker, P.S.1
-
8
-
-
0345168808
-
The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR
-
Elfick A.P.D., et al. The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR. J. Biomed. Mater. Res. 65A 1 (2003) 95-108
-
(2003)
J. Biomed. Mater. Res.
, vol.65 A
, Issue.1
, pp. 95-108
-
-
Elfick, A.P.D.1
-
10
-
-
0027234537
-
The synovial response to intraarticular injection in rats of polyethylene wear particles
-
Howie D.W., et al. The synovial response to intraarticular injection in rats of polyethylene wear particles. Clin. Orthop. Relat. Res. 292 (1993) 352-357
-
(1993)
Clin. Orthop. Relat. Res.
, vol.292
, pp. 352-357
-
-
Howie, D.W.1
-
11
-
-
0023860303
-
A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles
-
Howie D.W., et al. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J. Bone Joint Surg. Am. 70 2 (1988) 257-263
-
(1988)
J. Bone Joint Surg. Am.
, vol.70
, Issue.2
, pp. 257-263
-
-
Howie, D.W.1
-
12
-
-
0026518203
-
Wear particles of total joint replacements and their role in periprosthetic osteolysis
-
Jasty M., and Smith E. Wear particles of total joint replacements and their role in periprosthetic osteolysis. Curr. Opin. Rheumatol. 4 2 (1992) 204-209
-
(1992)
Curr. Opin. Rheumatol.
, vol.4
, Issue.2
, pp. 204-209
-
-
Jasty, M.1
Smith, E.2
-
13
-
-
0026356990
-
Catastrophic wear of tibial polyethylene inserts
-
Kilgus D.J., et al. Catastrophic wear of tibial polyethylene inserts. Clin. Orthop. Relat. Res. 273 (1991) 223-231
-
(1991)
Clin. Orthop. Relat. Res.
, vol.273
, pp. 223-231
-
-
Kilgus, D.J.1
-
14
-
-
0032401792
-
Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro
-
Green T.R., et al. Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. Biomaterials 19 24 (1998) 2297-2302
-
(1998)
Biomaterials
, vol.19
, Issue.24
, pp. 2297-2302
-
-
Green, T.R.1
-
15
-
-
0033628937
-
Biological reactions to wear debris in total joint replacement
-
Proceedings of the Institution of Mechanical Engineers. Part H
-
Ingham E., and Fisher J. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers. Part H. J. Eng. Med. 214 1 (2000) 21-37
-
(2000)
J. Eng. Med.
, vol.214
, Issue.1
, pp. 21-37
-
-
Ingham, E.1
Fisher, J.2
-
16
-
-
0033490061
-
A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement
-
Wang A., et al. A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement. Wear 225-229 Part 2 (1999) 701-707
-
(1999)
Wear
, vol.225-229
, Issue.PART 2
, pp. 701-707
-
-
Wang, A.1
-
17
-
-
0031059923
-
A knee simulating machine for performance evaluation of total knee replacements
-
Walker P.S., et al. A knee simulating machine for performance evaluation of total knee replacements. J. Biomech. 30 1 (1997) 83-89
-
(1997)
J. Biomech.
, vol.30
, Issue.1
, pp. 83-89
-
-
Walker, P.S.1
-
18
-
-
0042063879
-
In vitro lateral versus medial wear of a knee prosthesis
-
Laurent M.P., et al. In vitro lateral versus medial wear of a knee prosthesis. Wear 255 7-12 (2003) 1101-1106
-
(2003)
Wear
, vol.255
, Issue.7-12
, pp. 1101-1106
-
-
Laurent, M.P.1
-
19
-
-
0041562682
-
Comparison of wear of mobile and fixed bearing knees tested in a knee simulator
-
Johnson T.S., et al. Comparison of wear of mobile and fixed bearing knees tested in a knee simulator. Wear 255 7-12 (2003) 1107-1112
-
(2003)
Wear
, vol.255
, Issue.7-12
, pp. 1107-1112
-
-
Johnson, T.S.1
-
20
-
-
0030630960
-
Development of a six station knee wear simulator and preliminary wear results
-
Proceedings of the Institution of Mechanical Engineers. Part H
-
Burgess I.C., et al. Development of a six station knee wear simulator and preliminary wear results. Proceedings of the Institution of Mechanical Engineers. Part H. J. Eng. Med. 211 1 (1997) 37-47
-
(1997)
J. Eng. Med.
, vol.211
, Issue.1
, pp. 37-47
-
-
Burgess, I.C.1
-
21
-
-
0036699419
-
Simulation of wear rates and mechanisms in total knee prostheses by ball-on-flat contact in a five-station, three-axis test rig
-
Saikko V., and Calonius O. Simulation of wear rates and mechanisms in total knee prostheses by ball-on-flat contact in a five-station, three-axis test rig. Wear 253 3/4 (2002) 424-429
-
(2002)
Wear
, vol.253
, Issue.3-4
, pp. 424-429
-
-
Saikko, V.1
Calonius, O.2
-
22
-
-
0037024111
-
Polyethylene wear characteristics in vivo and in a knee stimulator
-
Beaule P.E., et al. Polyethylene wear characteristics in vivo and in a knee stimulator. J. Biomed. Mater. Res. 60 3 (2002) 411-419
-
(2002)
J. Biomed. Mater. Res.
, vol.60
, Issue.3
, pp. 411-419
-
-
Beaule, P.E.1
-
23
-
-
44949242649
-
Long-term durability testing of total knee replacements in a simulating machine.
-
European Society for Biomaterials, Toulouse, France
-
Walker P.S. Long-term durability testing of total knee replacements in a simulating machine. Proceedings of the 11th Conference of the ESB (1998), European Society for Biomaterials, Toulouse, France
-
(1998)
Proceedings of the 11th Conference of the ESB
-
-
Walker, P.S.1
-
24
-
-
2142716777
-
A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses
-
Proceedings of the Institution of Mechanical Engineers
-
McGloughlin T.M., Murphy D.M., and Kavanagh A.G. A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses. Proceedings of the Institution of Mechanical Engineers. J. Eng. Med. 218 1 (2004) 51-62
-
(2004)
J. Eng. Med.
, vol.218
, Issue.1
, pp. 51-62
-
-
McGloughlin, T.M.1
Murphy, D.M.2
Kavanagh, A.G.3
-
25
-
-
0014698584
-
The mechanics of the knee joint in relation to normal walking
-
Morrison J.B. The mechanics of the knee joint in relation to normal walking. J. Biomech. 3 1 (1970) 51-61
-
(1970)
J. Biomech.
, vol.3
, Issue.1
, pp. 51-61
-
-
Morrison, J.B.1
-
26
-
-
0018004506
-
Wear and its measurement for joint prosthesis materials
-
Dumbleton J.H. Wear and its measurement for joint prosthesis materials. Wear 49 2 (1978) 297-326
-
(1978)
Wear
, vol.49
, Issue.2
, pp. 297-326
-
-
Dumbleton, J.H.1
-
27
-
-
0034512161
-
Long-term results for Kinemax and Kinematic knee bearings on a six-station knee wear simulator
-
Proceedings of the Institution of Mechanical Engineers
-
Ash H.E., Burgess I.C., and Unsworth A. Long-term results for Kinemax and Kinematic knee bearings on a six-station knee wear simulator. Proceedings of the Institution of Mechanical Engineers. J. Eng. Med. 214 5 (2000) 437-447
-
(2000)
J. Eng. Med.
, vol.214
, Issue.5
, pp. 437-447
-
-
Ash, H.E.1
Burgess, I.C.2
Unsworth, A.3
-
28
-
-
4644220738
-
Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts
-
Muratoglu O.K., et al. Knee-simulator testing of conventional and cross-linked polyethylene tibial inserts. J. Arthroplasty 19 7 (2004) 887-897
-
(2004)
J. Arthroplasty
, vol.19
, Issue.7
, pp. 887-897
-
-
Muratoglu, O.K.1
-
29
-
-
0019596289
-
Wear of artificial joint materials. III. Simulation of the knee joint using a computer-controlled system
-
Treharne R.W., Young R.W., and Young S.R. Wear of artificial joint materials. III. Simulation of the knee joint using a computer-controlled system. Eng. Med. 10 3 (1981) 137-142
-
(1981)
Eng. Med.
, vol.10
, Issue.3
, pp. 137-142
-
-
Treharne, R.W.1
Young, R.W.2
Young, S.R.3
-
30
-
-
0029725748
-
Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
-
Proceedings of the Institution of Mechanical Engineers
-
Wang A., Stark C., and Dumbleton J.H. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proceedings of the Institution of Mechanical Engineers. J. Eng. Med. 210 3 (1996) 141-155
-
(1996)
J. Eng. Med.
, vol.210
, Issue.3
, pp. 141-155
-
-
Wang, A.1
Stark, C.2
Dumbleton, J.H.3
-
31
-
-
44949128251
-
Knee simulator testing in a clinically relevant TKR lubricant
-
Orthopaedic Research Society (ORS), Washington, DC
-
Aurora A., et al. Knee simulator testing in a clinically relevant TKR lubricant. Presentation at the 51st Annual Meeting (2005), Orthopaedic Research Society (ORS), Washington, DC
-
(2005)
Presentation at the 51st Annual Meeting
-
-
Aurora, A.1
-
32
-
-
44949230374
-
-
ASTM F732-00, Standard Test Method of Polymeric Materials Used in Total Joint Prostheses, American Society for Testing and Materials, 2004.
-
ASTM F732-00, Standard Test Method of Polymeric Materials Used in Total Joint Prostheses, American Society for Testing and Materials, 2004.
-
-
-
-
33
-
-
44949185682
-
-
ASTM F1715-00, Standard Guide for Wear Assessment of Prosthetic Knee Designs in Simulator Devices, American Society for Testing and Materials, 2004.
-
ASTM F1715-00, Standard Guide for Wear Assessment of Prosthetic Knee Designs in Simulator Devices, American Society for Testing and Materials, 2004.
-
-
-
-
35
-
-
4444308708
-
The effect of bone cement particles on the friction of polyethylene and polyurethane knee bearings
-
Ash H.E., et al. The effect of bone cement particles on the friction of polyethylene and polyurethane knee bearings. Phys. Med. Biol. 49 15 (2004) 3413-3425
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.15
, pp. 3413-3425
-
-
Ash, H.E.1
-
36
-
-
0031886313
-
Quantitative assessment of walking activity after total hip or knee replacement
-
Schmalzried T.P., et al. Quantitative assessment of walking activity after total hip or knee replacement. J. Bone Joint Surg. Ser. A 80 1 (1998) 54-59
-
(1998)
J. Bone Joint Surg. Ser. A
, vol.80
, Issue.1
, pp. 54-59
-
-
Schmalzried, T.P.1
-
37
-
-
0032443741
-
Assessing activity in joint replacement patients
-
Zahiri C.A., et al. Assessing activity in joint replacement patients. J. Arthroplasty 13 8 (1998) 890-895
-
(1998)
J. Arthroplasty
, vol.13
, Issue.8
, pp. 890-895
-
-
Zahiri, C.A.1
-
38
-
-
44949240684
-
Measurement of creep in ultra high molecular weight polyethylene (UHMWPE): comparison of conventional UHMWPE V's a highly cross-linked polyethylene
-
Orthopaedic Research Society, Orlando, Florida
-
Estok D.M., et al. Measurement of creep in ultra high molecular weight polyethylene (UHMWPE): comparison of conventional UHMWPE V's a highly cross-linked polyethylene. Transactions of the 46th Orthopaedic Research Society Meeting (2000), Orthopaedic Research Society, Orlando, Florida
-
(2000)
Transactions of the 46th Orthopaedic Research Society Meeting
-
-
Estok, D.M.1
-
39
-
-
24944463697
-
Highly cross-linked polyethylene: the debate is over-in the affirmative
-
Jasty M., Rubash H.E., and Muratoglu O. Highly cross-linked polyethylene: the debate is over-in the affirmative. J. Arthroplasty 20 4, Suppl. 2 (2005) 55-58
-
(2005)
J. Arthroplasty
, vol.20
, Issue.4 SUPPL. 2
, pp. 55-58
-
-
Jasty, M.1
Rubash, H.E.2
Muratoglu, O.3
-
40
-
-
0033252596
-
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
-
Proceedings of the Institution of Mechanical Engineers
-
Barbour P.S., Stone M.H., and Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Proceedings of the Institution of Mechanical Engineers. J. Eng. Med. 213 6 (1999) 455-467
-
(1999)
J. Eng. Med.
, vol.213
, Issue.6
, pp. 455-467
-
-
Barbour, P.S.1
Stone, M.H.2
Fisher, J.3
-
41
-
-
33746282741
-
Clinical performance of contemporary tibial polyethylene components
-
Crowninshield R.D., et al. Clinical performance of contemporary tibial polyethylene components. J. Arthroplasty 21 5 (2006) 754-761
-
(2006)
J. Arthroplasty
, vol.21
, Issue.5
, pp. 754-761
-
-
Crowninshield, R.D.1
-
42
-
-
0037268741
-
Polyethylene damage in total knees and use of highly crosslinked polyethylene
-
Muratoglu O.K., et al. Polyethylene damage in total knees and use of highly crosslinked polyethylene. J. Bone Joint Surg. Ser. A 85 Suppl. 2 (2003) 7-13
-
(2003)
J. Bone Joint Surg. Ser. A
, vol.85
, Issue.SUPPL. 2
, pp. 7-13
-
-
Muratoglu, O.K.1
-
43
-
-
0033627424
-
Wear testing of UHMWPE tibial components: influence of oxidation
-
Young S.K., et al. Wear testing of UHMWPE tibial components: influence of oxidation. J. Tribol. -Trans. ASME 122 1 (2000) 323-331
-
(2000)
J. Tribol. -Trans. ASME
, vol.122
, Issue.1
, pp. 323-331
-
-
Young, S.K.1
-
44
-
-
0343298342
-
-
Willert H.-G., Buchhorn G.H., and Eyerer P. (Eds), Hogrefe and Huber Publishers, Toronto, Ontario
-
Wright T.M., and Rimnac C.M. In: Willert H.-G., Buchhorn G.H., and Eyerer P. (Eds). Analysis of Retrieved Polyethylene Components from Total Joint Replacements, in Ultra High Molecular Weight Polyethylene as Biomaterial in Orthopedic Surgery (1991), Hogrefe and Huber Publishers, Toronto, Ontario 202-207
-
(1991)
Analysis of Retrieved Polyethylene Components from Total Joint Replacements, in Ultra High Molecular Weight Polyethylene as Biomaterial in Orthopedic Surgery
, pp. 202-207
-
-
Wright, T.M.1
Rimnac, C.M.2
-
45
-
-
44949187653
-
Wear in metal-plastic joint replacements
-
ESSKA, Berlin, Germany
-
Pappas M.J., and Buechel Sr. F.F. Wear in metal-plastic joint replacements. Congress of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA) (1994), ESSKA, Berlin, Germany
-
(1994)
Congress of the European Society of Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA)
-
-
Pappas, M.J.1
Buechel Sr., F.F.2
-
47
-
-
0035743211
-
Wear of polyethylene in artificial knee joints
-
Fisher J., et al. Wear of polyethylene in artificial knee joints. Curr. Orthop. 15 6 (2001) 399-405
-
(2001)
Curr. Orthop.
, vol.15
, Issue.6
, pp. 399-405
-
-
Fisher, J.1
-
48
-
-
0031544587
-
Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses
-
Blunn G.W., et al. Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. J. Arthroplasty 12 3 (1997) 281-290
-
(1997)
J. Arthroplasty
, vol.12
, Issue.3
, pp. 281-290
-
-
Blunn, G.W.1
-
49
-
-
23044439718
-
Premature failure of the polyethylene tibial bearing surface of the Interax knee arthroplasty
-
Sugimoto K., et al. Premature failure of the polyethylene tibial bearing surface of the Interax knee arthroplasty. J. Arthroplasty 20 5 (2005) 658-663
-
(2005)
J. Arthroplasty
, vol.20
, Issue.5
, pp. 658-663
-
-
Sugimoto, K.1
-
50
-
-
44949205631
-
Long-term durability testing of total knee replacements in a simulating machine
-
p. 111
-
Walker P.S., et al. Long-term durability testing of total knee replacements in a simulating machine. J. Biomech. 31 Suppl. 1 (1998) p. 111
-
(1998)
J. Biomech.
, vol.31
, Issue.SUPPL. 1
-
-
Walker, P.S.1
-
51
-
-
0036743025
-
Ultra high molecular-weight polyethylene (UHMWPE) in total knee replacement: fabrication, sterilisation and wear
-
Blunn G., et al. Ultra high molecular-weight polyethylene (UHMWPE) in total knee replacement: fabrication, sterilisation and wear. J. Bone Joint Surg. Br. 84 7 (2002) 946-949
-
(2002)
J. Bone Joint Surg. Br.
, vol.84
, Issue.7
, pp. 946-949
-
-
Blunn, G.1
-
52
-
-
0035236106
-
The effect of kinematic conditions on the wear of ultra-high molecular weight polyethylene (UHMWPE) in orthopaedic bearing applications
-
Proceedings of the Institution of Mechanical Engineers
-
Cornwall G.B., Bryant J.T., and Hansson C.M. The effect of kinematic conditions on the wear of ultra-high molecular weight polyethylene (UHMWPE) in orthopaedic bearing applications. Proceedings of the Institution of Mechanical Engineers. J. Eng. Med. 215 1 (2001) 95-106
-
(2001)
J. Eng. Med.
, vol.215
, Issue.1
, pp. 95-106
-
-
Cornwall, G.B.1
Bryant, J.T.2
Hansson, C.M.3
-
53
-
-
0036849841
-
The causes of insert backside wear in total knee arthroplasty
-
Wasielewski R.C. The causes of insert backside wear in total knee arthroplasty. Clin. Orthop. Relat. Res. 404 (2002) 232-246
-
(2002)
Clin. Orthop. Relat. Res.
, vol.404
, pp. 232-246
-
-
Wasielewski, R.C.1
-
54
-
-
0036849792
-
Assessment of backside wear from the analysis of 55 retrieved tibial inserts
-
Li S., et al. Assessment of backside wear from the analysis of 55 retrieved tibial inserts. Clin. Orthop. Relat. Res. 404 (2002) 75-82
-
(2002)
Clin. Orthop. Relat. Res.
, vol.404
, pp. 75-82
-
-
Li, S.1
-
55
-
-
2442490781
-
Backside wear of modular ultra-high molecular weight polyethylene tibial inserts
-
Conditt M.A., et al. Backside wear of modular ultra-high molecular weight polyethylene tibial inserts. J. Bone Joint Surg. Am. 86-A 5 (2004) 1031-1037
-
(2004)
J. Bone Joint Surg. Am.
, vol.86 -A
, Issue.5
, pp. 1031-1037
-
-
Conditt, M.A.1
-
56
-
-
0038743250
-
Polyethylene damage on the nonarticular surface of modular total knee prostheses
-
Cuckler J.M., et al. Polyethylene damage on the nonarticular surface of modular total knee prostheses. Clin. Orthop. Relat. Res. 410 (2003) 248-253
-
(2003)
Clin. Orthop. Relat. Res.
, vol.410
, pp. 248-253
-
-
Cuckler, J.M.1
-
57
-
-
20844436635
-
The significance of surface changes on retrieved femoral components after total knee replacement
-
Lakdawala A., Todo S., and Scott G. The significance of surface changes on retrieved femoral components after total knee replacement. J. Bone Joint Surg. Br. 87 6 (2005) 796-799
-
(2005)
J. Bone Joint Surg. Br.
, vol.87
, Issue.6
, pp. 796-799
-
-
Lakdawala, A.1
Todo, S.2
Scott, G.3
-
58
-
-
0031594091
-
Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
-
Wang A., et al. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribol. Int. 31 1-3 (1998) 17-33
-
(1998)
Tribol. Int.
, vol.31
, Issue.1-3
, pp. 17-33
-
-
Wang, A.1
-
59
-
-
0346725975
-
The effects of lubricant composition on in vitro wear testing of polymeric acetabular components. Part B
-
Wang A., Essner A., and Schmidig G. The effects of lubricant composition on in vitro wear testing of polymeric acetabular components. Part B. J. Biomed. Mater. Res. Part B. Appl. Biomater. 68 1 (2004) 45-52
-
(2004)
J. Biomed. Mater. Res. Part B. Appl. Biomater.
, vol.68
, Issue.1
, pp. 45-52
-
-
Wang, A.1
Essner, A.2
Schmidig, G.3
|