메뉴 건너뛰기




Volumn 225-229, Issue PART II, 1999, Pages 701-707

A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement

Author keywords

Biaxial line contact wear machine; Knee joint simulator; Total knee joint replacement; UHMWPE

Indexed keywords

BEARINGS (MACHINE PARTS); INTERFACES (MATERIALS); JOINT PROSTHESES; KINEMATICS; MACHINE DESIGN; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES;

EID: 0033490061     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0043-1648(99)00025-3     Document Type: Article
Times cited : (15)

References (21)
  • 3
    • 0028798063 scopus 로고
    • The problem is osteolysis
    • W.H. Harris, The problem is osteolysis, Clin. Orthop. Rel. Res. 311 (1995) 46-53.
    • (1995) Clin. Orthop. Rel. Res. , vol.311 , pp. 46-53
    • Harris, W.H.1
  • 5
    • 0023697318 scopus 로고
    • Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
    • M.M. Landy, P.A. Walker, Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses, J. Arthroplasty (Supplement) 3 (1988) S73-85.
    • (1988) J. Arthroplasty (Supplement) , vol.3
    • Landy, M.M.1    Walker, P.A.2
  • 6
    • 0031099405 scopus 로고    scopus 로고
    • The significance of nonlinear motion in the wear screening of orthopaedic implant materials
    • A. Wang, V.K. Polineni, A. Essner et al., The significance of nonlinear motion in the wear screening of orthopaedic implant materials, J. Testing Eval. 25 (2) (1997) 239-245.
    • (1997) J. Testing Eval. , vol.25 , Issue.2 , pp. 239-245
    • Wang, A.1    Polineni, V.K.2    Essner, A.3
  • 8
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • A. Wang, C. Stark, J.H. Dumbleton, Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses, Proc. Instn. Mech. Engrs., Part H: J. Eng. Med. 210 (1996) 141-155.
    • (1996) Proc. Instn. Mech. Engrs., Part H: J. Eng. Med. , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 9
    • 0006544376 scopus 로고    scopus 로고
    • Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene
    • A. Wang, D.C. Sun, S.-S. Yau et al., Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene, Wear 203-204 (1997) 230-241.
    • (1997) Wear , vol.203-204 , pp. 230-241
    • Wang, A.1    Sun, D.C.2    Yau, S.-S.3
  • 11
    • 0032126428 scopus 로고    scopus 로고
    • A realistic pin-on-disk wear test method for prosthetic joint materials
    • in print
    • V. Saikko, A realistic pin-on-disk wear test method for prosthetic joint materials, J. Biomed. Mater. Res., 1998 (in print).
    • (1998) J. Biomed. Mater. Res.
    • Saikko, V.1
  • 12
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • D.L. Bartel, A.H. Burstein, M.D. Toda, D.L. Edwards, The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants, J. Biomech. Eng. 107 (1985) 113.
    • (1985) J. Biomech. Eng. , vol.107 , pp. 113
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 13
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE m total joint replacements
    • A. Wang, D.C. Sun, C. Stark, J.H. Dumbleton, Wear mechanisms of UHMWPE m total joint replacements, Wear 181-183 (1995) 241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 17
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • in print
    • A. Wang, A. Essner, V.K. Polineni, C. Stark, J.H. Dumbleton, Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements, Tribology International, 1998 (in print).
    • (1998) Tribology International
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 18
    • 0001093632 scopus 로고
    • Friction and molecular structure: The behavior of some thermoplastics
    • C.M. Pooley, D. Tabor, Friction and molecular structure: the behavior of some thermoplastics, Proc. R. Soc. London A 329 (1972) 251-258.
    • (1972) Proc. R. Soc. London A , vol.329 , pp. 251-258
    • Pooley, C.M.1    Tabor, D.2
  • 19
    • 36849155571 scopus 로고
    • Combined rotating and linear motion effects on the wear of polymers
    • B.J. Briscoe, T.A. Stolarski, Combined rotating and linear motion effects on the wear of polymers, Nature (London) 281 (1979) 206-208.
    • (1979) Nature (London) , vol.281 , pp. 206-208
    • Briscoe, B.J.1    Stolarski, T.A.2
  • 20
    • 0021805501 scopus 로고
    • Transfer wear of polymers during combined linear motion and load axis spin
    • B.J. Briscoe, T.A. Stolarski, Transfer wear of polymers during combined linear motion and load axis spin, Wear 104 (1985) 121-137.
    • (1985) Wear , vol.104 , pp. 121-137
    • Briscoe, B.J.1    Stolarski, T.A.2
  • 21
    • 0002665192 scopus 로고
    • A novel technique to measure the cross-link density of irradiated UHMWPE
    • Orthopaedic Research Society, Section 2, The Orthopaedic Research Society, Chicago, IL
    • O.K. Muratoglu, J.L. Cook, M. Jasty, W.H. Harris, A novel technique to measure the cross-link density of irradiated UHMWPE, Transactions of the 44th Annual Meeting, Orthopaedic Research Society, Vol. 23, Section 2, The Orthopaedic Research Society, Chicago, IL, 1988, p. 782.
    • (1988) Transactions of the 44th Annual Meeting , vol.23 , pp. 782
    • Muratoglu, O.K.1    Cook, J.L.2    Jasty, M.3    Harris, W.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.