메뉴 건너뛰기




Volumn 218, Issue 1, 2004, Pages 51-62

A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses

Author keywords

Total joint replacement; Ultra high molecular weight polyethylene (UHMWPE); Wear debris; Wear test machine

Indexed keywords

COMPUTER SIMULATION; FRICTION; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); PERSONAL COMPUTERS; RESERVOIRS (WATER); ROLLING; TRIBOLOGY; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 2142716777     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/095441104322807758     Document Type: Conference Paper
Times cited : (16)

References (31)
  • 1
    • 1242342604 scopus 로고    scopus 로고
    • Hospital In-Patient Enquiry (HIPE) and National Perinatal Reporting Scheme (NPRS) Unit, The Economic and Social Research Institute (Department of Health and Children, Dublin, Ireland)
    • Hospital In-Patient Enquiry (HIPE) and National Perinatal Reporting Scheme (NPRS) Unit, The Economic and Social Research Institute (Department of Health and Children, Dublin, Ireland).
  • 3
    • 0028501856 scopus 로고
    • Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses
    • Schmalzried, T. P., Jasty, M., Rosenberg, A. and Harris, W. Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. J. Appl. Biomater., 1994, 5, 185-190.
    • (1994) J. Appl. Biomater. , vol.5 , pp. 185-190
    • Schmalzried, T.P.1    Jasty, M.2    Rosenberg, A.3    Harris, W.4
  • 4
    • 0028587744 scopus 로고
    • Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty
    • Bosco, J., Benjamin, J. and Wallace, D. Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty. Clin. Orthop. Related Res., 1994, 309, 11-19.
    • (1994) Clin. Orthop. Related Res. , vol.309 , pp. 11-19
    • Bosco, J.1    Benjamin, J.2    Wallace, D.3
  • 5
    • 0028349883 scopus 로고
    • Size and shape of biomaterial wear debris
    • Savvio, J. A., Overcamp, L. M. and Black, J. Size and shape of biomaterial wear debris. Clin. Mater., 1994, 15, 101-147.
    • (1994) Clin. Mater. , vol.15 , pp. 101-147
    • Savvio, J.A.1    Overcamp, L.M.2    Black, J.3
  • 9
    • 0042063879 scopus 로고    scopus 로고
    • In vitro lateral versus medial wear of a knee prosthesis
    • Laurent, M. P., Johnson, I. S., Yao, J. Q., Blanchard, C. R. and Crowninshield, R. D. In vitro lateral versus medial wear of a knee prosthesis. Wear, 2003, 255(7-12), 1101-1106.
    • (2003) Wear , vol.255 , Issue.7-12 , pp. 1101-1106
    • Laurent, M.P.1    Johnson, I.S.2    Yao, J.Q.3    Blanchard, C.R.4    Crowninshield, R.D.5
  • 10
    • 0041562682 scopus 로고    scopus 로고
    • Comparison of wear of mobile and fixed bearing knees tested in a knee simulator
    • Johnson, T. S., Laurent, M. P., Yao, J. Q. and Blanchard, C. R. Comparison of wear of mobile and fixed bearing knees tested in a knee simulator. Wear, 2003, 255(7-12), 1107-1112.
    • (2003) Wear , vol.255 , Issue.7-12 , pp. 1107-1112
    • Johnson, T.S.1    Laurent, M.P.2    Yao, J.Q.3    Blanchard, C.R.4
  • 11
    • 0038546396 scopus 로고    scopus 로고
    • Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene
    • Mazzucco, D. and Spector, M. Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene. Wear, 2003, 254(5-6), 514-522.
    • (2003) Wear , vol.254 , Issue.5-6 , pp. 514-522
    • Mazzucco, D.1    Spector, M.2
  • 12
  • 13
    • 0033490061 scopus 로고    scopus 로고
    • A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement
    • Wang, A., Essner, A., Stark, C. and Dumbleton, J. H. A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement. Wear, 1999, 225-229(2), 701-707.
    • (1999) Wear , vol.225-229 , Issue.2 , pp. 701-707
    • Wang, A.1    Essner, A.2    Stark, C.3    Dumbleton, J.H.4
  • 15
    • 0019596289 scopus 로고
    • Simulation of the knee joint using a computer controlled system
    • Treharne, R. W., Young, R. W. and Young, S. R. Simulation of the knee joint using a computer controlled system. Engng Medicine, 1981, 10(3), 137-142.
    • (1981) Engng Medicine , vol.10 , Issue.3 , pp. 137-142
    • Treharne, R.W.1    Young, R.W.2    Young, S.R.3
  • 16
    • 0020970905 scopus 로고
    • On the pressure dependence of the wear of ultrahigh molecular weight polyethylene
    • Rose, R. M., Goldfarb, H. V., Ellis, E. and Crugnola, A. M. On the pressure dependence of the wear of ultrahigh molecular weight polyethylene. Wear, 1983, 92, 99-111.
    • (1983) Wear , vol.92 , pp. 99-111
    • Rose, R.M.1    Goldfarb, H.V.2    Ellis, E.3    Crugnola, A.M.4
  • 17
    • 0022188512 scopus 로고
    • Influence of counterface topography on the wear of ultra high molecular weight polyethylene under wet or dry conditions
    • American Chemical Society
    • Dowson, D., El-Hady Diab, M. M., Gillis, B. J. and Atkinson, J. R. Influence of counterface topography on the wear of ultra high molecular weight polyethylene under wet or dry conditions. In Wear and its Control, Vol. 12, 1985, pp. 171-187 (American Chemical Society).
    • (1985) Wear and Its Control , vol.12 , pp. 171-187
    • Dowson, D.1    El-Hady Diab, M.M.2    Gillis, B.J.3    Atkinson, J.R.4
  • 18
    • 0023425006 scopus 로고
    • The role of counterface imperfections in the wear of polyethylene
    • Dowson, D., Taheri, S. and Wallbridge, N. C. The role of counterface imperfections in the wear of polyethylene. Wear, 1987, 119, 277-283.
    • (1987) Wear , vol.119 , pp. 277-283
    • Dowson, D.1    Taheri, S.2    Wallbridge, N.C.3
  • 19
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • Wang, A., Stark, C. and Dumbleton, J. H. Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210(H3), 141-155.
    • (1996) Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine , vol.210 , Issue.H3 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 21
    • 0035332921 scopus 로고    scopus 로고
    • A three-axis knee wear simulator with ball-on-flat contact
    • Saikko, V., Ahlroos, T. and Calonius, O. A three-axis knee wear simulator with ball-on-flat contact. Wear, 2001, 249, 310-315.
    • (2001) Wear , vol.249 , pp. 310-315
    • Saikko, V.1    Ahlroos, T.2    Calonius, O.3
  • 22
    • 0036699419 scopus 로고    scopus 로고
    • Simulation of wear rates and mechanisms in total knee prostheses by ball-on-flat contact in a five-station, three-axis test rig
    • Saikko, V. and Calonius, O. Simulation of wear rates and mechanisms in total knee prostheses by ball-on-flat contact in a five-station, three-axis test rig, Wear, 2002, 253, 424-429.
    • (2002) Wear , vol.253 , pp. 424-429
    • Saikko, V.1    Calonius, O.2
  • 23
    • 0026350108 scopus 로고
    • The dominance of cyclic sliding in producing wear in total knee replacements
    • Blunn, G. W., Walker, P. S., Joshi, A. and Hardinge, K. The dominance of cyclic sliding in producing wear in total knee replacements. Clin. Orthop. Related Res., 1991, 273, 253-260.
    • (1991) Clin. Orthop. Related Res. , vol.273 , pp. 253-260
    • Blunn, G.W.1    Walker, P.S.2    Joshi, A.3    Hardinge, K.4
  • 25
    • 0030248625 scopus 로고    scopus 로고
    • Wear testing of materials and surfaces for total knee replacements
    • Walker, P. S., Blunn, G. W. and Lilley, P. A. Wear testing of materials and surfaces for total knee replacements. J. Biomed. Mater. Res., 1996, 33, 159-175.
    • (1996) J. Biomed. Mater. Res. , vol.33 , pp. 159-175
    • Walker, P.S.1    Blunn, G.W.2    Lilley, P.A.3
  • 26
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • Wang, A., Essner, A., Polineni, V. K., Stark, C. and Dumbleton, J. H. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribology Int., 1998, 31(1-3), 17-33.
    • (1998) Tribology Int. , vol.31 , Issue.1-3 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 27
    • 0020100045 scopus 로고
    • Exploratory investigations of the structure dependence of the wear resistance of polyethylene
    • Rose, R. M., Cimino, W. R., Ellis, E. and Crugnola, A. N. Exploratory investigations of the structure dependence of the wear resistance of polyethylene. Wear, 1982, 77, 89-104.
    • (1982) Wear , vol.77 , pp. 89-104
    • Rose, R.M.1    Cimino, W.R.2    Ellis, E.3    Crugnola, A.N.4
  • 28
    • 0031259388 scopus 로고    scopus 로고
    • The influence of stress conditions on the wear of UHMWPE for total joint replacements
    • Barbour, P. S. M., Barton, D. C. and Fisher, J. The influence of stress conditions on the wear of UHMWPE for total joint replacements. J. Mater. Sci.: Mater. Medicine, 1997, 8, 603-611.
    • (1997) J. Mater. Sci.: Mater. Medicine , vol.8 , pp. 603-611
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 29
    • 0031924955 scopus 로고    scopus 로고
    • Effect of oxidation on delamination of ultra high molecular weight polyethylene tibial components
    • Bell, C. J., Walker, P. S., Abeysundera, M. R., Simmons, J. M. H., King, P. M. and Gordon, G. W. Effect of oxidation on delamination of ultra high molecular weight polyethylene tibial components. J. Arthroplasty, 1998, 13(3), 280-290.
    • (1998) J. Arthroplasty , vol.13 , Issue.3 , pp. 280-290
    • Bell, C.J.1    Walker, P.S.2    Abeysundera, M.R.3    Simmons, J.M.H.4    King, P.M.5    Gordon, G.W.6
  • 30
    • 0019364909 scopus 로고
    • The deformation and wear of plastic components in artificial knee joints - An experimental study
    • Walker, P. S., Ben-Dov, M., Askew, M. J. and Pugh, J. The deformation and wear of plastic components in artificial knee joints - an experimental study. Engng in Medicine, 1981, 10(1), 33-38.
    • (1981) Engng in Medicine , vol.10 , Issue.1 , pp. 33-38
    • Walker, P.S.1    Ben-Dov, M.2    Askew, M.J.3    Pugh, J.4
  • 31
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements
    • Wang, A., Sun, D. C., Stark, C. and Dumbleton, J. H. Wear mechanisms of UHMWPE in total joint replacements. Wear, 1995, 181-183, 241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.