1
-
-
0032774199
-
The Insall-Burstein total knee replacement in osteoarthritis: A 10-year minimum follow-up
-
Aglletti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty. 1999;14:560-5.
-
(1999)
J Arthroplasty
, vol.14
, pp. 560-565
-
-
Aglletti, P.1
Buzzi, R.2
De Felice, R.3
Giron, F.4
-
2
-
-
0027208262
-
Extensive osteolysis around an aseptic, stable, uncemented total knee replacement
-
Berry DJ, Wold LE, Rand JA. Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop. 1993;293:204-7.
-
(1993)
Clin Orthop
, vol.293
, pp. 204-207
-
-
Berry, D.J.1
Wold, L.E.2
Rand, J.A.3
-
4
-
-
0028272509
-
Failure of a polyethylene total knee component presenting as a thigh mass. Report of a rare complication of total knee arthroplasty
-
Chavda DV, Garvin KL. Failure of a polyethylene total knee component presenting as a thigh mass. Report of a rare complication of total knee arthroplasty. Clin Orthop. 1994;303:211-6.
-
(1994)
Clin Orthop
, vol.303
, pp. 211-216
-
-
Chavda, D.V.1
Garvin, K.L.2
-
5
-
-
0034036811
-
Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components
-
Engh GA, Koralewicz LM, Pereles TR. Clinical results of modular polyethylene insert exchange with retention of total knee arthroplasty components. J Bone Joint Surg Am. 2000;82:516-23.
-
(2000)
J Bone Joint Surg Am
, vol.82
, pp. 516-523
-
-
Engh, G.A.1
Koralewicz, L.M.2
Pereles, T.R.3
-
6
-
-
0032913473
-
Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty
-
Huang CH, Yang CY, Cheng CK. Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty. J Arthroplasty. 1999;14:375-9.
-
(1999)
J Arthroplasty
, vol.14
, pp. 375-379
-
-
Huang, C.H.1
Yang, C.Y.2
Cheng, C.K.3
-
7
-
-
0028923420
-
Osteolysis around cementless porous-coated anatomic knee prostheses
-
Kim YH, Oh JH, Oh SH. Osteolysis around cementless porous-coated anatomic knee prostheses. J Bone Joint Surg Br. 1995;77:236-41.
-
(1995)
J Bone Joint Surg Br
, vol.77
, pp. 236-241
-
-
Kim, Y.H.1
Oh, J.H.2
Oh, S.H.3
-
9
-
-
0028785801
-
Catastrophic osteolysis in total knee replacement. A report of 17 cases
-
Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C. Catastrophic osteolysis in total knee replacement. A report of 17 cases. Clin Orthop. 1995;321:98-105.
-
(1995)
Clin Orthop
, vol.321
, pp. 98-105
-
-
Robinson, E.J.1
Mulliken, B.D.2
Bourne, R.B.3
Rorabeck, C.H.4
Alvarez, C.5
-
10
-
-
0035113426
-
Failed cementless total knee arthroplasty presenting as osteolysis of the fibular head
-
Rodriguez RJ, Barrack RL. Failed cementless total knee arthroplasty presenting as osteolysis of the fibular head. J Arthroplasty. 2001;16:239-42.
-
(2001)
J Arthroplasty
, vol.16
, pp. 239-242
-
-
Rodriguez, R.J.1
Barrack, R.L.2
-
11
-
-
0031457130
-
Tibial insert undersurface as a contributing source of polyethylene wear debris
-
Wasielewski RC, Parks N, Williams I, Surprenant H, Collier JP, Engh G. Tibial insert undersurface as a contributing source of polyethylene wear debris. Clin Orthop. 1997;345:53-9.
-
(1997)
Clin Orthop
, vol.345
, pp. 53-59
-
-
Wasielewski, R.C.1
Parks, N.2
Williams, I.3
Surprenant, H.4
Collier, J.P.5
Engh, G.6
-
12
-
-
0031941164
-
Results of revision total knee arthroplasty in the face of significant bone deficiency
-
Rorabeck CH, Smith PN. Results of revision total knee arthroplasty in the face of significant bone deficiency. Orthop Clin North Am. 1998;29:361-71.
-
(1998)
Orthop Clin North Am
, vol.29
, pp. 361-371
-
-
Rorabeck, C.H.1
Smith, P.N.2
-
13
-
-
0031981874
-
Postirradiation aging affects stress and strain in polyethylene components
-
Kurtz SM, Bartel DL, Rimnac CM. Postirradiation aging affects stress and strain in polyethylene components. Clin Orthop. 1998;350:209-20.
-
(1998)
Clin Orthop
, vol.350
, pp. 209-220
-
-
Kurtz, S.M.1
Bartel, D.L.2
Rimnac, C.M.3
-
14
-
-
0033922918
-
Effect of resin type and manufacturing method on wear of polyethylene tibial components
-
Won CH, Rohatgi S, Kraay MJ, Goldberg VM, Rimnac CM. Effect of resin type and manufacturing method on wear of polyethylene tibial components. Clin Orthop. 2000;376:161-71.
-
(2000)
Clin Orthop
, vol.376
, pp. 161-171
-
-
Won, C.H.1
Rohatgi, S.2
Kraay, M.J.3
Goldberg, V.M.4
Rimnac, C.M.5
-
15
-
-
0033751999
-
Ten- to 12-year followup of the Insall-Burstein I total knee prosthesis
-
Thadani PJ, Vince KG, Ortaaslan SG, Blackburn DC, Cudiamat CV. Ten- to 12-year followup of the Insall-Burstein I total knee prosthesis. Clin Orthop. 2000;380:17-29.
-
(2000)
Clin Orthop
, vol.380
, pp. 17-29
-
-
Thadani, P.J.1
Vince, K.G.2
Ortaaslan, S.G.3
Blackburn, D.C.4
Cudiamat, C.V.5
-
16
-
-
0023007566
-
The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
-
Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg Am. 1986;68:1041-51.
-
(1986)
J Bone Joint Surg Am
, vol.68
, pp. 1041-1051
-
-
Bartel, D.L.1
Bicknell, V.L.2
Wright, T.M.3
-
17
-
-
0029052864
-
Stresses in polyethylene components of contemporary total knee replacements
-
Bartel DL, Rawlinson JJ, Burstein AH, Ranawat CS, Flynn WF Jr. Stresses in polyethylene components of contemporary total knee replacements. Clin Orthop. 1995;317:76-82.
-
(1995)
Clin Orthop
, vol.317
, pp. 76-82
-
-
Bartel, D.L.1
Rawlinson, J.J.2
Burstein, A.H.3
Ranawat, C.S.4
Flynn W.F., Jr.5
-
18
-
-
0032972217
-
Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty
-
Hirakawa K, Bauer TW, Yamaguchi M, Stulberg BN, Wilde AH. Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty. J Arthroplasty. 1999;14:165-71.
-
(1999)
J Arthroplasty
, vol.14
, pp. 165-171
-
-
Hirakawa, K.1
Bauer, T.W.2
Yamaguchi, M.3
Stulberg, B.N.4
Wilde, A.H.5
-
19
-
-
0026527293
-
Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
-
Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br. 1992;74:9-17.
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 9-17
-
-
Engh, G.A.1
Dwyer, K.A.2
Hanes, C.K.3
-
20
-
-
0027752702
-
Noncemented, porous ingrowth knee prosthesis: The 3- to 8-year results
-
Cameron HU, Jung YB. Noncemented, porous ingrowth knee prosthesis: the 3- to 8-year results. Can J Surg. 1993;36:560-4.
-
(1993)
Can J Surg
, vol.36
, pp. 560-564
-
-
Cameron, H.U.1
Jung, Y.B.2
-
21
-
-
0033752667
-
Rotational malalignment of the femoral component in total knee arthroplasty
-
Fehring TK. Rotational malalignment of the femoral component in total knee arthroplasty. Clin Orthop. 2000;380:72-9.
-
(2000)
Clin Orthop
, vol.380
, pp. 72-79
-
-
Fehring, T.K.1
-
22
-
-
0032438463
-
The impact of sterilization method on wear in knee arthroplasty
-
Williams IR, Mayor MB, Collier JP. The impact of sterilization method on wear in knee arthroplasty. Clin Orthop. 1998;356:170-80.
-
(1998)
Clin Orthop
, vol.356
, pp. 170-180
-
-
Williams, I.R.1
Mayor, M.B.2
Collier, J.P.3
-
23
-
-
0019543365
-
Effect of radiation sterilization and aging on ultrahigh molecular weight polyethylene
-
Roe RJ, Grood ES, Shastri R, Gosselin CA, Noyes FR. Effect of radiation sterilization and aging on ultrahigh molecular weight polyethylene. J Biomed Mater Res. 1981;15:209-30.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 209-230
-
-
Roe, R.J.1
Grood, E.S.2
Shastri, R.3
Gosselin, C.A.4
Noyes, F.R.5
-
26
-
-
0029955320
-
Impact of gamma sterilization on clinical performance of polyethylene in the knee
-
Collier JP, Sperling DK, Currier JH, Sutula LC, Saum KA, Mayor MB. Impact of gamma sterilization on clinical performance of polyethylene in the knee. J Arthroplasty. 1996;11:377-89.
-
(1996)
J Arthroplasty
, vol.11
, pp. 377-389
-
-
Collier, J.P.1
Sperling, D.K.2
Currier, J.H.3
Sutula, L.C.4
Saum, K.A.5
Mayor, M.B.6
-
27
-
-
0035103906
-
Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris
-
Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am. 2001;83:390-7.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 390-397
-
-
Puloski, S.K.1
McCalden, R.W.2
MacDonald, S.J.3
Rorabeck, C.H.4
Bourne, R.B.5
-
28
-
-
0035100880
-
Loosening and osteolysis with the press-fit cordylar posterior-cruciate-substituting total knee replacement
-
Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP. Loosening and osteolysis with the press-fit cordylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg Am. 2001;83:398-403.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 398-403
-
-
Mikulak, S.A.1
Mahoney, O.M.2
Dela Rosa, M.A.3
Schmalzried, T.P.4
-
30
-
-
0028838566
-
Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement
-
Ritter MA, Worland R, Saliski J, Helphenstine JV, Edmondson KL, Keating EM, Faris PM, Meding JB. Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement. Clin Orthop. 1995;321:79-85.
-
(1995)
Clin Orthop
, vol.321
, pp. 79-85
-
-
Ritter, M.A.1
Worland, R.2
Saliski, J.3
Helphenstine, J.V.4
Edmondson, K.L.5
Keating, E.M.6
Faris, P.M.7
Meding, J.B.8
-
32
-
-
0001093632
-
Friction and molecular structure: The behaviour of some thermoplastics
-
Pooley CM, Tabor D. Friction and molecular structure: the behaviour of some thermoplastics. Proc R Soc Lond A. 1972;329:251-74.
-
(1972)
Proc R Soc Lond A
, vol.329
, pp. 251-274
-
-
Pooley, C.M.1
Tabor, D.2
-
33
-
-
0030331545
-
The importance of multidirectional motion on the wear of polyethylene
-
Bragdon CR, O'Connor DO, Lowenstein JD, Jasty M, Syniuta WD. The importance of multidirectional motion on the wear of polyethylene. Proc Inst Mech Engl [H]. 1996;210:157-65.
-
(1996)
Proc Inst Mech Engl [H]
, vol.210
, pp. 157-165
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Lowenstein, J.D.3
Jasty, M.4
Syniuta, W.D.5
-
34
-
-
0029255360
-
Wear mechanisms of UHMWPE in total joint replacements
-
Wang A, Sun DC, Stark C, Dumbleton JH. Wear mechanisms of UHMWPE in total joint replacements. Wear. 1995;181-183:241-9.
-
(1995)
Wear
, vol.181-183
, pp. 241-249
-
-
Wang, A.1
Sun, D.C.2
Stark, C.3
Dumbleton, J.H.4
-
35
-
-
0031894928
-
A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty
-
Wimmer MA, Andriacchi TP, Natarajan RN, Loos J, Karlhuber M, Petermann J, Schneider E, Rosenberg AG. A striated pattern of wear in ultrahigh-molecular-weight polyethylene components of Miller-Galante total knee arthroplasty. J Arthroplasty. 1998;13:8-16.
-
(1998)
J Arthroplasty
, vol.13
, pp. 8-16
-
-
Wimmer, M.A.1
Andriacchi, T.P.2
Natarajan, R.N.3
Loos, J.4
Karlhuber, M.5
Petermann, J.6
Schneider, E.7
Rosenberg, A.G.8
-
36
-
-
0027972449
-
Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
-
Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop. 1994; 299:31-43.
-
(1994)
Clin Orthop
, vol.299
, pp. 31-43
-
-
Wasielewski, R.C.1
Galante, J.O.2
Leighty, R.M.3
Natarajan, R.N.4
Rosenberg, A.G.5
-
37
-
-
0033980019
-
Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements
-
Shanbhag AS, Bailey HO, Hwang DS, Cha CW, Eror NG, Rubash HE. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. J Biomed Mater Res. 2000; 53:100-10.
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 100-110
-
-
Shanbhag, A.S.1
Bailey, H.O.2
Hwang, D.S.3
Cha, C.W.4
Eror, N.G.5
Rubash, H.E.6
-
38
-
-
0026569950
-
Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement
-
Nolan JF, Bucknill TM. Aggressive granulomatosis from polyethylene failure in an uncemented knee replacement. J Bone Joint Surg Br. 1992;74:23-4.
-
(1992)
J Bone Joint Surg Br
, vol.74
, pp. 23-24
-
-
Nolan, J.F.1
Bucknill, T.M.2
-
39
-
-
0024788871
-
The patellofemoral joint in total knee prostheses. Design considerations
-
Freeman MA, Samuelson KM, Elias SG, Mariorenzi U, Gokcay EI, Tuke M. The patellofemoral joint in total knee prostheses. Design considerations. J Arthroplasty. 1989;4 Suppl:S69-74.
-
(1989)
J Arthroplasty
, vol.4
, Issue.SUPPL.
-
-
Freeman, M.A.1
Samuelson, K.M.2
Elias, S.G.3
Mariorenzi, U.4
Gokcay, E.I.5
Tuke, M.6
-
40
-
-
0032201263
-
Modular tibial insert micromotion. A concern with contemporary knee implants
-
The Coventry Award
-
Parks NL, Engh GA, Topoleski LD, Emperado J. The Coventry Award. Modular tibial insert micromotion. A concern with contemporary knee implants. Clin Orthop. 1998;356:10-5.
-
(1998)
Clin Orthop
, vol.356
, pp. 10-15
-
-
Parks, N.L.1
Engh, G.A.2
Topoleski, L.D.3
Emperado, J.4
-
42
-
-
0026336917
-
All-polyethylene patellar components are not the answer
-
Collier JP, McNamara JL, Surprenant VA, Jensen RE, Surprenant HP. All-polyethylene patellar components are not the answer. Clin Orthop. 1991; 273:198-203.
-
(1991)
Clin Orthop
, vol.273
, pp. 198-203
-
-
Collier, J.P.1
McNamara, J.L.2
Surprenant, V.A.3
Jensen, R.E.4
Surprenant, H.P.5
-
43
-
-
0029013290
-
Patellofemoral contact pressures exceed the compressive yield strength of UHMWPE in total knee arthroplasties
-
Takeuchi T, Lathi VK, Khan AM, Hayes WC. Patellofemoral contact pressures exceed the compressive yield strength of UHMWPE in total knee arthroplasties. J Arthroplasty. 1995;10:363-8.
-
(1995)
J Arthroplasty
, vol.10
, pp. 363-368
-
-
Takeuchi, T.1
Lathi, V.K.2
Khan, A.M.3
Hayes, W.C.4
-
44
-
-
0028301504
-
The patellofemoral joint - Its function and influence in patellar replacement design
-
Pappas MJ, Buechel FF. The patellofemoral joint - its function and influence in patellar replacement design. J Orthop Rheumatol. 1994;7:75-80.
-
(1994)
J Orthop Rheumatol
, vol.7
, pp. 75-80
-
-
Pappas, M.J.1
Buechel, F.F.2
-
45
-
-
0028941335
-
Tricon hybrid total knee arthroplasty: A review of 81 knees followed for 2 to 4 years
-
Briggs JR, Augenstein JS. Tricon hybrid total knee arthroplasty: a review of 81 knees followed for 2 to 4 years. Orthopedics. 1995;18:341-6.
-
(1995)
Orthopedics
, vol.18
, pp. 341-346
-
-
Briggs, J.R.1
Augenstein, J.S.2
-
46
-
-
0031029828
-
Medialization of the patella in total knee arthroplasty
-
Lewonowski K, Dorr LD, McPherson EJ, Huber G, Wan Z. Medialization of the patella in total knee arthroplasty. J Arthroplasty. 1997;12:161-7.
-
(1997)
J Arthroplasty
, vol.12
, pp. 161-167
-
-
Lewonowski, K.1
Dorr, L.D.2
McPherson, E.J.3
Huber, G.4
Wan, Z.5
-
47
-
-
0025054164
-
The effect of femoral component position on patellar tracking after total knee arthroplasty
-
Rhoads DD, Noble PC, Reuben JD, Mahoney OM, Tullos HS. The effect of femoral component position on patellar tracking after total knee arthroplasty. Clin Orthop. 1990;260:43-51.
-
(1990)
Clin Orthop
, vol.260
, pp. 43-51
-
-
Rhoads, D.D.1
Noble, P.C.2
Reuben, J.D.3
Mahoney, O.M.4
Tullos, H.S.5
-
48
-
-
0031030203
-
Effect of femoral component rotation and patellar design on patellar forces
-
Singerman R, Pagan HD, Peyser AB, Goldberg VM. Effect of femoral component rotation and patellar design on patellar forces. Clin Orthop. 1997;334:345-53.
-
(1997)
Clin Orthop
, vol.334
, pp. 345-353
-
-
Singerman, R.1
Pagan, H.D.2
Peyser, A.B.3
Goldberg, V.M.4
-
49
-
-
0038776106
-
Biomechanics of the patella in total knee replacement
-
Walker PS. Biomechanics of the patella in total knee replacement. Knee Surg Sports Traumatol Arthrosc. 2001;9(Suppl 1):S3-7.
-
(2001)
Knee Surg Sports Traumatol Arthrosc
, vol.9
, Issue.SUPPL. 1
-
-
Walker, P.S.1
-
50
-
-
0035117295
-
A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award
-
Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 2001;16:149-60.
-
(2001)
J Arthroplasty
, vol.16
, pp. 149-160
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harris, W.H.5
-
51
-
-
0033178826
-
Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE)
-
Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH, Gul R, McGarry F. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials. 1999;20:1463-70.
-
(1999)
Biomaterials
, vol.20
, pp. 1463-1470
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
O'Connor, D.O.3
Jasty, M.4
Harris, W.H.5
Gul, R.6
McGarry, F.7
-
52
-
-
0032927112
-
Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
-
McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999;17:157-67.
-
(1999)
J Orthop Res
, vol.17
, pp. 157-167
-
-
McKellop, H.1
Shen, F.W.2
Lu, B.3
Campbell, P.4
Salovey, R.5
-
53
-
-
0038776105
-
Articular surface morphology in explanted highly crosslinked UHMWPE acetabular liners
-
Muratoglu OK, Bragdon CR, Larson S, Perinchief RS, Harris WH. Articular surface morphology in explanted highly crosslinked UHMWPE acetabular liners. Trans Orthop Res Soc. 2002;27:1029.
-
(2002)
Trans Orthop Res Soc
, vol.27
, pp. 1029
-
-
Muratoglu, O.K.1
Bragdon, C.R.2
Larson, S.3
Perinchief, R.S.4
Harris, W.H.5
-
54
-
-
0011407067
-
Knee wear testing of a radiation crosslinked and remelted UHMWPE
-
Hastings R, Huston D, Reber E, DiMaio W. Knee wear testing of a radiation crosslinked and remelted UHMWPE. Trans Soc Biomat. 1999;25:328.
-
(1999)
Trans Soc Biomat
, vol.25
, pp. 328
-
-
Hastings, R.1
Huston, D.2
Reber, E.3
DiMaio, W.4
-
55
-
-
0038438249
-
A novel method to quantify wear and creep deformation on UHMWPE tibial knee inserts
-
Muratoglu O, Perinchief R, Konrad R, Harris WH. A novel method to quantify wear and creep deformation on UHMWPE tibial knee inserts. Trans Orthop Res Soc. 2001;26:221.
-
(2001)
Trans Orthop Res Soc
, vol.26
, pp. 221
-
-
Muratoglu, O.1
Perinchief, R.2
Konrad, R.3
Harris, W.H.4
-
56
-
-
0038438249
-
Metrology to quantify wear and creep of polyethylene tibial knee inserts
-
Muratoglu OK, Perinchief RS, Bragdon CR, O'Connor DO, Konrad R, Harris WH. Metrology to quantify wear and creep of polyethylene tibial knee inserts. Trans Orthop Res Soc. 2001;26:221.
-
(2001)
Trans Orthop Res Soc
, vol.26
, pp. 221
-
-
Muratoglu, O.K.1
Perinchief, R.S.2
Bragdon, C.R.3
O'Connor, D.O.4
Konrad, R.5
Harris, W.H.6
-
58
-
-
0000792084
-
Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by kip and knee joint simulators
-
Wang A, Polineni VK, Essner A, Sun DC, Stark C, Dumbleton JH. Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by kip and knee joint simulators. Trans Soc Biomater. 1997;23:394.
-
(1997)
Trans Soc Biomater
, vol.23
, pp. 394
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Sun, D.C.4
Stark, C.5
Dumbleton, J.H.6
-
59
-
-
0038776104
-
Development of an in vitro delamination model in a knee simulator with physiologic load and motion
-
Deluzio KJ, O'Connor DO, Bragdon CR, Muratoglu OK, O'Flynn H, Rubash H, Jasty M, Wyss UP, Harris WH. Development of an in vitro delamination model in a knee simulator with physiologic load and motion. Trans Orthop Res Soc. 2000;25:490.
-
(2000)
Trans Orthop Res Soc
, vol.25
, pp. 490
-
-
Deluzio, K.J.1
O'Connor, D.O.2
Bragdon, C.R.3
Muratoglu, O.K.4
O'Flynn, H.5
Rubash, H.6
Jasty, M.7
Wyss, U.P.8
Harris, W.H.9
-
60
-
-
0031626848
-
In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses
-
Currier JH, Duda JL, Sperling DK, Collier JP, Currier BH, Kennedy FE. In vitro simulation of contact fatigue damage found in ultra-high molecular weight polyethylene components of knee prostheses. Proc Inst Mech Eng [H]. 1998; 212:293-302.
-
(1998)
Proc Inst Mech Eng [H]
, vol.212
, pp. 293-302
-
-
Currier, J.H.1
Duda, J.L.2
Sperling, D.K.3
Collier, J.P.4
Currier, B.H.5
Kennedy, F.E.6
-
61
-
-
0000353222
-
Accelerated oxidative aging testing of UHMWPE
-
Sanford WM, Saum KA. Accelerated oxidative aging testing of UHMWPE. Trans Orthop Res Soc. 1995;20:119.
-
(1995)
Trans Orthop Res Soc
, vol.20
, pp. 119
-
-
Sanford, W.M.1
Saum, K.A.2
-
62
-
-
0000082414
-
Development of an accelerated aging method for evaluation of long-term irradiation effects on UHMWPE implants
-
Sun D, Stark C, Dumbleton J. Development of an accelerated aging method for evaluation of long-term irradiation effects on UHMWPE implants. Polymer Reprints. 1994;35:969-70.
-
(1994)
Polymer Reprints
, vol.35
, pp. 969-970
-
-
Sun, D.1
Stark, C.2
Dumbleton, J.3
-
63
-
-
0034059304
-
Methodology for long-term wear testing of total knee replacements
-
Walker PS, Blunn GW, Perry JP, Bell CJ, Sathasivam S, Andriacchi TP, Paul JP, Haider H, Campbell PA. Methodology for long-term wear testing of total knee replacements. Clin Orthop. 2000;372:290-301.
-
(2000)
Clin Orthop
, vol.372
, pp. 290-301
-
-
Walker, P.S.1
Blunn, G.W.2
Perry, J.P.3
Bell, C.J.4
Sathasivam, S.5
Andriacchi, T.P.6
Paul, J.P.7
Haider, H.8
Campbell, P.A.9
|