-
1
-
-
0036325041
-
Perfusion quantification using Gaussian process deconvolution
-
Andersen I K, Szymkowiak A, Rasmussen C E, Hanson L G, Marstrand J R, Larsson H B W and Hansen L K 2002 Perfusion quantification using Gaussian process deconvolution Magn. Reson. Med. 48 351-61
-
(2002)
Magn. Reson. Med.
, vol.48
, pp. 351-361
-
-
Andersen, I.K.1
Szymkowiak, A.2
Rasmussen, C.E.3
Hanson, L.G.4
Marstrand, J.R.5
Larsson, H.B.W.6
Hansen, L.K.7
-
4
-
-
0042919443
-
Perfusion thresholds in acute stroke thrombolysis
-
Butcher K, Parsons M, Baird T, Barber A, Donnan G, Desmond P, Tress B and Davis S 2003 Perfusion thresholds in acute stroke thrombolysis Stroke 34 2159-64
-
(2003)
Stroke
, vol.34
, pp. 2159-2164
-
-
Butcher, K.1
Parsons, M.2
Baird, T.3
Barber, A.4
Donnan, G.5
Desmond, P.6
Tress, B.7
Davis, S.8
-
5
-
-
0033812331
-
Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
-
Calamante F, Gadian D G and Connelly A 2000 Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition Magn. Reson. Med. 44 466-73
-
(2000)
Magn. Reson. Med.
, vol.44
, pp. 466-473
-
-
Calamante, F.1
Gadian, D.G.2
Connelly, A.3
-
6
-
-
0036221582
-
Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke; assumptions, limitations, and potential implications for clinical use
-
Calamante F, Gadian D G and Connelly A 2002 Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke; assumptions, limitations, and potential implications for clinical use Stroke 33 1146-51
-
(2002)
Stroke
, vol.33
, pp. 1146-1151
-
-
Calamante, F.1
Gadian, D.G.2
Connelly, A.3
-
7
-
-
4344624965
-
Quantification of bolus-tracking MRI: Improved characterization of the residue function using Tikhonov regularization
-
Calamante F, Gadian D G and Connelly A 2003 Quantification of bolus-tracking MRI: improved characterization of the residue function using Tikhonov regularization Proc. Int. Soc. Magn. Reson. Med. (Toronto) p 422
-
(2003)
Proc. Int. Soc. Magn. Reson. Med. (Toronto)
, pp. 422
-
-
Calamante, F.1
Gadian, D.G.2
Connelly, A.3
-
8
-
-
0033496776
-
Measuring cerebral blood flow using magnetic resonance imaging techniques
-
Calamante F, Thomas D L, Pell G S, Wiersma J and Turner R 1999 Measuring cerebral blood flow using magnetic resonance imaging techniques J. Cereb. Blood Flow Metab. 19 701-35
-
(1999)
J. Cereb. Blood Flow Metab.
, vol.19
, pp. 701-735
-
-
Calamante, F.1
Thomas, D.L.2
Pell, G.S.3
Wiersma, J.4
Turner, R.5
-
9
-
-
0036237992
-
Breast cancer: Regional blood flow and blood volume measured with magnetic susceptibility-based MR imaging - Initial results
-
Delille J P, Slanetz P J, Yeh E D, Kopand D B and Garrido L 2002 Breast cancer: regional blood flow and blood volume measured with magnetic susceptibility-based MR imaging - initial results Radiology 223 558-65
-
(2002)
Radiology
, vol.223
, pp. 558-565
-
-
Delille, J.P.1
Slanetz, P.J.2
Yeh, E.D.3
Kopand, D.B.4
Garrido, L.5
-
11
-
-
0000570697
-
Analysis of discrete ill-posed problems by means of the L-curve
-
Hansen P C 1992 Analysis of discrete ill-posed problems by means of the L-curve SIAM Rev. 34 561-80
-
(1992)
SIAM Rev.
, vol.34
, pp. 561-580
-
-
Hansen, P.C.1
-
14
-
-
0032793622
-
Cerebral blood flow measurement by dynamic contrast MRI using singular value decomposition with an adaptive threshold
-
Liu H L, Pu Y, Liu Y, Nickerson L, Andrews T, Fox P T and Gao J H 1999 Cerebral blood flow measurement by dynamic contrast MRI using singular value decomposition with an adaptive threshold Magn. Reson. Med. 42 167-72
-
(1999)
Magn. Reson. Med.
, vol.42
, pp. 167-172
-
-
Liu, H.L.1
Pu, Y.2
Liu, Y.3
Nickerson, L.4
Andrews, T.5
Fox, P.T.6
Gao, J.H.7
-
15
-
-
0035739233
-
Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging
-
Murase K, Shinohara M and Yamazaki Y 2001 Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging Phys. Med. Biol. 46 3147-59
-
(2001)
Phys. Med. Biol.
, vol.46
, pp. 3147-3159
-
-
Murase, K.1
Shinohara, M.2
Yamazaki, Y.3
-
16
-
-
0029909977
-
High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: II. Experimental comparison and preliminary results
-
Ostergaard L, Sorensen A G, Kwong K K, Weiskoff R M, Gyldensted C and Rosen B R 1996a High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: II. Experimental comparison and preliminary results Magn. Reson. Med. 36 726-36
-
(1996)
Magn. Reson. Med.
, vol.36
, pp. 726-736
-
-
Ostergaard, L.1
Sorensen, A.G.2
Kwong, K.K.3
Weiskoff, R.M.4
Gyldensted, C.5
Rosen, B.R.6
-
17
-
-
0029907308
-
High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: I. Mathematical approach and statistical analysis
-
Ostergaard. L, Weisskoff R M, Chesler D A, Gyldensted C and Rosen B R 1996b High resolution measurement of cerebral blood flow using intravascular tracer bolus passages: I. Mathematical approach and statistical analysis MAGN. Reason. Med. 36 715-25
-
(1996)
MAGN. Reason. Med.
, vol.36
, pp. 715-725
-
-
Ostergaard, L.1
Weisskoff, R.M.2
Chesler, D.A.3
Gyldensted, C.4
Rosen, B.R.5
-
18
-
-
0036238404
-
Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imaging
-
Perkiö J, Aronen H J, Kangasmäki A, Liu Y, Karonen J, Savolainen S and Ostergaard L 2002 Evaluation of four postprocessing methods for determination of cerebral blood volume and mean transit time by dynamic susceptibility contrast imaging Magn. Reson. Med. 47 973-81
-
(2002)
Magn. Reson. Med.
, vol.47
, pp. 973-981
-
-
Perkiö, J.1
Aronen, H.J.2
Kangasmäki, A.3
Liu, Y.4
Karonen, J.5
Savolainen, S.6
Ostergaard, L.7
-
19
-
-
0028072844
-
Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
-
Rempp K A, Brix G, Wenz F, Becker C Gückel and Lorenz W J 1994 Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging Radiology 193 637-41
-
(1994)
Radiology
, vol.193
, pp. 637-641
-
-
Rempp, K.A.1
Brix, G.2
Wenz, F.3
Becker, C.4
Gückel, A.5
Lorenz, W.J.6
-
20
-
-
0034026245
-
Whole brain quantitative CBF and CBV measurements using MRI bolus tracking: Comparison of methodologies
-
Smith A M, Grandin C B, Duprez T, Mataigne F and Cosnard G 2000 Whole brain quantitative CBF and CBV measurements using MRI bolus tracking: comparison of methodologies Magn. Reson. Med. 43 559-64
-
(2000)
Magn. Reson. Med.
, vol.43
, pp. 559-564
-
-
Smith, A.M.1
Grandin, C.B.2
Duprez, T.3
Mataigne, F.4
Cosnard, G.5
-
21
-
-
0037225903
-
Signal-to-noise ratio effects in quantitative cerebral perfusion using dynamic susceptibility contrast agents
-
Smith M R, Lu H and Frayne F 2003 Signal-to-noise ratio effects in quantitative cerebral perfusion using dynamic susceptibility contrast agents Magn. Reson. Med. 46 122-8
-
(2003)
Magn. Reson. Med.
, vol.46
, pp. 122-128
-
-
Smith, M.R.1
Lu, H.2
Frayne, F.3
-
24
-
-
4344714967
-
Discretising the convolution product in DSC-MRI based quantification of CBF
-
Sourbron S, Stubbe I, Luypaert R and Osteaux M 2003b Discretising the convolution product in DSC-MRI based quantification of CBF MAGMA 16 134
-
(2003)
MAGMA
, vol.16
, pp. 134
-
-
Sourbron, S.1
Stubbe, I.2
Luypaert, R.3
Osteaux, M.4
-
25
-
-
0032966087
-
Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
-
Vonken E P A, Beekman F J, Bakker C J G and Viergever M A 1999 Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI Magn. Reson. Med. 41 343-50
-
(1999)
Magn. Reson. Med.
, vol.41
, pp. 343-450
-
-
Vonken, E.P.A.1
Beekman, F.J.2
Bakker, C.J.G.3
Viergever, M.A.4
-
26
-
-
0000544453
-
Practical approximate solutions to linear operator equations when the data are noisy
-
Wahba G 1977 Practical approximate solutions to linear operator equations when the data are noisy SIAM J. Numer. Anal. 14 651-67
-
(1977)
SIAM J. Numer. Anal.
, vol.14
, pp. 651-667
-
-
Wahba, G.1
-
27
-
-
0034063886
-
Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques
-
Wirestam R, Andersson L, Ostergaard L, Bolling M, Aunola J P, Lindgren A, Geijer B, Holtås S and Ståhlberg F 2000 Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques Magn. Reson. Med. 43 691-700
-
(2000)
Magn. Reson. Med.
, vol.43
, pp. 691-700
-
-
Wirestam, R.1
Andersson, L.2
Ostergaard, L.3
Bolling, M.4
Aunola, J.P.5
Lindgren, A.6
Geijer, B.7
Holtås, S.8
Ståhlberg, F.9
-
28
-
-
3242709650
-
Improved deconvolution by wavelet-based denoising for assessment of CBF using dynamic susceptibility contrast MRI
-
Wirestam R and Ståhlberg F 2002 Improved deconvolution by wavelet-based denoising for assessment of CBF using dynamic susceptibility contrast MRI MAGMA 15 12-3
-
(2002)
MAGMA
, vol.15
, pp. 12-13
-
-
Wirestam, R.1
Ståhlberg, F.2
-
29
-
-
0037587219
-
Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix
-
Wu O, Ostergaard L, Benner T, Rosen B, Weisskoff R and Sorensen A G 2003 Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix Magn. Reson. Med. 50 164-74
-
(2003)
Magn. Reson. Med.
, vol.50
, pp. 164-174
-
-
Wu, O.1
Ostergaard, L.2
Benner, T.3
Rosen, B.4
Weisskoff, R.5
Sorensen, A.G.6
|