메뉴 건너뛰기




Volumn 42, Issue 1, 1999, Pages 167-172

Cerebral blood flow measurement by dynamic contrast MRI using singular value decomposition with an adaptive threshold

Author keywords

Cerebral blood flow; MRI; Perfusion; Singular value decomposition

Indexed keywords

BLOOD; FLOW MEASUREMENT; HEMODYNAMICS; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; MONTE CARLO METHODS; PIXELS; SIGNAL TO NOISE RATIO;

EID: 0032793622     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199907)42:1<167::AID-MRM22>3.0.CO;2-Q     Document Type: Article
Times cited : (97)

References (13)
  • 3
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chester DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chester, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 4
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results
    • Ostergaard L, Sorensen AG, Kwong KK, Weisskoff RM, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part II: Experimental comparison and preliminary results. Magn Reson Med 1996;36:726-736.
    • (1996) Magn Reson Med , vol.36 , pp. 726-736
    • Ostergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3    Weisskoff, R.M.4    Gyldensted, C.5    Rosen, B.R.6
  • 6
    • 0028061727 scopus 로고
    • A deconvolution method for evaluating indicator-dilution curves
    • Gobbel GT, Fike JR. A deconvolution method for evaluating indicator-dilution curves. Phys Med Biol 1994;39:1833-1854.
    • (1994) Phys Med Biol , vol.39 , pp. 1833-1854
    • Gobbel, G.T.1    Fike, J.R.2
  • 7
    • 0028072844 scopus 로고
    • Quantification of regional blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Gueckel Lorenz WJ. Quantification of regional blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193:637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gueckel Lorenz, W.J.5
  • 8
    • 0023120065 scopus 로고
    • Reliable and efficient deconvolution technique based on total linear least squares for calculating the renal retention function
    • Huffel SV, Vandewalle J, Roo MCD, Willems JL. Reliable and efficient deconvolution technique based on total linear least squares for calculating the renal retention function. Med Biol Eng Comput 1987;25:26-33.
    • (1987) Med Biol Eng Comput , vol.25 , pp. 26-33
    • Huffel, S.V.1    Vandewalle, J.2    Roo, M.C.D.3    Willems, J.L.4
  • 10
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • Fisel CR, Ackerman JL, Buxton RB, Garrido L, Belliveau JW, Rosen BR, Brady TJ. MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn Reson Med 1991;17:336-347.
    • (1991) Magn Reson Med , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, B.R.6    Brady, T.J.7
  • 11
    • 0028158554 scopus 로고
    • Intravascular susceptibility contrast mechanism in tissues
    • Kennan RP, Zhong J, Gore JC. Intravascular susceptibility contrast mechanism in tissues. Magn Reson Med 1994;31:9-21.
    • (1994) Magn Reson Med , vol.31 , pp. 9-21
    • Kennan, R.P.1    Zhong, J.2    Gore, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.