Volumn 27, Issue 2, 2000, Pages 346-353

Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center

Author keywords

Breathing synchronized radiotherapy; Fluoroscopic images; IMRT; Linear accelerator

Indexed keywords

DISEASES; LINEAR ACCELERATORS; ONCOLOGY; RADIOTHERAPY; SYNCHRONIZATION; VIDEO CAMERAS;

EID: 0034006554     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598837     Document Type: Article
Times cited : (279)

References (21)
  • 2
    • 0027127028 scopus 로고
    • Proton irradiation synchronized with respiratory cycle
    • in Japanese
    • T. Inada, H. Tsuji, Y. Hayakawa, A. Maruhashi, and H. Tsujii, "Proton irradiation synchronized with respiratory cycle," Nippon Acta Radiol. 52, 1161-1167 (1992) (in Japanese).
    • (1992) Nippon Acta Radiol. , vol.52 , pp. 1161-1167
    • Inada, T.1    Tsuji, H.2    Hayakawa, Y.3    Maruhashi, A.4    Tsujii, H.5
  • 3
    • 85027225734 scopus 로고    scopus 로고
    • Report on clinical investigation of cancer therapy using heavy-ion medical accelerator in Chiba
    • in Japanese
    • Report on clinical investigation of cancer therapy using heavy-ion medical accelerator in Chiba. NIRS Annual Reports, 1996-1998 (in Japanese).
    • (1996) NIRS Annual Reports
  • 6
    • 0030047783 scopus 로고    scopus 로고
    • Respiration gated radiotherapy treatment: A technical study
    • H. D. Kubo and B. C. Hill, "Respiration gated radiotherapy treatment: a technical study," Phys. Med. Biol. 41, 83-91 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 83-91
    • Kubo, H.D.1    Hill, B.C.2
  • 7
    • 33744679665 scopus 로고    scopus 로고
    • Use of breath-hold helical CT and spirometry in conformal radiotherapy treatment planning
    • J. Hanley et al., "Use of breath-hold helical CT and spirometry in conformal radiotherapy treatment planning," Radiology 201, 406 (1996).
    • (1996) Radiology , vol.201 , pp. 406
    • Hanley, J.1
  • 9
    • 0032844267 scopus 로고    scopus 로고
    • Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation
    • J. Hanley et al., "Deep inspiration breath-hold technique for lung tumors: The potential value of target immobilization and reduced lung density in dose escalation," Int. J. Radiat. Oncol., Biol., Phys. 45, 603-611 (1999).
    • (1999) Int. J. Radiat. Oncol., Biol., Phys. , vol.45 , pp. 603-611
    • Hanley, J.1
  • 11
    • 85027234062 scopus 로고    scopus 로고
    • Survey of respiration gated radiotherapy. Invited talk at the annual AAPM meeting
    • H. D. Kubo, "Survey of respiration gated radiotherapy. Invited talk at the annual AAPM meeting," Med. Phys. 25, A140 (1998).
    • (1998) Med. Phys. , vol.25
    • Kubo, H.D.1
  • 12
    • 0001460026 scopus 로고    scopus 로고
    • Design and clinical implementation of a system for respiratory gated radiotherapy
    • M. Sontag, "Design and clinical implementation of a system for respiratory gated radiotherapy," Med. Phys. 25, A126 (1998).
    • (1998) Med. Phys. , vol.25
    • Sontag, M.1
  • 13
    • 0032965071 scopus 로고    scopus 로고
    • Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy
    • R. D. Rogus, R. L. Stern, and H. D. Kubo, "Accuracy of a photogrammetry-based patient positioning and monitoring system for radiation therapy," Med. Phys. 26, 721-728 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 721-728
    • Rogus, R.D.1    Stern, R.L.2    Kubo, H.D.3
  • 14
    • 0031016807 scopus 로고    scopus 로고
    • Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    • L. E. Antonuk, Y. El-Mohri, J. H. Siewerdsen, J. Yorkston, W. Huang, and V. E. Scarpine, "Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation," Med. Phys. 24, 51-70 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 51-70
    • Antonuk, L.E.1    El-Mohri, Y.2    Siewerdsen, J.H.3    Yorkston, J.4    Huang, W.5    Scarpine, V.E.6
  • 19
    • 0343792859 scopus 로고    scopus 로고
    • Amorphous silicon dual mode medical imaging system
    • M. D. Wright et al., "Amorphous silicon dual mode medical imaging system," SPIE Proc. Phys. Med. Imaging 3336, 505-510 (1998).
    • (1998) SPIE Proc. Phys. Med. Imaging , vol.3336 , pp. 505-510
    • Wright, M.D.1
  • 20
    • 0032692401 scopus 로고    scopus 로고
    • Characteristics and role of a prototype amorphous silicon array electronic portal imaging device in breathing gated radiation treatment
    • H. D. Kubo, E. G. Shapiro, and E. J. Seppi, "Characteristics and role of a prototype amorphous silicon array electronic portal imaging device in breathing gated radiation treatment," Med. Phys. 26, 2410-2414 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2410-2414
    • Kubo, H.D.1    Shapiro, E.G.2    Seppi, E.J.3
  • 21
    • 0030157725 scopus 로고    scopus 로고
    • Measurement of patient setup errors using port films and a computer-aided graphical alignment tool
    • J. E. Schewe, J. M. Balter, K. L. Lam, and R. K. Ten Haken, "Measurement of patient setup errors using port films and a computer-aided graphical alignment tool," Med. Dosim. 21, 97-104 (1996).
    • (1996) Med. Dosim. , vol.21 , pp. 97-104
    • Schewe, J.E.1    Balter, J.M.2    Lam, K.L.3    Haken, R.K.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.