메뉴 건너뛰기




Volumn 264, Issue 7-8, 2008, Pages 701-707

Probabilistic computational modeling of total knee replacement wear

Author keywords

Computational wear simulation; Kinematics; Knee mechanics; Probabilistic; TKR

Indexed keywords

COMPUTATION THEORY; COMPUTER SIMULATION; FRICTION; MATHEMATICAL MODELS; MONTE CARLO METHODS; WEAR RESISTANCE;

EID: 38749134570     PISSN: 00431648     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.wear.2007.06.010     Document Type: Article
Times cited : (64)

References (31)
  • 2
    • 2942543100 scopus 로고    scopus 로고
    • Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis
    • Ashraf T., Newman J.H., Desai V.V., Beard D., and Nevelos J.E. Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis. Knee 11 (2004) 177-181
    • (2004) Knee , vol.11 , pp. 177-181
    • Ashraf, T.1    Newman, J.H.2    Desai, V.V.3    Beard, D.4    Nevelos, J.E.5
  • 3
    • 33746123137 scopus 로고    scopus 로고
    • Retrieval, experimental, and computational assessment of the performance of total knee replacements
    • Rawlinson J.J., Furman B.D., Li S., Wright T.M., and Bartel D.L. Retrieval, experimental, and computational assessment of the performance of total knee replacements. J. Orthop. Res. 24 (2006) 1384-1394
    • (2006) J. Orthop. Res. , vol.24 , pp. 1384-1394
    • Rawlinson, J.J.1    Furman, B.D.2    Li, S.3    Wright, T.M.4    Bartel, D.L.5
  • 4
    • 10444261188 scopus 로고    scopus 로고
    • The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    • McEwen H.M., Barnett P.I., Bell C.J., Farrar R., Auger D.D., Stone M.H., and Fisher J. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J. Biomech. 38 (2005) 357-365
    • (2005) J. Biomech. , vol.38 , pp. 357-365
    • McEwen, H.M.1    Barnett, P.I.2    Bell, C.J.3    Farrar, R.4    Auger, D.D.5    Stone, M.H.6    Fisher, J.7
  • 9
    • 0038546396 scopus 로고    scopus 로고
    • Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene
    • Mazzucco D., and Spector M. Effects of contact area and stress on the volumetric wear of ultrahigh molecular weight polyethylene. Wear 254 (2003) 514-522
    • (2003) Wear , vol.254 , pp. 514-522
    • Mazzucco, D.1    Spector, M.2
  • 10
    • 34248191184 scopus 로고    scopus 로고
    • Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control
    • Haider H., Walker P.S., DesJardins J.D., and Blunn G.W. Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control. J. ASTM Int. 3 (2006)
    • (2006) J. ASTM Int. , vol.3
    • Haider, H.1    Walker, P.S.2    DesJardins, J.D.3    Blunn, G.W.4
  • 11
    • 0030152744 scopus 로고    scopus 로고
    • A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty
    • Maxian T.A., Brown T.D., Pedersen D.R., and Callaghan J.J. A sliding-distance-coupled finite element formulation for polyethylene wear in total hip arthroplasty. J. Biomech. 29 (1996) 687-692
    • (1996) J. Biomech. , vol.29 , pp. 687-692
    • Maxian, T.A.1    Brown, T.D.2    Pedersen, D.R.3    Callaghan, J.J.4
  • 12
    • 0030198688 scopus 로고    scopus 로고
    • Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty
    • Maxian T.A., Brown T.D., Pedersen D.R., and Callaghan J.J. Adaptive finite element modeling of long-term polyethylene wear in total hip arthroplasty. Clin. Orthop. Relat. Res. 14 (1996) 668-675
    • (1996) Clin. Orthop. Relat. Res. , vol.14 , pp. 668-675
    • Maxian, T.A.1    Brown, T.D.2    Pedersen, D.R.3    Callaghan, J.J.4
  • 13
    • 13344270633 scopus 로고
    • Contact and rubbing of flat surfaces
    • Archard J.F. Contact and rubbing of flat surfaces. J. Appl. Phys. 24 (1953) 981-988
    • (1953) J. Appl. Phys. , vol.24 , pp. 981-988
    • Archard, J.F.1
  • 14
    • 0036169065 scopus 로고    scopus 로고
    • An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty
    • Teoh S.H., Chan W.H., and Thampuran R. An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. J. Biomech. 35 (2002) 323-330
    • (2002) J. Biomech. , vol.35 , pp. 323-330
    • Teoh, S.H.1    Chan, W.H.2    Thampuran, R.3
  • 16
    • 10444285036 scopus 로고    scopus 로고
    • Computational wear prediction of a total knee replacement from in vivo kinematics
    • Fregly B.J., Sawyer W.G., Harman M.K., and Banks S.A. Computational wear prediction of a total knee replacement from in vivo kinematics. J. Biomech. 38 (2005) 305-314
    • (2005) J. Biomech. , vol.38 , pp. 305-314
    • Fregly, B.J.1    Sawyer, W.G.2    Harman, M.K.3    Banks, S.A.4
  • 18
    • 0036137726 scopus 로고    scopus 로고
    • Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis
    • Godest A.C., Beaugonin M., Haug E., Taylor M., and Gregson P.J. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. J. Biomech. 35 (2002) 267-275
    • (2002) J. Biomech. , vol.35 , pp. 267-275
    • Godest, A.C.1    Beaugonin, M.2    Haug, E.3    Taylor, M.4    Gregson, P.J.5
  • 19
    • 10444255467 scopus 로고    scopus 로고
    • Explicit finite element modeling of total knee replacement mechanics
    • Halloran J.P., Petrella A.J., and Rullkoetter P.J. Explicit finite element modeling of total knee replacement mechanics. J. Biomech. 38 (2005) 323-331
    • (2005) J. Biomech. , vol.38 , pp. 323-331
    • Halloran, J.P.1    Petrella, A.J.2    Rullkoetter, P.J.3
  • 20
    • 33747137264 scopus 로고    scopus 로고
    • Probabilistic finite element prediction of knee wear simulator mechanics
    • Laz P.J., Pal S., Halloran J.P., Petrella A.J., and Rullkoetter P.J. Probabilistic finite element prediction of knee wear simulator mechanics. J. Biomech. 39 (2006) 2303-2310
    • (2006) J. Biomech. , vol.39 , pp. 2303-2310
    • Laz, P.J.1    Pal, S.2    Halloran, J.P.3    Petrella, A.J.4    Rullkoetter, P.J.5
  • 21
    • 33845893900 scopus 로고    scopus 로고
    • Effects of knee simulator loading and alignment variability on predicted implant mechanics: a probabilistic study
    • Laz P.J., Pal S., Fields A., Petrella A.J., and Rullkoetter P.J. Effects of knee simulator loading and alignment variability on predicted implant mechanics: a probabilistic study. J. Orthop. Res. 24 (2006) 2212-2221
    • (2006) J. Orthop. Res. , vol.24 , pp. 2212-2221
    • Laz, P.J.1    Pal, S.2    Fields, A.3    Petrella, A.J.4    Rullkoetter, P.J.5
  • 23
    • 0038721520 scopus 로고    scopus 로고
    • Analysis and recommendations for the optimum spring configurations for the soft tissue restraint in force-control knee simulator testing
    • Haider H., and Walker P.S. Analysis and recommendations for the optimum spring configurations for the soft tissue restraint in force-control knee simulator testing. Trans. ORS 48 (2002) 912
    • (2002) Trans. ORS , vol.48 , pp. 912
    • Haider, H.1    Walker, P.S.2
  • 24
    • 38749093581 scopus 로고    scopus 로고
    • ISO Standard 14243-2, Wear of total knee-joint prostheses. Part 2. Methods of measurement, International Standards Organization, 2000.
    • ISO Standard 14243-2, Wear of total knee-joint prostheses. Part 2. Methods of measurement, International Standards Organization, 2000.
  • 25
    • 0033773508 scopus 로고    scopus 로고
    • Selection of the best element type in the finite element analysis of hip prostheses
    • Muccini R., Baleani M., and Viceconti M. Selection of the best element type in the finite element analysis of hip prostheses. J. Med. Eng. Technol. 24 (2000) 145-148
    • (2000) J. Med. Eng. Technol. , vol.24 , pp. 145-148
    • Muccini, R.1    Baleani, M.2    Viceconti, M.3
  • 26
    • 25444453812 scopus 로고    scopus 로고
    • Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics
    • Halloran J.P., Easley S.K., Petrella A.J., and Rullkoetter P.J. Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics. J. Biomech. Eng. 127 (2005) 813-818
    • (2005) J. Biomech. Eng. , vol.127 , pp. 813-818
    • Halloran, J.P.1    Easley, S.K.2    Petrella, A.J.3    Rullkoetter, P.J.4
  • 27
    • 2142716777 scopus 로고    scopus 로고
    • A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses
    • McGloughlin T.M., Murphy D.M., and Kavanagh A.G. A machine for the preliminary investigation of design features influencing the wear behaviour of knee prostheses. Proc. Inst. Mech. Eng. [H] 218 (2004) 51-62
    • (2004) Proc. Inst. Mech. Eng. [H] , vol.218 , pp. 51-62
    • McGloughlin, T.M.1    Murphy, D.M.2    Kavanagh, A.G.3
  • 28
    • 0025488619 scopus 로고
    • Advanced probabilistic structural-analysis method for implicit performance functions
    • Wu Y.T., Millwater H.R., and Cruse T.A. Advanced probabilistic structural-analysis method for implicit performance functions. AIAA J. 28 (1990) 1663-1669
    • (1990) AIAA J. , vol.28 , pp. 1663-1669
    • Wu, Y.T.1    Millwater, H.R.2    Cruse, T.A.3
  • 30
    • 33646170703 scopus 로고    scopus 로고
    • Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty
    • Catani F., Fantozzi S., Ensini A., Leardini A., Moschella D., and Giannini S. Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty. J. Orthop. Res. 24 (2006) 581-587
    • (2006) J. Orthop. Res. , vol.24 , pp. 581-587
    • Catani, F.1    Fantozzi, S.2    Ensini, A.3    Leardini, A.4    Moschella, D.5    Giannini, S.6
  • 31
    • 0034880976 scopus 로고    scopus 로고
    • The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties
    • Mahaluxmivala J., Bankes M.J., Nicolai P., Aldam C.H., and Allen P.W. The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J. Arthroplasty 16 (2001) 635-640
    • (2001) J. Arthroplasty , vol.16 , pp. 635-640
    • Mahaluxmivala, J.1    Bankes, M.J.2    Nicolai, P.3    Aldam, C.H.4    Allen, P.W.5