Polyethylene wear in a non-congruous unicompartmental knee replacement: A retrieval analysis

Author keywords

Polyethylene wear; St Georg Sled; Unicompartmental knee replacement

Indexed keywords

POLYETHYLENE;

EID: 2942543100     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2004.03.004     Document Type: Article
Times cited : (69)

References (16)
  • 1
    • 0019955716 scopus 로고
    • The pathology of failed total joint arthroplasty
    • Mirra J.M., Mardes R.A., Amstutz The pathology of failed total joint arthroplasty. Clin. Orthop. 170:1982;175-183
    • (1982) Clin. Orthop. , vol.170 , pp. 175-183
    • Mirra, J.M.1    Mardes, R.A.2    Amstutz3
  • 2
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty: Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried T.P., Jasty M., Harris W.H. Periprosthetic bone loss in total hip arthroplasty: polyethylene wear debris and the concept of the effective joint space. J. Bone Joint Surg. 74A:1992;849-863
    • (1992) J. Bone Joint Surg. , vol.74 , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 4
    • 0026655386 scopus 로고
    • Polyethylene wear in unicondylar knee prostheses - 106 retrieved Marmor, PCA, and St Georg Tibial components compared
    • Blunn G.W., Joshi A.B., Lilley P.A., Engelbrecht E., Ryd L., Lidgren L., et al. Polyethylene wear in unicondylar knee prostheses - 106 retrieved Marmor, PCA, and St Georg Tibial components compared. Acta Orthop. Scan. 63(3):1992;247-255
    • (1992) Acta Orthop. Scan. , vol.63 , Issue.3 , pp. 247-255
    • Blunn, G.W.1    Joshi, A.B.2    Lilley, P.A.3    Engelbrecht, E.4    Ryd, L.5    Lidgren, L.6
  • 6
    • 0027972449 scopus 로고
    • Wear pattern on retrieved polyethylene tibial inserts and their relationship to technical consideration during total knee arthroplasty
    • Wasielewski R.C., Galante J.O., Leighty R.M. Wear pattern on retrieved polyethylene tibial inserts and their relationship to technical consideration during total knee arthroplasty. Clin. Orthop. 299:1994;31-43
    • (1994) Clin. Orthop. , vol.299 , pp. 31-43
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.M.3
  • 7
    • 0026574554 scopus 로고
    • Polyethylene wear in meniscal knee replacement - A one to nine year retrieval analysis of the Oxford knee
    • Argenson J.N., O'Connor J.J. Polyethylene wear in meniscal knee replacement - a one to nine year retrieval analysis of the Oxford knee. J. Bone Joint Surg. (Br). 74B:1992;228-232
    • (1992) J. Bone Joint Surg. (Br) , vol.74 , pp. 228-232
    • Argenson, J.N.1    O'Connor, J.J.2
  • 8
    • 0031734854 scopus 로고    scopus 로고
    • Wear of congruent meniscal bearing in unicompartmental knee arthroplasty - A retieval study of 16 specimen
    • Psychoyiosis V., Crawford R.W., O'Connor J.J., Murray D. Wear of congruent meniscal bearing in unicompartmental knee arthroplasty - A retieval study of 16 specimen. J. Bone Joint Surg. (Br). 80B:1998;976-982
    • (1998) J. Bone Joint Surg. (Br) , vol.80 , pp. 976-982
    • Psychoyiosis, V.1    Crawford, R.W.2    O'Connor, J.J.3    Murray, D.4
  • 11
    • 0034979120 scopus 로고    scopus 로고
    • Activity level and wear in total knee arthroplasty.A study of autopsy retrieval specimens
    • Lavernia C.J., Sierra R.J., Hungerford D.S., Krackow K. Activity level and wear in total knee arthroplasty.A study of autopsy retrieval specimens. J. Arthroplasty. 16(4):2001;446-453
    • (2001) J. Arthroplasty , vol.16 , Issue.4 , pp. 446-453
    • Lavernia, C.J.1    Sierra, R.J.2    Hungerford, D.S.3    Krackow, K.4
  • 12
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low friction arthroplasty
    • Wroblewski B.M. Direction and rate of socket wear in Charnley low friction arthroplasty. J. Bone J. Surg. (Br). 67-B:1985;757-761
    • (1985) J. Bone J. Surg. (Br) , vol.67 , pp. 757-761
    • Wroblewski, B.M.1
  • 13
    • 0036563311 scopus 로고    scopus 로고
    • Total hip replacement with a cementless acetabuluar component and a cemented femoral component in patients younger than fifty years of age
    • Kim Y.-H., Kook H.-K., Kim J.S. Total hip replacement with a cementless acetabuluar component and a cemented femoral component in patients younger than fifty years of age. J. Bone Joint Surg (A). 84A:2002;770-775
    • (2002) J. Bone Joint Surg (A) , vol.84 , pp. 770-775
    • Kim, Y.-H.1    Kook, H.-K.2    Kim, J.S.3
  • 14
    • 0024103556 scopus 로고
    • Bearing surface design in total knee replacement
    • Walker P.S. Bearing surface design in total knee replacement. Eng. Med. 17:1988;149-156
    • (1988) Eng. Med. , vol.17 , pp. 149-156
    • Walker, P.S.1
  • 15
    • 0033946299 scopus 로고    scopus 로고
    • Unicompartmental arthroplasty - Results in Sweden 1986-95
    • Robertson O. Unicompartmental arthroplasty - results in Sweden 1986-95. Der Orthopade Suppl. 29:2000;S6-S8
    • (2000) Der Orthopade Suppl. , vol.29 , pp. 6-S8
    • Robertson, O.1
  • 16
    • 0027185807 scopus 로고
    • Tibial high-density polyethylene wear in conforming tibiofemoral prostheses
    • Plante-Bordeneuve P., Freeman M.A.R. Tibial high-density polyethylene wear in conforming tibiofemoral prostheses. J. Bone Joint Surg. (Br). 75B:1993;630-636
    • (1993) J. Bone Joint Surg. (Br) , vol.75 , pp. 630-636
    • Plante-Bordeneuve, P.1    Freeman, M.A.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.