The Effect of Humidification on the Incidence of Ventilator-associated Pneumonia

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL VENTILATION; BACTERIAL COLONIZATION; COST CONTROL; HUMAN; HUMIDIFIER; INCIDENCE; INFECTION CONTROL; INTENSIVE CARE; LONG TERM EXPOSURE; MEDICAL INSTRUMENTATION; MICROBIAL CONTAMINATION; REVIEW; RISK ASSESSMENT; VENTILATOR; VENTILATOR ASSOCIATED PNEUMONIA;

EID: 33745647602     PISSN: 10785337     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.rcc.2006.03.007     Document Type: Review
Times cited : (18)

References (56)
  • 2
    • 0342598856 scopus 로고
    • The potential role of inhalation therapy equipment in nosocomial pulmonary infection
    • Reinarz J.A., Pierce A.K., Mays B.B., et al. The potential role of inhalation therapy equipment in nosocomial pulmonary infection. J Clin Invest 44 (1965) 831-839
    • (1965) J Clin Invest , vol.44 , pp. 831-839
    • Reinarz, J.A.1    Pierce, A.K.2    Mays, B.B.3
  • 3
    • 0014066288 scopus 로고
    • A hospital outbreak of Klebsiella pneumonia from inhalation therapy with contaminated aerosol solutions
    • Mertz J.J., Scharer L., and McClement J.H. A hospital outbreak of Klebsiella pneumonia from inhalation therapy with contaminated aerosol solutions. Am Rev Respir Dis 95 (1967) 454-460
    • (1967) Am Rev Respir Dis , vol.95 , pp. 454-460
    • Mertz, J.J.1    Scharer, L.2    McClement, J.H.3
  • 4
    • 0014933148 scopus 로고
    • Fine-particle humidifiers. Source of Pseudomonas aeruginosa infections in a respiratory-disease unit
    • Grieble H.G., Colton F.R., Bird T.J., et al. Fine-particle humidifiers. Source of Pseudomonas aeruginosa infections in a respiratory-disease unit. N Engl J Med 282 (1970) 531-535
    • (1970) N Engl J Med , vol.282 , pp. 531-535
    • Grieble, H.G.1    Colton, F.R.2    Bird, T.J.3
  • 5
    • 0015547015 scopus 로고
    • Bacterial contamination of aerosols
    • Pierce A.K., and Sanford J.P. Bacterial contamination of aerosols. Arch Intern Med 131 (1973) 156-159
    • (1973) Arch Intern Med , vol.131 , pp. 156-159
    • Pierce, A.K.1    Sanford, J.P.2
  • 6
    • 0032507210 scopus 로고    scopus 로고
    • Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials
    • Cook D., De Jonghe B., Brochard L., et al. Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279 (1998) 781-787
    • (1998) JAMA , vol.279 , pp. 781-787
    • Cook, D.1    De Jonghe, B.2    Brochard, L.3
  • 7
    • 12944296648 scopus 로고    scopus 로고
    • Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials
    • Kola A., Eckmanns T., and Gastmeier P. Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials. Intensive Care Med 31 (2005) 5-11
    • (2005) Intensive Care Med , vol.31 , pp. 5-11
    • Kola, A.1    Eckmanns, T.2    Gastmeier, P.3
  • 8
    • 0036284869 scopus 로고    scopus 로고
    • Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey
    • Ricard J.D., Cook D., Griffith L., Brochard L., et al. Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey. Intensive Care Med 28 (2002) 719-725
    • (2002) Intensive Care Med , vol.28 , pp. 719-725
    • Ricard, J.D.1    Cook, D.2    Griffith, L.3    Brochard, L.4
  • 9
    • 0033782961 scopus 로고    scopus 로고
    • Ventilator circuit and secretion management strategies: a Franco-Canadian survey
    • Cook D., Ricard J.D., Reeve B., et al. Ventilator circuit and secretion management strategies: a Franco-Canadian survey. Crit Care Med 28 (2000) 3547-3554
    • (2000) Crit Care Med , vol.28 , pp. 3547-3554
    • Cook, D.1    Ricard, J.D.2    Reeve, B.3
  • 10
    • 0002340407 scopus 로고    scopus 로고
    • Cost associated with mechanical ventilation
    • Hill N.S., and Levy M.M. (Eds), Marcel Dekker, New York
    • McGee W.T. Cost associated with mechanical ventilation. In: Hill N.S., and Levy M.M. (Eds). Ventilator management strategies for critical care, vol. 158 (2001), Marcel Dekker, New York 79-106
    • (2001) Ventilator management strategies for critical care, vol. 158 , pp. 79-106
    • McGee, W.T.1
  • 11
    • 0021275019 scopus 로고
    • Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia
    • Craven D.E., Goularte T.A., and Make B.J. Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia. Am Rev Respir Dis 129 (1984) 625-628
    • (1984) Am Rev Respir Dis , vol.129 , pp. 625-628
    • Craven, D.E.1    Goularte, T.A.2    Make, B.J.3
  • 12
    • 0022622761 scopus 로고
    • Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation
    • Craven D.E., Kunches L.M., Kilinsky V., et al. Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Respir Dis 133 (1986) 792-796
    • (1986) Am Rev Respir Dis , vol.133 , pp. 792-796
    • Craven, D.E.1    Kunches, L.M.2    Kilinsky, V.3
  • 13
    • 0019596116 scopus 로고
    • Contamination rate of sterilized ventilators in an ICU
    • Comhaire A., and Lamy M. Contamination rate of sterilized ventilators in an ICU. Crit Care Med 9 (1981) 546-548
    • (1981) Crit Care Med , vol.9 , pp. 546-548
    • Comhaire, A.1    Lamy, M.2
  • 14
    • 0020619954 scopus 로고
    • The potential role of respiratory therapy equipment in cross infection. A study using a canine model for pneumonia
    • Christopher K.L., Saravolatz L.D., Bush T.L., et al. The potential role of respiratory therapy equipment in cross infection. A study using a canine model for pneumonia. Am Rev Respir Dis 128 (1983) 271-275
    • (1983) Am Rev Respir Dis , vol.128 , pp. 271-275
    • Christopher, K.L.1    Saravolatz, L.D.2    Bush, T.L.3
  • 15
    • 0020083698 scopus 로고
    • Contamination of mechanical ventilators with tubing changes every 24 or 48 hours
    • Craven D.E., Connolly Jr. M.G., Lichtenberg D.A., et al. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med 306 (1982) 1505-1509
    • (1982) N Engl J Med , vol.306 , pp. 1505-1509
    • Craven, D.E.1    Connolly Jr., M.G.2    Lichtenberg, D.A.3
  • 16
    • 0345024323 scopus 로고    scopus 로고
    • New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers
    • Ricard J.-D., Hidri N., Blivet A., et al. New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers. Am J Respir Crit Care Med 167 (2003) A861
    • (2003) Am J Respir Crit Care Med , vol.167
    • Ricard, J.-D.1    Hidri, N.2    Blivet, A.3
  • 17
    • 0018161409 scopus 로고
    • The relationship between frequency of ventilator circuit changes and infectious hazard
    • Lareau S.C., Ryan K.J., and Diener C.F. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis 118 (1978) 493-496
    • (1978) Am Rev Respir Dis , vol.118 , pp. 493-496
    • Lareau, S.C.1    Ryan, K.J.2    Diener, C.F.3
  • 18
    • 0025980586 scopus 로고
    • Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change
    • Dreyfuss D., Djedaini K., Weber P., et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis 143 (1991) 738-743
    • (1991) Am Rev Respir Dis , vol.143 , pp. 738-743
    • Dreyfuss, D.1    Djedaini, K.2    Weber, P.3
  • 19
    • 0028943271 scopus 로고
    • Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates
    • Hess D., Burns E., Romagnoli D., et al. Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates. Anesthesiology 82 (1995) 903-911
    • (1995) Anesthesiology , vol.82 , pp. 903-911
    • Hess, D.1    Burns, E.2    Romagnoli, D.3
  • 20
    • 0029090682 scopus 로고
    • Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial
    • Kollef M.H., Shapiro S.D., Fraser V.J., et al. Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial. Ann Intern Med 123 (1995) 168-174
    • (1995) Ann Intern Med , vol.123 , pp. 168-174
    • Kollef, M.H.1    Shapiro, S.D.2    Fraser, V.J.3
  • 21
    • 0029692820 scopus 로고    scopus 로고
    • Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week
    • Long M.N., Wickstrom G., Grimes A., et al. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week. Infect Control Hosp Epidemiol 17 (1996) 14-19
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 14-19
    • Long, M.N.1    Wickstrom, G.2    Grimes, A.3
  • 22
    • 0030971809 scopus 로고    scopus 로고
    • Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit
    • Kotilainen H.R., and Keroack M.A. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit. Am J Infect Control 25 (1997) 117-120
    • (1997) Am J Infect Control , vol.25 , pp. 117-120
    • Kotilainen, H.R.1    Keroack, M.A.2
  • 23
    • 0020160494 scopus 로고
    • Guideline for prevention of nosocomial pneumonia
    • Simmons B.P., and Wong E.S. Guideline for prevention of nosocomial pneumonia. Infect Control 3 (1982) 327-333
    • (1982) Infect Control , vol.3 , pp. 327-333
    • Simmons, B.P.1    Wong, E.S.2
  • 24
    • 1642525257 scopus 로고    scopus 로고
    • Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee
    • Tablan O.C., Anderson L.J., Besser R., et al. Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 53 RR-3 (2004) 1-36
    • (2004) MMWR Recomm Rep , vol.53 , Issue.RR-3 , pp. 1-36
    • Tablan, O.C.1    Anderson, L.J.2    Besser, R.3
  • 25
    • 0025015270 scopus 로고
    • Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
    • Martin C., Perrin G., Gevaudan M.J., et al. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97 (1990) 144-149
    • (1990) Chest , vol.97 , pp. 144-149
    • Martin, C.1    Perrin, G.2    Gevaudan, M.J.3
  • 26
    • 0027451823 scopus 로고
    • Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier
    • Branson R.D., Davis K.J., Campbell R.S., et al. Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 104 (1993) 1800-1805
    • (1993) Chest , vol.104 , pp. 1800-1805
    • Branson, R.D.1    Davis, K.J.2    Campbell, R.S.3
  • 27
    • 0028968722 scopus 로고
    • Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia
    • Dreyfuss D., Djedaini K., Gros I., et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151 (1995) 986-992
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 986-992
    • Dreyfuss, D.1    Djedaini, K.2    Gros, I.3
  • 28
    • 0030874818 scopus 로고    scopus 로고
    • Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
    • Boots R.J., Howe S., George N., et al. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25 (1997) 1707-1712
    • (1997) Crit Care Med , vol.25 , pp. 1707-1712
    • Boots, R.J.1    Howe, S.2    George, N.3
  • 29
    • 0026611461 scopus 로고
    • Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
    • Roustan J.P., Kienlen J., Aubas P., et al. Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18 (1992) 97-100
    • (1992) Intensive Care Med , vol.18 , pp. 97-100
    • Roustan, J.P.1    Kienlen, J.2    Aubas, P.3
  • 30
    • 0029831013 scopus 로고    scopus 로고
    • Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations
    • Branson R.D., Davis K.J., Brown R., et al. Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41 (1996) 809-816
    • (1996) Respir Care , vol.41 , pp. 809-816
    • Branson, R.D.1    Davis, K.J.2    Brown, R.3
  • 31
    • 0030879788 scopus 로고    scopus 로고
    • A prospective, randomized comparison of an in-line heat and moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
    • Kirton O., DeHaven B., Morgan J., et al. A prospective, randomized comparison of an in-line heat and moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112 (1998) 1055-1059
    • (1998) Chest , vol.112 , pp. 1055-1059
    • Kirton, O.1    DeHaven, B.2    Morgan, J.3
  • 32
    • 0031888824 scopus 로고    scopus 로고
    • A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
    • Kollef M., Shapiro S., Boyd V., et al. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113 (1998) 759-767
    • (1998) Chest , vol.113 , pp. 759-767
    • Kollef, M.1    Shapiro, S.2    Boyd, V.3
  • 33
    • 0034797673 scopus 로고    scopus 로고
    • A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia
    • Memish Z.A., Oni G.A., Djazmati W., et al. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29 (2001) 301-305
    • (2001) Am J Infect Control , vol.29 , pp. 301-305
    • Memish, Z.A.1    Oni, G.A.2    Djazmati, W.3
  • 34
    • 30444447238 scopus 로고    scopus 로고
    • Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial
    • Lacherade J.C., Auburtin M., Cerf C., et al. Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial. Am J Respir Crit Care Med 172 (2005) 1276-1282
    • (2005) Am J Respir Crit Care Med , vol.172 , pp. 1276-1282
    • Lacherade, J.C.1    Auburtin, M.2    Cerf, C.3
  • 35
    • 0037348565 scopus 로고    scopus 로고
    • Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study
    • Boyer A., Thiery G., Lasry S., et al. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study. Crit Care Med 31 (2003) 823-829
    • (2003) Crit Care Med , vol.31 , pp. 823-829
    • Boyer, A.1    Thiery, G.2    Lasry, S.3
  • 36
    • 0036924301 scopus 로고    scopus 로고
    • Epidemiology and outcomes of ventilator-associated pneumonia in a large US database
    • Rello J., Ollendorf D.A., Oster G., et al. Epidemiology and outcomes of ventilator-associated pneumonia in a large US database. Chest 122 (2002) 2115-2121
    • (2002) Chest , vol.122 , pp. 2115-2121
    • Rello, J.1    Ollendorf, D.A.2    Oster, G.3
  • 37
    • 0033040999 scopus 로고    scopus 로고
    • Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill
    • Ricard J.-D., Markowicz P., Djedaïni K., et al. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Chest 115 (1999) 1646-1652
    • (1999) Chest , vol.115 , pp. 1646-1652
    • Ricard, J.-D.1    Markowicz, P.2    Djedaïni, K.3
  • 38
    • 0033968236 scopus 로고    scopus 로고
    • Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week
    • Ricard J.-D., Le Mière E., Markowicz P., et al. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161 (2000) 104-109
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 104-109
    • Ricard, J.-D.1    Le Mière, E.2    Markowicz, P.3
  • 39
    • 0029174060 scopus 로고
    • Changing heat and moisture exchangers every 48 hours rather than every 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
    • Djedaïni K., Billiard M., Mier L., et al. Changing heat and moisture exchangers every 48 hours rather than every 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 152 (1995) 1562-1569
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1562-1569
    • Djedaïni, K.1    Billiard, M.2    Mier, L.3
  • 40
    • 0033124708 scopus 로고    scopus 로고
    • Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia
    • Daumal F., Colpart E., Manoury B., et al. Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia. Infect Control Hosp Epidemiol 20 (1999) 347-349
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 347-349
    • Daumal, F.1    Colpart, E.2    Manoury, B.3
  • 41
    • 0034103469 scopus 로고    scopus 로고
    • Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study
    • Markowicz P., Ricard J.-D., Dreyfuss D., et al. Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med 28 (2000) 665-671
    • (2000) Crit Care Med , vol.28 , pp. 665-671
    • Markowicz, P.1    Ricard, J.-D.2    Dreyfuss, D.3
  • 42
    • 0034112596 scopus 로고    scopus 로고
    • Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
    • Davis Jr. K., Evans S.L., Campbell R.S., et al. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28 (2000) 1412-1418
    • (2000) Crit Care Med , vol.28 , pp. 1412-1418
    • Davis Jr., K.1    Evans, S.L.2    Campbell, R.S.3
  • 43
    • 0034022538 scopus 로고    scopus 로고
    • Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation
    • Thomachot L., Boisson C., Arnaud S., et al. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 28 (2000) 714-720
    • (2000) Crit Care Med , vol.28 , pp. 714-720
    • Thomachot, L.1    Boisson, C.2    Arnaud, S.3
  • 44
    • 0036155170 scopus 로고    scopus 로고
    • Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
    • Thomachot L., Leone M., Razzouk K., et al. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 30 (2002) 232-237
    • (2002) Crit Care Med , vol.30 , pp. 232-237
    • Thomachot, L.1    Leone, M.2    Razzouk, K.3
  • 45
    • 0031733848 scopus 로고    scopus 로고
    • Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia
    • Thomachot L., Viviand X., Arnaud S., et al. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 114 (1998) 1383-1389
    • (1998) Chest , vol.114 , pp. 1383-1389
    • Thomachot, L.1    Viviand, X.2    Arnaud, S.3
  • 46
    • 0033030246 scopus 로고    scopus 로고
    • Do components of heat and moisture exchangers filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
    • Thomachot L., Vialet R., Arnaud S., et al. Do components of heat and moisture exchangers filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?. Crit Care Med 27 (1999) 923-928
    • (1999) Crit Care Med , vol.27 , pp. 923-928
    • Thomachot, L.1    Vialet, R.2    Arnaud, S.3
  • 47
    • 8444237099 scopus 로고    scopus 로고
    • Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers
    • Lellouche F., Taille S., Maggiore S.M., et al. Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. Am J Respir Crit Care Med 170 (2004) 1073-1079
    • (2004) Am J Respir Crit Care Med , vol.170 , pp. 1073-1079
    • Lellouche, F.1    Taille, S.2    Maggiore, S.M.3
  • 48
    • 0037453115 scopus 로고    scopus 로고
    • Prevention of ventilator-associated pneumonia: an evidence-based systematic review
    • Collard H.R., Saint S., and Matthay M.A. Prevention of ventilator-associated pneumonia: an evidence-based systematic review. Ann Intern Med 138 (2003) 494-501
    • (2003) Ann Intern Med , vol.138 , pp. 494-501
    • Collard, H.R.1    Saint, S.2    Matthay, M.A.3
  • 49
    • 4043130212 scopus 로고    scopus 로고
    • Evidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia
    • Dodek P., Keenan S., Cook D., et al. Evidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia. Ann Intern Med 141 (2004) 305-313
    • (2004) Ann Intern Med , vol.141 , pp. 305-313
    • Dodek, P.1    Keenan, S.2    Cook, D.3
  • 50
    • 0033602066 scopus 로고    scopus 로고
    • The prevention of ventilator-associated pneumonia
    • Kollef M. The prevention of ventilator-associated pneumonia. N Engl J Med 340 (1999) 627-634
    • (1999) N Engl J Med , vol.340 , pp. 627-634
    • Kollef, M.1
  • 51
    • 0036902243 scopus 로고    scopus 로고
    • Statement of the 4th International Consensus Conference in Critical Care on ICU-Acquired Pneumonia. Chicago, Illinois, May 2002
    • Hubmayr R.D., Burchardi H., Elliot M., et al. Statement of the 4th International Consensus Conference in Critical Care on ICU-Acquired Pneumonia. Chicago, Illinois, May 2002. Intensive Care Med 28 (2002) 1521-1536
    • (2002) Intensive Care Med , vol.28 , pp. 1521-1536
    • Hubmayr, R.D.1    Burchardi, H.2    Elliot, M.3
  • 52
    • 1542394258 scopus 로고    scopus 로고
    • Care of the ventilator circuit and its relation to ventilator-associated pneumonia
    • Hess D.R., Kallstrom T.J., Mottram C.D., et al. Care of the ventilator circuit and its relation to ventilator-associated pneumonia. Respir Care 48 (2003) 869-879
    • (2003) Respir Care , vol.48 , pp. 869-879
    • Hess, D.R.1    Kallstrom, T.J.2    Mottram, C.D.3
  • 53
    • 1542358083 scopus 로고    scopus 로고
    • Prevention of ventilator-associated pneumonia
    • [authors' reply: 486-7]
    • Ricard J.D., and Dreyfuss D. Prevention of ventilator-associated pneumonia. Ann Intern Med 140 (2004) 486 [authors' reply: 486-7]
    • (2004) Ann Intern Med , vol.140 , pp. 486
    • Ricard, J.D.1    Dreyfuss, D.2
  • 54
    • 1642533565 scopus 로고    scopus 로고
    • Ventilatory management of acute respiratory distress syndrome: a consensus of two
    • Marini J.J., and Gattinoni L. Ventilatory management of acute respiratory distress syndrome: a consensus of two. Crit Care Med 32 (2004) 250-255
    • (2004) Crit Care Med , vol.32 , pp. 250-255
    • Marini, J.J.1    Gattinoni, L.2
  • 55
    • 0032085279 scopus 로고    scopus 로고
    • The role of filtration during humidification
    • Richards G. The role of filtration during humidification. Respir Care Clin N Am 4 (1998) 329-339
    • (1998) Respir Care Clin N Am , vol.4 , pp. 329-339
    • Richards, G.1
  • 56
    • 33745659319 scopus 로고    scopus 로고
    • Ricard J-D. Humidification. In: Tobin M, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill; in press.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.