The potential role of inhalation therapy equipment in nosocomial pulmonary infection
-
Reinarz J.A., Pierce A.K., Mays B.B., et al. The potential role of inhalation therapy equipment in nosocomial pulmonary infection. J Clin Invest 44 (1965) 831-839
-
(1965)
J Clin Invest
, vol.44
, pp. 831-839
-
-
Reinarz, J.A.1
Pierce, A.K.2
Mays, B.B.3
-
3
-
-
0014066288
-
A hospital outbreak of Klebsiella pneumonia from inhalation therapy with contaminated aerosol solutions
-
Mertz J.J., Scharer L., and McClement J.H. A hospital outbreak of Klebsiella pneumonia from inhalation therapy with contaminated aerosol solutions. Am Rev Respir Dis 95 (1967) 454-460
-
(1967)
Am Rev Respir Dis
, vol.95
, pp. 454-460
-
-
Mertz, J.J.1
Scharer, L.2
McClement, J.H.3
-
4
-
-
0014933148
-
Fine-particle humidifiers. Source of Pseudomonas aeruginosa infections in a respiratory-disease unit
-
Grieble H.G., Colton F.R., Bird T.J., et al. Fine-particle humidifiers. Source of Pseudomonas aeruginosa infections in a respiratory-disease unit. N Engl J Med 282 (1970) 531-535
-
(1970)
N Engl J Med
, vol.282
, pp. 531-535
-
-
Grieble, H.G.1
Colton, F.R.2
Bird, T.J.3
-
5
-
-
0015547015
-
Bacterial contamination of aerosols
-
Pierce A.K., and Sanford J.P. Bacterial contamination of aerosols. Arch Intern Med 131 (1973) 156-159
-
(1973)
Arch Intern Med
, vol.131
, pp. 156-159
-
-
Pierce, A.K.1
Sanford, J.P.2
-
6
-
-
0032507210
-
Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials
-
Cook D., De Jonghe B., Brochard L., et al. Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279 (1998) 781-787
-
(1998)
JAMA
, vol.279
, pp. 781-787
-
-
Cook, D.1
De Jonghe, B.2
Brochard, L.3
-
7
-
-
12944296648
-
Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials
-
Kola A., Eckmanns T., and Gastmeier P. Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials. Intensive Care Med 31 (2005) 5-11
-
(2005)
Intensive Care Med
, vol.31
, pp. 5-11
-
-
Kola, A.1
Eckmanns, T.2
Gastmeier, P.3
-
8
-
-
0036284869
-
Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey
-
Ricard J.D., Cook D., Griffith L., Brochard L., et al. Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey. Intensive Care Med 28 (2002) 719-725
-
(2002)
Intensive Care Med
, vol.28
, pp. 719-725
-
-
Ricard, J.D.1
Cook, D.2
Griffith, L.3
Brochard, L.4
-
9
-
-
0033782961
-
Ventilator circuit and secretion management strategies: a Franco-Canadian survey
-
Cook D., Ricard J.D., Reeve B., et al. Ventilator circuit and secretion management strategies: a Franco-Canadian survey. Crit Care Med 28 (2000) 3547-3554
-
(2000)
Crit Care Med
, vol.28
, pp. 3547-3554
-
-
Cook, D.1
Ricard, J.D.2
Reeve, B.3
-
10
-
-
0002340407
-
Cost associated with mechanical ventilation
-
Hill N.S., and Levy M.M. (Eds), Marcel Dekker, New York
-
McGee W.T. Cost associated with mechanical ventilation. In: Hill N.S., and Levy M.M. (Eds). Ventilator management strategies for critical care, vol. 158 (2001), Marcel Dekker, New York 79-106
-
(2001)
Ventilator management strategies for critical care, vol. 158
, pp. 79-106
-
-
McGee, W.T.1
-
11
-
-
0021275019
-
Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia
-
Craven D.E., Goularte T.A., and Make B.J. Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia. Am Rev Respir Dis 129 (1984) 625-628
-
(1984)
Am Rev Respir Dis
, vol.129
, pp. 625-628
-
-
Craven, D.E.1
Goularte, T.A.2
Make, B.J.3
-
12
-
-
0022622761
-
Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation
-
Craven D.E., Kunches L.M., Kilinsky V., et al. Risk factors for pneumonia and fatality in patients receiving continuous mechanical ventilation. Am Rev Respir Dis 133 (1986) 792-796
-
(1986)
Am Rev Respir Dis
, vol.133
, pp. 792-796
-
-
Craven, D.E.1
Kunches, L.M.2
Kilinsky, V.3
-
13
-
-
0019596116
-
Contamination rate of sterilized ventilators in an ICU
-
Comhaire A., and Lamy M. Contamination rate of sterilized ventilators in an ICU. Crit Care Med 9 (1981) 546-548
-
(1981)
Crit Care Med
, vol.9
, pp. 546-548
-
-
Comhaire, A.1
Lamy, M.2
-
14
-
-
0020619954
-
The potential role of respiratory therapy equipment in cross infection. A study using a canine model for pneumonia
-
Christopher K.L., Saravolatz L.D., Bush T.L., et al. The potential role of respiratory therapy equipment in cross infection. A study using a canine model for pneumonia. Am Rev Respir Dis 128 (1983) 271-275
-
(1983)
Am Rev Respir Dis
, vol.128
, pp. 271-275
-
-
Christopher, K.L.1
Saravolatz, L.D.2
Bush, T.L.3
-
15
-
-
0020083698
-
Contamination of mechanical ventilators with tubing changes every 24 or 48 hours
-
Craven D.E., Connolly Jr. M.G., Lichtenberg D.A., et al. Contamination of mechanical ventilators with tubing changes every 24 or 48 hours. N Engl J Med 306 (1982) 1505-1509
-
(1982)
N Engl J Med
, vol.306
, pp. 1505-1509
-
-
Craven, D.E.1
Connolly Jr., M.G.2
Lichtenberg, D.A.3
-
16
-
-
0345024323
-
New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers
-
Ricard J.-D., Hidri N., Blivet A., et al. New heated breathing circuits do not prevent condensation and contamination of ventilator circuits with heated humidifiers. Am J Respir Crit Care Med 167 (2003) A861
-
(2003)
Am J Respir Crit Care Med
, vol.167
-
-
Ricard, J.-D.1
Hidri, N.2
Blivet, A.3
-
17
-
-
0018161409
-
The relationship between frequency of ventilator circuit changes and infectious hazard
-
Lareau S.C., Ryan K.J., and Diener C.F. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis 118 (1978) 493-496
-
(1978)
Am Rev Respir Dis
, vol.118
, pp. 493-496
-
-
Lareau, S.C.1
Ryan, K.J.2
Diener, C.F.3
-
18
-
-
0025980586
-
Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change
-
Dreyfuss D., Djedaini K., Weber P., et al. Prospective study of nosocomial pneumonia and of patient and circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis 143 (1991) 738-743
-
(1991)
Am Rev Respir Dis
, vol.143
, pp. 738-743
-
-
Dreyfuss, D.1
Djedaini, K.2
Weber, P.3
-
19
-
-
0028943271
-
Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates
-
Hess D., Burns E., Romagnoli D., et al. Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates. Anesthesiology 82 (1995) 903-911
-
(1995)
Anesthesiology
, vol.82
, pp. 903-911
-
-
Hess, D.1
Burns, E.2
Romagnoli, D.3
-
20
-
-
0029090682
-
Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial
-
Kollef M.H., Shapiro S.D., Fraser V.J., et al. Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial. Ann Intern Med 123 (1995) 168-174
-
(1995)
Ann Intern Med
, vol.123
, pp. 168-174
-
-
Kollef, M.H.1
Shapiro, S.D.2
Fraser, V.J.3
-
21
-
-
0029692820
-
Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week
-
Long M.N., Wickstrom G., Grimes A., et al. Prospective, randomized study of ventilator-associated pneumonia in patients with one versus three ventilator circuit changes per week. Infect Control Hosp Epidemiol 17 (1996) 14-19
-
(1996)
Infect Control Hosp Epidemiol
, vol.17
, pp. 14-19
-
-
Long, M.N.1
Wickstrom, G.2
Grimes, A.3
-
22
-
-
0030971809
-
Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit
-
Kotilainen H.R., and Keroack M.A. Cost analysis and clinical impact of weekly ventilator circuit changes in patients in intensive care unit. Am J Infect Control 25 (1997) 117-120
-
(1997)
Am J Infect Control
, vol.25
, pp. 117-120
-
-
Kotilainen, H.R.1
Keroack, M.A.2
-
23
-
-
0020160494
-
Guideline for prevention of nosocomial pneumonia
-
Simmons B.P., and Wong E.S. Guideline for prevention of nosocomial pneumonia. Infect Control 3 (1982) 327-333
-
(1982)
Infect Control
, vol.3
, pp. 327-333
-
-
Simmons, B.P.1
Wong, E.S.2
-
24
-
-
1642525257
-
Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee
-
Tablan O.C., Anderson L.J., Besser R., et al. Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 53 RR-3 (2004) 1-36
-
(2004)
MMWR Recomm Rep
, vol.53
, Issue.RR-3
, pp. 1-36
-
-
Tablan, O.C.1
Anderson, L.J.2
Besser, R.3
-
25
-
-
0025015270
-
Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit
-
Martin C., Perrin G., Gevaudan M.J., et al. Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97 (1990) 144-149
-
(1990)
Chest
, vol.97
, pp. 144-149
-
-
Martin, C.1
Perrin, G.2
Gevaudan, M.J.3
-
26
-
-
0027451823
-
Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier
-
Branson R.D., Davis K.J., Campbell R.S., et al. Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 104 (1993) 1800-1805
-
(1993)
Chest
, vol.104
, pp. 1800-1805
-
-
Branson, R.D.1
Davis, K.J.2
Campbell, R.S.3
-
27
-
-
0028968722
-
Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia
-
Dreyfuss D., Djedaini K., Gros I., et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151 (1995) 986-992
-
(1995)
Am J Respir Crit Care Med
, vol.151
, pp. 986-992
-
-
Dreyfuss, D.1
Djedaini, K.2
Gros, I.3
-
28
-
-
0030874818
-
Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients
-
Boots R.J., Howe S., George N., et al. Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25 (1997) 1707-1712
-
(1997)
Crit Care Med
, vol.25
, pp. 1707-1712
-
-
Boots, R.J.1
Howe, S.2
George, N.3
-
29
-
-
0026611461
-
Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation
-
Roustan J.P., Kienlen J., Aubas P., et al. Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18 (1992) 97-100
-
(1992)
Intensive Care Med
, vol.18
, pp. 97-100
-
-
Roustan, J.P.1
Kienlen, J.2
Aubas, P.3
-
30
-
-
0029831013
-
Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations
-
Branson R.D., Davis K.J., Brown R., et al. Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41 (1996) 809-816
-
(1996)
Respir Care
, vol.41
, pp. 809-816
-
-
Branson, R.D.1
Davis, K.J.2
Brown, R.3
-
31
-
-
0030879788
-
A prospective, randomized comparison of an in-line heat and moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion
-
Kirton O., DeHaven B., Morgan J., et al. A prospective, randomized comparison of an in-line heat and moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112 (1998) 1055-1059
-
(1998)
Chest
, vol.112
, pp. 1055-1059
-
-
Kirton, O.1
DeHaven, B.2
Morgan, J.3
-
32
-
-
0031888824
-
A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients
-
Kollef M., Shapiro S., Boyd V., et al. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113 (1998) 759-767
-
(1998)
Chest
, vol.113
, pp. 759-767
-
-
Kollef, M.1
Shapiro, S.2
Boyd, V.3
-
33
-
-
0034797673
-
A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia
-
Memish Z.A., Oni G.A., Djazmati W., et al. A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29 (2001) 301-305
-
(2001)
Am J Infect Control
, vol.29
, pp. 301-305
-
-
Memish, Z.A.1
Oni, G.A.2
Djazmati, W.3
-
34
-
-
30444447238
-
Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial
-
Lacherade J.C., Auburtin M., Cerf C., et al. Impact of humidification systems on ventilator-associated pneumonia: a randomized multicenter trial. Am J Respir Crit Care Med 172 (2005) 1276-1282
-
(2005)
Am J Respir Crit Care Med
, vol.172
, pp. 1276-1282
-
-
Lacherade, J.C.1
Auburtin, M.2
Cerf, C.3
-
35
-
-
0037348565
-
Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study
-
Boyer A., Thiery G., Lasry S., et al. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study. Crit Care Med 31 (2003) 823-829
-
(2003)
Crit Care Med
, vol.31
, pp. 823-829
-
-
Boyer, A.1
Thiery, G.2
Lasry, S.3
-
36
-
-
0036924301
-
Epidemiology and outcomes of ventilator-associated pneumonia in a large US database
-
Rello J., Ollendorf D.A., Oster G., et al. Epidemiology and outcomes of ventilator-associated pneumonia in a large US database. Chest 122 (2002) 2115-2121
-
(2002)
Chest
, vol.122
, pp. 2115-2121
-
-
Rello, J.1
Ollendorf, D.A.2
Oster, G.3
-
37
-
-
0033040999
-
Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill
-
Ricard J.-D., Markowicz P., Djedaïni K., et al. Bedside evaluation of efficient airway humidification during mechanical ventilation of the critically ill. Chest 115 (1999) 1646-1652
-
(1999)
Chest
, vol.115
, pp. 1646-1652
-
-
Ricard, J.-D.1
Markowicz, P.2
Djedaïni, K.3
-
38
-
-
0033968236
-
Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week
-
Ricard J.-D., Le Mière E., Markowicz P., et al. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161 (2000) 104-109
-
(2000)
Am J Respir Crit Care Med
, vol.161
, pp. 104-109
-
-
Ricard, J.-D.1
Le Mière, E.2
Markowicz, P.3
-
39
-
-
0029174060
-
Changing heat and moisture exchangers every 48 hours rather than every 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia
-
Djedaïni K., Billiard M., Mier L., et al. Changing heat and moisture exchangers every 48 hours rather than every 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 152 (1995) 1562-1569
-
(1995)
Am J Respir Crit Care Med
, vol.152
, pp. 1562-1569
-
-
Djedaïni, K.1
Billiard, M.2
Mier, L.3
-
40
-
-
0033124708
-
Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia
-
Daumal F., Colpart E., Manoury B., et al. Changing heat and moisture exchangers every 48 hours does not increase the incidence of nosocomial pneumonia. Infect Control Hosp Epidemiol 20 (1999) 347-349
-
(1999)
Infect Control Hosp Epidemiol
, vol.20
, pp. 347-349
-
-
Daumal, F.1
Colpart, E.2
Manoury, B.3
-
41
-
-
0034103469
-
Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study
-
Markowicz P., Ricard J.-D., Dreyfuss D., et al. Safety, efficacy and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med 28 (2000) 665-671
-
(2000)
Crit Care Med
, vol.28
, pp. 665-671
-
-
Markowicz, P.1
Ricard, J.-D.2
Dreyfuss, D.3
-
42
-
-
0034112596
-
Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia
-
Davis Jr. K., Evans S.L., Campbell R.S., et al. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28 (2000) 1412-1418
-
(2000)
Crit Care Med
, vol.28
, pp. 1412-1418
-
-
Davis Jr., K.1
Evans, S.L.2
Campbell, R.S.3
-
43
-
-
0034022538
-
Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation
-
Thomachot L., Boisson C., Arnaud S., et al. Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 28 (2000) 714-720
-
(2000)
Crit Care Med
, vol.28
, pp. 714-720
-
-
Thomachot, L.1
Boisson, C.2
Arnaud, S.3
-
44
-
-
0036155170
-
Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days
-
Thomachot L., Leone M., Razzouk K., et al. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 30 (2002) 232-237
-
(2002)
Crit Care Med
, vol.30
, pp. 232-237
-
-
Thomachot, L.1
Leone, M.2
Razzouk, K.3
-
45
-
-
0031733848
-
Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia
-
Thomachot L., Viviand X., Arnaud S., et al. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 114 (1998) 1383-1389
-
(1998)
Chest
, vol.114
, pp. 1383-1389
-
-
Thomachot, L.1
Viviand, X.2
Arnaud, S.3
-
46
-
-
0033030246
-
Do components of heat and moisture exchangers filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?
-
Thomachot L., Vialet R., Arnaud S., et al. Do components of heat and moisture exchangers filters affect their humidifying efficacy and the incidence of nosocomial pneumonia?. Crit Care Med 27 (1999) 923-928
-
(1999)
Crit Care Med
, vol.27
, pp. 923-928
-
-
Thomachot, L.1
Vialet, R.2
Arnaud, S.3
-
47
-
-
8444237099
-
Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers
-
Lellouche F., Taille S., Maggiore S.M., et al. Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers. Am J Respir Crit Care Med 170 (2004) 1073-1079
-
(2004)
Am J Respir Crit Care Med
, vol.170
, pp. 1073-1079
-
-
Lellouche, F.1
Taille, S.2
Maggiore, S.M.3
-
48
-
-
0037453115
-
Prevention of ventilator-associated pneumonia: an evidence-based systematic review
-
Collard H.R., Saint S., and Matthay M.A. Prevention of ventilator-associated pneumonia: an evidence-based systematic review. Ann Intern Med 138 (2003) 494-501
-
(2003)
Ann Intern Med
, vol.138
, pp. 494-501
-
-
Collard, H.R.1
Saint, S.2
Matthay, M.A.3
-
49
-
-
4043130212
-
Evidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia
-
Dodek P., Keenan S., Cook D., et al. Evidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia. Ann Intern Med 141 (2004) 305-313
-
(2004)
Ann Intern Med
, vol.141
, pp. 305-313
-
-
Dodek, P.1
Keenan, S.2
Cook, D.3
-
50
-
-
0033602066
-
The prevention of ventilator-associated pneumonia
-
Kollef M. The prevention of ventilator-associated pneumonia. N Engl J Med 340 (1999) 627-634
-
(1999)
N Engl J Med
, vol.340
, pp. 627-634
-
-
Kollef, M.1
-
51
-
-
0036902243
-
Statement of the 4th International Consensus Conference in Critical Care on ICU-Acquired Pneumonia. Chicago, Illinois, May 2002
-
Hubmayr R.D., Burchardi H., Elliot M., et al. Statement of the 4th International Consensus Conference in Critical Care on ICU-Acquired Pneumonia. Chicago, Illinois, May 2002. Intensive Care Med 28 (2002) 1521-1536
-
(2002)
Intensive Care Med
, vol.28
, pp. 1521-1536
-
-
Hubmayr, R.D.1
Burchardi, H.2
Elliot, M.3
-
52
-
-
1542394258
-
Care of the ventilator circuit and its relation to ventilator-associated pneumonia
-
Hess D.R., Kallstrom T.J., Mottram C.D., et al. Care of the ventilator circuit and its relation to ventilator-associated pneumonia. Respir Care 48 (2003) 869-879
-
(2003)
Respir Care
, vol.48
, pp. 869-879
-
-
Hess, D.R.1
Kallstrom, T.J.2
Mottram, C.D.3
-
53
-
-
1542358083
-
Prevention of ventilator-associated pneumonia
-
[authors' reply: 486-7]
-
Ricard J.D., and Dreyfuss D. Prevention of ventilator-associated pneumonia. Ann Intern Med 140 (2004) 486 [authors' reply: 486-7]
-
(2004)
Ann Intern Med
, vol.140
, pp. 486
-
-
Ricard, J.D.1
Dreyfuss, D.2
-
54
-
-
1642533565
-
Ventilatory management of acute respiratory distress syndrome: a consensus of two
-
Marini J.J., and Gattinoni L. Ventilatory management of acute respiratory distress syndrome: a consensus of two. Crit Care Med 32 (2004) 250-255
-
(2004)
Crit Care Med
, vol.32
, pp. 250-255
-
-
Marini, J.J.1
Gattinoni, L.2
-
55
-
-
0032085279
-
The role of filtration during humidification
-
Richards G. The role of filtration during humidification. Respir Care Clin N Am 4 (1998) 329-339
-
(1998)
Respir Care Clin N Am
, vol.4
, pp. 329-339
-
-
Richards, G.1
-
56
-
-
33745659319
-
-
Ricard J-D. Humidification. In: Tobin M, editor. Principles and practice of mechanical ventilation. New York: McGraw-Hill; in press.
-
-
-
|