메뉴 건너뛰기




Volumn , Issue , 2007, Pages 225-231

Whisker sensor design for three dimensional position measurement in robotic assisted beating heart surgery

Author keywords

[No Author keywords available]

Indexed keywords

CRYSTAL WHISKERS; POSITION MEASUREMENT; SENSORS; SURGERY; THREE DIMENSIONAL; TISSUE;

EID: 36348967773     PISSN: 10504729     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ROBOT.2007.363791     Document Type: Conference Paper
Times cited : (24)

References (16)
  • 2
    • 0032168333 scopus 로고    scopus 로고
    • Off-pump multi-vessel coronary bypass via sternotomy is safe and effective
    • September
    • J. D. Puskas, C. E. Wright, R. S. Ronson, W. M. Brown. J. P. Gott, and R. A. Guyton, "Off-pump multi-vessel coronary bypass via sternotomy is safe and effective." Annals of Thoracic Surgery, vol. 66, no. 3, pp. 1068-1072, September 1998.
    • (1998) Annals of Thoracic Surgery , vol.66 , Issue.3 , pp. 1068-1072
    • Puskas, J.D.1    Wright, C.E.2    Ronson, R.S.3    Brown, W.M.4    Gott, J.P.5    Guyton, R.A.6
  • 3
    • 36348966948 scopus 로고    scopus 로고
    • Personal Communication, MD, Chief of Surgery, San Francisco VA Medical Center. Professor in Residence
    • M. B. Ratcliffe, Personal Communication, MD, Chief of Surgery, San Francisco VA Medical Center. Professor in Residence.
    • Ratcliffe, M.B.1
  • 6
    • 0036057266 scopus 로고    scopus 로고
    • M. Groeger, T. Ortmaier, W. Sepp, and G. Hirzinger, Tracking local motion on the beating heart, in Proc. of the SPIE Medical Imaging Conference, 4681 of SPIE, San Diego. CA, USA, February 2002. pp. 233-241.
    • M. Groeger, T. Ortmaier, W. Sepp, and G. Hirzinger, "Tracking local motion on the beating heart," in Proc. of the SPIE Medical Imaging Conference, vol. 4681 of SPIE, San Diego. CA, USA, February 2002. pp. 233-241.
  • 11
    • 0142196055 scopus 로고    scopus 로고
    • A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation
    • October
    • P. J. Berkelman, L. L. Whitcomb, R. H. Taylor, and P. Jensen. "A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation," IEEE Transactions on Robotics and Automation, vol. 19, no. 5, pp. 917-922, October 2003.
    • (2003) IEEE Transactions on Robotics and Automation , vol.19 , Issue.5 , pp. 917-922
    • Berkelman, P.J.1    Whitcomb, L.L.2    Taylor, R.H.3    Jensen, P.4
  • 12
    • 1542346227 scopus 로고    scopus 로고
    • Profile sensing with an actuated whisker
    • February
    • G. R. Sholz and C. D. Rahn, "Profile sensing with an actuated whisker," IEEE Transactions on Robotics and Automation, vol. 20, no. 1, pp. 124-127, February 2004.
    • (2004) IEEE Transactions on Robotics and Automation , vol.20 , Issue.1 , pp. 124-127
    • Sholz, G.R.1    Rahn, C.D.2
  • 13
    • 33845646216 scopus 로고    scopus 로고
    • Predictive control algorithms using biological signals for active relative motion canceling in robotic assisted heart surgery
    • Orlando. FL, USA, May
    • O. Bebek and M. C. Cavusoglu, "Predictive control algorithms using biological signals for active relative motion canceling in robotic assisted heart surgery," in Proc. of the International Conference on Robotics and Automation (ICRA), Orlando. FL, USA, May 2006, pp. 237-244.
    • (2006) Proc. of the International Conference on Robotics and Automation (ICRA) , pp. 237-244
    • Bebek, O.1    Cavusoglu, M.C.2
  • 15
    • 85051961766 scopus 로고    scopus 로고
    • National Instruments, Tech. Rep. 078, August
    • "Strain gauge measurement - a tutorial." National Instruments, Tech. Rep. 078, August 1998.
    • (1998) Strain gauge measurement - a tutorial


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.