메뉴 건너뛰기




Volumn 16, Issue 5, 2007, Pages 459-470

Haptic feedback in a telepresence system for endoscopic heart surgery

Author keywords

[No Author keywords available]

Indexed keywords


EID: 35148828493     PISSN: 10547460     EISSN: 15313263     Source Type: Journal    
DOI: 10.1162/pres.16.5.459     Document Type: Article
Times cited : (45)

References (26)
  • 4
    • 0037268993 scopus 로고    scopus 로고
    • Robotics for telesurgery: Second generation Berkeley/UCSF laparoscopic telesurgical workstation and looking towards the future applications
    • Cavasoglu, M., Williams, W., Tendick, F., & Sastry, S. S. (2003). Robotics for telesurgery: Second generation Berkeley/UCSF laparoscopic telesurgical workstation and looking towards the future applications. Industrial Robot, Special Issues on Medical Robotics, 30(1), 22-29.
    • (2003) Industrial Robot, Special Issues on Medical Robotics , vol.30 , Issue.1 , pp. 22-29
    • Cavasoglu, M.1    Williams, W.2    Tendick, F.3    Sastry, S.S.4
  • 6
    • 0346849621 scopus 로고    scopus 로고
    • Robotic coronary artery bypass grafting (CABG)-The Leipzig experience
    • Falk, V., Jacobs, S., Gummert, J., & Walther, T. (2003). Robotic coronary artery bypass grafting (CABG)-The Leipzig experience. Surgical Clinician North America, 83(6), 1381-1386.
    • (2003) Surgical Clinician North America , vol.83 , Issue.6 , pp. 1381-1386
    • Falk, V.1    Jacobs, S.2    Gummert, J.3    Walther, T.4
  • 7
    • 0038716348 scopus 로고    scopus 로고
    • Computer-enhanced endoscopic coronary artery bypass grafting: The da Vinci experience
    • Falk, V., Jacobs, S., Gummen, J., Walther, T., & Mohr, F. W. (2003). Computer-enhanced endoscopic coronary artery bypass grafting: The da Vinci experience. Seminal Thoracic Cardiovascular Surgery, 15(2), 104-111.
    • (2003) Seminal Thoracic Cardiovascular Surgery , vol.15 , Issue.2 , pp. 104-111
    • Falk, V.1    Jacobs, S.2    Gummen, J.3    Walther, T.4    Mohr, F.W.5
  • 8
    • 0034760047 scopus 로고    scopus 로고
    • Influence of three-dimensional vision on surgical telemanipulator performance
    • Falk, V., Mintz, D., Grunenfelder, J., Fann, J. I., & Burdon, T. A. (2001). Influence of three-dimensional vision on surgical telemanipulator performance. Surgical Endoscopy, 15(11), 1282-1288.
    • (2001) Surgical Endoscopy , vol.15 , Issue.11 , pp. 1282-1288
    • Falk, V.1    Mintz, D.2    Grunenfelder, J.3    Fann, J.I.4    Burdon, T.A.5
  • 11
    • 33645748258 scopus 로고    scopus 로고
    • Sensitivity of the human visual system to amplitude, modulated light
    • Arbetslivsinstitutet, National Institute for Working Life
    • Johansson, A., & Sandstroem, M. (2003). Sensitivity of the human visual system to amplitude, modulated light. Arbetslivsrapport Nr. 2003:4. Arbetslivsinstitutet, National Institute for Working Life.
    • (2003) Arbetslivsrapport , Issue.NR. 2003 , pp. 4
    • Johansson, A.1    Sandstroem, M.2
  • 14
  • 17
    • 33947301353 scopus 로고    scopus 로고
    • Kinematics and modeling of a system for robotic surgery
    • Mayer, H., Nagy, I., & Knoll, A. (2004). Kinematics and modeling of a system for robotic surgery. On Advances in Robot Kinematics, 181-190.
    • (2004) On Advances in Robot Kinematics , pp. 181-190
    • Mayer, H.1    Nagy, I.2    Knoll, A.3
  • 23
    • 0032820913 scopus 로고    scopus 로고
    • Human factors in telesurgery: Effects of time delay and asynchrony in video and control feedback with local manipulative assistance
    • Thompson, J., Ottensmeier, M., & Sheridan, T. (1999). Human factors in telesurgery: Effects of time delay and asynchrony in video and control feedback with local manipulative assistance. Telemedical Journal, 5(2), 129-137.
    • (1999) Telemedical Journal , vol.5 , Issue.2 , pp. 129-137
    • Thompson, J.1    Ottensmeier, M.2    Sheridan, T.3
  • 26
    • 0036219039 scopus 로고    scopus 로고
    • Flimmerverschmelzungsfrequenz und zentralnervöse Aktivierung
    • Wiemeyer, J. (2002). Flimmerverschmelzungsfrequenz und zentralnervöse Aktivierung. Neurol Rehabil, 8(1), 29-34.
    • (2002) Neurol Rehabil , vol.8 , Issue.1 , pp. 29-34
    • Wiemeyer, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.