메뉴 건너뛰기




Volumn 61, Issue 3, 2007, Pages 433-446

Chained lightning, part II: Neurosurgical principles, radiosurgical technology, and the manipulation of energy beam delivery

Author keywords

Medical technology; Minimally invasive surgery; Radiation oncology; Radiation physics; Radiosurgery; Radiotherapy; Stereotactic neurosurgery

Indexed keywords

COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; GAMMA KNIFE RADIOSURGERY; GAMMA RADIATION; GEOMETRY; HUMAN; INTENSITY MODULATED RADIATION THERAPY; LINEAR ACCELERATOR; MEDICAL TECHNOLOGY; MINIMALLY INVASIVE SURGERY; NEUROSURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; ONCOLOGY; PRIORITY JOURNAL; RADIATION PHYSICS; RADIOSURGERY; REVIEW; ROBOTICS; STEREOTAXIC SURGERY; SURGICAL INSTRUMENT;

EID: 34548821253     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000290888.54578.F5     Document Type: Review
Times cited : (13)

References (107)
  • 1
    • 34548820306 scopus 로고    scopus 로고
    • Sunnyvale, CA, Accessed January 30, 2007
    • Accuray, Sunnyvale, CA. http://www.accuray.com. Accessed January 30, 2007.
    • Accuray
  • 6
    • 0020652489 scopus 로고
    • Multiple-beam stereotactic irradiation [in French]
    • Betti O, Derechinsky V: Multiple-beam stereotactic irradiation [in French]. Neurochirurgie 29:295-298, 1983.
    • (1983) Neurochirurgie , vol.29 , pp. 295-298
    • Betti, O.1    Derechinsky, V.2
  • 7
    • 0001393233 scopus 로고
    • Hyperselected encephalic irradiation with a linear accelerator
    • Betti O, Derechinsky VE: Hyperselected encephalic irradiation with a linear accelerator. Acta Neurochir Suppl (Wien) 33:385-390, 1984.
    • (1984) Acta Neurochir Suppl (Wien) , vol.33 , pp. 385-390
    • Betti, O.1    Derechinsky, V.E.2
  • 8
    • 0034433344 scopus 로고    scopus 로고
    • Aquality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape. Technical note
    • Borden JA, Mahajan A, Tsai JS: Aquality factor to compare the dosimetry of gamma knife radiosurgery and intensity-modulated radiation therapy quantitatively as a function of target volume and shape. Technical note. J Neurosurg 93 [Suppl 3]:228-232, 2000.
    • (2000) J Neurosurg , vol.93 , Issue.SUPPL. 3 , pp. 228-232
    • Borden, J.A.1    Mahajan, A.2    Tsai, J.S.3
  • 9
    • 33745488460 scopus 로고    scopus 로고
    • IMRT: Areview and preview
    • Bortfeld T: IMRT: Areview and preview. Phys Med Biol 51:R363-R379, 2006.
    • (2006) Phys Med Biol , vol.51
    • Bortfeld, T.1
  • 10
    • 0028009079 scopus 로고
    • Static field conformal stereotactic radiosurgery: Physical techniques
    • Bourland JD, McCollough KP: Static field conformal stereotactic radiosurgery: Physical techniques. Int J Radiat Oncol Biol Phys 28:471-479, 1994.
    • (1994) Int J Radiat Oncol Biol Phys , vol.28 , pp. 471-479
    • Bourland, J.D.1    McCollough, K.P.2
  • 11
    • 34548819175 scopus 로고    scopus 로고
    • Accessed April 14
    • BrainLAB, Heimstetten, Germany. http://www.brainlab.com. Accessed April 14, 2007.
    • (2007) Germany
    • BrainLAB1    Heimstetten2
  • 12
    • 0025998559 scopus 로고
    • Fractionated regimens for stereotactic radiotherapy of recurrent tumors in the brain
    • Brenner DJ, Martel MK, Hall EJ: Fractionated regimens for stereotactic radiotherapy of recurrent tumors in the brain. Int J Radiat Oncol Biol Phys 21:819-824, 1991.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 819-824
    • Brenner, D.J.1    Martel, M.K.2    Hall, E.J.3
  • 13
    • 0018751133 scopus 로고
    • A computerized tomography-computer graphics approach to stereotaxic localization
    • Brown RA: A computerized tomography-computer graphics approach to stereotaxic localization. J Neurosurg 50:715-720, 1979.
    • (1979) J Neurosurg , vol.50 , pp. 715-720
    • Brown, R.A.1
  • 14
    • 0018964342 scopus 로고    scopus 로고
    • Brown RA, Roberts TS, Osborn AG: Stereotaxic frame and computer software for CT-directed neurosurgical localization. Invest Radiol 15:308-312, 1980
    • Brown RA, Roberts TS, Osborn AG: Stereotaxic frame and computer software for CT-directed neurosurgical localization. Invest Radiol 15:308-312, 1980.
  • 16
  • 17
    • 0037234447 scopus 로고    scopus 로고
    • An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system
    • Chang SD, Main W, Martin DP, Gibbs IC, Heilbrun MP: An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system. Neurosurgery 52:140-147, 2003.
    • (2003) Neurosurgery , vol.52 , pp. 140-147
    • Chang, S.D.1    Main, W.2    Martin, D.P.3    Gibbs, I.C.4    Heilbrun, M.P.5
  • 18
    • 0004034852 scopus 로고    scopus 로고
    • Principles of stereotactic neurosurgery
    • Youmans JR ed, Philadelphia, W.B. Saunders
    • Chin LS, Levy ML, Apuzzo MLJ: Principles of stereotactic neurosurgery, in Youmans JR (ed): Neurological Surgery. Philadelphia, W.B. Saunders, 1996, pp 767-785.
    • (1996) Neurological Surgery , pp. 767-785
    • Chin, L.S.1    Levy, M.L.2    Apuzzo, M.L.J.3
  • 22
    • 0032951630 scopus 로고    scopus 로고
    • Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery
    • Cosgrove VP, Jahn U, Pfaender M, Bauer S, Budach V, Wurm RE: Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery. Radiother Oncol 50:325-336, 1999.
    • (1999) Radiother Oncol , vol.50 , pp. 325-336
    • Cosgrove, V.P.1    Jahn, U.2    Pfaender, M.3    Bauer, S.4    Budach, V.5    Wurm, R.E.6
  • 24
    • 17444393557 scopus 로고    scopus 로고
    • Linac radiosurgery as a tool in neurosurgery
    • Deinsberger R, Tidstrand J: Linac radiosurgery as a tool in neurosurgery. Neurosurg Rev 28:79-88, 2005.
    • (2005) Neurosurg Rev , vol.28 , pp. 79-88
    • Deinsberger, R.1    Tidstrand, J.2
  • 25
    • 0025990959 scopus 로고
    • Fractionated radiotherapy of small inoperable lesions of the brain using a non-invasive stereotactic frame
    • Delannes M, Daly MJ, Bonnet J, Sabatier J, Tremoulet M: Fractionated radiotherapy of small inoperable lesions of the brain using a non-invasive stereotactic frame. Int J Radiat Oncol Biol Phys 21:749-755, 1991.
    • (1991) Int J Radiat Oncol Biol Phys , vol.21 , pp. 749-755
    • Delannes, M.1    Daly, M.J.2    Bonnet, J.3    Sabatier, J.4    Tremoulet, M.5
  • 26
    • 33750361470 scopus 로고    scopus 로고
    • Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system
    • Ding M, Newman F, Kavanagh BD, Stuhr K, Johnson TK, Gaspar LE: Comparative dosimetric study of three-dimensional conformal, dynamic conformal arc, and intensity-modulated radiotherapy for brain tumor treatment using Novalis system. Int J Radiat Oncol Biol Phys 66:S82-S86, 2006.
    • (2006) Int J Radiat Oncol Biol Phys , vol.66
    • Ding, M.1    Newman, F.2    Kavanagh, B.D.3    Stuhr, K.4    Johnson, T.K.5    Gaspar, L.E.6
  • 27
    • 33747048170 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs issues and how to detect them
    • Dobler B, Lorenz F, Wertz H, Polednik M, Wolff D, Steil V, Lohr F, Wenz F: Intensity-modulated radiation therapy (IMRT) with different combinations of treatment-planning systems and linacs issues and how to detect them. Strahlenther Onkol 182:481-488, 2006.
    • (2006) Strahlenther Onkol , vol.182 , pp. 481-488
    • Dobler, B.1    Lorenz, F.2    Wertz, H.3    Polednik, M.4    Wolff, D.5    Steil, V.6    Lohr, F.7    Wenz, F.8
  • 28
    • 34548861341 scopus 로고    scopus 로고
    • Accessed January 20
    • Elekta, Stockholm, Sweden. http://www.elekta.com/ healthcare_international_treatment_statistics.php. Accessed January 20, 2007.
    • (2007) Sweden
    • Elekta, S.1
  • 31
    • 0024451171 scopus 로고
    • The University of Florida radiosurgery system
    • Friedman WA, Bova FJ: The University of Florida radiosurgery system. Surg Neurol 32:334-342, 1989.
    • (1989) Surg Neurol , vol.32 , pp. 334-342
    • Friedman, W.A.1    Bova, F.J.2
  • 34
    • 0036498874 scopus 로고    scopus 로고
    • Risk analysis of Leksell Gamma Knife Model C with automatic positioning system
    • Goetsch SJ: Risk analysis of Leksell Gamma Knife Model C with automatic positioning system. Int J Radiat Oncol Biol Phys 52:869-877, 2002.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 869-877
    • Goetsch, S.J.1
  • 36
    • 0001816270 scopus 로고
    • The use of standard isodose distributions with high energy radiation beams - The accuracy of a compensator technique in correcting for body contours
    • Hall EJ, Oliver R: The use of standard isodose distributions with high energy radiation beams - The accuracy of a compensator technique in correcting for body contours. Br J Radiol 34:43, 1961.
    • (1961) Br J Radiol , vol.34 , pp. 43
    • Hall, E.J.1    Oliver, R.2
  • 37
    • 0028864576 scopus 로고
    • Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy
    • Hamilton RJ, Kuchnir FT, Sweeney P, Rubin SJ, Dujovny M, Pelizzari CA, Chen GT: Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 33:1221-1228, 1995.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 1221-1228
    • Hamilton, R.J.1    Kuchnir, F.T.2    Sweeney, P.3    Rubin, S.J.4    Dujovny, M.5    Pelizzari, C.A.6    Chen, G.T.7
  • 38
    • 0025134050 scopus 로고
    • A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator
    • Hariz MI, Henriksson R, Lofroth PO, Laitinen LV, Saterborg NE: A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear accelerator. Radiother Oncol 17:57-72, 1990.
    • (1990) Radiother Oncol , vol.17 , pp. 57-72
    • Hariz, M.I.1    Henriksson, R.2    Lofroth, P.O.3    Laitinen, L.V.4    Saterborg, N.E.5
  • 40
    • 0020515336 scopus 로고
    • Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system
    • Heilbrun MP, Roberts TS, Apuzzo ML, Wells TH Jr, Sabshin JK: Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system. J Neurosurg 59:217-222, 1983.
    • (1983) J Neurosurg , vol.59 , pp. 217-222
    • Heilbrun, M.P.1    Roberts, T.S.2    Apuzzo, M.L.3    Wells Jr, T.H.4    Sabshin, J.K.5
  • 41
    • 33846982562 scopus 로고    scopus 로고
    • Ho AK, Fu D, Cotrutz C, Hancock SL, Chang SD, Gibbs IC, Maurer CR Jr, Adler JR Jr: A study of the accuracy of Cyberknife spinal radiosurgery using skeletal structure tracking. Neurosurgery 60 [Suppl 1]:ONS147-ONS156, 2007.
    • Ho AK, Fu D, Cotrutz C, Hancock SL, Chang SD, Gibbs IC, Maurer CR Jr, Adler JR Jr: A study of the accuracy of Cyberknife spinal radiosurgery using skeletal structure tracking. Neurosurgery 60 [Suppl 1]:ONS147-ONS156, 2007.
  • 43
    • 0001872573 scopus 로고
    • The structure and function of the cerebellum examined by a new method
    • Horsley V, Clarke RH: The structure and function of the cerebellum examined by a new method. Brain 31:45-124, 1908.
    • (1908) Brain , vol.31 , pp. 45-124
    • Horsley, V.1    Clarke, R.H.2
  • 44
    • 0021811307 scopus 로고
    • Stereotaxic radiotherapy technique for small intracranial lesions
    • Houdek PV, Fayos JV, Van Buren JM, Ginsberg MS: Stereotaxic radiotherapy technique for small intracranial lesions. Med Phys 12:469-472, 1985.
    • (1985) Med Phys , vol.12 , pp. 469-472
    • Houdek, P.V.1    Fayos, J.V.2    Van Buren, J.M.3    Ginsberg, M.S.4
  • 46
    • 0035889335 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: Current status and issues of interest
    • Intensity Modulated Radiation Therapy Collaborative Working Group
    • Intensity Modulated Radiation Therapy Collaborative Working Group: Intensity-modulated radiotherapy: Current status and issues of interest. Int J Radiat Oncol Biol Phys 51:880-914, 2001.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 880-914
  • 47
    • 0014819273 scopus 로고
    • The construction of compensators for cobalt teletherapy
    • Khan FM, Moore VC, Burns DJ: The construction of compensators for cobalt teletherapy. Radiology 96:187-192, 1970.
    • (1970) Radiology , vol.96 , pp. 187-192
    • Khan, F.M.1    Moore, V.C.2    Burns, D.J.3
  • 48
    • 0028896426 scopus 로고
    • Radiobiology of radiosurgery for refractory anxiety disorders
    • Kihlstrom L, Guo WY, Lindquist C, Mindus P: Radiobiology of radiosurgery for refractory anxiety disorders. Neurosurgery 36:294-302, 1995.
    • (1995) Neurosurgery , vol.36 , pp. 294-302
    • Kihlstrom, L.1    Guo, W.Y.2    Lindquist, C.3    Mindus, P.4
  • 50
    • 0031726142 scopus 로고    scopus 로고
    • The costs of radiosurgical treatment: Comparison between gamma knife and linear accelerator
    • Konigsmaier H, de Pauli-Ferch B, Hackl A, Pendl G: The costs of radiosurgical treatment: Comparison between gamma knife and linear accelerator. Acta Neurochir (Wien) 140:1101-1111, 1998.
    • (1998) Acta Neurochir (Wien) , vol.140 , pp. 1101-1111
    • Konigsmaier, H.1    de Pauli-Ferch, B.2    Hackl, A.3    Pendl, G.4
  • 51
    • 3042819108 scopus 로고    scopus 로고
    • The Leksell Gamma Knife model U versus model C: A quantitative comparison of radiosurgical treatment parameters
    • Kuo JS, Yu C, Giannotta SL, Petrovich Z, Apuzzo ML: The Leksell Gamma Knife model U versus model C: A quantitative comparison of radiosurgical treatment parameters. Neurosurgery 55:168-173, 2004.
    • (2004) Neurosurgery , vol.55 , pp. 168-173
    • Kuo, J.S.1    Yu, C.2    Giannotta, S.L.3    Petrovich, Z.4    Apuzzo, M.L.5
  • 52
    • 0242497721 scopus 로고    scopus 로고
    • The Cyberknife stereotactic radiosurgery system: Description, installation, and an initial evaluation of use and functionality
    • Kuo JS, Yu C, Petrovich Z, Apuzzo ML: The Cyberknife stereotactic radiosurgery system: Description, installation, and an initial evaluation of use and functionality. Neurosurgery 53:1235-1239, 2003.
    • (2003) Neurosurgery , vol.53 , pp. 1235-1239
    • Kuo, J.S.1    Yu, C.2    Petrovich, Z.3    Apuzzo, M.L.4
  • 55
    • 33646117289 scopus 로고    scopus 로고
    • Dynamic collimator optimization compared with fixed collimator angle in arc-based stereotactic radiotherapy: A dosimetric analysis
    • Lee CM, Watson GA, Leavitt DD: Dynamic collimator optimization compared with fixed collimator angle in arc-based stereotactic radiotherapy: A dosimetric analysis. Neurosurg Focus 19:1-5, 2005.
    • (2005) Neurosurg Focus , vol.19 , pp. 1-5
    • Lee, C.M.1    Watson, G.A.2    Leavitt, D.D.3
  • 56
    • 76949138594 scopus 로고
    • The stereotaxic method and radiosurgery of the brain
    • Leksell L: The stereotaxic method and radiosurgery of the brain. Acta Chir Scand 102:316-319, 1951.
    • (1951) Acta Chir Scand , vol.102 , pp. 316-319
    • Leksell, L.1
  • 57
    • 0015184952 scopus 로고
    • Stereotaxic radiosurgery in trigeminal neuralgia
    • Leksell L: Stereotaxic radiosurgery in trigeminal neuralgia. Acta Chir Scand 137:311-314, 1971.
    • (1971) Acta Chir Scand , vol.137 , pp. 311-314
    • Leksell, L.1
  • 59
    • 22544436952 scopus 로고    scopus 로고
    • American Association of Physicists in Medicine Radiation Therapy Committee: Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68
    • Lightstone AW, Benedict SH, Bova FJ, Solberg TD, Stern RL; American Association of Physicists in Medicine Radiation Therapy Committee: Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68. Med Phys 32:2380-2398, 2005.
    • (2005) Med Phys , vol.32 , pp. 2380-2398
    • Lightstone, A.W.1    Benedict, S.H.2    Bova, F.J.3    Solberg, T.D.4    Stern, R.L.5
  • 60
    • 0024492354 scopus 로고
    • Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife
    • Lunsford LD, Flickinger J, Lindner G, Maitz A: Stereotactic radiosurgery of the brain using the first United States 201 cobalt-60 source gamma knife. Neurosurgery 24:151-159, 1989.
    • (1989) Neurosurgery , vol.24 , pp. 151-159
    • Lunsford, L.D.1    Flickinger, J.2    Lindner, G.3    Maitz, A.4
  • 61
    • 0343777880 scopus 로고
    • A method to produce fixed shaped fields for stereotactic radiosurgery
    • Lutz W, Kimball W: A method to produce fixed shaped fields for stereotactic radiosurgery. Med Phys 21:890, 1994.
    • (1994) Med Phys , vol.21 , pp. 890
    • Lutz, W.1    Kimball, W.2
  • 62
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W, Winston KR, Maleki N: A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 14:373-381, 1988.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 63
    • 0003665421 scopus 로고
    • Radiation physics for radiosurgery
    • Alexander E 3rd, Loeffler JS, Lunsford LD eds, New York, McGraw-Hill
    • Lutz W: Radiation physics for radiosurgery, in Alexander E 3rd, Loeffler JS, Lunsford LD (eds): Stereotactic Radiosurgery. New York, McGraw-Hill, 1993, pp 7-15.
    • (1993) Stereotactic Radiosurgery , pp. 7-15
    • Lutz, W.1
  • 64
    • 0028813355 scopus 로고
    • Single isocenter treatment planning for homogeneous dose delivery to nonspherical targets in multiarc linear accelerator radiosurgery
    • Luxton G, Jozsef G: Single isocenter treatment planning for homogeneous dose delivery to nonspherical targets in multiarc linear accelerator radiosurgery. Int J Radiat Oncol Biol Phys 31:635-643, 1995.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , pp. 635-643
    • Luxton, G.1    Jozsef, G.2
  • 65
    • 0027471614 scopus 로고
    • Stereotactic radiosurgery: Principles and comparison of treatment methods
    • Luxton G, Petrovich Z, Jozsef G, Nedzi LA, Apuzzo ML: Stereotactic radiosurgery: Principles and comparison of treatment methods. Neurosurgery 32:241-259, 1993.
    • (1993) Neurosurgery , vol.32 , pp. 241-259
    • Luxton, G.1    Petrovich, Z.2    Jozsef, G.3    Nedzi, L.A.4    Apuzzo, M.L.5
  • 68
    • 0030442722 scopus 로고    scopus 로고
    • The accuracy of dose localization for an image-guided frameless radiosurgery system
    • Murphy MJ, Cox RS: The accuracy of dose localization for an image-guided frameless radiosurgery system. Med Phys 23:2043-2049, 1996.
    • (1996) Med Phys , vol.23 , pp. 2043-2049
    • Murphy, M.J.1    Cox, R.S.2
  • 70
    • 33748508642 scopus 로고    scopus 로고
    • From selective thalamotomy with microrecording to gamma thalamotomy for movement disorders
    • Ohye C: From selective thalamotomy with microrecording to gamma thalamotomy for movement disorders. Stereotact Funct Neurosurg 84:155-161, 2006.
    • (2006) Stereotact Funct Neurosurg , vol.84 , pp. 155-161
    • Ohye, C.1
  • 71
    • 13744257745 scopus 로고    scopus 로고
    • Gamma knife thalamotomy for movement disorders: Evaluation of the thalamic lesion and clinical results
    • Ohye C, Shibazaki T, Sato S: Gamma knife thalamotomy for movement disorders: Evaluation of the thalamic lesion and clinical results. J Neurosurg 102 [Suppl]:234-240, 2005.
    • (2005) J Neurosurg , vol.102 , Issue.SUPPL. , pp. 234-240
    • Ohye, C.1    Shibazaki, T.2    Sato, S.3
  • 72
    • 0345257803 scopus 로고    scopus 로고
    • Stereotactic radiosurgery XVI: Isodosimetric comparison of photon stereotactic radiosurgery techniques (gamma knife vs. micromultileaf collimator linear accelerator) for acoustic neuroma - and potential clinical importance
    • Perks JR, St. George EJ, El Hamri K, Blackburn P, Plowman PN: Stereotactic radiosurgery XVI: Isodosimetric comparison of photon stereotactic radiosurgery techniques (gamma knife vs. micromultileaf collimator linear accelerator) for acoustic neuroma - and potential clinical importance. Int J Radiat Oncol Biol Phys 57:1450-1459, 2003.
    • (2003) Int J Radiat Oncol Biol Phys , vol.57 , pp. 1450-1459
    • Perks, J.R.1    St. George, E.J.2    El Hamri, K.3    Blackburn, P.4    Plowman, P.N.5
  • 73
    • 0023623538 scopus 로고
    • Dose distributions in dynamic stereotactic radiosurgery
    • Pike B, Podgorsak EB, Peters TM, Pla C: Dose distributions in dynamic stereotactic radiosurgery. Med Phys 14:780-789, 1987.
    • (1987) Med Phys , vol.14 , pp. 780-789
    • Pike, B.1    Podgorsak, E.B.2    Peters, T.M.3    Pla, C.4
  • 79
    • 33744957826 scopus 로고    scopus 로고
    • Radiosurgery and whole-brain radiation therapy for brain metastases: Either or both as the optimal treatment
    • Raizer J: Radiosurgery and whole-brain radiation therapy for brain metastases: Either or both as the optimal treatment. JAMA 295:2535-2536, 2006.
    • (2006) JAMA , vol.295 , pp. 2535-2536
    • Raizer, J.1
  • 81
    • 19444377679 scopus 로고    scopus 로고
    • The evolving role of stereotactic radiosurgery and stereotactic radiation therapy for patients with spine tumors
    • Rock JP, Ryu S, Yin FF, Schreiber F, Abdulhak M: The evolving role of stereotactic radiosurgery and stereotactic radiation therapy for patients with spine tumors. J Neurooncol 69:319-334, 2004.
    • (2004) J Neurooncol , vol.69 , pp. 319-334
    • Rock, J.P.1    Ryu, S.2    Yin, F.F.3    Schreiber, F.4    Abdulhak, M.5
  • 83
    • 0013684305 scopus 로고    scopus 로고
    • Update of Radiation Therapy Oncology Group (RTOG) protocol (9005): Single dose radiosurgical treatment of recurrent brain tumors (abstract)
    • Shaw E, Scott C, Souhami L, Dinapoli R, Kline R, Loeffler J, Farnan N: Update of Radiation Therapy Oncology Group (RTOG) protocol (9005): Single dose radiosurgical treatment of recurrent brain tumors (abstract). Int J Radiat Oncol Biol Phys 42 [Suppl 1]:196, 1998.
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , Issue.SUPPL. 1 , pp. 196
    • Shaw, E.1    Scott, C.2    Souhami, L.3    Dinapoli, R.4    Kline, R.5    Loeffler, J.6    Farnan, N.7
  • 84
    • 30144441006 scopus 로고    scopus 로고
    • Prospective staged volume radiosurgery for large arteriovenous malformations: Indications and outcomes in otherwise untreatable patients
    • Sirin S, Kondziolka D, Niranjan A, Flickinger JC, Maitz AH, Lunsford LD: Prospective staged volume radiosurgery for large arteriovenous malformations: Indications and outcomes in otherwise untreatable patients. Neurosurgery 58:17-27, 2006.
    • (2006) Neurosurgery , vol.58 , pp. 17-27
    • Sirin, S.1    Kondziolka, D.2    Niranjan, A.3    Flickinger, J.C.4    Maitz, A.H.5    Lunsford, L.D.6
  • 85
    • 0036894622 scopus 로고    scopus 로고
    • The commissioning and quality assurance of the automatic positioning system on the Leksell gamma knife
    • Soanes T, Hampshire A, Vaughan P, Brownett C, Rowe J, Radatz M, Kemeny A, Walton L: The commissioning and quality assurance of the automatic positioning system on the Leksell gamma knife. J Neurosurg 97 [Suppl 5]:574-578, 2002.
    • (2002) J Neurosurg , vol.97 , Issue.SUPPL. 5 , pp. 574-578
    • Soanes, T.1    Hampshire, A.2    Vaughan, P.3    Brownett, C.4    Rowe, J.5    Radatz, M.6    Kemeny, A.7    Walton, L.8
  • 86
    • 0035312629 scopus 로고    scopus 로고
    • Dynamic arc radiosurgery field shaping: A comparison with static field conformal and noncoplanar circular arcs
    • Solberg TD, Boedeker KL, Fogg R, Selch MT, DeSalles AA: Dynamic arc radiosurgery field shaping: A comparison with static field conformal and noncoplanar circular arcs. Int J Radiat Oncol Biol Phys 49:1481-1491, 2001.
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 1481-1491
    • Solberg, T.D.1    Boedeker, K.L.2    Fogg, R.3    Selch, M.T.4    DeSalles, A.A.5
  • 87
    • 76549253811 scopus 로고
    • Pallido-thalamotomy in chorea
    • Spiegel EA, Wycis HT: Pallido-thalamotomy in chorea. Arch Neurol 64:495-496, 1950.
    • (1950) Arch Neurol , vol.64 , pp. 495-496
    • Spiegel, E.A.1    Wycis, H.T.2
  • 88
    • 0038530937 scopus 로고
    • Mesencephalotomy in the treatment of 'intractable' facial pain
    • Spiegel EA, Wycis HT: Mesencephalotomy in the treatment of 'intractable' facial pain. Arch Neurol 69:1-13, 1953.
    • (1953) Arch Neurol , vol.69 , pp. 1-13
    • Spiegel, E.A.1    Wycis, H.T.2
  • 89
    • 0004287934 scopus 로고
    • Pallidotomy and pallidoamygdalotomy in certain types of convulsive disorders
    • Spiegel EA, Wycis HT: Pallidotomy and pallidoamygdalotomy in certain types of convulsive disorders. Arch Neurol 80:714-728, 1958.
    • (1958) Arch Neurol , vol.80 , pp. 714-728
    • Spiegel, E.A.1    Wycis, H.T.2
  • 90
    • 37049229536 scopus 로고
    • Stereotaxic apparatus for operations on the human brain
    • Spiegel EA, Wycis HT, Marks M, Lee AJ: Stereotaxic apparatus for operations on the human brain. Science 106:349-350, 1947.
    • (1947) Science , vol.106 , pp. 349-350
    • Spiegel, E.A.1    Wycis, H.T.2    Marks, M.3    Lee, A.J.4
  • 91
    • 22244491020 scopus 로고    scopus 로고
    • A geometrically based method of step and shoot stereotactic radiosurgery with a miniature multileaf collimator
    • St. John TJ, Wagner TH, Bova FJ, Friedman WA, Meeks SL: A geometrically based method of step and shoot stereotactic radiosurgery with a miniature multileaf collimator. Phys Med Biol 50:3263-3276, 2005.
    • (2005) Phys Med Biol , vol.50 , pp. 3263-3276
    • St. John, T.J.1    Wagner, T.H.2    Bova, F.J.3    Friedman, W.A.4    Meeks, S.L.5
  • 92
    • 0002319554 scopus 로고
    • Conformation radiotherapy - Rotation techniques as applied to radiography and radiotherapy of cancer
    • Takahaski S: Conformation radiotherapy - Rotation techniques as applied to radiography and radiotherapy of cancer. Acta Radiol Diagn (Stockh) 242 [Suppl]:1-142, 1965.
    • (1965) Acta Radiol Diagn (Stockh) , vol.242 , Issue.SUPPL. , pp. 1-142
    • Takahaski, S.1
  • 93
    • 0025727878 scopus 로고    scopus 로고
    • Thornton AF Jr, Ten Haken RK, Gerhardsson A, Correll M: Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI and PET imaging. Radiother Oncol 20:224-228, 1991.
    • Thornton AF Jr, Ten Haken RK, Gerhardsson A, Correll M: Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI and PET imaging. Radiother Oncol 20:224-228, 1991.
  • 94
    • 33745504032 scopus 로고    scopus 로고
    • Back to the future: The history and development of the clinical linear accelerator
    • Thwaites DI, Tuohy JB: Back to the future: The history and development of the clinical linear accelerator. Phys Med Biol 51:R343-R362, 2006.
    • (2006) Phys Med Biol , vol.51
    • Thwaites, D.I.1    Tuohy, J.B.2
  • 95
    • 0033556637 scopus 로고    scopus 로고
    • A non invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease
    • Tsai JS, Engler MJ, Ling MN, Wu JK, Kramer B, Dipetrillo T, Wazer DE: A non invasive immobilization system and related quality assurance for dynamic intensity modulated radiation therapy of intracranial and head and neck disease. Int J Radiat Oncol Biol Phys 43:455-467, 1999.
    • (1999) Int J Radiat Oncol Biol Phys , vol.43 , pp. 455-467
    • Tsai, J.S.1    Engler, M.J.2    Ling, M.N.3    Wu, J.K.4    Kramer, B.5    Dipetrillo, T.6    Wazer, D.E.7
  • 96
    • 34548838687 scopus 로고    scopus 로고
    • Palo Alto, CA, Accessed April 14, 2007
    • Varian, Palo Alto, CA. http://www.varian.com. Accessed April 14, 2007.
    • Varian
  • 97
    • 0032518343 scopus 로고    scopus 로고
    • Comparison of radiosurgery treatment modalities based on physical dose distributions
    • Verhey LJ, Smith V, Serago CF: Comparison of radiosurgery treatment modalities based on physical dose distributions. Int J Radiat Oncol Biol Phys 40:497-505, 1998.
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 497-505
    • Verhey, L.J.1    Smith, V.2    Serago, C.F.3
  • 98
    • 0030752676 scopus 로고    scopus 로고
    • CT simulation in stereotactic brain radiotherapy-analysis of isocenter reproducibility with mask fixation
    • Willner J, Flentje M, Bratengeier K: CT simulation in stereotactic brain radiotherapy-analysis of isocenter reproducibility with mask fixation. Radiother Oncol 45:83-88, 1997.
    • (1997) Radiother Oncol , vol.45 , pp. 83-88
    • Willner, J.1    Flentje, M.2    Bratengeier, K.3
  • 99
    • 0023939215 scopus 로고
    • Linear accelerator as a neurosurgical tool for stereotactic radiosurgery
    • Winston KR, Lutz W: Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. Neurosurgery 22:454-463, 1988.
    • (1988) Neurosurgery , vol.22 , pp. 454-463
    • Winston, K.R.1    Lutz, W.2
  • 101
    • 0347625753 scopus 로고    scopus 로고
    • A phantom study on the positioning accuracy of the Novalis Body system
    • Yan H, Yin FF, Kim JH: A phantom study on the positioning accuracy of the Novalis Body system. Med Phys 30: 3052-3060, 2003
    • (2003) Med Phys , vol.30 , pp. 3052-3060
    • Yan, H.1    Yin, F.F.2    Kim, J.H.3
  • 103
    • 0242414613 scopus 로고    scopus 로고
    • Dosimetric comparison of Cyberknife with other radiosurgical modalities for an ellipsoidal target
    • Yu C, Jozsef G, Apuzzo ML, Petrovich Z: Dosimetric comparison of Cyberknife with other radiosurgical modalities for an ellipsoidal target. Neurosurgery 53:1155-1163, 2003.
    • (2003) Neurosurgery , vol.53 , pp. 1155-1163
    • Yu, C.1    Jozsef, G.2    Apuzzo, M.L.3    Petrovich, Z.4
  • 104
    • 0347601908 scopus 로고    scopus 로고
    • Measurements of the relative output factors for CyberKnife collimators
    • Yu C, Jozsef G, Apuzzo ML, Petrovich Z: Measurements of the relative output factors for CyberKnife collimators. Neurosurgery 54:157-162, 2004.
    • (2004) Neurosurgery , vol.54 , pp. 157-162
    • Yu, C.1    Jozsef, G.2    Apuzzo, M.L.3    Petrovich, Z.4
  • 105
    • 8744294785 scopus 로고    scopus 로고
    • An anthropomorphic phantom study of the accuracy of Cyberknife spinal radiosurgery
    • Yu C, Main W, Taylor D, Kuduvalli G, Apuzzo ML, Adler JR Jr: An anthropomorphic phantom study of the accuracy of Cyberknife spinal radiosurgery. Neurosurgery 55:1138-1149, 2004.
    • (2004) Neurosurgery , vol.55 , pp. 1138-1149
    • Yu, C.1    Main, W.2    Taylor, D.3    Kuduvalli, G.4    Apuzzo, M.L.5    Adler Jr, J.R.6
  • 106
    • 0032863004 scopus 로고    scopus 로고
    • Dosimetric comparison of three photon radiosurgery techniques for an elongated ellipsoid target
    • Yu C, Luxton G, Jozsef G, Apuzzo ML, Petrovich Z: Dosimetric comparison of three photon radiosurgery techniques for an elongated ellipsoid target. Int J Radiat Oncol Biol Phys 45:817-826, 1999.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 817-826
    • Yu, C.1    Luxton, G.2    Jozsef, G.3    Apuzzo, M.L.4    Petrovich, Z.5
  • 107
    • 33644503864 scopus 로고    scopus 로고
    • Stereotactic linac-based radiosurgery in the treatment of cerebral arteriovenous malformations located deep, involving corpus callosum, motor cortex, or brainstem
    • Zabel-du Bois A, Milker-Zabel S, Huber P, Schlegel W, Debus J: Stereotactic linac-based radiosurgery in the treatment of cerebral arteriovenous malformations located deep, involving corpus callosum, motor cortex, or brainstem. Int J Radiat Oncol Biol Phys 64:1044-1048, 2006.
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1044-1048
    • Zabel-du Bois, A.1    Milker-Zabel, S.2    Huber, P.3    Schlegel, W.4    Debus, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.