메뉴 건너뛰기




Volumn 30, Issue 12, 2003, Pages 3052-3060

A phantom study on the positioning accuracy of the Novalis Body system

Author keywords

Extracranial radiosurgery; Image guided therapy; Novalis Body system; Patient positioning

Indexed keywords

COMPUTERIZED TOMOGRAPHY; ERRORS; RADIOTHERAPY; VIDEO CAMERAS; WATER TANKS;

EID: 0347625753     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1626122     Document Type: Article
Times cited : (96)

References (13)
  • 2
    • 0035889332 scopus 로고    scopus 로고
    • Initial clinical experience with frameless stereotactic radiosurgery: Analysis of accuracy and feasibility
    • T. C. Ryken et al., "Initial clinical experience with frameless stereotactic radiosurgery: analysis of accuracy and feasibility," Int. J. Radiat. Oncol., Biol., Phys. 51, 1152-1158 (2001).
    • (2001) Int. J. Radiat. Oncol., Biol., Phys. , vol.51 , pp. 1152-1158
    • Ryken, T.C.1
  • 3
    • 0033971984 scopus 로고    scopus 로고
    • Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer
    • J. Lattanzi, S. McNeeley, A. Hanlon, T. E. Schultheiss, and G. E. Hanks, "Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer," Urology 55, 73-78 (2000).
    • (2000) Urology , vol.55 , pp. 73-78
    • Lattanzi, J.1    McNeeley, S.2    Hanlon, A.3    Schultheiss, T.E.4    Hanks, G.E.5
  • 4
    • 0000009973 scopus 로고    scopus 로고
    • Three-dimensional ultrasound image guidance for high precision extracranial radiotherapy
    • L. G. Bouchet, S. L. Meeks, F. J. Bova, J. M. Buatti, and W. A. Friedman, "Three-dimensional ultrasound image guidance for high precision extracranial radiotherapy," Radiosurgery 4, 262-278 (2002).
    • (2002) Radiosurgery , vol.4 , pp. 262-278
    • Bouchet, L.G.1    Meeks, S.L.2    Bova, F.J.3    Buatti, J.M.4    Friedman, W.A.5
  • 6
    • 0036703725 scopus 로고    scopus 로고
    • Commissioning and quality assurance of an optically guided three-dimensional ultrasound target localization system for radiotherapy
    • W. A. Tome, S. L. Meeks, J. N. P. Orton, L. G. Bouchet, and F. J. Bova, "Commissioning and quality assurance of an optically guided three-dimensional ultrasound target localization system for radiotherapy," Med. Phys. 29, 1781-1788 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1781-1788
    • Tome, W.A.1    Meeks, S.L.2    Orton, J.N.P.3    Bouchet, L.G.4    Bova, F.J.5
  • 9
    • 0036127009 scopus 로고    scopus 로고
    • Fiducial-based targeting accuracy for external-beam radiotherapy
    • M. J. Murphy, "Fiducial-based targeting accuracy for external-beam radiotherapy," Med. Phys. 29, 334-344 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 334-344
    • Murphy, M.J.1
  • 10
    • 12244279063 scopus 로고    scopus 로고
    • A technique of intensity-modulated radiosurgery (IMRS) for spinal tumors
    • F. F. Yin et al., "A technique of intensity-modulated radiosurgery (IMRS) for spinal tumors," Med. Phys. 29, 2815-2822 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2815-2822
    • Yin, F.F.1
  • 11
    • 0036834636 scopus 로고    scopus 로고
    • Clinical use of stereoscopic x-ray positioning of patients treated with conformal radiotherapy for prostate cancer
    • G. Soete et al., "Clinical use of stereoscopic x-ray positioning of patients treated with conformal radiotherapy for prostate cancer," Int. J. Radiat. Oncol., Biol., Phys. 54, 948-952 (2002).
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.54 , pp. 948-952
    • Soete, G.1
  • 13
    • 0030088712 scopus 로고    scopus 로고
    • Multimodal volume registration by maximization of mutual information
    • W. M. Wells, P. Viola, H. Atsumi, S. Nakajima, and R. Kikinis, "Multimodal volume registration by maximization of mutual information," Med. Image Anal 1, 35-51 (1996).
    • (1996) Med. Image Anal. , vol.1 , pp. 35-51
    • Wells, W.M.1    Viola, P.2    Atsumi, H.3    Nakajima, S.4    Kikinis, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.