메뉴 건너뛰기




Volumn 44, Issue 6, 1999, Pages 1299-1307

Image-guided robotic radiosurgery

Author keywords

Image guided; Radiosurgery; Stereotactic

Indexed keywords

ACCURACY; ARTICLE; CALIBRATION; CAMERA; COMPUTER; COMPUTER ASSISTED TOMOGRAPHY; ERROR; HUMAN; IMAGING SYSTEM; LINEAR ACCELERATOR; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT POSITIONING; PRIORITY JOURNAL; RADIOSURGERY; ROBOTICS; STEREOTAXIC SURGERY; TREATMENT PLANNING;

EID: 0033010153     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006123-199906000-00079     Document Type: Article
Times cited : (375)

References (15)
  • 5
    • 0028147744 scopus 로고
    • Voxel-based localization in frame-based and frameless stereotaxy and its accuracy
    • Lemieux L, Kitchen ND, Hughes SW, Thomas DG: Voxel-based localization in frame-based and frameless stereotaxy and its accuracy. Med Phys 21:1301-1310, 1994.
    • (1994) Med Phys , vol.21 , pp. 1301-1310
    • Lemieux, L.1    Kitchen, N.D.2    Hughes, S.W.3    Thomas, D.G.4
  • 7
    • 0030940761 scopus 로고    scopus 로고
    • An automatic six-degree-of-freedom image restoration algorithm for image-guided frameless stereotaxic radiosurgery
    • Murphy MJ: An automatic six-degree-of-freedom image restoration algorithm for image-guided frameless stereotaxic radiosurgery. Med Phys 24:857-866, 1997.
    • (1997) Med Phys , vol.24 , pp. 857-866
    • Murphy, M.J.1
  • 8
    • 0030442722 scopus 로고    scopus 로고
    • The accuracy of dose localization for an image-guided frameless radiosurgery system
    • Murphy MJ, Cox RS: The accuracy of dose localization for an image-guided frameless radiosurgery system. Med Phys 23:2043-2049, 1996.
    • (1996) Med Phys , vol.23 , pp. 2043-2049
    • Murphy, M.J.1    Cox, R.S.2
  • 12
    • 0026495463 scopus 로고
    • Early experience with the Gill Thomas Locator for computed tomography-directed stereotactic biopsy of intracranial lesions
    • Sofat A, Kratimenos G, Thomas DG: Early experience with the Gill Thomas Locator for computed tomography-directed stereotactic biopsy of intracranial lesions. Neurosurgery 31:972-974, 1992.
    • (1992) Neurosurgery , vol.31 , pp. 972-974
    • Sofat, A.1    Kratimenos, G.2    Thomas, D.G.3
  • 14
    • 58749084295 scopus 로고    scopus 로고
    • An improved page size 127 mm pixel amorphous-silicon image sensor for x-ray diagnostic medical imaging applications
    • Newport Beach, CA, February
    • Weisfield RL, Street RA, Apte R, More A: An improved page size 127 mm pixel amorphous-silicon image sensor for x-ray diagnostic medical imaging applications. Presented at the SPIE International Symposium on the Physics of Medical Imaging, Newport Beach, CA, February 1997.
    • (1997) SPIE International Symposium on the Physics of Medical Imaging
    • Weisfield, R.L.1    Street, R.A.2    Apte, R.3    More, A.4
  • 15
    • 0023939215 scopus 로고
    • Linear accelerator as a neurosurgical tool for stereotactic radiosurgery
    • Winston KR, Lutz W: Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. Neurosurgery 22:454-464, 1988.
    • (1988) Neurosurgery , vol.22 , pp. 454-464
    • Winston, K.R.1    Lutz, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.