메뉴 건너뛰기




Volumn 55, Issue 5, 2004, Pages 1138-1146

An anthropomorphic phantom study of the accuracy of CyberKnife spinal radiosurgery

Author keywords

Accuracy; CyberKnife; Spinal radiosurgery

Indexed keywords

ALGORITHM; ANTHROPOMETRY; ARTICLE; BEAM THERAPY; BRAIN INJURY; COMPUTER ASSISTED TOMOGRAPHY; CYBERKNIFE SPINAL RADIOSURGERY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; GAMMA IRRADIATION; IMPLANT; LINEAR ACCELERATOR; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION EXPOSURE; RADIOSURGERY; ROBOTICS; SCINTILLATION CAMERA; SPINAL CORD LESION; SPINE SURGERY; STEREOTAXIC SURGERY; TREATMENT PLANNING; X RAY FILM;

EID: 8744294785     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.NEU.0000141080.54647.11     Document Type: Article
Times cited : (109)

References (14)
  • 2
    • 0037234447 scopus 로고    scopus 로고
    • An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system
    • Chang SD, Main WT, Martin DP, Gibbs IC, Heilbrun MP: An analysis of the accuracy of the CyberKnife: A robotic frameless stereotactic radiosurgical system. Neurosurgery 52:140-147, 2003.
    • (2003) Neurosurgery , vol.52 , pp. 140-147
    • Chang, S.D.1    Main, W.T.2    Martin, D.P.3    Gibbs, I.C.4    Heilbrun, M.P.5
  • 3
    • 0033385438 scopus 로고    scopus 로고
    • Stereotactic imaging quality assurance using an anthropomorphic phantom
    • Drzymala RE, Mutic S: Stereotactic imaging quality assurance using an anthropomorphic phantom. Comput Aided Surg 4:248-255, 1999.
    • (1999) Comput Aided Surg , vol.4 , pp. 248-255
    • Drzymala, R.E.1    Mutic, S.2
  • 4
    • 0023875610 scopus 로고
    • A system for stereotactic radiosurgery with a linear accelerator
    • Lutz W, Winston KR, Maleki N: A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 14:373-381, 1988.
    • (1988) Int J Radiat Oncol Biol Phys , vol.14 , pp. 373-381
    • Lutz, W.1    Winston, K.R.2    Maleki, N.3
  • 6
    • 0030442722 scopus 로고    scopus 로고
    • The accuracy of dose localization for an image-guided frameless radiosurgery system
    • Murphy MJ, Cox RS: The accuracy of dose localization for an image-guided frameless radiosurgery system. Med Phys 23:2043-2049, 1996.
    • (1996) Med Phys , vol.23 , pp. 2043-2049
    • Murphy, M.J.1    Cox, R.S.2
  • 10
    • 0026466465 scopus 로고
    • Physics and dosimetry of the gamma knife
    • Wu A: Physics and dosimetry of the gamma knife. Neurosurg Clin N Am 3:35-50, 1992.
    • (1992) Neurosurg Clin N Am , vol.3 , pp. 35-50
    • Wu, A.1
  • 12
    • 0028177561 scopus 로고
    • Systematic analysis of errors in target localization and treatment delivery in stereotactic radiosurgery (SRS)
    • Yeung D, Palta J, Fontanesi J, Kun L: Systematic analysis of errors in target localization and treatment delivery in stereotactic radiosurgery (SRS). Int J Radiat Oncol Biol Phys 28:493-498, 1994.
    • (1994) Int J Radiat Oncol Biol Phys , vol.28 , pp. 493-498
    • Yeung, D.1    Palta, J.2    Fontanesi, J.3    Kun, L.4
  • 13
    • 0035056150 scopus 로고    scopus 로고
    • A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system
    • Yu C, Apuzzo MLJ, Zee CS, Petrovich Z: A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system. Neurosurgery 48:1092-1099, 2001.
    • (2001) Neurosurgery , vol.48 , pp. 1092-1099
    • Yu, C.1    Apuzzo, M.L.J.2    Zee, C.S.3    Petrovich, Z.4
  • 14
    • 85024967015 scopus 로고    scopus 로고
    • Quality assurance of beam accuracy for Leksell Gamma Unit
    • Yu C, Petrovich Z, Luxton G: Quality assurance of beam accuracy for Leksell Gamma Unit. J Appl Clin Med Phys 1:1-4, 2000.
    • (2000) J Appl Clin Med Phys , vol.1 , pp. 1-4
    • Yu, C.1    Petrovich, Z.2    Luxton, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.