메뉴 건너뛰기




Volumn 126, Issue 2, 2007, Pages 522-526

Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers

Author keywords

Formaldehyde; Mercaptophenol; Piezoresistive cantilever

Indexed keywords

BENZENE; ISOMERS; PHENOLS; PIEZOELECTRIC DEVICES; SELF ASSEMBLED MONOLAYERS; WATER;

EID: 34548613916     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2007.04.004     Document Type: Article
Times cited : (37)

References (28)
  • 1
    • 0021040571 scopus 로고
    • Formaldehyde release rate coefficients from selected consumer products
    • Pickreil J.A., Mokier B.V., and Griffis L.C. Formaldehyde release rate coefficients from selected consumer products. Environ. Sci. Technol. 17 (1983) 753-757
    • (1983) Environ. Sci. Technol. , vol.17 , pp. 753-757
    • Pickreil, J.A.1    Mokier, B.V.2    Griffis, L.C.3
  • 2
    • 0020286161 scopus 로고
    • Formaldehyde in indoor air: sources and toxicity
    • Gupta K.C., Ulsamer A.G., and Preuss P.W. Formaldehyde in indoor air: sources and toxicity. Environ. Int. 8 (1982) 349-358
    • (1982) Environ. Int. , vol.8 , pp. 349-358
    • Gupta, K.C.1    Ulsamer, A.G.2    Preuss, P.W.3
  • 3
    • 0026908660 scopus 로고
    • Methods for determination of low molecular weight carbonyl compounds in the atmosphere: a review
    • Vairavamurthy A., Roberts J.M., and Newman L. Methods for determination of low molecular weight carbonyl compounds in the atmosphere: a review. Atmos. Environ. 26A (1992) 1965-1993
    • (1992) Atmos. Environ. , vol.26 A , pp. 1965-1993
    • Vairavamurthy, A.1    Roberts, J.M.2    Newman, L.3
  • 4
    • 0018097929 scopus 로고
    • A kilometer pathlength fourier-transform infrared system for the study of trace pollutants in ambient and synthetic atmospheres
    • Tuazon E.C., Winer A.M., Graham R.A., and Pitts J.N. A kilometer pathlength fourier-transform infrared system for the study of trace pollutants in ambient and synthetic atmospheres. Atmos. Environ. 12 (1978) 865-875
    • (1978) Atmos. Environ. , vol.12 , pp. 865-875
    • Tuazon, E.C.1    Winer, A.M.2    Graham, R.A.3    Pitts, J.N.4
  • 6
    • 0034707717 scopus 로고    scopus 로고
    • A piezoelectric method for monitoring formaldehyde induced crosslink formation between poly-lysine and poly-deoxyguanosine
    • Bunde R.L., Jarvi E.J., and Rosentreter J.J. A piezoelectric method for monitoring formaldehyde induced crosslink formation between poly-lysine and poly-deoxyguanosine. Talanta 51 (2000) 159-171
    • (2000) Talanta , vol.51 , pp. 159-171
    • Bunde, R.L.1    Jarvi, E.J.2    Rosentreter, J.J.3
  • 7
    • 0020821792 scopus 로고
    • Determination of formaldehyde with an enzyme-coated Piezoelectric crystal detector
    • Guilbault G.G. Determination of formaldehyde with an enzyme-coated Piezoelectric crystal detector. Anal. Chem. 55 (1983) 1682-1684
    • (1983) Anal. Chem. , vol.55 , pp. 1682-1684
    • Guilbault, G.G.1
  • 8
    • 84912407604 scopus 로고
    • Determination of nanogram amounts of carbonyls as 2,4-dinitrophenylhydrazones by high-performance liquid chromatography
    • Fung K., and Grosejean D. Determination of nanogram amounts of carbonyls as 2,4-dinitrophenylhydrazones by high-performance liquid chromatography. Anal. Chem. 53 (1981) 168-171
    • (1981) Anal. Chem. , vol.53 , pp. 168-171
    • Fung, K.1    Grosejean, D.2
  • 9
    • 0024798033 scopus 로고
    • Some new aspects of a HPLC-method for the determination of traces of formaldehyde in air
    • Grömping A., and Cammann K. Some new aspects of a HPLC-method for the determination of traces of formaldehyde in air. Fresen. J. Anal. Chem. 335 (1989) 796-801
    • (1989) Fresen. J. Anal. Chem. , vol.335 , pp. 796-801
    • Grömping, A.1    Cammann, K.2
  • 10
    • 0039023256 scopus 로고    scopus 로고
    • Electrochemical enzyme sensor for formaldehyde operating in the gas phase
    • Hämmerle M., and Hall E.A.H. Electrochemical enzyme sensor for formaldehyde operating in the gas phase. Biosens. Bioelectron. 11 (1996) 239-246
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 239-246
    • Hämmerle, M.1    Hall, E.A.H.2
  • 11
    • 33845457734 scopus 로고    scopus 로고
    • On-line detection of atmospheric formaldehyde by a conductometric biosensor
    • Vianello F., Boscolo-Chio R., Signorini S., and Rigo A. On-line detection of atmospheric formaldehyde by a conductometric biosensor. Biosens. Bioelectron. 22 (2007) 920-925
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 920-925
    • Vianello, F.1    Boscolo-Chio, R.2    Signorini, S.3    Rigo, A.4
  • 15
    • 0348012951 scopus 로고    scopus 로고
    • Portable sick house syndrome gas monitoring system based on novel colorimetric reagents for the highly selective and sensitive detection of formaldehyde
    • Suzuki Y., Nakano N., and Suzuki K. Portable sick house syndrome gas monitoring system based on novel colorimetric reagents for the highly selective and sensitive detection of formaldehyde. Environ. Sci. Technol. 37 (2003) 5695-5700
    • (2003) Environ. Sci. Technol. , vol.37 , pp. 5695-5700
    • Suzuki, Y.1    Nakano, N.2    Suzuki, K.3
  • 16
    • 14744293669 scopus 로고    scopus 로고
    • Development of a novel hand-held formaldehyde gas sensor for the rapid detection of sick building syndrome
    • Kawamura K., Kerman K., Fujihara M., Nagatani N., Hashiba T., and Tamiya E. Development of a novel hand-held formaldehyde gas sensor for the rapid detection of sick building syndrome. Sens. Actuators B 105 (2005) 495-501
    • (2005) Sens. Actuators B , vol.105 , pp. 495-501
    • Kawamura, K.1    Kerman, K.2    Fujihara, M.3    Nagatani, N.4    Hashiba, T.5    Tamiya, E.6
  • 17
    • 0033977788 scopus 로고    scopus 로고
    • Environmental sensors based on micromachined cantilevers with integrated read-out
    • Boisen A., Thaysen J., Jensenius H., and Hansen O. Environmental sensors based on micromachined cantilevers with integrated read-out. Ultramicroscopy 82 (2000) 11-16
    • (2000) Ultramicroscopy , vol.82 , pp. 11-16
    • Boisen, A.1    Thaysen, J.2    Jensenius, H.3    Hansen, O.4
  • 19
    • 24944439851 scopus 로고    scopus 로고
    • Nanomechanical sensing of DNA sequences using piezoresistive cantilevers
    • Mukhopadhyay R., Lorentzen M., Kjems J., and Besenbacher F. Nanomechanical sensing of DNA sequences using piezoresistive cantilevers. Langmuir 30 (2005) 8400-8408
    • (2005) Langmuir , vol.30 , pp. 8400-8408
    • Mukhopadhyay, R.1    Lorentzen, M.2    Kjems, J.3    Besenbacher, F.4
  • 22
    • 33748049832 scopus 로고    scopus 로고
    • Mechanical detection of liposomes using piezoresistive cantilever
    • Hyun S.-J., Kim H.-S., Kim Y.-J., and Jung H.-I. Mechanical detection of liposomes using piezoresistive cantilever. Sens. Actuators B 117 (2006) 415-419
    • (2006) Sens. Actuators B , vol.117 , pp. 415-419
    • Hyun, S.-J.1    Kim, H.-S.2    Kim, Y.-J.3    Jung, H.-I.4
  • 23
    • 34547239174 scopus 로고
    • Thermal and ambient-induced deflections of scanning force microscope cantilevers
    • Thundat T., Warmack R.J., Chen G.Y., and Allison D.P. Thermal and ambient-induced deflections of scanning force microscope cantilevers. Appl. Phys. Lett. 64 (1994) 2894-2896
    • (1994) Appl. Phys. Lett. , vol.64 , pp. 2894-2896
    • Thundat, T.1    Warmack, R.J.2    Chen, G.Y.3    Allison, D.P.4
  • 24
    • 0001682658 scopus 로고
    • Observation of a chemical reaction using a micromechanical sensor
    • Gimzewski J.K., Gerber C., Meyer E., and Schlittler R.R. Observation of a chemical reaction using a micromechanical sensor. Chem. Phys. Lett. 217 (1994) 589-594
    • (1994) Chem. Phys. Lett. , vol.217 , pp. 589-594
    • Gimzewski, J.K.1    Gerber, C.2    Meyer, E.3    Schlittler, R.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.