메뉴 건너뛰기




Volumn 16, Issue 4, 2007, Pages 786-794

Discrete chemical release from a microfluidic chip

Author keywords

Air gap; Discrete chemical stimulation; Microfluidic chip; Picoliter chemical release; Pulsed liquid ejection

Indexed keywords

BIOCHEMISTRY; BIOMEDICAL ENGINEERING; COMPUTER SIMULATION; DRUG PRODUCTS; HYDROPHOBICITY;

EID: 34548012627     PISSN: 10577157     EISSN: None     Source Type: Journal    
DOI: 10.1109/JMEMS.2007.892911     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 1642452589 scopus 로고    scopus 로고
    • Integrated microsystems for controlled drug delivery
    • S. Razzacki, P. Thwar, M. Yang, V. Ugaz, and M. Burns, "Integrated microsystems for controlled drug delivery," Adv. Drug Deliv. Rev. vol. 56, no. 2, pp. 185-198, 2004.
    • (2004) Adv. Drug Deliv. Rev , vol.56 , Issue.2 , pp. 185-198
    • Razzacki, S.1    Thwar, P.2    Yang, M.3    Ugaz, V.4    Burns, M.5
  • 2
    • 0242499354 scopus 로고    scopus 로고
    • Multi-pulse drug delivery from a resorbable polymeric microchip device
    • Nov
    • A. Grayson, I. Choi, B. Tyler, P. Wang, H. Brem, M. Cima, and R. Langer, "Multi-pulse drug delivery from a resorbable polymeric microchip device," Nat. Mater., vol. 2, no. 11, pp. 767-772, Nov. 2003.
    • (2003) Nat. Mater , vol.2 , Issue.11 , pp. 767-772
    • Grayson, A.1    Choi, I.2    Tyler, B.3    Wang, P.4    Brem, H.5    Cima, M.6    Langer, R.7
  • 3
    • 14644439212 scopus 로고    scopus 로고
    • pH-Triggered thermally responsive polymer core-shell nanoparticles for targeted drug delivery
    • Feb
    • K. Soppimath, C. Tan, and Y. Yang, "pH-Triggered thermally responsive polymer core-shell nanoparticles for targeted drug delivery," Adv. Mater., vol. 17, no. 3, pp. 318-323, Feb. 2005.
    • (2005) Adv. Mater , vol.17 , Issue.3 , pp. 318-323
    • Soppimath, K.1    Tan, C.2    Yang, Y.3
  • 4
    • 0032674333 scopus 로고    scopus 로고
    • A high-performance silicon micropump for an implantable drug delivery system
    • D. Maillefer, H. van Lintel, G. Rey-mermet, and R. Hirschi, "A high-performance silicon micropump for an implantable drug delivery system," in Proc. IEEE MEMS, 1999, vol. 12, pp. 541-546.
    • (1999) Proc. IEEE MEMS , vol.12 , pp. 541-546
    • Maillefer, D.1    van Lintel, H.2    Rey-mermet, G.3    Hirschi, R.4
  • 5
    • 33751583911 scopus 로고    scopus 로고
    • Polymers in controlled drug delivery
    • L. Brannon-Peppas, "Polymers in controlled drug delivery," Med. Plast. Biomater., vol. 4, no. 6, pp. 34-44, 1997.
    • (1997) Med. Plast. Biomater , vol.4 , Issue.6 , pp. 34-44
    • Brannon-Peppas, L.1
  • 6
    • 84984752178 scopus 로고    scopus 로고
    • Drug delivery: Pulsed polymers
    • Nov
    • J. West, "Drug delivery: Pulsed polymers," Nat. Mater, vol. 2, no. 11, pp. 709-710, Nov. 2003.
    • (2003) Nat. Mater , vol.2 , Issue.11 , pp. 709-710
    • West, J.1
  • 7
    • 1642534297 scopus 로고    scopus 로고
    • Electronic MEMS for triggered delivery
    • A. Grayson, R. Shawgo, Y. Li, and M. Cima, "Electronic MEMS for triggered delivery," Adv. Drug Deliv. Rev., vol. 56, no. 2, pp. 173-184, 2004.
    • (2004) Adv. Drug Deliv. Rev , vol.56 , Issue.2 , pp. 173-184
    • Grayson, A.1    Shawgo, R.2    Li, Y.3    Cima, M.4
  • 8
    • 0033611506 scopus 로고    scopus 로고
    • A controlled-release microchip
    • Jan
    • J. Santini, Jr., M. Cima, and R. Langer, "A controlled-release microchip," Nature, vol. 397, no. 6717, pp. 335-338, Jan. 1999.
    • (1999) Nature , vol.397 , Issue.6717 , pp. 335-338
    • Santini Jr., J.1    Cima, M.2    Langer, R.3
  • 9
    • 0034905128 scopus 로고    scopus 로고
    • Design of a self-regulated drug delivery device
    • Jun
    • X. Cao, S. Lai, and J. Lee, "Design of a self-regulated drug delivery device," Biomed. Microdevices, vol. 3, no. 2, pp. 109-118, Jun. 2001.
    • (2001) Biomed. Microdevices , vol.3 , Issue.2 , pp. 109-118
    • Cao, X.1    Lai, S.2    Lee, J.3
  • 10
    • 0344270926 scopus 로고    scopus 로고
    • Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies
    • Nov
    • D. McAllister et al., "Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies," Proc. Nat. Acad. Sci., vol. 100, no. 24, pp. 13755-13760, Nov. 2003.
    • (2003) Proc. Nat. Acad. Sci , vol.100 , Issue.24 , pp. 13755-13760
    • McAllister, D.1
  • 11
    • 0037871729 scopus 로고    scopus 로고
    • Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer
    • Jun
    • P. Griss and G. Stemme, "Side-opened out-of-plane microneedles for microfluidic transdermal liquid transfer," J. Microelectromech. Sys. vol. 12, no. 3, pp. 296-301, Jun. 2003.
    • (2003) J. Microelectromech. Sys , vol.12 , Issue.3 , pp. 296-301
    • Griss, P.1    Stemme, G.2
  • 12
    • 3042798466 scopus 로고    scopus 로고
    • Localized chemical release from an artificial synapse chip
    • Jul
    • M. Peterman, J. Nooland, M. Blumenkranz, and H. Fishman, "Localized chemical release from an artificial synapse chip," Proc. Nat. Acad. Sci., vol. 101, no. 27, pp. 9951-9954, Jul. 2004.
    • (2004) Proc. Nat. Acad. Sci , vol.101 , Issue.27 , pp. 9951-9954
    • Peterman, M.1    Nooland, J.2    Blumenkranz, M.3    Fishman, H.4
  • 13
    • 0037900532 scopus 로고    scopus 로고
    • Localized neurotransmitter release for use in a prototype retinal interface
    • Jul
    • M. Peterman et al., "Localized neurotransmitter release for use in a prototype retinal interface," Invest. Ophthalmol. Vis. Sci., vol. 44, no. 7, pp. 3144-3149, Jul. 2003.
    • (2003) Invest. Ophthalmol. Vis. Sci , vol.44 , Issue.7 , pp. 3144-3149
    • Peterman, M.1
  • 14
    • 0142094116 scopus 로고    scopus 로고
    • Towards a neurotransmitter-based retinal prosthesis using an inkjet print-head
    • Sep
    • J. Noolandi, M. C. Peterman, P. Huie, C. Lee, M. S. Blumenkranz, and H. A. Fishman, "Towards a neurotransmitter-based retinal prosthesis using an inkjet print-head," Biomed. Microdevices, vol. 5, no. 3, pp. 195-199, Sep. 2003.
    • (2003) Biomed. Microdevices , vol.5 , Issue.3 , pp. 195-199
    • Noolandi, J.1    Peterman, M.C.2    Huie, P.3    Lee, C.4    Blumenkranz, M.S.5    Fishman, H.A.6
  • 15
    • 0346710425 scopus 로고    scopus 로고
    • Localized chemical stimulation to micropatterned cells using multiple laminar fluid flows
    • Aug
    • H. Kaji, M. Nishizawa, and T. Matsue, "Localized chemical stimulation to micropatterned cells using multiple laminar fluid flows," Lab Chip, vol. 3, no. 3, pp. 208-211, Aug. 2003.
    • (2003) Lab Chip , vol.3 , Issue.3 , pp. 208-211
    • Kaji, H.1    Nishizawa, M.2    Matsue, T.3
  • 16
    • 1642349268 scopus 로고    scopus 로고
    • Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity
    • May
    • S. Metz, A. Bertsch, D. Bertrand, and P. Renaud, "Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity," Biosens. Bioelectron., vol. 19, no. 10, pp. 1309-1318, May 2004.
    • (2004) Biosens. Bioelectron , vol.19 , Issue.10 , pp. 1309-1318
    • Metz, S.1    Bertsch, A.2    Bertrand, D.3    Renaud, P.4
  • 17
    • 0031214943 scopus 로고    scopus 로고
    • J. Chen, K. Wise, J. Hetke, and S. Bledsoe, Jr., A multichannel neural probe for selective chemical delivery at the cellular level, IEEE Trans. Biomed. Eng., 44, no. 8, pp. 760-769, Aug. 1997.
    • J. Chen, K. Wise, J. Hetke, and S. Bledsoe, Jr., "A multichannel neural probe for selective chemical delivery at the cellular level," IEEE Trans. Biomed. Eng., vol. 44, no. 8, pp. 760-769, Aug. 1997.
  • 18
    • 34548048024 scopus 로고    scopus 로고
    • Localized functional chemical stimulation of TE 671 cells adherent on nanoporous membrane by calcein and acetylcholine
    • to be published
    • S. Zibek, P. Koltay, M. Hu, R. Zengerle, W. Nisch, A. Stett, and M. Stelzle, "Localized functional chemical stimulation of TE 671 cells adherent on nanoporous membrane by calcein and acetylcholine," Biophys. J.-Biophys. Lett., to be published.
    • Biophys. J.-Biophys. Lett
    • Zibek, S.1    Koltay, P.2    Hu, M.3    Zengerle, R.4    Nisch, W.5    Stett, A.6    Stelzle, M.7
  • 20
    • 0026959857 scopus 로고
    • Three-dimensional calculation of bubble growth and drop ejection in a bubble jet
    • A. Asai, "Three-dimensional calculation of bubble growth and drop ejection in a bubble jet," Trans. ASME, J. Fluids Eng., vol. 114, no. 4, pp. 638-641, 1992.
    • (1992) Trans. ASME, J. Fluids Eng , vol.114 , Issue.4 , pp. 638-641
    • Asai, A.1
  • 21
    • 85010582998 scopus 로고
    • Bubble dynamics in boiling under high heat flux pulse heating
    • A. Asai, "Bubble dynamics in boiling under high heat flux pulse heating," Trans. ASME, J. Heat Transfer, vol. 113, no. 4, pp. 973-979, 1991.
    • (1991) Trans. ASME, J. Heat Transfer , vol.113 , Issue.4 , pp. 973-979
    • Asai, A.1
  • 22
    • 34548023362 scopus 로고
    • 3rd ed, London, U.K, Addison-Wesley
    • G. Castellan, Physical Chemistry, 3rd ed, vol. 89. London, U.K.: Addison-Wesley, 1983.
    • (1983) Physical Chemistry , vol.89
    • Castellan, G.1
  • 23
    • 0021372828 scopus 로고
    • Hydrodynamics of small tubular pumps
    • J. Dijksman, "Hydrodynamics of small tubular pumps," J. Fluid Mech. vol. 139, pp. 173-191, 1984.
    • (1984) J. Fluid Mech , vol.139 , pp. 173-191
    • Dijksman, J.1
  • 24
    • 33746832133 scopus 로고    scopus 로고
    • Mechanism of drop constriction in a drop-on-demand inkjet system
    • Dec
    • R. Badie and D. Lange, "Mechanism of drop constriction in a drop-on-demand inkjet system," Proc. R. Soc. Lond. A, Math. Phys. Sci., vol. 453, no. 1967, pp. 2573-2581, Dec. 1997.
    • (1997) Proc. R. Soc. Lond. A, Math. Phys. Sci , vol.453 , Issue.1967 , pp. 2573-2581
    • Badie, R.1    Lange, D.2
  • 25
    • 0021422097 scopus 로고
    • Numerical calculation of the fluid dynamics of drop-on-demand jets
    • May
    • J. Fromm, "Numerical calculation of the fluid dynamics of drop-on-demand jets," IBM J. Res. Develop., vol. 28, no. 3, pp. 322-333, May 1984.
    • (1984) IBM J. Res. Develop , vol.28 , Issue.3 , pp. 322-333
    • Fromm, J.1
  • 27
    • 18744399272 scopus 로고    scopus 로고
    • Multi-layer SU-8 lift-off technology for microfluidic devices
    • Jun
    • B. Bohl, R. Steger, R. Zengerle, and P. Koltay, "Multi-layer SU-8 lift-off technology for microfluidic devices," J. Micromech. Microeng., vol. 15, no. 6, pp. 1125-1130, Jun. 2005.
    • (2005) J. Micromech. Microeng , vol.15 , Issue.6 , pp. 1125-1130
    • Bohl, B.1    Steger, R.2    Zengerle, R.3    Koltay, P.4
  • 28
    • 0036773087 scopus 로고    scopus 로고
    • A high-resolution high-frequency monolithic top-shooting microinjector free of satellite drops - Part I: Concept, design, and model
    • Oct
    • F. Tseng, C. Kim, and C. Ho, "A high-resolution high-frequency monolithic top-shooting microinjector free of satellite drops - Part I: Concept, design, and model," J. Microelectromech. Syst., vol. 11, no. 5, pp. 427-436, Oct. 2002.
    • (2002) J. Microelectromech. Syst , vol.11 , Issue.5 , pp. 427-436
    • Tseng, F.1    Kim, C.2    Ho, C.3
  • 29
    • 0036772739 scopus 로고    scopus 로고
    • A high-resolution high-frequency monolithic top-shooting microinjector free of satellite drops - Part II: Fabrication, implementation, and characterization
    • Oct
    • F. Tseng, C. Kim, and C. Ho, "A high-resolution high-frequency monolithic top-shooting microinjector free of satellite drops - Part II: Fabrication, implementation, and characterization," J. Microelectromech. Syst., vol. 11, no. 5, pp. 437-447, Oct. 2002.
    • (2002) J. Microelectromech. Syst , vol.11 , Issue.5 , pp. 437-447
    • Tseng, F.1    Kim, C.2    Ho, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.