메뉴 건너뛰기




Volumn 14, Issue 6, 2007, Pages 677-684

Evaluation of 11-Gauge and 9-Gauge Vacuum-Assisted Breast Biopsy Systems in a Breast Parenchymal Model

Author keywords

breast neoplasms; Equipment Design; experimental; Vacuum assisted breast biopsy

Indexed keywords

ANIMAL TISSUE; ARTICLE; BIOPSY DEVICE; BIOPSY TECHNIQUE; BREAST BIOPSY; GEOMETRY; NONHUMAN; PRIORITY JOURNAL; STATISTICAL ANALYSIS; TISSUE STRUCTURE; TURKEY (BIRD); VACUUM;

EID: 34250161313     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2007.02.013     Document Type: Article
Times cited : (11)

References (25)
  • 1
    • 0031606241 scopus 로고    scopus 로고
    • Minimally invasive stereotaxic vacuum core breast biopsy
    • Heywang-Kobrunner S.H., Schaumloffel U., et al. Minimally invasive stereotaxic vacuum core breast biopsy. Eur Radiol 8 (1998) 377-385
    • (1998) Eur Radiol , vol.8 , pp. 377-385
    • Heywang-Kobrunner, S.H.1    Schaumloffel, U.2
  • 2
    • 1542264000 scopus 로고    scopus 로고
    • Stereotactic 11-gauge vacuum-assisted breast biopsy: Influence of number of specimens on diagnostic accuracy
    • Lomoschitz F.M., Helbich T.H., Rudas M., et al. Stereotactic 11-gauge vacuum-assisted breast biopsy: Influence of number of specimens on diagnostic accuracy. Radiology 232 (2004) 897-903
    • (2004) Radiology , vol.232 , pp. 897-903
    • Lomoschitz, F.M.1    Helbich, T.H.2    Rudas, M.3
  • 3
    • 1542315635 scopus 로고    scopus 로고
    • Stereotactic and ultrasound-guided breast biopsy
    • Helbich T.H., Matzek W., and Fuchsjager M.H. Stereotactic and ultrasound-guided breast biopsy. Eur Radiol 14 (2004) 383-393
    • (2004) Eur Radiol , vol.14 , pp. 383-393
    • Helbich, T.H.1    Matzek, W.2    Fuchsjager, M.H.3
  • 4
    • 24644467383 scopus 로고    scopus 로고
    • MRI-guided 9-gauge vacuum-assisted breast biopsy: Initial clinical experience
    • Liberman L., Bracero N., Morris E., et al. MRI-guided 9-gauge vacuum-assisted breast biopsy: Initial clinical experience. AJR Am J Roentgenol 185 (2005) 183-193
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 183-193
    • Liberman, L.1    Bracero, N.2    Morris, E.3
  • 5
    • 21644461330 scopus 로고    scopus 로고
    • Core needle biopsy (CNB) as a diagnostic method for breast lesions: Comparison with fine needle aspiration cytology (FNA)
    • Oyama T., Koibuchi Y., and McKee G. Core needle biopsy (CNB) as a diagnostic method for breast lesions: Comparison with fine needle aspiration cytology (FNA). Breast Cancer 11 (2004) 339-342
    • (2004) Breast Cancer , vol.11 , pp. 339-342
    • Oyama, T.1    Koibuchi, Y.2    McKee, G.3
  • 6
    • 0036479539 scopus 로고    scopus 로고
    • Interventional ultrasound
    • Otto R. Interventional ultrasound. Eur Radiol 12 (2002) 283-287
    • (2002) Eur Radiol , vol.12 , pp. 283-287
    • Otto, R.1
  • 7
    • 30844462554 scopus 로고    scopus 로고
    • Microcalcifications of the breast: How does radiologic classification correlate with histology?
    • Muller-Schimpfle M., Wersebe A., Xydeas T., et al. Microcalcifications of the breast: How does radiologic classification correlate with histology?. Acta Radiol 46 (2005) 774-781
    • (2005) Acta Radiol , vol.46 , pp. 774-781
    • Muller-Schimpfle, M.1    Wersebe, A.2    Xydeas, T.3
  • 8
    • 0036232744 scopus 로고    scopus 로고
    • A Comparison of core needle breast biopsy techniques: Freehand versus three-dimensional US guidance
    • Smith W.L., Surry K.J., Kumar A., et al. A Comparison of core needle breast biopsy techniques: Freehand versus three-dimensional US guidance. Acad Radiol 9 (2002) 541-550
    • (2002) Acad Radiol , vol.9 , pp. 541-550
    • Smith, W.L.1    Surry, K.J.2    Kumar, A.3
  • 9
    • 0035158522 scopus 로고    scopus 로고
    • The role of needle biopsy in the diagnosis of breast lesions
    • Litherland J. The role of needle biopsy in the diagnosis of breast lesions. Breast 10 (2001) 383-387
    • (2001) Breast , vol.10 , pp. 383-387
    • Litherland, J.1
  • 10
    • 2442667904 scopus 로고    scopus 로고
    • [Radiologic-histopathologic correlation of microcalcifications from 11g vacuum biopsy: analysis of 3196 core biopsies]
    • Fischmann A., Pietsch-Breitfeld B., Muller-Schimpfle M., et al. [Radiologic-histopathologic correlation of microcalcifications from 11g vacuum biopsy: analysis of 3196 core biopsies]. Rofo 176 (2004) 538-543
    • (2004) Rofo , vol.176 , pp. 538-543
    • Fischmann, A.1    Pietsch-Breitfeld, B.2    Muller-Schimpfle, M.3
  • 11
    • 0030876771 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device
    • Meyer J.E., Smith D.N., DiPiro P.J., et al. Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device. Radiology 204 (1997) 575-576
    • (1997) Radiology , vol.204 , pp. 575-576
    • Meyer, J.E.1    Smith, D.N.2    DiPiro, P.J.3
  • 12
    • 0031771461 scopus 로고    scopus 로고
    • Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques
    • Jackman R.J., Marzoni Jr. F.A., and Nowels K.W. Percutaneous removal of benign mammographic lesions: Comparison of automated large-core and directional vacuum-assisted stereotactic biopsy techniques. AJR Am J Roentgenol 171 (1998) 1325-1330
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1325-1330
    • Jackman, R.J.1    Marzoni Jr., F.A.2    Nowels, K.W.3
  • 13
    • 33645120598 scopus 로고    scopus 로고
    • Breast microcalcifications: Retrieval failure at prone stereotactic core and vacuum breast biopsy-Frequency, causes, and outcome
    • Jackman R.J., and Rodriguez-Soto J. Breast microcalcifications: Retrieval failure at prone stereotactic core and vacuum breast biopsy-Frequency, causes, and outcome. Radiology 239 (2006) 61-70
    • (2006) Radiology , vol.239 , pp. 61-70
    • Jackman, R.J.1    Rodriguez-Soto, J.2
  • 14
    • 0030723987 scopus 로고    scopus 로고
    • Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization
    • Burbank F., and Forcier N. Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization. Radiology 205 (1997) 407-415
    • (1997) Radiology , vol.205 , pp. 407-415
    • Burbank, F.1    Forcier, N.2
  • 15
    • 0033030531 scopus 로고    scopus 로고
    • Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun
    • Philpotts L.E., Shaheen N.A., Carter D., et al. Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun. AJR Am J Roentgenol 172 (1999) 683-687
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 683-687
    • Philpotts, L.E.1    Shaheen, N.A.2    Carter, D.3
  • 16
    • 33645979918 scopus 로고    scopus 로고
    • A comparison of the accuracy of two minimally invasive breast biopsy methods: A systematic literature review and meta-analysis
    • Fahrbach K., Sledge I., Cella C., et al. A comparison of the accuracy of two minimally invasive breast biopsy methods: A systematic literature review and meta-analysis. Arch Gynecol Obstet 274 (2006) 63-73
    • (2006) Arch Gynecol Obstet , vol.274 , pp. 63-73
    • Fahrbach, K.1    Sledge, I.2    Cella, C.3
  • 17
    • 0034999853 scopus 로고    scopus 로고
    • Nonpalpable breast cancer: Percutaneous diagnosis with 11- and 8-gauge stereotactic vacuum-assisted biopsy devices
    • Brem R.F., Schoonjans J.M., Goodman S.N., et al. Nonpalpable breast cancer: Percutaneous diagnosis with 11- and 8-gauge stereotactic vacuum-assisted biopsy devices. Radiology 219 (2001) 793-796
    • (2001) Radiology , vol.219 , pp. 793-796
    • Brem, R.F.1    Schoonjans, J.M.2    Goodman, S.N.3
  • 18
    • 0037286864 scopus 로고    scopus 로고
    • New possibilities of diagnostic imaging and intervention
    • Heywang-Kobrunner S.H. New possibilities of diagnostic imaging and intervention. Curr Probl Cancer 27 (2003) 32-38
    • (2003) Curr Probl Cancer , vol.27 , pp. 32-38
    • Heywang-Kobrunner, S.H.1
  • 19
    • 4143076806 scopus 로고    scopus 로고
    • MR-guided vacuum-assisted breast biopsy: Accuracy of targeting and success in sampling in a phantom model
    • Lehman C.D., and Aikawa T. MR-guided vacuum-assisted breast biopsy: Accuracy of targeting and success in sampling in a phantom model. Radiology 232 (2004) 911-914
    • (2004) Radiology , vol.232 , pp. 911-914
    • Lehman, C.D.1    Aikawa, T.2
  • 20
    • 0033666363 scopus 로고    scopus 로고
    • [Preoperative marking and biopsy of nonpalpable breast lesions with a guidance system for the open Magnetom]
    • Sittek H., Linsmeier E., Perlet C., et al. [Preoperative marking and biopsy of nonpalpable breast lesions with a guidance system for the open Magnetom]. Radiologe 40 (2000) 1098-1105
    • (2000) Radiologe , vol.40 , pp. 1098-1105
    • Sittek, H.1    Linsmeier, E.2    Perlet, C.3
  • 21
    • 33646478429 scopus 로고    scopus 로고
    • [Value of MR-guided localization and biopsy in breast lesions]
    • Obenauer S., Grabbe E., and Knollmann F. [Value of MR-guided localization and biopsy in breast lesions]. Rofo 178 (2006) 477-483
    • (2006) Rofo , vol.178 , pp. 477-483
    • Obenauer, S.1    Grabbe, E.2    Knollmann, F.3
  • 22
    • 3142781328 scopus 로고    scopus 로고
    • [First clinical experience with extended planning and navigation in an interventional MRI unit]
    • Moche M., Schmitgen A., Schneider J.P., et al. [First clinical experience with extended planning and navigation in an interventional MRI unit]. Rofo 176 (2004) 1013-1020
    • (2004) Rofo , vol.176 , pp. 1013-1020
    • Moche, M.1    Schmitgen, A.2    Schneider, J.P.3
  • 23
    • 0030770302 scopus 로고    scopus 로고
    • Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model
    • Berg W.A., Krebs T.L., Campassi C., et al. Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 205 (1997) 203-208
    • (1997) Radiology , vol.205 , pp. 203-208
    • Berg, W.A.1    Krebs, T.L.2    Campassi, C.3
  • 24
    • 17744418366 scopus 로고    scopus 로고
    • Interdisciplinary consensus on the use and technique of vacuum-assisted stereotactic breast biopsy
    • Heywang-Kobrunner S.H., Schreer I., Decker T., et al. Interdisciplinary consensus on the use and technique of vacuum-assisted stereotactic breast biopsy. Eur J Radiol 47 (2003) 232-236
    • (2003) Eur J Radiol , vol.47 , pp. 232-236
    • Heywang-Kobrunner, S.H.1    Schreer, I.2    Decker, T.3
  • 25
    • 0033506109 scopus 로고    scopus 로고
    • Comparison of mammographically guided breast biopsy techniques
    • discussion 630-623
    • Velanovich V., Lewis Jr. F.R., Nathanson S.D., et al. Comparison of mammographically guided breast biopsy techniques. Ann Surg 229 (1999) 625-630 discussion 630-623
    • (1999) Ann Surg , vol.229 , pp. 625-630
    • Velanovich, V.1    Lewis Jr., F.R.2    Nathanson, S.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.