메뉴 건너뛰기




Volumn 239, Issue 1, 2006, Pages 61-70

Breast microcalcifications: Retrieval failure at prone stereotactic core and vacuum breast biopsy - Frequency, causes, and outcome

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; BREAST BIOPSY; BREAST CALCIFICATION; BREAST CANCER; BREAST HYPERPLASIA; DIAGNOSTIC ERROR; FEMALE; HISTOPATHOLOGY; HUMAN; MAJOR CLINICAL STUDY; MAMMOGRAPHY; PRIORITY JOURNAL; RETROSPECTIVE STUDY; REVIEW; STEREOTAXIC SURGERY; VACUUM;

EID: 33645120598     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2383041953     Document Type: Review
Times cited : (60)

References (46)
  • 1
    • 0030749032 scopus 로고    scopus 로고
    • Needle-localized breast biopsy: Why do we fail?
    • Jackman RJ, Marzoni FA. Needle-localized breast biopsy: why do we fail? Radiology 1997;204:677-684.
    • (1997) Radiology , vol.204 , pp. 677-684
    • Jackman, R.J.1    Marzoni, F.A.2
  • 2
    • 0029894202 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Its history, its present, and its future
    • Burbank F. Stereotactic breast biopsy: its history, its present, and its future. Am Surg 1996;62:128-150.
    • (1996) Am Surg , vol.62 , pp. 128-150
    • Burbank, F.1
  • 3
    • 0029938332 scopus 로고    scopus 로고
    • A practical approach to minimally invasive breast biopsy
    • Parker SH, Burbank F. A practical approach to minimally invasive breast biopsy. Radiology 1996;200:11-20.
    • (1996) Radiology , vol.200 , pp. 11-20
    • Parker, S.H.1    Burbank, F.2
  • 4
    • 0030976322 scopus 로고    scopus 로고
    • Stereotactic core-needle biopsy of the breast: A report of the Joint Task Force of the American College of Radiology, American College of Surgeons, and College of American Pathologists
    • Bassert L, Winchester DP, Caplan RB, et al. Stereotactic core-needle biopsy of the breast: a report of the Joint Task Force of the American College of Radiology, American College of Surgeons, and College of American Pathologists. CA Cancer J Clin 1997;47:171-190.
    • (1997) CA Cancer J Clin , vol.47 , pp. 171-190
    • Bassert, L.1    Winchester, D.P.2    Caplan, R.B.3
  • 5
    • 0034851394 scopus 로고    scopus 로고
    • Image-detected breast cancer: State of the art diagnosis and treatment
    • International Breast Cancer Consensus Conference. Image-detected breast cancer: state of the art diagnosis and treatment. J Am Coll Surg 2001;193:297-302.
    • (2001) J Am Coll Surg , vol.193 , pp. 297-302
  • 6
    • 0036065866 scopus 로고    scopus 로고
    • Percutaneous image-guided core breast biopsy
    • Liberman L. Percutaneous image-guided core breast biopsy. Radiol Clin North Am 2002;40:483-500.
    • (2002) Radiol Clin North Am , vol.40 , pp. 483-500
    • Liberman, L.1
  • 7
    • 0037369149 scopus 로고    scopus 로고
    • Stereotactic histologic biopsy with patients prone: Technical feasibility in 98% of mammographically detected lesions
    • Jackman RJ, Marzoni FA. Stereotactic histologic biopsy with patients prone: technical feasibility in 98% of mammographically detected lesions. AJR Am J Roentgenol 2003;180:785-794.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 785-794
    • Jackman, R.J.1    Marzoni, F.A.2
  • 9
    • 0032976596 scopus 로고    scopus 로고
    • Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up
    • Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni FA, Finkelstein SI, Shepard MJ. Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: False-negative and histologic underestimation rates after long-term follow-up. Radiology 1999;210:799-805.
    • (1999) Radiology , vol.210 , pp. 799-805
    • Jackman, R.J.1    Nowels, K.W.2    Rodriguez-Soto, J.3    Marzoni, F.A.4    Finkelstein, S.I.5    Shepard, M.J.6
  • 10
    • 0033008296 scopus 로고    scopus 로고
    • Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: Frequency of mammographic change and false-negative rate
    • Lee CH, Philpotts LE, Horvath LJ, Torino I. Follow-up of breast lesions diagnosed as benign with stereotactic core-needle biopsy: frequency of mammographic change and false-negative rate. Radiology 1999;212:189-194.
    • (1999) Radiology , vol.212 , pp. 189-194
    • Lee, C.H.1    Philpotts, L.E.2    Horvath, L.J.3    Torino, I.4
  • 11
    • 0034011038 scopus 로고    scopus 로고
    • Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: A meta-analysis
    • Verkooijen HM, Peeters PHM, Buskens E, et al. Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer 2000;82:1017-1021.
    • (2000) Br J Cancer , vol.82 , pp. 1017-1021
    • Verkooijen, H.M.1    Phm, P.2    Buskens, E.3
  • 12
    • 0033810096 scopus 로고    scopus 로고
    • Stereotactic core-needle breast biopsy by surgeons: Minimum 2-year follow-up of benign lesions
    • Burns RP, Brown JP, Roe M, Sprouse LR, Yancey AE, Witherspoon LE. Stereotactic core-needle breast biopsy by surgeons: minimum 2-year follow-up of benign lesions. Ann Surg 2000;232:542-548.
    • (2000) Ann Surg , vol.232 , pp. 542-548
    • Burns, R.P.1    Brown, J.P.2    Roe, M.3    Sprouse, L.R.4    Yancey, A.E.5    Witherspoon, L.E.6
  • 13
    • 0031941316 scopus 로고    scopus 로고
    • Histologic-radiologic correlation of mammographically detected microcalcification in stereotactic core biopsies
    • Dahlstrom JE, Sutton S, Jain S. Histologic-radiologic correlation of mammographically detected microcalcification in stereotactic core biopsies. Am J Surg Pathol 1998;22:256-259.
    • (1998) Am J Surg Pathol , vol.22 , pp. 256-259
    • Dahlstrom, J.E.1    Sutton, S.2    Jain, S.3
  • 14
    • 0027170050 scopus 로고
    • Occult breast calcifications sampled with large-core biopsy: Confirmation with radiography of the specimen
    • Meyer JE, Lester SC, Frenna TH, White FV. Occult breast calcifications sampled with large-core biopsy: confirmation with radiography of the specimen. Radiology 1993;188:581-582.
    • (1993) Radiology , vol.188 , pp. 581-582
    • Meyer, J.E.1    Lester, S.C.2    Frenna, T.H.3    White, F.V.4
  • 15
    • 0028013123 scopus 로고
    • Radiography of microcalcifications in stereotaxic mammary core biopsy specimens
    • Liberman L, Evans WP, Dershaw DD, et al. Radiography of microcalcifications in stereotaxic mammary core biopsy specimens. Radiology 1994;190:223-225.
    • (1994) Radiology , vol.190 , pp. 223-225
    • Liberman, L.1    Evans, W.P.2    Dershaw, D.D.3
  • 17
    • 0030774099 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Comparison of 14- and 11-gauge Mammotome probe performance and complication rates
    • Burbank F. Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 1997;63:988-995.
    • (1997) Am Surg , vol.63 , pp. 988-995
    • Burbank, F.1
  • 18
    • 1542264000 scopus 로고    scopus 로고
    • Stereotactic 11-gauge vacuum-assisted breast biopsy: Influence of number of specimens on diagnostic accuracy
    • Lomoschitz FM, Helbich TH, Rudas M, et al. Stereotactic 11-gauge vacuum-assisted breast biopsy: influence of number of specimens on diagnostic accuracy. Radiology 2004;232:897-903.
    • (2004) Radiology , vol.232 , pp. 897-903
    • Lomoschitz, F.M.1    Helbich, T.H.2    Rudas, M.3
  • 19
    • 0031055857 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    • Burbank F. Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with directional, vacuum-assisted biopsy. Radiology 1997;202:843-847.
    • (1997) Radiology , vol.202 , pp. 843-847
    • Burbank, F.1
  • 20
    • 0031050910 scopus 로고    scopus 로고
    • Cost-effectiveness of stereotactic core needle biopsy: Analysis by means of mammographic findings
    • Lee CH, Egglin TK, Philpotts L, Mainiero MB, Torino I. Cost-effectiveness of stereotactic core needle biopsy: analysis by means of mammographic findings. Radiology 1997;202:849-854.
    • (1997) Radiology , vol.202 , pp. 849-854
    • Lee, C.H.1    Egglin, T.K.2    Philpotts, L.3    Mainiero, M.B.4    Torino, I.5
  • 22
    • 0030876771 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device
    • Meyer JE, Smith DN, DiPiro PJ, et al. Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device. Radiology 1997;204:575-576.
    • (1997) Radiology , vol.204 , pp. 575-576
    • Meyer, J.E.1    Smith, D.N.2    Dipiro, P.J.3
  • 23
    • 0030955333 scopus 로고    scopus 로고
    • Stereotactic breast biopsy as an alternative to excisional biopsy
    • Park ST, Galbo C, Ghosh BC. Stereotactic breast biopsy as an alternative to excisional biopsy. World J Surg 1997;21:794-798.
    • (1997) World J Surg , vol.21 , pp. 794-798
    • Park, S.T.1    Galbo, C.2    Ghosh, B.C.3
  • 24
  • 25
    • 0031751854 scopus 로고    scopus 로고
    • Biopsy of breast microcalcifications using an 11-gauge directional vacuum-assisted device
    • Reynolds HE, Poon CM, Goulet RJ, Lazaridis CL. Biopsy of breast microcalcifications using an 11-gauge directional vacuum-assisted device. AJR Am J Roentgenol 1998;171:611-613.
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 611-613
    • Reynolds, H.E.1    Poon, C.M.2    Goulet, R.J.3    Lazaridis, C.L.4
  • 26
    • 0033030531 scopus 로고    scopus 로고
    • Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun
    • Philpotts LE, Shaheen NA, Carter D, Lange RC, Lee CH. Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun. AJR Am J Roentgenol 1999;172:683-687.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 683-687
    • Philpotts, L.E.1    Shaheen, N.A.2    Carter, D.3    Lange, R.C.4    Lee, C.H.5
  • 27
    • 0035174108 scopus 로고    scopus 로고
    • Mammotome core biopsy for mammary microcalcification: Analysis of 160 biopsies from 142 women with surgical and radiologic followup
    • Cangiarella J, Waisman J, Symmans WF, et al. Mammotome core biopsy for mammary microcalcification: analysis of 160 biopsies from 142 women with surgical and radiologic followup. Cancer 2001;91:173-177.
    • (2001) Cancer , vol.91 , pp. 173-177
    • Cangiarella, J.1    Waisman, J.2    Symmans, W.F.3
  • 29
    • 0035049017 scopus 로고    scopus 로고
    • Does exhaustive search for microcalcification improve diagnostic yield in stereotactic core needle breast biopsies?
    • Grimes MM, Karageorge LS, Hogge JP. Does exhaustive search for microcalcification improve diagnostic yield in stereotactic core needle breast biopsies? Mod Pathol 2001;14:350-353.
    • (2001) Mod Pathol , vol.14 , pp. 350-353
    • Grimes, M.M.1    Karageorge, L.S.2    Hogge, J.P.3
  • 30
    • 0034766027 scopus 로고    scopus 로고
    • Biopsy of amorphous breast calcifications: Pathologic outcome and yield at stereotactic biopsy
    • Berg WA, Arnoldus CL, Teferra E, Bhargavan M. Biopsy of amorphous breast calcifications: pathologic outcome and yield at stereotactic biopsy. Radiology 2001;221:495-503.
    • (2001) Radiology , vol.221 , pp. 495-503
    • Berg, W.A.1    Arnoldus, C.L.2    Teferra, E.3    Bhargavan, M.4
  • 31
    • 0036511204 scopus 로고    scopus 로고
    • Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognizable by ultrasonography
    • Apesteguia L, Mellado M, Saenz J, Cordero JL, Reparaz B, De Miguel C. Vacuum-assisted breast biopsy on digital stereotaxic table of nonpalpable lesions non-recognizable by ultrasonography. Eur Radiol 2002;12:638-645.
    • (2002) Eur Radiol , vol.12 , pp. 638-645
    • Apesteguia, L.1    Mellado, M.2    Saenz, J.3    Cordero, J.L.4    Reparaz, B.5    De Miguel, C.6
  • 32
    • 0036721251 scopus 로고    scopus 로고
    • To excise or to sample the mammographie target: What is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy?
    • Liberman L, Kaplan JB, Morris EA, Abramson AE, Menell JH, Dershaw DD. To excise or to sample the mammographie target: what is the goal of stereotactic 11-gauge vacuum-assisted breast biopsy? AJR Am J Roentgenol 2002;179:679-683.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 679-683
    • Liberman, L.1    Kaplan, J.B.2    Morris, E.A.3    Abramson, A.E.4    Menell, J.H.5    Dershaw, D.D.6
  • 33
    • 2342570972 scopus 로고    scopus 로고
    • Stereotactic core-needle biopsy of non-mass calcifications: Outcome and accuracy at long-term follow-up
    • Han BK, Choe YH, Ko YH, Nam SJ, Kim JH, Yang JH. Stereotactic core-needle biopsy of non-mass calcifications: outcome and accuracy at long-term follow-up. Korean J Radiol 2003;4:217-223.
    • (2003) Korean J Radiol , vol.4 , pp. 217-223
    • Han, B.K.1    Choe, Y.H.2    Ko, Y.H.3    Nam, S.J.4    Kim, J.H.5    Yang, J.H.6
  • 34
    • 0347985320 scopus 로고    scopus 로고
    • Stereotactic vacuum-assisted breast biopsy in 2874 patients
    • Kettritz U, Rotter K, Schreer I, et al. Stereotactic vacuum-assisted breast biopsy in 2874 patients. Cancer 2004;100:245-251.
    • (2004) Cancer , vol.100 , pp. 245-251
    • Kettritz, U.1    Rotter, K.2    Schreer, I.3
  • 35
    • 0025179426 scopus 로고
    • Stereotactic breast biopsy with a biopsy gun
    • Parker SH, Lovin JD, Jobe WE, et al. Stereotactic breast biopsy with a biopsy gun. Radiology 1990;176:741-747.
    • (1990) Radiology , vol.176 , pp. 741-747
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.E.3
  • 38
    • 0029759194 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Improved tissue harvesting with the Mammotome
    • Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996;62:738-744.
    • (1996) Am Surg , vol.62 , pp. 738-744
    • Burbank, F.1    Parker, S.H.2    Fogarty, T.J.3
  • 39
    • 0034088262 scopus 로고    scopus 로고
    • Cost-effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy
    • Liberman L, Sama MP. Cost-effectiveness of stereotactic 11-gauge directional vacuum-assisted breast biopsy. AJR Am J Roentgenol 2000;175:53-58.
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 53-58
    • Liberman, L.1    Sama, M.P.2
  • 40
    • 0036189591 scopus 로고    scopus 로고
    • Diagnostic strategies in non-palpable breast lesions
    • Pijnappel RM, Peeters PH, van den Donk M, et al. Diagnostic strategies in non-palpable breast lesions. Eur J Cancer 2002;38:550-555.
    • (2002) Eur J Cancer , vol.38 , pp. 550-555
    • Pijnappel, R.M.1    Peeters, P.H.2    Van Den Donk, M.3
  • 41
    • 0034671616 scopus 로고    scopus 로고
    • Imaging-histologic discordance at percutaneous breast biopsy: An indicator of missed cancer
    • Liberman L, Drotman M, Morris EA, et al. Imaging-histologic discordance at percutaneous breast biopsy: an indicator of missed cancer. Cancer 2000;89:2538-2546.
    • (2000) Cancer , vol.89 , pp. 2538-2546
    • Liberman, L.1    Drotman, M.2    Morris, E.A.3
  • 42
    • 0036893114 scopus 로고    scopus 로고
    • Stereotactic 11-gauge vacuum-assisted breast biopsy: A validation study
    • Pfarl G, Helbich TH, Riedl CC, et al. Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR Am J Roentgenol 2002;179:1503-l5~07.
    • (2002) AJR Am J Roentgenol , vol.179
    • Pfarl, G.1    Helbich, T.H.2    Riedl, C.C.3
  • 43
    • 0023685743 scopus 로고
    • Clinically occult, noncalcified breast cancer: Serial radiologic-pathologic correlation in 27 cases
    • Stomper PC, Davis SP, Weidner N, Meyer JE. Clinically occult, noncalcified breast cancer: serial radiologic-pathologic correlation in 27 cases. Radiology 1988;169:621-626.
    • (1988) Radiology , vol.169 , pp. 621-626
    • Stomper, P.C.1    Davis, S.P.2    Weidner, N.3    Meyer, J.E.4
  • 44
    • 0037142174 scopus 로고    scopus 로고
    • Diagnostic accuracy of stereotactic large-core needle biopsy for non-palpable breast disease: Results of a multicenter prospective study with 95% surgical confirmation
    • Verkooijen HM. Diagnostic accuracy of stereotactic large-core needle biopsy for non-palpable breast disease: results of a multicenter prospective study with 95% surgical confirmation. Int J Cancer 2002;99:853-859.
    • (2002) Int J Cancer , vol.99 , pp. 853-859
    • Verkooijen, H.M.1
  • 45
    • 0035144642 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of nonpalpable lesions: Determinants of dtictal carcinoma in situ underestimation rates
    • Jackman RJ, Burbank F, Parker SH, et al. Stereotactic breast biopsy of nonpalpable lesions: determinants of dtictal carcinoma in situ underestimation rates. Radiology 2001;218:497-502.
    • (2001) Radiology , vol.218 , pp. 497-502
    • Jackman, R.J.1    Burbank, F.2    Parker, S.H.3
  • 46
    • 0036311741 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia: Can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision?
    • Jackman RJ, Birdwell RL, Ikeda DM. Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision? Radiology 2002;224:548-554.
    • (2002) Radiology , vol.224 , pp. 548-554
    • Jackman, R.J.1    Birdwell, R.L.2    Ikeda, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.