메뉴 건너뛰기




Volumn 205, Issue 2, 1997, Pages 407-415

Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization

Author keywords

Biopsies, technology; Breast neoplasms, diagnosis; Breast, biopsy; Stereotaxis

Indexed keywords

ADULT; AGED; ARTICLE; BREAST BIOPSY; BREAST TUMOR; CONTROLLED STUDY; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MAMMOGRAPHY; PRIORITY JOURNAL; STEREOTAXIC SURGERY; STEREOTAXIS; TUMOR LOCALIZATION;

EID: 0030723987     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.205.2.9356621     Document Type: Article
Times cited : (174)

References (18)
  • 1
    • 1842403386 scopus 로고    scopus 로고
    • RDOG5: Stereotactic fine needle aspiration (FNA) and core needle biopsy (CNB) in the work-up of lesions detected by mammography - Insufficiency sample rate across multiple centers in a nationwide trial
    • Dallas, Tex
    • Pisano ED, Tsimikas J, Fajardo L, et al. RDOG5: stereotactic fine needle aspiration (FNA) and core needle biopsy (CNB) in the work-up of lesions detected by mammography - insufficiency sample rate across multiple centers in a nationwide trial. Presented at the 27th National Conference on Breast Cancer, Dallas, Tex, 1996.
    • (1996) 27th National Conference on Breast Cancer
    • Pisano, E.D.1    Tsimikas, J.2    Fajardo, L.3
  • 2
    • 0025179426 scopus 로고
    • Stereotactic breast biopsy with a biopsy gun
    • Parker SH, Lovin JD, Jobe WE, et al. Stereotactic breast biopsy with a biopsy gun. Radiology 1990; 176:741-747.
    • (1990) Radiology , vol.176 , pp. 741-747
    • Parker, S.H.1    Lovin, J.D.2    Jobe, W.E.3
  • 3
    • 85056195407 scopus 로고
    • Needle core biopsy of mammographic lesions
    • Dershaw DD. Needle core biopsy of mammographic lesions (letter). AJR 1995; 164:260.
    • (1995) AJR , vol.164 , pp. 260
    • Dershaw, D.D.1
  • 4
    • 0028210173 scopus 로고
    • Needle core biopsy of mammographic lesions
    • Sullivan DC. Needle core biopsy of mammographic lesions (letter). AJR 1994; 162:601-608.
    • (1994) AJR , vol.162 , pp. 601-608
    • Sullivan, D.C.1
  • 5
    • 0026763044 scopus 로고
    • Stereotaxic core biopsy of breast lesions
    • Dronkers DJ. Stereotaxic core biopsy of breast lesions. Radiology 1992; 183:631-634.
    • (1992) Radiology , vol.183 , pp. 631-634
    • Dronkers, D.J.1
  • 6
    • 0028506316 scopus 로고
    • Stereotactic core needle biopsy of mammographic breast lesions as a viable alternative to surgical biopsy
    • Mikhail RA, Nathan RC, Weiss M, et al. Stereotactic core needle biopsy of mammographic breast lesions as a viable alternative to surgical biopsy. Ann Surg Oncol 1994; 1:363-367.
    • (1994) Ann Surg Oncol , vol.1 , pp. 363-367
    • Mikhail, R.A.1    Nathan, R.C.2    Weiss, M.3
  • 7
    • 0029759194 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Improved tissue harvesting with the Mammotome
    • Burbank F, Parker SH, Fogarty TJ. Stereotactic breast biopsy: improved tissue harvesting with the Mammotome. Am Surg 1996; 62:128-150.
    • (1996) Am Surg , vol.62 , pp. 128-150
    • Burbank, F.1    Parker, S.H.2    Fogarty, T.J.3
  • 8
    • 0030962684 scopus 로고    scopus 로고
    • Mammographic findings after 14-gauge automated needle and 14-gauge directional vacuum-assisted stereotactic breast biopsy
    • Burbank F. Mammographic findings after 14-gauge automated needle and 14-gauge directional vacuum-assisted stereotactic breast biopsy. Radiology 1997; 204:153-156.
    • (1997) Radiology , vol.204 , pp. 153-156
    • Burbank, F.1
  • 9
    • 1842339750 scopus 로고    scopus 로고
    • Frequency of excisional breast biopsy with clear margins with the Biopsys Mammotome
    • Burbank F. Frequency of excisional breast biopsy with clear margins with the Biopsys Mammotome (abstr). Mini Invasive Ther Allied Technol 1996; 5(suppl):39.
    • (1996) Mini Invasive Ther Allied Technol , vol.5 , Issue.SUPPL. , pp. 39
    • Burbank, F.1
  • 10
    • 0030774099 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Comparison of 14- and 11-gauge Mammotome probe performance and complication rates
    • in press
    • Burbank F. Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates. Am Surg 1997 (in press).
    • (1997) Am Surg
    • Burbank, F.1
  • 11
    • 0029894202 scopus 로고    scopus 로고
    • Stereotactic breast biopsy: Its history, its present, and its future
    • Burbank F. Stereotactic breast biopsy: its history, its present, and its future. Am Surg 1996; 62:128-150.
    • (1996) Am Surg , vol.62 , pp. 128-150
    • Burbank, F.1
  • 13
    • 0028071742 scopus 로고
    • Epithelial displacement in surgical breast specimens following needling procedures
    • Youngson BJ, Cranor M, Rosen PP. Epithelial displacement in surgical breast specimens following needling procedures. Am J Surg Pathol 1994; 18:896-903.
    • (1994) Am J Surg Pathol , vol.18 , pp. 896-903
    • Youngson, B.J.1    Cranor, M.2    Rosen, P.P.3
  • 14
    • 0031055857 scopus 로고    scopus 로고
    • Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with a directional, vacuum-assisted biopsy instrument
    • Burbank F. Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with a directional, vacuum-assisted biopsy instrument. Radiology 1997; 202:843-847.
    • (1997) Radiology , vol.202 , pp. 843-847
    • Burbank, F.1
  • 15
    • 0027934580 scopus 로고
    • Stereotaxic large-core needle biopsy of 450 nonpalpable breast lesions with surgical correlation in lesions with cancer or atypical hyperplasia
    • Jackman RJ, Nowels KW, Shepard MJ, Finkelstein SI, Marzoni FA. Stereotaxic large-core needle biopsy of 450 nonpalpable breast lesions with surgical correlation in lesions with cancer or atypical hyperplasia. Radiology 1994; 193:91-95.
    • (1994) Radiology , vol.193 , pp. 91-95
    • Jackman, R.J.1    Nowels, K.W.2    Shepard, M.J.3    Finkelstein, S.I.4    Marzoni, F.A.5
  • 16
    • 0028909883 scopus 로고
    • Atypical ductal hyperplasia diagnosed at stereotaxic core biopsy of breast lesions: An indication for surgical biopsy
    • Liberman L, Cohen MA, Dershaw DD, Abramson AF, Hann LE, Rosen PP. Atypical ductal hyperplasia diagnosed at stereotaxic core biopsy of breast lesions: an indication for surgical biopsy. AJR 1995; 164:1111-1113.
    • (1995) AJR , vol.164 , pp. 1111-1113
    • Liberman, L.1    Cohen, M.A.2    Dershaw, D.D.3    Abramson, A.F.4    Hann, L.E.5    Rosen, P.P.6
  • 17
    • 0028877550 scopus 로고
    • Stereotaxic core biopsy of breast carcinoma: Accuracy at predicting invasion
    • Liberman L, Dershaw DD, Rosen PP, et al. Stereotaxic core biopsy of breast carcinoma: accuracy at predicting invasion. Radiology 1995; 194:379-381.
    • (1995) Radiology , vol.194 , pp. 379-381
    • Liberman, L.1    Dershaw, D.D.2    Rosen, P.P.3
  • 18
    • 0030787433 scopus 로고    scopus 로고
    • Atypical ductal hyperplasia diagnosed with stereotactic biopsy: Improved reliability with 14-gauge, directional vacuum-assisted breast biopsy
    • Jackman RJ, Burbank F, Parker SH, et al. Atypical ductal hyperplasia diagnosed with stereotactic biopsy: improved reliability with 14-gauge, directional vacuum-assisted breast biopsy. Radiology 1997; 204:485-488.
    • (1997) Radiology , vol.204 , pp. 485-488
    • Jackman, R.J.1    Burbank, F.2    Parker, S.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.