National diabetes fact sheet: general information and national estimates on diabetes in the United States. Atlanta, GA: Centers for Disease Control and Prevention, US Department of Health and Human Services; 2005.
-
-
-
-
2
-
-
0043244907
-
Economic costs of diabetes in the US in 2002
-
Petersen M. Economic costs of diabetes in the US in 2002. Diabetes Care 26 3 (2003) 917-932
-
(2003)
Diabetes Care
, vol.26
, Issue.3
, pp. 917-932
-
-
Petersen, M.1
-
3
-
-
0022269013
-
Diabetes-mellitus-biosensors for research and management
-
Turner A.P.F., and Pickup J.C. Diabetes-mellitus-biosensors for research and management. Biosensors 1 1 (1985) 85-115
-
(1985)
Biosensors
, vol.1
, Issue.1
, pp. 85-115
-
-
Turner, A.P.F.1
Pickup, J.C.2
-
4
-
-
0027374458
-
The diabetes control and complications trial-implications for policy and practice
-
Lasker R.D. The diabetes control and complications trial-implications for policy and practice. New Engl J Med 329 14 (1993) 1035-1036
-
(1993)
New Engl J Med
, vol.329
, Issue.14
, pp. 1035-1036
-
-
Lasker, R.D.1
-
5
-
-
0030635582
-
American diabetes association: clinical practice recommendations 1997-introduction
-
American diabetes association: clinical practice recommendations 1997-introduction. Diabetes Care 20 (1997) S1
-
(1997)
Diabetes Care
, vol.20
-
-
-
6
-
-
3142783673
-
Tests of glycemia in diabetes
-
Tests of glycemia in diabetes. Diabetes Care 25 90001 (2002) 97S-99S
-
(2002)
Diabetes Care
, vol.25
, Issue.90001
-
-
-
7
-
-
0036365048
-
Treatment issues in type 1 diabetes
-
Bloomgarden Z.T. Treatment issues in type 1 diabetes. Diabetes Care 25 1 (2002) 230-236
-
(2002)
Diabetes Care
, vol.25
, Issue.1
, pp. 230-236
-
-
Bloomgarden, Z.T.1
-
8
-
-
0025849027
-
Fundamentals of glucose sensors
-
Fischer U. Fundamentals of glucose sensors. Diabetes Med 8 4 (1991) 309-321
-
(1991)
Diabetes Med
, vol.8
, Issue.4
, pp. 309-321
-
-
Fischer, U.1
-
9
-
-
0030175963
-
Glucose monitoring: state of the art and future possibilities
-
Wilkins E., and Atanasov P. Glucose monitoring: state of the art and future possibilities. Med Eng Phys 18 4 (1996) 273-288
-
(1996)
Med Eng Phys
, vol.18
, Issue.4
, pp. 273-288
-
-
Wilkins, E.1
Atanasov, P.2
-
10
-
-
0141516162
-
New developments in home glucose monitoring: minimizing the pain
-
Gabbay R. New developments in home glucose monitoring: minimizing the pain. Can J Diabetes 27 3 (2003) 371-376
-
(2003)
Can J Diabetes
, vol.27
, Issue.3
, pp. 371-376
-
-
Gabbay, R.1
-
11
-
-
0033579205
-
Noninvasive glucose monitoring-comprehensive clinical results
-
Tamada J.A., Garg S., Jovanovic L., Pitzer K.R., Fermi S., and Potts R.O. Noninvasive glucose monitoring-comprehensive clinical results. JAMA 282 19 (1999) 1839-1844
-
(1999)
JAMA
, vol.282
, Issue.19
, pp. 1839-1844
-
-
Tamada, J.A.1
Garg, S.2
Jovanovic, L.3
Pitzer, K.R.4
Fermi, S.5
Potts, R.O.6
-
12
-
-
0035345431
-
Detection of hypoglycemia with the GlucoWatch biographer
-
Pitzer K.R., Desai S., Dunn T., Edelman S., Jayalakshmi Y., Kennedy J., et al. Detection of hypoglycemia with the GlucoWatch biographer. Diabetes Care 24 5 (2001) 881-885
-
(2001)
Diabetes Care
, vol.24
, Issue.5
, pp. 881-885
-
-
Pitzer, K.R.1
Desai, S.2
Dunn, T.3
Edelman, S.4
Jayalakshmi, Y.5
Kennedy, J.6
-
13
-
-
34249807962
-
-
Cygnus Customer Service Representative. Telephone Conversation, 2004.
-
-
-
-
14
-
-
34249814360
-
-
Press Release: FDA Clears New Diabetes Device for Marketing. US Department of Health and Human Services. US Food and Drug Administration, 2003.
-
-
-
-
15
-
-
34249817623
-
-
Medtronic MiniMed. REAL-time continuous glucose monitoring. Northridge, CA: Medtronic MiniMed, Inc. [Company Product Information Web Page] 2006 [cited 2006]. Available from: 〈http://www.minimed.com/products/insulinpumps/components/cgm.html〉.
-
-
-
-
16
-
-
34249789618
-
-
Medtronic MiniMed Customer Service Representative. Telephone Conversation, Northridge, CA, 2006.
-
-
-
-
17
-
-
0242363717
-
A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes
-
Feldman B., Brazg R., Schwartz W., and Weinstein R. A continuous glucose sensor based on wired enzyme technology-results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther 5 (2003) 769-779
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 769-779
-
-
Feldman, B.1
Brazg, R.2
Schwartz, W.3
Weinstein, R.4
-
18
-
-
34249816199
-
The free-style navigator™ continuous glucose monitor: Complete results from a home-use trial
-
Feldman B. The free-style navigator™ continuous glucose monitor: Complete results from a home-use trial. Diabetes Technol Ther 6 2 (2004) 218
-
(2004)
Diabetes Technol Ther
, vol.6
, Issue.2
, pp. 218
-
-
Feldman, B.1
-
19
-
-
27644556801
-
A review of continuous glucose monitoring technology
-
Klonoff D.C. A review of continuous glucose monitoring technology. Diabetes Technol Ther 7 5 (2005) 770-775
-
(2005)
Diabetes Technol Ther
, vol.7
, Issue.5
, pp. 770-775
-
-
Klonoff, D.C.1
-
20
-
-
0034237244
-
Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients
-
Hullegie L.M., Lutgers H.L., Dullaart R.P.F., Sluiter W.J., Wientjes K.J., Schoonen A.J.M., et al. Effects of glucose and insulin levels on adipose tissue glucose measurement by microdialysis probes retained for three weeks in Type 1 diabetic patients. Netherlands J Med 57 1 (2000) 13-19
-
(2000)
Netherlands J Med
, vol.57
, Issue.1
, pp. 13-19
-
-
Hullegie, L.M.1
Lutgers, H.L.2
Dullaart, R.P.F.3
Sluiter, W.J.4
Wientjes, K.J.5
Schoonen, A.J.M.6
-
21
-
-
0034237793
-
Microdialysis measurement of glucose in subcutaneous adipose tissue up to three weeks in Type 1 diabetic patients
-
Lutgers H.L., Hullegie L.M., Hoogenberg K., Sluiter W.J., Dullaart R.P.F., Wientjes K.J., et al. Microdialysis measurement of glucose in subcutaneous adipose tissue up to three weeks in Type 1 diabetic patients. Netherlands J Med 57 1 (2000) 7-12
-
(2000)
Netherlands J Med
, vol.57
, Issue.1
, pp. 7-12
-
-
Lutgers, H.L.1
Hullegie, L.M.2
Hoogenberg, K.3
Sluiter, W.J.4
Dullaart, R.P.F.5
Wientjes, K.J.6
-
22
-
-
12444301362
-
Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
-
Gebhart S., Faupel M., Fowler R., Kapsner C., Lincoln D., McGee V., et al. Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum. Diabetes Technol Ther 5 2 (2003) 159-166
-
(2003)
Diabetes Technol Ther
, vol.5
, Issue.2
, pp. 159-166
-
-
Gebhart, S.1
Faupel, M.2
Fowler, R.3
Kapsner, C.4
Lincoln, D.5
McGee, V.6
-
23
-
-
1442324399
-
Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes
-
Garg S.K., Schwartz S., and Edelman S.V. Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. Diabetes Care 27 3 (2004) 734-738
-
(2004)
Diabetes Care
, vol.27
, Issue.3
, pp. 734-738
-
-
Garg, S.K.1
Schwartz, S.2
Edelman, S.V.3
-
24
-
-
0036835883
-
GlucoWatch approved for children with diabetes
-
GlucoWatch approved for children with diabetes. FDA Consum 36 6 (2002) 6
-
(2002)
FDA Consum
, vol.36
, Issue.6
, pp. 6
-
-
-
25
-
-
0032882086
-
Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes
-
Garg S.K., Potts R.O., Ackerman N.R., Fermi S.J., Tamada J.A., and Chase H.P. Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes. Diabetes Care 22 10 (1999) 1708-1714
-
(1999)
Diabetes Care
, vol.22
, Issue.10
, pp. 1708-1714
-
-
Garg, S.K.1
Potts, R.O.2
Ackerman, N.R.3
Fermi, S.J.4
Tamada, J.A.5
Chase, H.P.6
-
26
-
-
34249776387
-
-
Medtronic MiniMed Customer Service Representative. Telephone Conversation, Northridge, CA, 2007.
-
-
-
-
27
-
-
0007458281
-
Biosensors
-
von Recum A.F. (Ed), Taylor & Francis, Philadelphia
-
Reichert W.M., and Sharkawy A.A. Biosensors. In: von Recum A.F. (Ed). Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials (1999), Taylor & Francis, Philadelphia 439-459
-
(1999)
Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials
, pp. 439-459
-
-
Reichert, W.M.1
Sharkawy, A.A.2
-
28
-
-
0033974139
-
Problems associated with subcutaneously implanted glucose sensors
-
Gerritsen M. Problems associated with subcutaneously implanted glucose sensors. Diabetes Care 23 2 (2000) 143-145
-
(2000)
Diabetes Care
, vol.23
, Issue.2
, pp. 143-145
-
-
Gerritsen, M.1
-
29
-
-
4243776889
-
Materials considerations in the selection, performance and adhesion of polymeric encapsulants for implantable sensors
-
Williams D.F. (Ed)
-
Reichert W.M., and Saavedra S.S. Materials considerations in the selection, performance and adhesion of polymeric encapsulants for implantable sensors. In: Williams D.F. (Ed). Science and technology-a comprehensive treatment (1992) 303-343
-
(1992)
Science and technology-a comprehensive treatment
, pp. 303-343
-
-
Reichert, W.M.1
Saavedra, S.S.2
-
30
-
-
0034157284
-
Characterization of implantable biosensor membrane biofouling
-
Wisniewski N., Moussy F., and Reichert W.M. Characterization of implantable biosensor membrane biofouling. Fresenius J Anal Chem 366 6-7 (2000) 611-621
-
(2000)
Fresenius J Anal Chem
, vol.366
, Issue.6-7
, pp. 611-621
-
-
Wisniewski, N.1
Moussy, F.2
Reichert, W.M.3
-
31
-
-
0033911295
-
Methods for reducing biosensor membrane biofouling
-
Wisniewski N., and Reichert M. Methods for reducing biosensor membrane biofouling. Colloids Surf B-Biointerfaces 18 3-4 (2000) 197-219
-
(2000)
Colloids Surf B-Biointerfaces
, vol.18
, Issue.3-4
, pp. 197-219
-
-
Wisniewski, N.1
Reichert, M.2
-
32
-
-
0033970025
-
A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration
-
Updike S.J., Shults M.C., Gilligan B.J., and Rhodes R.K. A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. Diabetes Care 23 2 (2000) 208-214
-
(2000)
Diabetes Care
, vol.23
, Issue.2
, pp. 208-214
-
-
Updike, S.J.1
Shults, M.C.2
Gilligan, B.J.3
Rhodes, R.K.4
-
33
-
-
0031555495
-
Engineering the tissue which encapsulates subcutaneous implants. 1. Diffusion properties
-
Sharkawy A.A., Klitzman B., Truskey G.A., and Reichert W.M. Engineering the tissue which encapsulates subcutaneous implants. 1. Diffusion properties. J Biomed Mater Res 37 3 (1997) 401-412
-
(1997)
J Biomed Mater Res
, vol.37
, Issue.3
, pp. 401-412
-
-
Sharkawy, A.A.1
Klitzman, B.2
Truskey, G.A.3
Reichert, W.M.4
-
34
-
-
0032527092
-
Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties
-
Sharkawy A.A., Klitzman B., Truskey G.A., and Reichert W.M. Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties. J Biomed Mater Res 40 4 (1998) 586-597
-
(1998)
J Biomed Mater Res
, vol.40
, Issue.4
, pp. 586-597
-
-
Sharkawy, A.A.1
Klitzman, B.2
Truskey, G.A.3
Reichert, W.M.4
-
35
-
-
0032527066
-
Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times
-
Sharkawy A.A., Klitzman B., Truskey G.A., and Reichert W.M. Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times. J Biomed Mater Res 40 4 (1998) 598-605
-
(1998)
J Biomed Mater Res
, vol.40
, Issue.4
, pp. 598-605
-
-
Sharkawy, A.A.1
Klitzman, B.2
Truskey, G.A.3
Reichert, W.M.4
-
36
-
-
0034670180
-
Biomaterial-microvasculature interactions
-
Sieminski A.L., and Gooch K.J. Biomaterial-microvasculature interactions. Biomaterials 21 22 (2000) 2233-2241
-
(2000)
Biomaterials
, vol.21
, Issue.22
, pp. 2233-2241
-
-
Sieminski, A.L.1
Gooch, K.J.2
-
37
-
-
34249805751
-
Biomaterials with tightly controlled pore size that promote vascular in-growth
-
Marshall A.J., Irvin C.A., Barker T., Sage E.H., Hauch K.D., and Ratner B.D. Biomaterials with tightly controlled pore size that promote vascular in-growth. Abstr Pap Am Chem Soc 228 (2004) U386
-
(2004)
Abstr Pap Am Chem Soc
, vol.228
-
-
Marshall, A.J.1
Irvin, C.A.2
Barker, T.3
Sage, E.H.4
Hauch, K.D.5
Ratner, B.D.6
-
38
-
-
10644233978
-
In vitro characterization of vascular endothelial growth factor and dexamethasone releasing hydrogels for implantable probe coatings
-
Norton L.W., Tegnell E., Toporek S.S., and Reichert W.M. In vitro characterization of vascular endothelial growth factor and dexamethasone releasing hydrogels for implantable probe coatings. Biomaterials 26 16 (2005) 3285-3297
-
(2005)
Biomaterials
, vol.26
, Issue.16
, pp. 3285-3297
-
-
Norton, L.W.1
Tegnell, E.2
Toporek, S.S.3
Reichert, W.M.4
-
39
-
-
4644297442
-
Enhancement of implantable glucose sensor function in vivo using gene transfer-induced neovascularization
-
Klueh U., Dorsky D.I., and Kreutzer D.L. Enhancement of implantable glucose sensor function in vivo using gene transfer-induced neovascularization. Biomaterials 26 10 (2005) 1155-1163
-
(2005)
Biomaterials
, vol.26
, Issue.10
, pp. 1155-1163
-
-
Klueh, U.1
Dorsky, D.I.2
Kreutzer, D.L.3
-
40
-
-
0028106630
-
Evaluation of a subcutaneous glucose sensor out to 3 months in a dog-model
-
Gilligan B.J., Shults M.C., Rhodes R.K., and Updike S.J. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog-model. Diabetes Care 17 8 (1994) 882-887
-
(1994)
Diabetes Care
, vol.17
, Issue.8
, pp. 882-887
-
-
Gilligan, B.J.1
Shults, M.C.2
Rhodes, R.K.3
Updike, S.J.4
-
41
-
-
0024956219
-
In situ calibration of implanted electrochemical glucose sensors
-
Von Woedtke T., Rebrin K., Fischer U., Abel P., Wilke W., Vogt L., et al. In situ calibration of implanted electrochemical glucose sensors. Biomed Biochim Acta 48 11-12 (1989) 943-952
-
(1989)
Biomed Biochim Acta
, vol.48
, Issue.11-12
, pp. 943-952
-
-
Von Woedtke, T.1
Rebrin, K.2
Fischer, U.3
Abel, P.4
Wilke, W.5
Vogt, L.6
-
42
-
-
29044446594
-
Electrochemical characterization and in vivo biocompatibility of a thick-film printed sensor for continuous in vivo monitoring
-
Voskerician G., Liu C.C., and Anderson J.M. Electrochemical characterization and in vivo biocompatibility of a thick-film printed sensor for continuous in vivo monitoring. IEEE Sensors J 5 6 (2005) 1147-1158
-
(2005)
IEEE Sensors J
, vol.5
, Issue.6
, pp. 1147-1158
-
-
Voskerician, G.1
Liu, C.C.2
Anderson, J.M.3
-
43
-
-
0027746317
-
The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma
-
Kerner W., Kiwit M., Linke B., Keck F.S., Zier H., and Pfeiffer E.F. The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasma. Biosensors Bioelectr 8 9-10 (1993) 473-482
-
(1993)
Biosensors Bioelectr
, vol.8
, Issue.9-10
, pp. 473-482
-
-
Kerner, W.1
Kiwit, M.2
Linke, B.3
Keck, F.S.4
Zier, H.5
Pfeiffer, E.F.6
-
44
-
-
0027770788
-
Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man
-
Pickup J.C., Claremont D.J., and Shaw G.W. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Acta Diabetol 30 3 (1993) 143-148
-
(1993)
Acta Diabetol
, vol.30
, Issue.3
, pp. 143-148
-
-
Pickup, J.C.1
Claremont, D.J.2
Shaw, G.W.3
-
45
-
-
0023760655
-
Long-term stability of electroenzymatic glucose sensors implanted in mice-an update
-
Clark Jr. L.C., Spokane R.B., Homan M.M., Sudan R., and Miller M. Long-term stability of electroenzymatic glucose sensors implanted in mice-an update. ASAIO J 34 (1988) 259-265
-
(1988)
ASAIO J
, vol.34
, pp. 259-265
-
-
Clark Jr., L.C.1
Spokane, R.B.2
Homan, M.M.3
Sudan, R.4
Miller, M.5
-
46
-
-
0024957628
-
Oxygen-tension at the subcutaneous implantation site of glucose sensors
-
Fischer U., Hidde A., Herrmann S., Vonwoedtke T., Rebrin K., and Abel P. Oxygen-tension at the subcutaneous implantation site of glucose sensors. Biomed Biochim Acta 48 11-12 (1989) 965-971
-
(1989)
Biomed Biochim Acta
, vol.48
, Issue.11-12
, pp. 965-971
-
-
Fischer, U.1
Hidde, A.2
Herrmann, S.3
Vonwoedtke, T.4
Rebrin, K.5
Abel, P.6
-
47
-
-
0026320226
-
Application of cell culture toxicity test to the development of implantable biosensors
-
Zhang Y., Bindra D.S., Barrau M.B., and Wilson G.S. Application of cell culture toxicity test to the development of implantable biosensors. Biosensor Bioelectr 6 (1991) 653-661
-
(1991)
Biosensor Bioelectr
, vol.6
, pp. 653-661
-
-
Zhang, Y.1
Bindra, D.S.2
Barrau, M.B.3
Wilson, G.S.4
-
48
-
-
34249790330
-
-
The biocompatibility of materials used in drug containers, medical devices, and implants. In: United States Pharmacopeial Convention, editor. United States pharmacopeia. Rockville, MD: United States Pharmacopeial Convention, 2002. p. 2091-8.
-
-
-
-
49
-
-
34249785137
-
-
Biological evaluation of medical devices-Part 1: Guidance on selection of tests. ISO 10993-1:1992(E). International Organization for Standardization (ISO), 1992.
-
-
-
-
50
-
-
34249806066
-
-
Standard practice for selecting generic biological test methods for materials and devices Designation F 748-98. American Society for Testing and Materials (ASTM), 2001.
-
-
-
-
51
-
-
0026572322
-
Legal requirements for the preclinical toxicological evaluation of biomaterials
-
Leuschner J. Legal requirements for the preclinical toxicological evaluation of biomaterials. Clin Mater 10 1-2 (1992) 51-57
-
(1992)
Clin Mater
, vol.10
, Issue.1-2
, pp. 51-57
-
-
Leuschner, J.1
-
52
-
-
85056038962
-
Testing
-
von Recum A.F. (Ed), Taylor & Francis, Philadelphia
-
Upman P. Testing. In: von Recum A.F. (Ed). Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials (1999), Taylor & Francis, Philadelphia 275-289
-
(1999)
Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials
, pp. 275-289
-
-
Upman, P.1
-
53
-
-
0025689061
-
Application of chronic intravascular blood-glucose sensor in dogs
-
Armour J.C., Lucisano J.Y., McKean B.D., and Gough D.A. Application of chronic intravascular blood-glucose sensor in dogs. Diabetes 39 12 (1990) 1519-1526
-
(1990)
Diabetes
, vol.39
, Issue.12
, pp. 1519-1526
-
-
Armour, J.C.1
Lucisano, J.Y.2
McKean, B.D.3
Gough, D.A.4
-
54
-
-
0028413636
-
Enzymatic glucose sensors-improved long-term performance in vitro and in vivo
-
Updike S.J., Shults M.C., Rhodes R.K., Gilligan B.J., Luebow J.O., and von Heimburg D. Enzymatic glucose sensors-improved long-term performance in vitro and in vivo. ASAIO J 40 (1994) 157-163
-
(1994)
ASAIO J
, vol.40
, pp. 157-163
-
-
Updike, S.J.1
Shults, M.C.2
Rhodes, R.K.3
Gilligan, B.J.4
Luebow, J.O.5
von Heimburg, D.6
-
55
-
-
0026216348
-
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
-
Bindra D.S., Zhang Y.N., Wilson G.S., Sternberg R., Thevenot D.R., Moatti D., et al. Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal Chem 63 17 (1991) 1692-1696
-
(1991)
Anal Chem
, vol.63
, Issue.17
, pp. 1692-1696
-
-
Bindra, D.S.1
Zhang, Y.N.2
Wilson, G.S.3
Sternberg, R.4
Thevenot, D.R.5
Moatti, D.6
-
56
-
-
0036122255
-
Sterilization of enzyme glucose sensors: problems and concepts
-
von Woedtke T., Julich W.D., Hartmann V., Stieber M., and Abel P.U. Sterilization of enzyme glucose sensors: problems and concepts. Biosensors Bioelectr 17 5 (2002) 373-382
-
(2002)
Biosensors Bioelectr
, vol.17
, Issue.5
, pp. 373-382
-
-
von Woedtke, T.1
Julich, W.D.2
Hartmann, V.3
Stieber, M.4
Abel, P.U.5
-
57
-
-
34249806365
-
-
Biological evaluation of medical devices-Part 7: Ethylene oxide sterilization residuals 10993-7. International Organization for Standardization (ISO), 1995.
-
-
-
-
58
-
-
34249813453
-
-
Sterilization and sterility assurance of compendial articles. In: United States Pharmacopeial Convention, editor. United States Pharmacopeia. Rockville, MD: United States Pharmacopeial Convention, 2002. p. 2250-5.
-
-
-
-
59
-
-
0036883638
-
Biosensors for in vivo glucose measurement: can we cross the experimental stage
-
Abel P.U., and von Woedtke T. Biosensors for in vivo glucose measurement: can we cross the experimental stage. Biosensors Bioelectr 17 11-12 (2002) 1059-1070
-
(2002)
Biosensors Bioelectr
, vol.17
, Issue.11-12
, pp. 1059-1070
-
-
Abel, P.U.1
von Woedtke, T.2
-
60
-
-
0029294415
-
Development of a thin membrane glucose sensor using beta-type crystalline chitin for implantable biosensor
-
Ohashi E., and Karube I. Development of a thin membrane glucose sensor using beta-type crystalline chitin for implantable biosensor. J Biotechnol 40 1 (1995) 13-19
-
(1995)
J Biotechnol
, vol.40
, Issue.1
, pp. 13-19
-
-
Ohashi, E.1
Karube, I.2
-
61
-
-
0031845380
-
Wearable microdialysis system for continuous in vivo monitoring of glucose
-
Vering T., Adam S., Drewer H., Dumschat C., Steinkuhl R., Schulze A., et al. Wearable microdialysis system for continuous in vivo monitoring of glucose. Analyst 123 7 (1998) 1605-1609
-
(1998)
Analyst
, vol.123
, Issue.7
, pp. 1605-1609
-
-
Vering, T.1
Adam, S.2
Drewer, H.3
Dumschat, C.4
Steinkuhl, R.5
Schulze, A.6
-
62
-
-
0026593281
-
Subcutaneous glucose monitoring by means of electrochemical sensors-fiction or reality
-
Rebrin K., Fischer U., Vondorsche H.H., Von Woetke T., Abel P., and Brunstein E. Subcutaneous glucose monitoring by means of electrochemical sensors-fiction or reality. J Biomed Eng 14 1 (1992) 33-40
-
(1992)
J Biomed Eng
, vol.14
, Issue.1
, pp. 33-40
-
-
Rebrin, K.1
Fischer, U.2
Vondorsche, H.H.3
Von Woetke, T.4
Abel, P.5
Brunstein, E.6
-
63
-
-
0022060018
-
Biocompatibility test procedures for materials evaluation in vitro. 2. Objective methods of toxicity assessment
-
Johnson H.J., Northup S.J., Seagraves P.A., Atallah M., Garvin P.J., Lin L., et al. Biocompatibility test procedures for materials evaluation in vitro. 2. Objective methods of toxicity assessment. J Biomed Mater Res 19 5 (1985) 489-508
-
(1985)
J Biomed Mater Res
, vol.19
, Issue.5
, pp. 489-508
-
-
Johnson, H.J.1
Northup, S.J.2
Seagraves, P.A.3
Atallah, M.4
Garvin, P.J.5
Lin, L.6
-
64
-
-
0028064448
-
Antibody-response in rats against nontoxic glucose sensor membranes tested in cell-culture
-
Ziegler M., Schlosser M., Abel P., and Ziegler B. Antibody-response in rats against nontoxic glucose sensor membranes tested in cell-culture. Biomaterials 15 10 (1994) 859-864
-
(1994)
Biomaterials
, vol.15
, Issue.10
, pp. 859-864
-
-
Ziegler, M.1
Schlosser, M.2
Abel, P.3
Ziegler, B.4
-
66
-
-
0026546742
-
Towards continuous glucose monitoring-in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
-
Moattisirat D., Capron E., Poitout V., Reach G., Bindra D.S., Zhang Y., et al. Towards continuous glucose monitoring-in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia 35 3 (1992) 224-230
-
(1992)
Diabetologia
, vol.35
, Issue.3
, pp. 224-230
-
-
Moattisirat, D.1
Capron, E.2
Poitout, V.3
Reach, G.4
Bindra, D.S.5
Zhang, Y.6
-
67
-
-
84908830001
-
Can continuous glucose monitoring be used for the treatment of diabetes
-
Reach G., and Wilson G.S. Can continuous glucose monitoring be used for the treatment of diabetes. Anal Chem 64 6 (1992) A381-A386
-
(1992)
Anal Chem
, vol.64
, Issue.6
-
-
Reach, G.1
Wilson, G.S.2
-
68
-
-
0024044231
-
Transient-response of the two-dimensional glucose sensor
-
Lucisano J.Y., and Gough D.A. Transient-response of the two-dimensional glucose sensor. Anal Chem 60 13 (1988) 1272-1281
-
(1988)
Anal Chem
, vol.60
, Issue.13
, pp. 1272-1281
-
-
Lucisano, J.Y.1
Gough, D.A.2
-
69
-
-
0028279952
-
Amperometric biosensor for in-vivo glucose sensing based on glucose-oxidase immobilized in a redox hydrogel
-
Linke B., Kerner W., Kiwit M., Pishko M., and Heller A. Amperometric biosensor for in-vivo glucose sensing based on glucose-oxidase immobilized in a redox hydrogel. Biosensors Bioelectr 9 2 (1994) 151-158
-
(1994)
Biosensors Bioelectr
, vol.9
, Issue.2
, pp. 151-158
-
-
Linke, B.1
Kerner, W.2
Kiwit, M.3
Pishko, M.4
Heller, A.5
-
70
-
-
0035195605
-
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
-
Gerritsen M., Jansen J.A., Kros A., Vriezema D.M., Sommerdijk N., Nolte R.J.M., et al. Influence of inflammatory cells and serum on the performance of implantable glucose sensors. J Biomed Mater Res 54 1 (2001) 69-75
-
(2001)
J Biomed Mater Res
, vol.54
, Issue.1
, pp. 69-75
-
-
Gerritsen, M.1
Jansen, J.A.2
Kros, A.3
Vriezema, D.M.4
Sommerdijk, N.5
Nolte, R.J.M.6
-
71
-
-
0028922823
-
Engineering the right membranes for electrodes at the biological interface-solvent-cast and electropolymerized
-
Treloar P.H., Christie I.M., and Vadgama P.M. Engineering the right membranes for electrodes at the biological interface-solvent-cast and electropolymerized. Biosensors Bioelectr 10 1-2 (1995) 195-201
-
(1995)
Biosensors Bioelectr
, vol.10
, Issue.1-2
, pp. 195-201
-
-
Treloar, P.H.1
Christie, I.M.2
Vadgama, P.M.3
-
72
-
-
0024644133
-
Membrane filters for the concentration of trace-elements in water-distribution of ion-pairs between membrane-filter and aqueous phases
-
Taguchi S., Inaba T., Nishio M., Hata N., Kasahara I., and Goto K. Membrane filters for the concentration of trace-elements in water-distribution of ion-pairs between membrane-filter and aqueous phases. Analyst 114 4 (1989) 489-492
-
(1989)
Analyst
, vol.114
, Issue.4
, pp. 489-492
-
-
Taguchi, S.1
Inaba, T.2
Nishio, M.3
Hata, N.4
Kasahara, I.5
Goto, K.6
-
73
-
-
0032523526
-
Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration
-
Schmidtke D.W., and Heller A. Accuracy of the one-point in vivo calibration of "wired" glucose oxidase electrodes implanted in jugular veins of rats in periods of rapid rise and decline of the glucose concentration. Anal Chem 70 10 (1998) 2149-2155
-
(1998)
Anal Chem
, vol.70
, Issue.10
, pp. 2149-2155
-
-
Schmidtke, D.W.1
Heller, A.2
-
74
-
-
0028533426
-
In-vitro and in-vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing
-
Moussy F., Jakeway S., Harrison D.J., and Rajotte R.V. In-vitro and in-vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing. Anal Chem 66 22 (1994) 3882-3888
-
(1994)
Anal Chem
, vol.66
, Issue.22
, pp. 3882-3888
-
-
Moussy, F.1
Jakeway, S.2
Harrison, D.J.3
Rajotte, R.V.4
-
75
-
-
0026590041
-
Evaluating in vitro and in vivo, the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor
-
Moattisirat D., Velho G., and Reach G. Evaluating in vitro and in vivo, the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosensors Bioelectr 7 5 (1992) 345-352
-
(1992)
Biosensors Bioelectr
, vol.7
, Issue.5
, pp. 345-352
-
-
Moattisirat, D.1
Velho, G.2
Reach, G.3
-
76
-
-
18044367556
-
Biosensors for real-time in vivo measurements
-
Wilson G.S., and Gifford R. Biosensors for real-time in vivo measurements. Biosensors Bioelectr 20 12 (2005) 2388-2403
-
(2005)
Biosensors Bioelectr
, vol.20
, Issue.12
, pp. 2388-2403
-
-
Wilson, G.S.1
Gifford, R.2
-
77
-
-
0036084627
-
Analyte flux through chronically implanted subcutaneous polyamide membranes differs in humans and rats
-
Wisniewski N., Rajamand N., Adamsson U., Lins P.E., Reichert W.M., Klitzman B., et al. Analyte flux through chronically implanted subcutaneous polyamide membranes differs in humans and rats. Am J Physiol-Endocrinol Metabol 282 6 (2002) E1316-E1323
-
(2002)
Am J Physiol-Endocrinol Metabol
, vol.282
, Issue.6
-
-
Wisniewski, N.1
Rajamand, N.2
Adamsson, U.3
Lins, P.E.4
Reichert, W.M.5
Klitzman, B.6
-
78
-
-
0024731165
-
Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors
-
Ertefai S., and Gough D.A. Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors. J Biomed Eng 11 5 (1989) 362-368
-
(1989)
J Biomed Eng
, vol.11
, Issue.5
, pp. 362-368
-
-
Ertefai, S.1
Gough, D.A.2
-
79
-
-
0032568566
-
Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode
-
Wagner J.G., Schmidtke D.W., Quinn C.P., Fleming T.F., Bernacky B., and Heller A. Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode. Proc Natl Acad Sci USA 95 11 (1998) 6379-6382
-
(1998)
Proc Natl Acad Sci USA
, vol.95
, Issue.11
, pp. 6379-6382
-
-
Wagner, J.G.1
Schmidtke, D.W.2
Quinn, C.P.3
Fleming, T.F.4
Bernacky, B.5
Heller, A.6
-
80
-
-
0022138056
-
Two-dimensional enzyme electrode sensor for glucose
-
Gough D.A., Lucisano J.Y., and Tse P.H.S. Two-dimensional enzyme electrode sensor for glucose. Anal Chem 57 12 (1985) 2351-2357
-
(1985)
Anal Chem
, vol.57
, Issue.12
, pp. 2351-2357
-
-
Gough, D.A.1
Lucisano, J.Y.2
Tse, P.H.S.3
-
81
-
-
0344152813
-
Development of subcutaneous wound oxygen measurement in humans: contributions of Thomas K. Hunt, MD
-
Hopf H.W. Development of subcutaneous wound oxygen measurement in humans: contributions of Thomas K. Hunt, MD. Wound Repair Regeneration 11 6 (2003) 424-430
-
(2003)
Wound Repair Regeneration
, vol.11
, Issue.6
, pp. 424-430
-
-
Hopf, H.W.1
-
82
-
-
0038262699
-
Pump up your knowledge of insulin pumps
-
Fain J.A. Pump up your knowledge of insulin pumps. Nursing 33 6 (2003) 51-53
-
(2003)
Nursing
, vol.33
, Issue.6
, pp. 51-53
-
-
Fain, J.A.1
-
84
-
-
0028439484
-
Ion-Selective membranes with low plasticizer content-electroanalytical characterization and biocompatibility studies
-
Lindner E., Cosofret V.V., Ufer S., Buck R.P., Kao W.J., Neuman M.R., et al. Ion-Selective membranes with low plasticizer content-electroanalytical characterization and biocompatibility studies. J Biomed Mater Res 28 5 (1994) 591-601
-
(1994)
J Biomed Mater Res
, vol.28
, Issue.5
, pp. 591-601
-
-
Lindner, E.1
Cosofret, V.V.2
Ufer, S.3
Buck, R.P.4
Kao, W.J.5
Neuman, M.R.6
-
85
-
-
0020721367
-
In vivo biocompatibility studies. 1. The cage implant system and a biodegradable hydrogel
-
Marchant R., Hiltner A., Hamlin C., Rabinovitch A., Slobodkin R., and Anderson J.M. In vivo biocompatibility studies. 1. The cage implant system and a biodegradable hydrogel. J Biomed Mater Res 17 2 (1983) 301-325
-
(1983)
J Biomed Mater Res
, vol.17
, Issue.2
, pp. 301-325
-
-
Marchant, R.1
Hiltner, A.2
Hamlin, C.3
Rabinovitch, A.4
Slobodkin, R.5
Anderson, J.M.6
-
86
-
-
0002709588
-
The cage implant testing system
-
von Recum A.F. (Ed), Taylor & Francis, Philadelphia
-
Kao W.J., and Anderson J.M. The cage implant testing system. In: von Recum A.F. (Ed). Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials (1999), Taylor & Francis, Philadelphia 659-669
-
(1999)
Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials
, pp. 659-669
-
-
Kao, W.J.1
Anderson, J.M.2
-
87
-
-
0029380449
-
Role for interleukin-4 in foreign-body giant-cell formation on a poly(etherurethane urea) in-vivo
-
Kao W.Y.J., McNally A.K., Hiltner A., and Anderson J.M. Role for interleukin-4 in foreign-body giant-cell formation on a poly(etherurethane urea) in-vivo. J Biomed Mater Res 29 10 (1995) 1267-1275
-
(1995)
J Biomed Mater Res
, vol.29
, Issue.10
, pp. 1267-1275
-
-
Kao, W.Y.J.1
McNally, A.K.2
Hiltner, A.3
Anderson, J.M.4
-
88
-
-
0026112933
-
Foreign-body giant-cells and polyurethane biostability-in vivo correlation of cell-adhesion and surface cracking
-
Zhao Q., Topham N., Anderson J.M., Hiltner A., Lodoen G., and Payet C.R. Foreign-body giant-cells and polyurethane biostability-in vivo correlation of cell-adhesion and surface cracking. J Biomed Mater Res 25 2 (1991) 177-183
-
(1991)
J Biomed Mater Res
, vol.25
, Issue.2
, pp. 177-183
-
-
Zhao, Q.1
Topham, N.2
Anderson, J.M.3
Hiltner, A.4
Lodoen, G.5
Payet, C.R.6
-
89
-
-
0018639351
-
Transparent access chamber for the rat dorsal skin fold
-
Papenfuss H.D., Gross J.F., Intaglietta M., and Treese F.A. Transparent access chamber for the rat dorsal skin fold. Microvasc Res 18 3 (1979) 311-318
-
(1979)
Microvasc Res
, vol.18
, Issue.3
, pp. 311-318
-
-
Papenfuss, H.D.1
Gross, J.F.2
Intaglietta, M.3
Treese, F.A.4
-
90
-
-
34249810698
-
-
Makale MT, Lin JT, Calou RE, Tsai AG, Chen PC, Gough DA. Tissue window chamber system for validation of implanted oxygen sensors, 2003.
-
-
-
-
91
-
-
0036836371
-
The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials
-
Valdes T.I., Kreutzer D., and Moussy F. The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials. J Biomed Mater Res 62 2 (2002) 273-282
-
(2002)
J Biomed Mater Res
, vol.62
, Issue.2
, pp. 273-282
-
-
Valdes, T.I.1
Kreutzer, D.2
Moussy, F.3
-
92
-
-
0348015845
-
Ex ova chick chorioallantoic membrane as a novel in vivo model for testing biosensors
-
Valdes T.I., Klueh U., Kreutzer D., and Moussy F. Ex ova chick chorioallantoic membrane as a novel in vivo model for testing biosensors. J Biomed Mater Res A 67A 1 (2003) 215-223
-
(2003)
J Biomed Mater Res A
, vol.67 A
, Issue.1
, pp. 215-223
-
-
Valdes, T.I.1
Klueh, U.2
Kreutzer, D.3
Moussy, F.4
-
93
-
-
34249807383
-
Protection of research animals
-
von Recum A.F. (Ed), Taylor & Francis, Philadelphia
-
Dennis Jr. M.B. Protection of research animals. In: von Recum A.F. (Ed). Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials (1999), Taylor & Francis, Philadelphia 465-473
-
(1999)
Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials
, pp. 465-473
-
-
Dennis Jr., M.B.1
-
94
-
-
0024270045
-
In vivo characteristics of needle-type glucose sensor-measurements of subcutaneous glucose-concentrations in human volunteers
-
Shichiri M., Yamasaki Y., Nao K., Sekiya M., and Ueda N. In vivo characteristics of needle-type glucose sensor-measurements of subcutaneous glucose-concentrations in human volunteers. Hormone Metabol Res 20 (1988) 17-20
-
(1988)
Hormone Metabol Res
, vol.20
, pp. 17-20
-
-
Shichiri, M.1
Yamasaki, Y.2
Nao, K.3
Sekiya, M.4
Ueda, N.5
-
95
-
-
0342746647
-
Animal selection
-
von Recum A.F. (Ed), Taylor & Francis, Philadelphia
-
Mendenhall H.V. Animal selection. In: von Recum A.F. (Ed). Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials (1999), Taylor & Francis, Philadelphia 475-479
-
(1999)
Handbook of biomaterials evaluation: scientific, technical, and clinical testing of implant materials
, pp. 475-479
-
-
Mendenhall, H.V.1
-
96
-
-
0031727960
-
Saphenous vein puncture for blood sampling of the mouse, rat, hamster, gerbil, guinea pig, ferret and mink
-
Hem A., Smith A.J., and Solberg P. Saphenous vein puncture for blood sampling of the mouse, rat, hamster, gerbil, guinea pig, ferret and mink. Lab Anim 32 4 (1998) 364-368
-
(1998)
Lab Anim
, vol.32
, Issue.4
, pp. 364-368
-
-
Hem, A.1
Smith, A.J.2
Solberg, P.3
-
97
-
-
0018636086
-
Blood-circulation in adipose-tissue
-
Rosell S., and Belfrage E. Blood-circulation in adipose-tissue. Physiol Rev 59 4 (1979) 1078-1104
-
(1979)
Physiol Rev
, vol.59
, Issue.4
, pp. 1078-1104
-
-
Rosell, S.1
Belfrage, E.2
-
98
-
-
0031811284
-
Impaired vasoconstriction of peripheral cutaneous blood flow in Type 1 diabetic patients following food ingestion
-
Rossi M., Lall K., Standfield N., and Dornhorst A. Impaired vasoconstriction of peripheral cutaneous blood flow in Type 1 diabetic patients following food ingestion. Diabetic Med 15 6 (1998) 463-466
-
(1998)
Diabetic Med
, vol.15
, Issue.6
, pp. 463-466
-
-
Rossi, M.1
Lall, K.2
Standfield, N.3
Dornhorst, A.4
-
99
-
-
0028999524
-
High-fructose feeding elicits insulin-resistance without hypertension in normal mongrel dogs
-
Pamiesandreu E., Fiksenolsen M., Rizza R.A., and Romero J.C. High-fructose feeding elicits insulin-resistance without hypertension in normal mongrel dogs. Am J Hypertension 8 7 (1995) 732-738
-
(1995)
Am J Hypertension
, vol.8
, Issue.7
, pp. 732-738
-
-
Pamiesandreu, E.1
Fiksenolsen, M.2
Rizza, R.A.3
Romero, J.C.4
-
100
-
-
34249791838
-
-
Non-mouse models of diabetes complications in cardiovascular and microvascular diseases. National Institutes of Health (NIH). Bethesda, MD [Online government document] 2000 [cited 2007]. Available from: 〈http://grants1.nih.gov/grants/guide/rfa-files/RFA-HL-01-010.html〉.
-
-
-
-
101
-
-
34249814952
-
-
Whitfield J. Fat pigs ape obese humans. Nature. New York, NY [Online journal] 2003 [cited 2003]. Available from: 〈www.nature.com/news〉.
-
-
-
-
102
-
-
0023580011
-
Assessment of subcutaneous glucose-concentration-validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs
-
Fischer U., Ertle R., Abel P., Rebrin K., Brunstein E., Vondorsche H.H., et al. Assessment of subcutaneous glucose-concentration-validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia 30 12 (1987) 940-945
-
(1987)
Diabetologia
, vol.30
, Issue.12
, pp. 940-945
-
-
Fischer, U.1
Ertle, R.2
Abel, P.3
Rebrin, K.4
Brunstein, E.5
Vondorsche, H.H.6
-
103
-
-
0024951885
-
Strategies for calibrating a subcutaneous glucose sensor
-
Velho G., Froguel P., Thevenot D.R., and Reach G. Strategies for calibrating a subcutaneous glucose sensor. Biomed Biochim Acta 48 11-12 (1989) 957-964
-
(1989)
Biomed Biochim Acta
, vol.48
, Issue.11-12
, pp. 957-964
-
-
Velho, G.1
Froguel, P.2
Thevenot, D.R.3
Reach, G.4
-
104
-
-
0033051709
-
Performance of subcutaneously implanted glucose sensors for continuous monitoring
-
Gerritsen M., Jansen J.A., and Lutterman J.A. Performance of subcutaneously implanted glucose sensors for continuous monitoring. Netherlands J Med 54 4 (1999) 167-179
-
(1999)
Netherlands J Med
, vol.54
, Issue.4
, pp. 167-179
-
-
Gerritsen, M.1
Jansen, J.A.2
Lutterman, J.A.3
-
105
-
-
0029287405
-
Design and optimization of a selective subcutaneously implantable glucose electrode based on wired glucose-oxidase
-
Csoregi E., Schmidtke D.W., and Heller A. Design and optimization of a selective subcutaneously implantable glucose electrode based on wired glucose-oxidase. Anal Chem 67 7 (1995) 1240-1244
-
(1995)
Anal Chem
, vol.67
, Issue.7
, pp. 1240-1244
-
-
Csoregi, E.1
Schmidtke, D.W.2
Heller, A.3
-
106
-
-
33646079187
-
A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane
-
Yu B.Z., Long N., Moussy Y., and Moussy F. A long-term flexible minimally-invasive implantable glucose biosensor based on an epoxy-enhanced polyurethane membrane. Biosensors Bioelectr 21 12 (2006) 2275-2282
-
(2006)
Biosensors Bioelectr
, vol.21
, Issue.12
, pp. 2275-2282
-
-
Yu, B.Z.1
Long, N.2
Moussy, Y.3
Moussy, F.4
-
107
-
-
34249777855
-
-
Standard practice for short-term screening of implant materials. Designation F 763-99. American Society for Testing and Materials (ASTM), 2001.
-
-
-
-
108
-
-
0024954424
-
Preparation and validation of implantable electrodes for the measurement of oxygen and glucose
-
Brunstein E., Abel P., Gens A., Eich K., and Vonwoedtke T. Preparation and validation of implantable electrodes for the measurement of oxygen and glucose. Biomed Biochim Acta 48 11-12 (1989) 911-917
-
(1989)
Biomed Biochim Acta
, vol.48
, Issue.11-12
, pp. 911-917
-
-
Brunstein, E.1
Abel, P.2
Gens, A.3
Eich, K.4
Vonwoedtke, T.5
|