메뉴 건너뛰기




Volumn 40, Issue 4, 1998, Pages 598-605

Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times

Author keywords

Foreign body response; Implants; PTFE; PVA; Sensors; Subcutaneous implants; Tissue response; Vascularity

Indexed keywords

BIOCOMPATIBILITY; BLOOD VESSELS; DENSITY (SPECIFIC GRAVITY); DYES; IMPLANTS (SURGICAL); MASS TRANSFER; MATHEMATICAL MODELS; POLYTETRAFLUOROETHYLENES; POLYVINYL ALCOHOLS; POROUS MATERIALS;

EID: 0032527066     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(19980615)40:4<598::AID-JBM11>3.0.CO;2-C     Document Type: Article
Times cited : (110)

References (9)
  • 2
    • 0025688886 scopus 로고
    • The glucose sensor: The missing link in diabetes therapy
    • E. F. Pfeiffer, "The glucose sensor: The missing link in diabetes therapy," Horm. Metab. Res., Supplement, 24, 154-164 (1990).
    • (1990) Horm. Metab. Res., Supplement , vol.24 , pp. 154-164
    • Pfeiffer, E.F.1
  • 3
    • 0028106630 scopus 로고
    • Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
    • B. J. Gilligan, M. C. Shults, R. K. Rhodes, and S. J. Updike, "Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model," Diabetes Care, 17, 882-887 (1994).
    • (1994) Diabetes Care , vol.17 , pp. 882-887
    • Gilligan, B.J.1    Shults, M.C.2    Rhodes, R.K.3    Updike, S.J.4
  • 4
    • 0031555495 scopus 로고    scopus 로고
    • Engineering the tissue that encapsulates subcutaneous implants. I. Diffusion properties
    • A. A. Sharkawy, B. Klitzman, G. A. Truskey, and W. M. Reichert, "Engineering the tissue that encapsulates subcutaneous implants. I. Diffusion properties," J. Biomed. Mater. Res., 37, 401-412 (1997).
    • (1997) J. Biomed. Mater. Res. , vol.37 , pp. 401-412
    • Sharkawy, A.A.1    Klitzman, B.2    Truskey, G.A.3    Reichert, W.M.4
  • 5
    • 0032527092 scopus 로고    scopus 로고
    • Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties
    • A. A. Sharkawy, B. Klitzman, G. A. Truskey, and W. M. Reichert, "Engineering the tissue which encapsulates subcutaneous implants. II. Plasma-tissue exchange properties," J. Biomed. Mater. Res., 40, 586-597 (1998).
    • (1998) J. Biomed. Mater. Res. , vol.40 , pp. 586-597
    • Sharkawy, A.A.1    Klitzman, B.2    Truskey, G.A.3    Reichert, W.M.4
  • 6
    • 0024570260 scopus 로고
    • Factors influencing blood supply in wound granuloma quantitated by a new in vivo technique
    • V. Mahadevan, I. R. Hart, and G. P. Lewis, "Factors influencing blood supply in wound granuloma quantitated by a new in vivo technique," Cancer Res. 49, 415-419 (1989).
    • (1989) Cancer Res. , vol.49 , pp. 415-419
    • Mahadevan, V.1    Hart, I.R.2    Lewis, G.P.3
  • 7
    • 0023611126 scopus 로고
    • Quantitative in vivo studies on angiogenesis in a rat sponge model
    • S. P. Andrade, T.-P. D. Fan, and G. P. Lewis, "Quantitative in vivo studies on angiogenesis in a rat sponge model," Br. J. Exp. Pathol, 68, 755-766 (1987).
    • (1987) Br. J. Exp. Pathol , vol.68 , pp. 755-766
    • Andrade, S.P.1    Fan, T.-P.D.2    Lewis, G.P.3
  • 8
    • 0026706501 scopus 로고
    • Effects of platelet activating factor (PAF) and other vasoconstrictors on a model of angiogenesis in the mouse
    • S. P. Andrade, L. B. G. B. Vieira, Y. S. Bakhle, and P. J. Piper, "Effects of platelet activating factor (PAF) and other vasoconstrictors on a model of angiogenesis in the mouse," J. Exp. Pathol., 73, 503-513 (1992).
    • (1992) J. Exp. Pathol. , vol.73 , pp. 503-513
    • Andrade, S.P.1    Vieira, L.B.G.B.2    Bakhle, Y.S.3    Piper, P.J.4
  • 9
    • 0028065477 scopus 로고
    • Measurement of vascular volume fraction and blood-tissue permeablility constants with a pharmokinetic model: Studies in rat muscle tumors with dynamic Gd-DPTA enhanced MRI
    • M. Y. Su, J. C. Jao, and O. Nalcioglu, "Measurement of vascular volume fraction and blood-tissue permeablility constants with a pharmokinetic model: Studies in rat muscle tumors with dynamic Gd-DPTA enhanced MRI," Magn. Reson. Med., 32, 714-724 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 714-724
    • Su, M.Y.1    Jao, J.C.2    Nalcioglu, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.