-
1
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. New Engl J Med. 329:1993;977-86.
-
(1993)
New Engl J Med
, vol.329
, pp. 977-986
-
-
-
2
-
-
0029147687
-
Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus: A randomized prospective study
-
Ohkubo Y., Kisikawa H., Araki E., Miyata T., Isami S., Motoyoshi S., Kojima Y., Furuyoshi N., Shichiri M. Intensive insulin therapy prevents the progression of diabetic microvascular complications in Japanese patients with non-insulin-dependent diabetes mellitus: A randomized prospective study. Diabetes Res Clin Pract. 28:1995;103-117.
-
(1995)
Diabetes Res Clin Pract
, vol.28
, pp. 103-117
-
-
Ohkubo, Y.1
Kisikawa, H.2
Araki, E.3
Miyata, T.4
Isami, S.5
Motoyoshi, S.6
Kojima, Y.7
Furuyoshi, N.8
Shichiri, M.9
-
3
-
-
0032511583
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33. Lancet. 352:1998;837-853.
-
(1998)
Lancet
, vol.352
, pp. 837-853
-
-
-
4
-
-
0025992949
-
Microdialysis of adipose tissue
-
Arner P., Bolinder J. Microdialysis of adipose tissue. J Int Med. 230:1991;381-386.
-
(1991)
J Int Med
, vol.230
, pp. 381-386
-
-
Arner, P.1
Bolinder, J.2
-
5
-
-
0027527667
-
A subcutaneous capillary filtrate collector for measurement of blood chemistries
-
Ash S.R., Rainier J.B., Zopp W.E., Truitt R.B., Janle E.M., Kissinger P.T., Poulos J.T. A subcutaneous capillary filtrate collector for measurement of blood chemistries. ASAIO J. 39:1993;M699-705.
-
(1993)
ASAIO J
, vol.39
, pp. 699-705
-
-
Ash, S.R.1
Rainier, J.B.2
Zopp, W.E.3
Truitt, R.B.4
Janle, E.M.5
Kissinger, P.T.6
Poulos, J.T.7
-
6
-
-
0026440913
-
Suction effusion fluid from skin and constituent analysis: New candidate for interstitial fluid
-
Kayashima S., Arai T., Kikuchi M., Nagata N., Ito N., Kuriyama T., Kimura J. Suction effusion fluid from skin and constituent analysis: new candidate for interstitial fluid. Am J Physiol. 263:1992;H1623-H1627.
-
(1992)
Am J Physiol
, vol.263
-
-
Kayashima, S.1
Arai, T.2
Kikuchi, M.3
Nagata, N.4
Ito, N.5
Kuriyama, T.6
Kimura, J.7
-
7
-
-
0028823945
-
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
-
Tamada J.A., Bohannon N.J.V., Potts R.O. Measurement of glucose in diabetic subjects using noninvasive transdermal extraction. Nature Med. 1:(11):1995;1198-1201.
-
(1995)
Nature Med
, vol.1
, Issue.11
, pp. 1198-1201
-
-
Tamada, J.A.1
Bohannon, N.J.V.2
Potts, R.O.3
-
8
-
-
0031864724
-
Non-invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors
-
on behalf of the Non-invasive task force
-
Heinemann L., Schmelzeisen-Redeker G, on behalf of the Non-invasive task force. Non-invasive continuous glucose monitoring in type 1 diabetic patients with optical glucose sensors. Daibetologia 1998;41:848-54.
-
(1998)
Daibetologia
, vol.41
, pp. 848-854
-
-
Heinemann, L.1
Schmelzeisen-Redeker, G.2
-
9
-
-
0026744848
-
Microdialysis and glucose biosensor for in vivo monitoring
-
Moscone D., Mascini M. Microdialysis and glucose biosensor for in vivo monitoring. Ann Biol Clin. 50:1992;323-327.
-
(1992)
Ann Biol Clin
, vol.50
, pp. 323-327
-
-
Moscone, D.1
Mascini, M.2
-
10
-
-
0026761167
-
On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis
-
Meyerhoff C., Bischof F., Sternberg F., Zier H., Pfeiffer E.F. On line continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis. Diabetologia. 35:1992;1087-1092.
-
(1992)
Diabetologia
, vol.35
, pp. 1087-1092
-
-
Meyerhoff, C.1
Bischof, F.2
Sternberg, F.3
Zier, H.4
Pfeiffer, E.F.5
-
11
-
-
0028218970
-
Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method
-
Hashiguchi Y., Sakakida M., Nishida K., Uemura T., Kajiwara K., Shichiri M. Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Diabetes Care. 17:1994;387-396.
-
(1994)
Diabetes Care
, vol.17
, pp. 387-396
-
-
Hashiguchi, Y.1
Sakakida, M.2
Nishida, K.3
Uemura, T.4
Kajiwara, K.5
Shichiri, M.6
-
12
-
-
0028832058
-
Portable system for on-line continuous ex vivo monitoring of subcutaneous tissue glucose using open tissue perfusion
-
Skrabal F., Trajanoski Z., Kontscheider H., Kotanko P., Wach P. Portable system for on-line continuous ex vivo monitoring of subcutaneous tissue glucose using open tissue perfusion. Med Biol Eng Comput. 33:1995;116-118.
-
(1995)
Med Biol Eng Comput
, vol.33
, pp. 116-118
-
-
Skrabal, F.1
Trajanoski, Z.2
Kontscheider, H.3
Kotanko, P.4
Wach, P.5
-
13
-
-
0026580287
-
Calibration of a wearable glucose sensor
-
Schmidt F.J., Aalders A.L., Schoonen A.J.M., Doorenbos H. Calibration of a wearable glucose sensor. Int J Artif Organs. 15:(1):1992;55-61.
-
(1992)
Int J Artif Organs
, vol.15
, Issue.1
, pp. 55-61
-
-
Schmidt, F.J.1
Aalders, A.L.2
Schoonen, A.J.M.3
Doorenbos, H.4
-
14
-
-
0029801718
-
Current status of the glucose sensor
-
Meyerhoff C., Mennel F.J., Sternberg F., Hoss U., Pfeiffer E.F. Current status of the glucose sensor. Endocrinologist. 6:1996;332-339.
-
(1996)
Endocrinologist
, vol.6
, pp. 332-339
-
-
Meyerhoff, C.1
Mennel, F.J.2
Sternberg, F.3
Hoss, U.4
Pfeiffer, E.F.5
-
15
-
-
0030662334
-
Detection of hypoglycaemia by microdialysis measurements of glucose in subcutaneous adipose tissue
-
Moberg E., Hagstrom-Toft E., Bolinder J. Detection of hypoglycaemia by microdialysis measurements of glucose in subcutaneous adipose tissue. Horm Metab Res. 29:1997;440-443.
-
(1997)
Horm Metab Res
, vol.29
, pp. 440-443
-
-
Moberg, E.1
Hagstrom-Toft, E.2
Bolinder, J.3
-
17
-
-
0344851074
-
-
Assen, The Netherlands: Van gorcum and comp. B.V
-
Zijlstra W.G., Brunsting J.R., Ter Hoor F., Mook G.A., Rispens P. Fysiology of the milieu interieur. 1973;Van gorcum and comp. B.V, Assen, The Netherlands.
-
(1973)
Fysiology of the Milieu Interieur
-
-
Zijlstra, W.G.1
Brunsting, J.R.2
Ter Hoor, F.3
Mook, G.A.4
Rispens, P.5
-
18
-
-
0004189734
-
-
Chichester, England and Stuttgart, Germany: Wiley and Teubner
-
Eggins B. Biosensors: an introduction. 1996;Wiley and Teubner, Chichester, England and Stuttgart, Germany.
-
(1996)
Biosensors: An Introduction
-
-
Eggins, B.1
-
20
-
-
0030175963
-
Glucose monitoring: State of the art and future possibilities
-
Wilkins E., Atanasov P. Glucose monitoring: state of the art and future possibilities. Med Eng Phys. 18:(4):1996;273-288.
-
(1996)
Med Eng Phys
, vol.18
, Issue.4
, pp. 273-288
-
-
Wilkins, E.1
Atanasov, P.2
-
21
-
-
0026756276
-
Progress toward the development of an implantable sensor for glucose
-
Wilson G.S., Zhang Y., Reach G., Moatti-Sirat D., Poitout V., Thevenot D.R., Lemonnier F., Klein J.C. Progress toward the development of an implantable sensor for glucose. Clin Chem. 38:(9):1992;1613-1617.
-
(1992)
Clin Chem
, vol.38
, Issue.9
, pp. 1613-1617
-
-
Wilson, G.S.1
Zhang, Y.2
Reach, G.3
Moatti-Sirat, D.4
Poitout, V.5
Thevenot, D.R.6
Lemonnier, F.7
Klein, J.C.8
-
22
-
-
0022269013
-
Diabetes mellitus: Biosensors for research and management
-
Turner A.P.F., Pickup J.C. Diabetes mellitus: biosensors for research and management. Biosensors. 1:1985;85-115.
-
(1985)
Biosensors
, vol.1
, pp. 85-115
-
-
Turner, A.P.F.1
Pickup, J.C.2
-
23
-
-
0028413636
-
Enzymatic glucose sensors: Improved long-term performance in vitro and in vivo
-
Updike S.J., Shults M.C., Rhodes R.K., Gilligan B.J., Luebow J.O., von Heimburg D. Enzymatic glucose sensors: improved long-term performance in vitro and in vivo. ASAIO J. 40:1994;157-163.
-
(1994)
ASAIO J
, vol.40
, pp. 157-163
-
-
Updike, S.J.1
Shults, M.C.2
Rhodes, R.K.3
Gilligan, B.J.4
Luebow, J.O.5
Von Heimburg, D.6
-
24
-
-
0028106630
-
Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model
-
Gilligan B.J., Shults M.C., Rhodes R.K., Updike S.J. Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model. Diabetes Care. 17:1994;882-887.
-
(1994)
Diabetes Care
, vol.17
, pp. 882-887
-
-
Gilligan, B.J.1
Shults, M.C.2
Rhodes, R.K.3
Updike, S.J.4
-
25
-
-
0028518589
-
A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors
-
Shults M.C., Rhodes R.K., Updike S.J., Gilligan B.J., Reining W.N. A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors. IEEE Trans Biomed Eng. 41:1994;937-942.
-
(1994)
IEEE Trans Biomed Eng
, vol.41
, pp. 937-942
-
-
Shults, M.C.1
Rhodes, R.K.2
Updike, S.J.3
Gilligan, B.J.4
Reining, W.N.5
-
26
-
-
0006286279
-
European achievements in sensor research dedicated to in vivo monitoring
-
London, UK: JAI Press Ltd
-
Pickup J.C., Thevenot D.R. European achievements in sensor research dedicated to in vivo monitoring. Advances in biosensors, supplement 1. 1993;201-225 JAI Press Ltd, London, UK.
-
(1993)
Advances in Biosensors, Supplement 1
, pp. 201-225
-
-
Pickup, J.C.1
Thevenot, D.R.2
-
27
-
-
0027411735
-
In vivo glucose monitoring: Sense and sensorbility
-
Pickup J.C. In vivo glucose monitoring: sense and sensorbility. Diabetes Care. 16:(2):1993;535-539.
-
(1993)
Diabetes Care
, vol.16
, Issue.2
, pp. 535-539
-
-
Pickup, J.C.1
-
28
-
-
0029047790
-
Bio-/haemocompatibility: Implications and outcomes for sensors>
-
Kyrolainen M., Rigsby P., Eddy S., Vadgama P. Bio-/haemocompatibility: implications and outcomes for sensors>. Acta Anaesthesiol Scand. 39:(suppl. 104):1995;55-60.
-
(1995)
Acta Anaesthesiol Scand
, vol.39
, Issue.SUPPL. 104
, pp. 55-60
-
-
Kyrolainen, M.1
Rigsby, P.2
Eddy, S.3
Vadgama, P.4
-
29
-
-
0024247171
-
Implantable electrochemical glucose sensors: State of the art
-
Cammann K. Implantable electrochemical glucose sensors: state of the art. Horm Metab Res Suppl. 20:1988;4-8.
-
(1988)
Horm Metab Res Suppl
, vol.20
, pp. 4-8
-
-
Cammann, K.1
-
30
-
-
0028807108
-
Development of the implantable glucose sensor: What are the prospects and why is it taking so long?
-
Gough D.A., Armour J.C. Development of the implantable glucose sensor: what are the prospects and why is it taking so long? Diabetes. 44:1995;1005-1009.
-
(1995)
Diabetes
, vol.44
, pp. 1005-1009
-
-
Gough, D.A.1
Armour, J.C.2
-
31
-
-
0024731147
-
Towards implantable glucose sensors: A review
-
Wilkins E.S. Towards implantable glucose sensors: a review. J Biomed Eng. 11:1989;354-361.
-
(1989)
J Biomed Eng
, vol.11
, pp. 354-361
-
-
Wilkins, E.S.1
-
32
-
-
0025849027
-
Fundamentals of glucose sensors
-
Fischer U. Fundamentals of glucose sensors. Diabetic Medicine. 8:1991;309-321.
-
(1991)
Diabetic Medicine
, vol.8
, pp. 309-321
-
-
Fischer, U.1
-
33
-
-
0028533426
-
In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing
-
Moussy F., Jakeway S., Harrison J.D., Rajotte R.V. In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing. Anal Chem. 66:1994;3882-3888.
-
(1994)
Anal Chem
, vol.66
, pp. 3882-3888
-
-
Moussy, F.1
Jakeway, S.2
Harrison, J.D.3
Rajotte, R.V.4
-
34
-
-
0027746317
-
The function of a hydrogen peroxide-detecting electroenzymatic glucose sensor is markedly impaired in human subcutaneous tissue and plasma
-
Kerner W., Kiwit M., Linke B., Keck F., Zier H., Pfeiffer E.F. The function of a hydrogen peroxide-detecting electroenzymatic glucose sensor is markedly impaired in human subcutaneous tissue and plasma. Biosens Bioelectr. 8:1993;473-482.
-
(1993)
Biosens Bioelectr
, vol.8
, pp. 473-482
-
-
Kerner, W.1
Kiwit, M.2
Linke, B.3
Keck, F.4
Zier, H.5
Pfeiffer, E.F.6
-
36
-
-
0021148018
-
Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell
-
Abel P., Muller A., Fischer U. Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell. Biomed Biochim Acta. 43:1984;577-584.
-
(1984)
Biomed Biochim Acta
, vol.43
, pp. 577-584
-
-
Abel, P.1
Muller, A.2
Fischer, U.3
-
39
-
-
0024342096
-
Automated feedback control of subcutaneous glucose concentration in diabetic dogs
-
Rebrin K., Fischer U., von Woedtke T., Abel P., Brunstein E. Automated feedback control of subcutaneous glucose concentration in diabetic dogs. Diabetologia. 32:1989;573-576.
-
(1989)
Diabetologia
, vol.32
, pp. 573-576
-
-
Rebrin, K.1
Fischer, U.2
Von Woedtke, T.3
Abel, P.4
Brunstein, E.5
-
40
-
-
0024541965
-
In vivo molecular sensing in diabetes mellitus: An implantable glucose sensor with direct electron transfer
-
Pickup J.C., Shaw G.W., Claremont D.J. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia. 32:1989;231-217.
-
(1989)
Diabetologia
, vol.32
, pp. 231-217
-
-
Pickup, J.C.1
Shaw, G.W.2
Claremont, D.J.3
-
41
-
-
0026546742
-
Towards continuous glucose monitoring: In vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue
-
Moatti-Sirat D., Capron F., Poitout V., Reach G., Bindra D.S., Zhang Y., Wilson G.S., Thevenot D.R. Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue. Diabetologia. 35:1992;224-230.
-
(1992)
Diabetologia
, vol.35
, pp. 224-230
-
-
Moatti-Sirat, D.1
Capron, F.2
Poitout, V.3
Reach, G.4
Bindra, D.S.5
Zhang, Y.6
Wilson, G.S.7
Thevenot, D.R.8
-
42
-
-
0026590041
-
Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor
-
Moatti-Sirat D., Vehlo G., Reach G. Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor. Biosens and Bioelectr. 7:1992;345-352.
-
(1992)
Biosens and Bioelectr
, vol.7
, pp. 345-352
-
-
Moatti-Sirat, D.1
Vehlo, G.2
Reach, G.3
-
43
-
-
0028272196
-
Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: Demonstration in rats and man
-
Moatti-Sirat D., Poitout V., Thome V., Gangnerau M.N., Zhang Y., Hu Y., Wilson G.S., Lemonnier F., Klein J.C., Reach G. Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man. Diabetologia. 37:1994;610-616.
-
(1994)
Diabetologia
, vol.37
, pp. 610-616
-
-
Moatti-Sirat, D.1
Poitout, V.2
Thome, V.3
Gangnerau, M.N.4
Zhang, Y.5
Hu, Y.6
Wilson, G.S.7
Lemonnier, F.8
Klein, J.C.9
Reach, G.10
-
44
-
-
0027214964
-
A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit
-
Poitout V., Moatti-Sirat D., Reach G., Wilson G.S., Lemonnier F., Klein J.C. A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit. Diabetologia. 36:1993;658-663.
-
(1993)
Diabetologia
, vol.36
, pp. 658-663
-
-
Poitout, V.1
Moatti-Sirat, D.2
Reach, G.3
Wilson, G.S.4
Lemonnier, F.5
Klein, J.C.6
-
45
-
-
0026192568
-
In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor
-
Poitout V., Moatti D., Vehlo G., Reach G., Sternberg R., Thevenot D.R., Bindra D.S., Zhang Y., Wilson G.S. In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor. ASAIO Trans. 37:1991;M298-M300.
-
(1991)
ASAIO Trans
, vol.37
-
-
Poitout, V.1
Moatti, D.2
Vehlo, G.3
Reach, G.4
Sternberg, R.5
Thevenot, D.R.6
Bindra, D.S.7
Zhang, Y.8
Wilson, G.S.9
-
46
-
-
0026491971
-
Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination
-
Poitout V., Moatti-Sirat D., Reach G. Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination. Biosens and Bioelectr. 7:1992;587-592.
-
(1992)
Biosens and Bioelectr
, vol.7
, pp. 587-592
-
-
Poitout, V.1
Moatti-Sirat, D.2
Reach, G.3
-
47
-
-
0027102347
-
In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
-
Johnson K.W., Mastrototaro J.J., Howey D.C., Brunelle R.L., Burden-Brady P.L., Bryan N.A., Andrew C.C., Rowe H.M., Allen D.J., Noffke B.W., McMahan W.C., Morff R.J., Lipson D., Nevin R.S. In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue. Biosens and Bioelectr. 7:1992;709-714.
-
(1992)
Biosens and Bioelectr
, vol.7
, pp. 709-714
-
-
Johnson, K.W.1
Mastrototaro, J.J.2
Howey, D.C.3
Brunelle, R.L.4
Burden-Brady, P.L.5
Bryan, N.A.6
Andrew, C.C.7
Rowe, H.M.8
Allen, D.J.9
Noffke, B.W.10
McMahan, W.C.11
Morff, R.J.12
Lipson, D.13
Nevin, R.S.14
-
48
-
-
0025873893
-
Implantable glucose sensors: Comparison between in vitro and in vivo kinetics
-
Von Woedtke T., Fischer U., Brunstein E., Rebrin K., Abel P. Implantable glucose sensors: comparison between in vitro and in vivo kinetics. Int J Artif Organs. 14:1991;473-481.
-
(1991)
Int J Artif Organs
, vol.14
, pp. 473-481
-
-
Von Woedtke, T.1
Fischer, U.2
Brunstein, E.3
Rebrin, K.4
Abel, P.5
-
49
-
-
0024243378
-
In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics
-
Velho G., Froguel Ph., Thevenot D.R., Reach G. In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics. Diab Nutr Metab. 3:1988;227-233.
-
(1988)
Diab Nutr Metab
, vol.3
, pp. 227-233
-
-
Velho, G.1
Froguel, Ph.2
Thevenot, D.R.3
Reach, G.4
-
50
-
-
0027474090
-
On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucose sensor with microdialysis
-
Pfeiffer E.F., Meyerhoff C., Bischof F., Keck F.S., Kerner W. On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucose sensor with microdialysis. Horm Metab Res. 25:1993;121-124.
-
(1993)
Horm Metab Res
, vol.25
, pp. 121-124
-
-
Pfeiffer, E.F.1
Meyerhoff, C.2
Bischof, F.3
Keck, F.S.4
Kerner, W.5
-
51
-
-
0024957245
-
In vivo response of microfabricated glucose sensors to glycaemia changes in normal rats
-
Koudelka M., Rohner-Jeanrenaud F., Terrettaz J., Bobbioni-Harsch E., de Rooij N.F., Jeanrenaud B. In vivo response of microfabricated glucose sensors to glycaemia changes in normal rats. Biomed Biochim Acta. 48:1989;953-956.
-
(1989)
Biomed Biochim Acta
, vol.48
, pp. 953-956
-
-
Koudelka, M.1
Rohner-Jeanrenaud, F.2
Terrettaz, J.3
Bobbioni-Harsch, E.4
De Rooij, N.F.5
Jeanrenaud, B.6
-
52
-
-
0025919989
-
In vivo behaviour of hypodermically implanted microfabricated glucose sensors
-
Koudelka M., Rohner-Jeanrenaud F., Terrettaz J., Bobbioni-Harsch E., de Rooij N.F., Jeanrenaud B. In vivo behaviour of hypodermically implanted microfabricated glucose sensors. Biosens Bioelectr. 6:1991;31-36.
-
(1991)
Biosens Bioelectr
, vol.6
, pp. 31-36
-
-
Koudelka, M.1
Rohner-Jeanrenaud, F.2
Terrettaz, J.3
Bobbioni-Harsch, E.4
De Rooij, N.F.5
Jeanrenaud, B.6
-
53
-
-
0027703516
-
Lifespan of subcutaneous glucose sensors and their performances during glycaemia changes in rats
-
Bobbioni-Harsch E., Rohner-Jeanrenaud F., Koudelka M., de Rooij N., Jeanrenaud B. Lifespan of subcutaneous glucose sensors and their performances during glycaemia changes in rats. J Biomed Eng. 15:1993;457-463.
-
(1993)
J Biomed Eng
, vol.15
, pp. 457-463
-
-
Bobbioni-Harsch, E.1
Rohner-Jeanrenaud, F.2
Koudelka, M.3
De Rooij, N.4
Jeanrenaud, B.5
-
54
-
-
0024269445
-
Study and development of multilayer needle-type enzyme-based glucose microsensors
-
Sternberg R., Barrau M.B., Gangiotti L., Thevenot D.R., Bindra D.S., Wilson G.S., Vehlo G., Froguel P., Reach G. Study and development of multilayer needle-type enzyme-based glucose microsensors. Biosensors. 4:1988;27-40.
-
(1988)
Biosensors
, vol.4
, pp. 27-40
-
-
Sternberg, R.1
Barrau, M.B.2
Gangiotti, L.3
Thevenot, D.R.4
Bindra, D.S.5
Wilson, G.S.6
Vehlo, G.7
Froguel, P.8
Reach, G.9
-
56
-
-
0024956219
-
In situ calibration of implanted electrochemical glucose sensors
-
Von Woedtke T., Rebrin K., Fischer U., Abel P., Wilke W., Vogt L., Albrecht G. In situ calibration of implanted electrochemical glucose sensors. Biomed Biochim Acta. 48:1989;943-952.
-
(1989)
Biomed Biochim Acta
, vol.48
, pp. 943-952
-
-
Von Woedtke, T.1
Rebrin, K.2
Fischer, U.3
Abel, P.4
Wilke, W.5
Vogt, L.6
Albrecht, G.7
-
58
-
-
0023438761
-
Tissue-biomaterial interactions
-
Williams D.F. Tissue-biomaterial interactions. J Mat Sci. 22:1987;3421-3445.
-
(1987)
J Mat Sci
, vol.22
, pp. 3421-3445
-
-
Williams, D.F.1
-
62
-
-
0028136098
-
Rapid detection of hyperglycaemia by a subcutaneously implanted glucose sensor in the rat
-
Ward W.K., Wilgus W., Troupe J.E. Rapid detection of hyperglycaemia by a subcutaneously implanted glucose sensor in the rat. Biosens Bioelectr. 9:1994;423-428.
-
(1994)
Biosens Bioelectr
, vol.9
, pp. 423-428
-
-
Ward, W.K.1
Wilgus, W.2
Troupe, J.E.3
-
63
-
-
0028183143
-
A miniaturized Nafion-based glucose sensor: In vitro and in vivo evaluation in dogs
-
Moussy F., Harrison D.J., Rajotte R.V. A miniaturized Nafion-based glucose sensor: in vitro and in vivo evaluation in dogs. Int J Artif Organs. 17:1994;88-94.
-
(1994)
Int J Artif Organs
, vol.17
, pp. 88-94
-
-
Moussy, F.1
Harrison, D.J.2
Rajotte, R.V.3
-
64
-
-
0027650815
-
Performance of subcutaneously implanted needle-type glucose sensors employing a Novel trilayer coating
-
Moussy F., Harrison D.J., O'Brein D.W., Rajotte R.V. Performance of subcutaneously implanted needle-type glucose sensors employing a Novel trilayer coating. Anal Chem. 65:1993;2072-2077.
-
(1993)
Anal Chem
, vol.65
, pp. 2072-2077
-
-
Moussy, F.1
Harrison, D.J.2
O'Brein, D.W.3
Rajotte, R.V.4
-
65
-
-
0021228204
-
The development of wearable-type artificial endocrine pancreas and its usefulness in glycaemic control of human diabetes mellitus
-
Shichiri M., Kawamori R., Hakui N., Asakawa N., Yamasaki Y., Abe H. The development of wearable-type artificial endocrine pancreas and its usefulness in glycaemic control of human diabetes mellitus. Biomed Biochim Acta. 5:1984;561-568.
-
(1984)
Biomed Biochim Acta
, vol.5
, pp. 561-568
-
-
Shichiri, M.1
Kawamori, R.2
Hakui, N.3
Asakawa, N.4
Yamasaki, Y.5
Abe, H.6
-
66
-
-
0024270045
-
In vivo characteristics of needle-type glucose sensor: Measurements of subcutaneous glucose concentrations in human volunteers
-
Shichiri M., Yamasaki Y., Nao K., Sekiya M., Ueda N. In vivo characteristics of needle-type glucose sensor: measurements of subcutaneous glucose concentrations in human volunteers. Horm Metab Res Suppl. 20:1988;17-20.
-
(1988)
Horm Metab Res Suppl
, vol.20
, pp. 17-20
-
-
Shichiri, M.1
Yamasaki, Y.2
Nao, K.3
Sekiya, M.4
Ueda, N.5
-
67
-
-
0022481785
-
Continuous monitoring of subcutaneous glucose concentration using implanted enzyme electrodes
-
Muller A., Abel P., Fischer U. Continuous monitoring of subcutaneous glucose concentration using implanted enzyme electrodes. Biomed Biochim Acta. 45:1986;769-777.
-
(1986)
Biomed Biochim Acta
, vol.45
, pp. 769-777
-
-
Muller, A.1
Abel, P.2
Fischer, U.3
-
68
-
-
0024954424
-
Preparation and validation of implantable electrodes for the measurement of oxygen and glucose
-
Brunstein E., Abel P., Gens A., Eich K., von Woedtke T. Preparation and validation of implantable electrodes for the measurement of oxygen and glucose. Biomed Biochim Acta. 48:1989;911-917.
-
(1989)
Biomed Biochim Acta
, vol.48
, pp. 911-917
-
-
Brunstein, E.1
Abel, P.2
Gens, A.3
Eich, K.4
Von Woedtke, T.5
-
69
-
-
0029256656
-
Open flow microperfusion: Approach to in vivo glucose monitoring
-
Rigby G.P., Crump P., Vadgama P. Open flow microperfusion: approach to in vivo glucose monitoring. Med Biol Eng Comput. 33:1995;231-234.
-
(1995)
Med Biol Eng Comput
, vol.33
, pp. 231-234
-
-
Rigby, G.P.1
Crump, P.2
Vadgama, P.3
-
70
-
-
0029883087
-
Stabilized needle electrode system for in vivo glucose monitoring based on open flow microperfusion
-
Rigby G.P., Crump P., Vadgama P. Stabilized needle electrode system for in vivo glucose monitoring based on open flow microperfusion. Analyst. 121:1996;871-875.
-
(1996)
Analyst
, vol.121
, pp. 871-875
-
-
Rigby, G.P.1
Crump, P.2
Vadgama, P.3
-
71
-
-
0024731165
-
Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors
-
Ertefai S., Gough D.A. Physiological preparation for studying the response of subcutaneously implanted glucose and oxygen sensors. J Biomed Eng. 11:1989;362-368.
-
(1989)
J Biomed Eng
, vol.11
, pp. 362-368
-
-
Ertefai, S.1
Gough, D.A.2
-
72
-
-
0025919989
-
In vivo behaviour of hypodermically implanted microfabricated glucose sensors
-
Koudelka M., Rohner-Jeanrenaud F., Terrettaz J., Bobbioni-Harsch E., de Rooij N.F., Jeanrenaud B. In vivo behaviour of hypodermically implanted microfabricated glucose sensors. Biosens Bioelectr. 6:1991;31-36.
-
(1991)
Biosens Bioelectr
, vol.6
, pp. 31-36
-
-
Koudelka, M.1
Rohner-Jeanrenaud, F.2
Terrettaz, J.3
Bobbioni-Harsch, E.4
De Rooij, N.F.5
Jeanrenaud, B.6
-
73
-
-
0026657012
-
Immune response in biocompatibility
-
Remes A., Williams D.F. Immune response in biocompatibility. Biomaterials. 13:(11):1992;731-743.
-
(1992)
Biomaterials
, vol.13
, Issue.11
, pp. 731-743
-
-
Remes, A.1
Williams, D.F.2
-
74
-
-
0028835619
-
Neutrophil-mediated degradation of segmented polyurethanes
-
Labow R.S., Erfle D.J., Santerre J.P. Neutrophil-mediated degradation of segmented polyurethanes. Biomaterials. 16:1995;51-59.
-
(1995)
Biomaterials
, vol.16
, pp. 51-59
-
-
Labow, R.S.1
Erfle, D.J.2
Santerre, J.P.3
-
76
-
-
0026593281
-
Subcutaneous glucose monitoring by means of electrochemical sensors: Fiction or reality?
-
Rebrin K., Fischer U., Hahn von Dorsche H., von Woetke T., Abel P., Brunstein E. Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality? J Biomed Eng. 14:1992;33-40.
-
(1992)
J Biomed Eng
, vol.14
, pp. 33-40
-
-
Rebrin, K.1
Fischer, U.2
Hahn Von Dorsche, H.3
Von Woetke, T.4
Abel, P.5
Brunstein, E.6
-
77
-
-
0020058620
-
Implanting the glucose enzyme electrode: Problems, progress, and alternative solutions
-
Updike S.J., Shults M., Ekman B. Implanting the glucose enzyme electrode: problems, progress, and alternative solutions. Diabetes Care. 5:(3):1982;207-212.
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 207-212
-
-
Updike, S.J.1
Shults, M.2
Ekman, B.3
-
78
-
-
0024957628
-
Oxygen tension at the subcutaneous implantation site of glucose sensors
-
Fischer U., Hidde A., Herrmann S., von Woedtke T., Rebrin K., Abel P. Oxygen tension at the subcutaneous implantation site of glucose sensors. Biomed Biochim Acta. 48:1989;965-971.
-
(1989)
Biomed Biochim Acta
, vol.48
, pp. 965-971
-
-
Fischer, U.1
Hidde, A.2
Herrmann, S.3
Von Woedtke, T.4
Rebrin, K.5
Abel, P.6
-
79
-
-
0027236355
-
In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor
-
Zhang Y., Wilson G.S. In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor. Anal Chim Acta. 281:1993;513-520.
-
(1993)
Anal Chim Acta
, vol.281
, pp. 513-520
-
-
Zhang, Y.1
Wilson, G.S.2
-
80
-
-
0019755209
-
The implantation of a closed-loop artificial beta cell in dogs
-
Bessman S.P., Thomas L.J., Koijma H., Sayler D.F., Layne E.C. The implantation of a closed-loop artificial beta cell in dogs. Trans Am Soc Artif Int Organs. 27:1981;7-17.
-
(1981)
Trans Am Soc Artif Int Organs
, vol.27
, pp. 7-17
-
-
Bessman, S.P.1
Thomas, L.J.2
Koijma, H.3
Sayler, D.F.4
Layne, E.C.5
-
81
-
-
0028145267
-
BIOMED concerted action chemical sensors for in vivo monitoring. The biocompatibility issue
-
Reach G., Feijen J., Alcock A. BIOMED concerted action chemical sensors for in vivo monitoring. The biocompatibility issue. Biosens Bioelectr. 9:(6):1994;21-28.
-
(1994)
Biosens Bioelectr
, vol.9
, Issue.6
, pp. 21-28
-
-
Reach, G.1
Feijen, J.2
Alcock, A.3
-
82
-
-
0020002501
-
How fibroblasts and giant cells encapsulate implants: Considerations in design of glucose sensors
-
Woodward S.C. How fibroblasts and giant cells encapsulate implants: considerations in design of glucose sensors. Diabetes Care. 5:1982;278-281.
-
(1982)
Diabetes Care
, vol.5
, pp. 278-281
-
-
Woodward, S.C.1
-
83
-
-
0031555495
-
Engineering the tissue which encapsulates subcutaneous implants. 1. Diffusion properties
-
Sharkawy A.A., Klitzman B., Truskey G.A., Reichert W.M. Engineering the tissue which encapsulates subcutaneous implants. 1. Diffusion properties. J Biomed Mater Res. 37:1997;401-412.
-
(1997)
J Biomed Mater Res
, vol.37
, pp. 401-412
-
-
Sharkawy, A.A.1
Klitzman, B.2
Truskey, G.A.3
Reichert, W.M.4
-
85
-
-
0020402631
-
Wearable artificial endocrine pancreas with needle-type glucose sensor
-
Shichiri M., Yamasaki Y., Kawamori R., Hakui N. Wearable artificial endocrine pancreas with needle-type glucose sensor. Lancet. 20:1982;1129-1130.
-
(1982)
Lancet
, vol.20
, pp. 1129-1130
-
-
Shichiri, M.1
Yamasaki, Y.2
Kawamori, R.3
Hakui, N.4
-
86
-
-
0022485273
-
Telemetry glucose monitoring device with needle-type glucose sensor: A useful tool for blood glucose monitoring in diabetic individuals
-
Shichiri M., Asakawa N., Yamasaki Y., Kawamori R., Abe H. Telemetry glucose monitoring device with needle-type glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals. Diabetes Care. 9:1986;298-301.
-
(1986)
Diabetes Care
, vol.9
, pp. 298-301
-
-
Shichiri, M.1
Asakawa, N.2
Yamasaki, Y.3
Kawamori, R.4
Abe, H.5
-
87
-
-
0020660038
-
Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas
-
Shichiri M., Kawamori R., Goriya Y., Yamasaki Y., Nomura M., Hakui N., Abe H. Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas. Diabetologia. 24:1983;179-184.
-
(1983)
Diabetologia
, vol.24
, pp. 179-184
-
-
Shichiri, M.1
Kawamori, R.2
Goriya, Y.3
Yamasaki, Y.4
Nomura, M.5
Hakui, N.6
Abe, H.7
-
88
-
-
0029294501
-
Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate
-
Nishida K., Sakakida M., Ichinose K., Uemura T., Uehara M., Kajiwara K., Miyata T., Shichiri M., Ishihara K., Nakabayashi N. Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate. Medical Progress Through Technology. 21:1995;91-103.
-
(1995)
Medical Progress Through Technology
, vol.21
, pp. 91-103
-
-
Nishida, K.1
Sakakida, M.2
Ichinose, K.3
Uemura, T.4
Uehara, M.5
Kajiwara, K.6
Miyata, T.7
Shichiri, M.8
Ishihara, K.9
Nakabayashi, N.10
-
89
-
-
0022913659
-
Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs
-
Claremont D.J., Sambrook I.E., Penton C., Pickup J.C. Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs. Diabetologia. 29:1986;817-821.
-
(1986)
Diabetologia
, vol.29
, pp. 817-821
-
-
Claremont, D.J.1
Sambrook, I.E.2
Penton, C.3
Pickup, J.C.4
-
90
-
-
0027770788
-
Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man
-
Pickup J.C., Claremont D.J., Shaw G.W. Responses and calibration of amperometric glucose sensors implanted in the subcutaneous tissue of man. Acta Diabetologia. 30:1993;143-148.
-
(1993)
Acta Diabetologia
, vol.30
, pp. 143-148
-
-
Pickup, J.C.1
Claremont, D.J.2
Shaw, G.W.3
-
91
-
-
0021747298
-
Closed-loop glycaemic control with a wearable artificial endocrine pancreas: Variations in daily insulin requirements to glycaemic response
-
Shichiri M., Kawamori R., Hakui N., Yamasaki Y., Abe H. Closed-loop glycaemic control with a wearable artificial endocrine pancreas: variations in daily insulin requirements to glycaemic response. Diabetes. 33:1984;1200-1202.
-
(1984)
Diabetes
, vol.33
, pp. 1200-1202
-
-
Shichiri, M.1
Kawamori, R.2
Hakui, N.3
Yamasaki, Y.4
Abe, H.5
-
92
-
-
0024514006
-
In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method
-
Bruckel J., Kerner W., Zier H., Steinbach G., Pfeiffer E.F. In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method. Klin Wochenschr. 67:1989;491-495.
-
(1989)
Klin Wochenschr
, vol.67
, pp. 491-495
-
-
Bruckel, J.1
Kerner, W.2
Zier, H.3
Steinbach, G.4
Pfeiffer, E.F.5
-
93
-
-
0023580011
-
Assesment of subcutaneous glucose concentration: Validation of the wick technique as a reference for implanted eletrochemical sensors in normal and diabetic dogs
-
Fischer U., Ertle R., Abel P., Brunstein E., Hahn von Dorsche H., Freyse E.J. Assesment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted eletrochemical sensors in normal and diabetic dogs. Diabetologia. 30:1987;940-945.
-
(1987)
Diabetologia
, vol.30
, pp. 940-945
-
-
Fischer, U.1
Ertle, R.2
Abel, P.3
Brunstein, E.4
Hahn Von Dorsche, H.5
Freyse, E.J.6
-
94
-
-
0024459574
-
Wick technique: Reference method for implanted glucose sensors
-
Fischer U., Ertle R., Rebrin K., Freyse E.J. Wick technique: reference method for implanted glucose sensors. Artif Organs. 13:1989;453-458.
-
(1989)
Artif Organs
, vol.13
, pp. 453-458
-
-
Fischer, U.1
Ertle, R.2
Rebrin, K.3
Freyse, E.J.4
-
95
-
-
0024576715
-
In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle material
-
Vehlo G., Froguel P., Sternberg R., Thevenot D.R., Reach G. In vitro and in vivo stability of electrode potentials in needle-type glucose sensors. Influence of needle material. Diabetes. 38:1989;164-171.
-
(1989)
Diabetes
, vol.38
, pp. 164-171
-
-
Vehlo, G.1
Froguel, P.2
Sternberg, R.3
Thevenot, D.R.4
Reach, G.5
-
96
-
-
0024041578
-
A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors
-
McKean B.D., Gough D.A. A telemetry-instrumentation system for chronically implanted glucose and oxygen sensors. IEEE Trans Biomed Eng. 35:1988;526-532.
-
(1988)
IEEE Trans Biomed Eng
, vol.35
, pp. 526-532
-
-
McKean, B.D.1
Gough, D.A.2
-
97
-
-
0023898403
-
An amperometric needle-type glucose sensor tested in rats and man
-
Matthews D.R., Bown E., Beck T.W., Plotkin E., Lock L., Gosden E., Wickham M. An amperometric needle-type glucose sensor tested in rats and man. Diabetic Med. 5:1988;248-252.
-
(1988)
Diabetic Med
, vol.5
, pp. 248-252
-
-
Matthews, D.R.1
Bown, E.2
Beck, T.W.3
Plotkin, E.4
Lock, L.5
Gosden, E.6
Wickham, M.7
-
98
-
-
0028872278
-
Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors
-
Quinn C.P., Pishko M.V., Schmidtke D.W., Ishikawa M., Wagner J.G., Raskin P., Hubbell J.A., Heller A. Kinetics of glucose delivery to subcutaneous tissue in rats measured with 0.3-mm amperometric microsensors. Am J Physiol. 269:1995;E155-E161.
-
(1995)
Am J Physiol
, vol.269
-
-
Quinn, C.P.1
Pishko, M.V.2
Schmidtke, D.W.3
Ishikawa, M.4
Wagner, J.G.5
Raskin, P.6
Hubbell, J.A.7
Heller, A.8
-
99
-
-
0028279952
-
Amperometric biosensor for in vivo glucose sensing based on glucose oxidase immobilized in a redox hydrogel
-
Linke B., Kerner W., Kiwit M., Pishko M., Heller A. Amperometric biosensor for in vivo glucose sensing based on glucose oxidase immobilized in a redox hydrogel. Biosens Bioelectr. 9:1994;151-158.
-
(1994)
Biosens Bioelectr
, vol.9
, pp. 151-158
-
-
Linke, B.1
Kerner, W.2
Kiwit, M.3
Pishko, M.4
Heller, A.5
-
100
-
-
0020134817
-
Implanted electroenzymatic glucose sensors
-
Clark L.C. Jr., Duggan C.A. Implanted electroenzymatic glucose sensors. Diabetes Care. 5:(3):1982;174-180.
-
(1982)
Diabetes Care
, vol.5
, Issue.3
, pp. 174-180
-
-
Clark L.C., Jr.1
Duggan, C.A.2
-
101
-
-
0029053116
-
Integrated implantable device for long-term glucose monitoring
-
Wilkins E., Atanasov P. Integrated implantable device for long-term glucose monitoring. Biosens Bioelectr. 10:1995;485-494.
-
(1995)
Biosens Bioelectr
, vol.10
, pp. 485-494
-
-
Wilkins, E.1
Atanasov, P.2
-
102
-
-
0031914389
-
Enhanced, simplified glucose sensors: Long-term clinical application of wearable artificial endocrine pancreas
-
Shichiri M., Sakakida M., Nishida K., Shimoda S. Enhanced, simplified glucose sensors: long-term clinical application of wearable artificial endocrine pancreas. Artif Organs. 22:(1):1998;32-42.
-
(1998)
Artif Organs
, vol.22
, Issue.1
, pp. 32-42
-
-
Shichiri, M.1
Sakakida, M.2
Nishida, K.3
Shimoda, S.4
-
103
-
-
0023131817
-
On the way to the automated (blood) glucose regulation in diabetes: The dark past, the grey present and the rosty future
-
Pfeiffer E.F. On the way to the automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosty future. Diabetologia. 30:1987;51-65.
-
(1987)
Diabetologia
, vol.30
, pp. 51-65
-
-
Pfeiffer, E.F.1
|