The artifcial pancreas: How sweet engineering will solve bitter problems

Author keywords

Artifcial; Closed loop; Control; Diabetes; Glucose; Pancreas

Indexed keywords


EID: 34248162815     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680700100112     Document Type: Review
Times cited : (66)

References (90)
  • 1
    • 0028218970 scopus 로고
    • Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients
    • Hashiguchi Y, Sakakida M, Nishida K, Uemura T, Kajiwara K, Shichiri M.: Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method. Long-term subcutaneous tissue glucose monitoring in ambulatory diabetic patients. Diabetes Care. 1994;17:387-396.
    • (1994) Diabetes Care. , vol.17 , pp. 387-396
    • Hashiguchi, Y.1    Sakakida, M.2    Nishida, K.3    Uemura, T.4    Kajiwara, K.5    Shichiri, M.6
  • 2
    • 0031914389 scopus 로고    scopus 로고
    • Enhanced, simplifed glucose sensors: Long-term clinical application of wearable artifcial endocrine pancreas
    • Shichiri M, Sakakida M, Nishida K, Shimoda S.: Enhanced, simplifed glucose sensors: long-term clinical application of wearable artifcial endocrine pancreas. Artif Organs. 1998;22:32-42.
    • (1998) Artif Organs. , vol.22 , pp. 32-42
    • Shichiri, M.1    Sakakida, M.2    Nishida, K.3    Shimoda, S.4
  • 3
    • 0004644027 scopus 로고    scopus 로고
    • Development of algorithms for feedback-controlled subcutaneous insulin infusion with insulin lispro
    • Kalatz B, Hoss U, Gessler R, Sternberg F, Lohmann S, Salgado M et al.: Development of algorithms for feedback-controlled subcutaneous insulin infusion with insulin lispro. Acta Diabetol. 1999;36:215.
    • (1999) Acta Diabetol. , vol.36 , pp. 215
    • Kalatz, B.1    Hoss, U.2    Gessler, R.3    Sternberg, F.4    Lohmann, S.5    Salgado, M.6
  • 7
    • 20144379329 scopus 로고    scopus 로고
    • Use of subcutaneous glucose measurements to drive real-time algorithmdirected insulin infusion recommendations
    • Galley P, Wagner R, Buck H, Weinert S, Bousamra S, Long J et al.: Use of subcutaneous glucose measurements to drive real-time algorithmdirected insulin infusion recommendations. Diabetes Technol Ther. 2004;6:245-246.
    • (2004) Diabetes Technol Ther. , vol.6 , pp. 245-246
    • Galley, P.1    Wagner, R.2    Buck, H.3    Weinert, S.4    Bousamra, S.5    Long, J.6
  • 8
    • 23644442506 scopus 로고    scopus 로고
    • Effcacy of closed-loop control of blood glucose based on an implantable iv sensor and intraperitoneal pump
    • Renard E, Panteleon AE, Leong P, Han J, Kolopp M, Miller M et al. Effcacy of closed-loop control of blood glucose based on an implantable i.v. sensor and intraperitoneal pump. Diabetes. 2004;53:A114.
    • (2004) Diabetes. , vol.53
    • Renard, E.1    Panteleon, A.E.2    Leong, P.3    Han, J.4    Kolopp, M.5    Miller, M.6
  • 10
    • 33645091858 scopus 로고    scopus 로고
    • Continuous automated insulin delivery based on subcutaneous glucose sensing and an external insulin pump
    • Steil GM, Rebrin K, Hariri F, Chen Y, Darwin C, Saad M.: Continuous automated insulin delivery based on subcutaneous glucose sensing and an external insulin pump. Diabetes. 2004;53:A2.
    • (2004) Diabetes. , vol.53
    • Steil, G.M.1    Rebrin, K.2    Hariri, F.3    Chen, Y.4    Darwin, C.5    Saad, M.6
  • 11
    • 33645079860 scopus 로고    scopus 로고
    • Minimally invasive control loop system for SC-SC control on patients with type 1 diabetes
    • Vering T.: Minimally invasive control loop system for SC-SC control on patients with type 1 diabetes. Diabetes Technol Ther. 2004;6:278.
    • (2004) Diabetes Technol Ther. , vol.6 , pp. 278
    • Vering, T.1
  • 12
    • 20544440581 scopus 로고    scopus 로고
    • An implantable subcutaneous glucose sensor array in ketosis-prone rats: Closed-loop glycemic control
    • Ward WK, Wood MD, Casey HM, Quinn MJ, Federiuk IF: An implantable subcutaneous glucose sensor array in ketosis-prone rats: closed-loop glycemic control. Artif Organs. 2005;29:131-143.
    • (2005) Artif Organs. , vol.29 , pp. 131-143
    • Ward, W.K.1    Wood, M.D.2    Casey, H.M.3    Quinn, M.J.4    Federiuk, I.F.5
  • 13
    • 0032962321 scopus 로고    scopus 로고
    • A model-based algorithm for blood glucose control in type I diabetic patients
    • Parker RS, Doyle FJ 3rd, Peppas NA: A model-based algorithm for blood glucose control in type I diabetic patients. IEEE Trans Biomed Eng. 1999;46:148-157.
    • (1999) IEEE Trans Biomed Eng. , vol.46 , pp. 148-157
    • Parker, R.S.1    Doyle III, F.J.2    Peppas, N.A.3
  • 15
    • 14844350443 scopus 로고    scopus 로고
    • Modeling insulin action for development of a closed-loop artifcial pancreas
    • Steil GM, Clark B, Kanderian S, Rebrin K: Modeling insulin action for development of a closed-loop artifcial pancreas. Diabetes Technol Ther. 2005;7:94-108.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 94-108
    • Steil, G.M.1    Clark, B.2    Kanderian, S.3    Rebrin, K.4
  • 17
    • 0242300689 scopus 로고    scopus 로고
    • A clinician's perspective on some of the challenges in "closing the loop"
    • Wolpert HA: A clinician's perspective on some of the challenges in "closing the loop". Diabetes Technol Ther. 2003;5:843-846.
    • (2003) Diabetes Technol Ther. , vol.5 , pp. 843-846
    • Wolpert, H.A.1
  • 20
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Rebrin K, Steil GM, Van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol. 1999;277(3 Pt 1):E561-71.
    • (1999) Am J Physiol. , vol.277 , Issue.3 PART 1
    • Rebrin, K.1    Steil, G.M.2    Van Antwerp, W.P.3    Mastrototaro, J.J.4
  • 21
    • 18144421498 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Roadmap for 21st century diabetes therapy
    • Klonoff DC.: Continuous glucose monitoring: roadmap for 21st century diabetes therapy. Diabetes Care. 2005;28:1231-1239.
    • (2005) Diabetes Care. , vol.28 , pp. 1231-1239
    • Klonoff, D.C.1
  • 22
    • 27644481443 scopus 로고    scopus 로고
    • Real-time continuous glucose monitor use and patient selection: What have we learned and where are we going?
    • Wilson DM, Block J: Real-time continuous glucose monitor use and patient selection: what have we learned and where are we going? Diabetes Technol Ther. 2005;7:788-791.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 788-791
    • Wilson, D.M.1    Block, J.2
  • 23
    • 0033811433 scopus 로고    scopus 로고
    • Afferent signals regulating food intake
    • Bray GA.: Afferent signals regulating food intake. Proc Nutr Soc. 2000;59:373-384.
    • (2000) Proc Nutr Soc. , vol.59 , pp. 373-384
    • Bray, G.A.1
  • 24
    • 13544271146 scopus 로고    scopus 로고
    • Current status and future of implantable insulin pumps for the treatment of diabetes
    • Catargi B.: Current status and future of implantable insulin pumps for the treatment of diabetes. Expert Rev Med Devices. 2004;1:181-185.
    • (2004) Expert Rev Med Devices. , vol.1 , pp. 181-185
    • Catargi, B.1
  • 25
    • 0035955720 scopus 로고    scopus 로고
    • Activities of monomeric insulin analogs at position A8 are uncorrelated with their thermodynamic stabilities
    • Weiss MA, Hua QX, Jia W, Nakagawa SH, Chu YC, Hu SQ, Katsoyannis PG.: Activities of monomeric insulin analogs at position A8 are uncorrelated with their thermodynamic stabilities. J Biol Chem. 2001;276:40018-40024.
    • (2001) J Biol Chem. , vol.276 , pp. 40018-40024
    • Weiss, M.A.1    Hua, Q.X.2    Jia, W.3    Nakagawa, S.H.4    Chu, Y.C.5    Hu, S.Q.6    Katsoyannis, P.G.7
  • 26
    • 9144237470 scopus 로고    scopus 로고
    • Combined improvements in implantable pump technology and insulin stability allow safe and effective long term intraperitoneal insulin delivery in type 1 diabetic patients: The EVADIAC experience
    • EVADIAC Study Group
    • Gin H, Renard E, Melki V, Boivin S, Schaepelynck-Belicar P, Guerci B, Selam JL, Brun JM, Riveline JP, Estour B, Catargi B; EVADIAC Study Group. Combined improvements in implantable pump technology and insulin stability allow safe and effective long term intraperitoneal insulin delivery in type 1 diabetic patients: the EVADIAC experience. Diabetes Metab. 2003;29:602-607.
    • (2003) Diabetes Metab. , vol.29 , pp. 602-607
    • Gin, H.1    Renard, E.2    Melki, V.3    Boivin, S.4    Schaepelynck-Belicar, P.5    Guerci, B.6    Selam, J.L.7    Brun, J.M.8    Riveline, J.P.9    Estour, B.10    Catargi, B.11
  • 27
    • 33750118804 scopus 로고    scopus 로고
    • Position statement: Continuous subcutaneous insulin infusion in very young children with type 1 diabetes
    • Lawson-Wilkins Drug and Therapeutics Committee
    • Eugster EA, Francis G; Lawson-Wilkins Drug and Therapeutics Committee. Position statement: Continuous subcutaneous insulin infusion in very young children with type 1 diabetes. Pediatrics. 2006;118:1244-1249.
    • (2006) Pediatrics. , vol.118 , pp. 1244-1249
    • Eugster, E.A.1    Francis, G.2
  • 29
    • 33646597263 scopus 로고    scopus 로고
    • Insulin treatment in type 1 diabetes
    • Bolli GB. Insulin treatment in type 1 diabetes. Endocr Pract. 2006;12 Suppl 1:105-109.
    • (2006) Endocr Pract. , vol.12 , Issue.SUPPL. 1 , pp. 105-109
    • Bolli, G.B.1
  • 30
    • 0347624612 scopus 로고    scopus 로고
    • Modeling betacell insulin secretion-implications for closed-loop glucose homeostasis
    • Steil GM, Rebrin K, Janowski R, Darwin C, Saad MF: Modeling betacell insulin secretion-implications for closed-loop glucose homeostasis. Diabetes Technol Ther. 2003;5:953-964.
    • (2003) Diabetes Technol Ther. , vol.5 , pp. 953-964
    • Steil, G.M.1    Rebrin, K.2    Janowski, R.3    Darwin, C.4    Saad, M.F.5
  • 33
    • 14844348734 scopus 로고    scopus 로고
    • The extended Kalman flter for continuous glucose monitoring
    • Knobbe EJ, Buckingham B.: The extended Kalman flter for continuous glucose monitoring. Diabetes Technol Ther. 2005;7:15-27.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 34
    • 0035345425 scopus 로고    scopus 로고
    • Which Threshold to Detect Hypoglycemia?: Value of receiveroperator curve analysis to fnd a compromise between sensitivity and specifcity
    • Reach G.: Which Threshold to Detect Hypoglycemia?: Value of receiveroperator curve analysis to fnd a compromise between sensitivity and specifcity. Diabetes Care. 2001;24:803-804.
    • (2001) Diabetes Care. , vol.24 , pp. 803-804
    • Reach, G.1
  • 35
    • 11144284317 scopus 로고    scopus 로고
    • Rational use of insulin analogues in the treatment of type 1 diabetes mellitus
    • Bolli GB: Rational use of insulin analogues in the treatment of type 1 diabetes mellitus. Pediatr Endocrinol Rev. 2003;1:9-21.
    • (2003) Pediatr Endocrinol Rev. , vol.1 , pp. 9-21
    • Bolli, G.B.1
  • 36
    • 14844351848 scopus 로고    scopus 로고
    • A critical assessment of algorithms and challenges in the development of a closed-loop artifcial pancreas
    • Bequette BW: A critical assessment of algorithms and challenges in the development of a closed-loop artifcial pancreas. Diabetes Technol Ther. 2005;7:28-47.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 28-47
    • Bequette, B.W.1
  • 37
    • 0014336473 scopus 로고
    • Dynamics of insulin secretion by the perfused rat pancreas
    • Curry DL, Bennett LL, Grodsky GM: Dynamics of Insulin Secretion by the Perfused Rat Pancreas. Endocrinology. 1968;83:572-584.
    • (1968) Endocrinology. , vol.83 , pp. 572-584
    • Curry, D.L.1    Bennett, L.L.2    Grodsky, G.M.3
  • 38
    • 2342563789 scopus 로고    scopus 로고
    • Evaluation of insulin sensitivity and betacell function indexes obtained from minimal model analysis of a meal tolerance test
    • Steil GM, Hwu CM, Janowski R, Hariri F, Jinagouda S, Darwin C, Tadros S, Rebrin K, Saad MF: Evaluation of insulin sensitivity and betacell function indexes obtained from minimal model analysis of a meal tolerance test. Diabetes. 2004;53:1201-1207.
    • (2004) Diabetes. , vol.53 , pp. 1201-1207
    • Steil, G.M.1    Hwu, C.M.2    Janowski, R.3    Hariri, F.4    Jinagouda, S.5    Darwin, C.6    Tadros, S.7    Rebrin, K.8    Saad, M.F.9
  • 40
    • 33747056641 scopus 로고    scopus 로고
    • Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system
    • Panteleon AE, Loutseiko M, Steil GM, Rebrin K. Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system. Diabetes. 2006;55:1995-2000.
    • (2006) Diabetes. , vol.55 , pp. 1995-2000
    • Panteleon, A.E.1    Loutseiko, M.2    Steil, G.M.3    Rebrin, K.4
  • 41
    • 31744441732 scopus 로고    scopus 로고
    • Modeling, identifcation and nonlinear model predictive control of type I diabetic patient
    • Schlotthauer G, Gamero LG, Torres ME, Nicolini GA.: Modeling, identifcation and nonlinear model predictive control of type I diabetic patient. Med Eng Phys. 2006;28:240-250.
    • (2006) Med Eng Phys. , vol.28 , pp. 240-250
    • Schlotthauer, G.1    Gamero, L.G.2    Torres, M.E.3    Nicolini, G.A.4
  • 42
    • 17144401811 scopus 로고    scopus 로고
    • A fuzzy logic based closed-loop control system for blood glucose level regulation in diabetics
    • Ibbini MS, Masadeh MA.: A fuzzy logic based closed-loop control system for blood glucose level regulation in diabetics. J Med Eng Technol. 2005;29:64-69.
    • (2005) J Med Eng Technol. , vol.29 , pp. 64-69
    • Ibbini, M.S.1    Masadeh, M.A.2
  • 43
    • 0027690505 scopus 로고
    • A robust controller for insulin pumps based on H-infnity theory
    • Kienitz HK, Yoneyama T.: A robust controller for insulin pumps based on H-infnity theory. IEEE Trans Biomed Eng. 1993;40:1133-1137.
    • (1993) IEEE Trans Biomed Eng. , vol.40 , pp. 1133-1137
    • Kienitz, H.K.1    Yoneyama, T.2
  • 44
    • 26444463718 scopus 로고    scopus 로고
    • Optimal H infnity insulin injection control for blood glucose regulation in diabetic patients
    • Chee F, Savkin AV, Fernando TL, Nahavandi S.: Optimal H infnity insulin injection control for blood glucose regulation in diabetic patients. IEEE Trans Biomed Eng. 2005;52:1625-1631.
    • (2005) IEEE Trans Biomed Eng. , vol.52 , pp. 1625-1631
    • Chee, F.1    Savkin, A.V.2    Fernando, T.L.3    Nahavandi, S.4
  • 45
    • 4143144487 scopus 로고    scopus 로고
    • New products. A pump/meter duo. Pump and meter talk via radio waves
    • Kordella T.: New products. A pump/meter duo. Pump and meter talk via radio waves. Diabetes Forecast. 2003;56:45.
    • (2003) Diabetes Forecast. , vol.56 , pp. 45
    • Kordella, T.1
  • 46
    • 29244468290 scopus 로고    scopus 로고
    • Drug/device combinations for local drug therapies and infection prophylaxis
    • Wu P, Grainger DW: Drug/device combinations for local drug therapies and infection prophylaxis. Biomaterials. 2006;27:2450-67.
    • (2006) Biomaterials. , vol.27 , pp. 2450-2467
    • Wu, P.1    Grainger, D.W.2
  • 47
    • 33748412631 scopus 로고    scopus 로고
    • Evaluation of factors affecting CGMS calibration
    • Diabetes Research In Children Network Direcnet Study Group; Buckingham BA, Kollman C, Beck R, Kalajian A, Fiallo-Scharer R, Tansey MJ, Fox LA, Wilson DM
    • Weinzimer SA, Ruedy KJ, Tamborlane W V. Evaluation of factors affecting CGMS calibration. Diabetes Research In Children Network (Direcnet) Study Group; Buckingham BA, Kollman C, Beck R, Kalajian A, Fiallo-Scharer R, Tansey MJ, Fox LA, Wilson DM. Diabetes Technol Ther. 2006;8:318-325.
    • (2006) Diabetes Technol Ther. , vol.8 , pp. 318-325
    • Weinzimer, S.A.1    Ruedy, K.J.2    Tamborlane, W.V.3
  • 48
    • 33745844749 scopus 로고    scopus 로고
    • Current developments using emerging transdermal technologies in physical enhancement methods
    • Nanda A, Nanda S, Ghilzai NM. Current developments using emerging transdermal technologies in physical enhancement methods. Curr Drug Deliv. 2006;3:233-242.
    • (2006) Curr Drug Deliv. , vol.3 , pp. 233-242
    • Nanda, A.1    Nanda, S.2    Ghilzai, N.M.3
  • 49
    • 1842583012 scopus 로고    scopus 로고
    • Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: The guardian continuous monitoring system
    • Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, Gross T, Mastrototaro J. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Diabetes Technol Ther. 2004;6:105-113.
    • (2004) Diabetes Technol Ther. , vol.6 , pp. 105-113
    • Bode, B.1    Gross, K.2    Rikalo, N.3    Schwartz, S.4    Wahl, T.5    Page, C.6    Gross, T.7    Mastrototaro, J.8
  • 51
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L: Improvement in Glycemic Excursions With a Transcutaneous, Real-Time Continuous Glucose Sensor: A randomized controlled trial. Diabetes Care. 2006;29:44-50.
    • (2006) Diabetes Care. , vol.29 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 52
    • 0242363717 scopus 로고    scopus 로고
    • A continuous glucose sensor based on wired enzyme technology - Results from a 3-day trial in patients with type 1 diabetes
    • Feldman B, Brazg R, Schwartz S, Weinstein R.: A continuous glucose sensor based on wired enzyme technology - results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther. 2003;5:769-779.
    • (2003) Diabetes Technol Ther. , vol.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3    Weinstein, R.4
  • 53
    • 34248138343 scopus 로고    scopus 로고
    • The need for performance standards for continuous glucose monitors
    • Nichols J, Klonoff D. The Need for Performance Standards for Continuous Glucose Monitors. J Diabetes Sci Technol. 2007;1:92-94
    • (2007) J Diabetes Sci Technol. , vol.1 , pp. 92-94
    • Nichols, J.1    Klonoff, D.2
  • 54
    • 0036518602 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion at 25 years: Evidence base for the expanding use of insulin pump therapy in type 1 diabetes
    • Pickup J, Keen H.: Continuous subcutaneous insulin infusion at 25 years: evidence base for the expanding use of insulin pump therapy in type 1 diabetes. Diabetes Care. 2002;25:593-598.
    • (2002) Diabetes Care. , vol.25 , pp. 593-598
    • Pickup, J.1    Keen, H.2
  • 56
    • 9144237470 scopus 로고    scopus 로고
    • Combined improvements in implantable pump technology and insulin stability allow safe and effective long term intraperitoneal insulin delivery in type 1 diabetic patients: The EVADIAC experience
    • EVADIAC Study Group.
    • Gin H, Renard E, Melki V, Boivin S, Schaepelynck-Belicar P, Guerci B, Selam JL, Brun JM, Riveline JP, Estour B, Catargi B; EVADIAC Study Group.: Combined improvements in implantable pump technology and insulin stability allow safe and effective long term intraperitoneal insulin delivery in type 1 diabetic patients: the EVADIAC experience. Diabetes Metab. 2003;29:602-607.
    • (2003) Diabetes Metab. , vol.29 , pp. 602-607
    • Gin, H.1    Renard, E.2    Melki, V.3    Boivin, S.4    Schaepelynck-Belicar, P.5    Guerci, B.6    Selam, J.L.7    Brun, J.M.8    Riveline, J.P.9    Estour, B.10    Catargi, B.11
  • 57
    • 0035135478 scopus 로고    scopus 로고
    • Clinical evaluation of a newly designed compliant side port catheter for an insulin implantable pump: The evadiac experience
    • EVADIAC Study Group.
    • Gin H, Melki V, Guerci B, Catargi B; EVADIAC Study Group.: Clinical Evaluation of a Newly Designed Compliant Side Port Catheter for an Insulin Implantable Pump: The EVADIAC experience, Diabetes Care. 2001;24:175.
    • (2001) Diabetes Care. , vol.24 , pp. 175
    • Gin, H.1    Melki, V.2    Guerci, B.3    Catargi, B.4
  • 58
    • 0027955099 scopus 로고
    • The evadiac study group. Evaluation of active implants in diabetes society
    • French multicentre experience of implantable insulin pumps
    • Broussolle C, Jeandidier N, Hanaire-Broutin H.: French multicentre experience of implantable insulin pumps. The EVADIAC Study Group. Evaluation of Active Implants in Diabetes Society. Lancet. 1994;343:514-515.
    • (1994) Lancet. , vol.343 , pp. 514-515
    • Broussolle, C.1    Jeandidier, N.2    Hanaire-Broutin, H.3
  • 59
    • 0842310048 scopus 로고    scopus 로고
    • Suppression of endogenous glucose production by mild hyperinsulinemia during exercise is determined predominantly by portal venous insulin
    • Camacho RC, Pencek RR, Lacy DB, James FD, Wasserman DH.: Suppression of endogenous glucose production by mild hyperinsulinemia during exercise is determined predominantly by portal venous insulin. Diabetes. 2004;53:285-293.
    • (2004) Diabetes. , vol.53 , pp. 285-293
    • Camacho, R.C.1    Pencek, R.R.2    Lacy, D.B.3    James, F.D.4    Wasserman, D.H.5
  • 60
    • 32144460482 scopus 로고    scopus 로고
    • Future developments in insulin pump therapy: Progression from continuous subcutaneous insulin infusion to a sensorpump system
    • Fisher LK, Halvorson M: Future developments in insulin pump therapy: progression from continuous subcutaneous insulin infusion to a sensorpump system. Diabetes Educ. 2006;32(Suppl 1):47S-52S.
    • (2006) Diabetes Educ. , vol.32 , Issue.SUPPL. 1
    • Fisher, L.K.1    Halvorson, M.2
  • 61
    • 0038285653 scopus 로고    scopus 로고
    • A bolus calculator is an effective means of controlling postprandial glycemia in patients on insulin pump therapy
    • Gross TM, Kayne D, King A, Rother C, Juth S.: A bolus calculator is an effective means of controlling postprandial glycemia in patients on insulin pump therapy. Diabetes Technol Ther. 2003;5:365-369.
    • (2003) Diabetes Technol Ther. , vol.5 , pp. 365-369
    • Gross, T.M.1    Kayne, D.2    King, A.3    Rother, C.4    Juth, S.5
  • 62
    • 31144432394 scopus 로고    scopus 로고
    • Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes
    • Cook CB, McMichael JP, Dunbar VG, Lieberman R. Description and preliminary evaluation of a Multiagent Intelligent Dosing System (MAIDS) to manage combination insulin-oral agent therapy in type 2 diabetes. Diabetes Technol Ther. 2005;7:937-947.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 937-947
    • Cook, C.B.1    McMichael, J.P.2    Dunbar, V.G.3    Lieberman, R.4
  • 63
    • 1442324399 scopus 로고    scopus 로고
    • Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes
    • Garg SK, Schwartz S, Edelman SV.: Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. Diabetes Care. 2004;27:734-738.
    • (2004) Diabetes Care. , vol.27 , pp. 734-738
    • Garg, S.K.1    Schwartz, S.2    Edelman, S.V.3
  • 64
    • 0034468370 scopus 로고    scopus 로고
    • Serum fructosamine as a screening test for type 2 diabetes
    • Klonoff DC: Serum fructosamine as a screening test for type 2 diabetes. Diabetes Technol Ther. 2000;2:537-539.
    • (2000) Diabetes Technol Ther. , vol.2 , pp. 537-539
    • Klonoff, D.C.1
  • 65
    • 3342932958 scopus 로고    scopus 로고
    • Circulating 1, 5-anhydroglucitol levels in adult patients with diabetes refect longitudinal changes of glycemia: A U. S. Trial of the GlycoMark assay
    • Gill JB, Cole TG, Nowatzke W, Houghton S, Ammirati EB, Gautille T, Sarno MJ.: Circulating 1, 5-anhydroglucitol levels in adult patients with diabetes refect longitudinal changes of glycemia: a U. S. trial of the GlycoMark assay. Diabetes Care. 2004;27:1859-1865.
    • (2004) Diabetes Care. , vol.27 , pp. 1859-1865
    • Gill, J.B.1    Cole, T.G.2    Nowatzke, W.3    Houghton, S.4    Ammirati, E.B.5    Gautille, T.6    Sarno, M.J.7
  • 66
    • 33645732339 scopus 로고    scopus 로고
    • Glycemic variability: A hemoglobin A1cindependent risk factor for diabetic complications
    • Brownlee M, Hirsch IB. Glycemic variability: a hemoglobin A1cindependent risk factor for diabetic complications. JAMA. 2006;295:1707-1708.
    • (2006) JAMA. , vol.295 , pp. 1707-1708
    • Brownlee, M.1    Hirsch, I.B.2
  • 67
    • 14844339014 scopus 로고    scopus 로고
    • Grading system to assess clinical performance of closed-loop glucose control
    • Chassin LJ, Wilinska ME, Hovorka R.: Grading system to assess clinical performance of closed-loop glucose control. Diabetes Technol Ther. 2005;7:72-82.
    • (2005) Diabetes Technol Ther. , vol.7 , pp. 72-82
    • Chassin, L.J.1    Wilinska, M.E.2    Hovorka, R.3
  • 69
    • 0007424620 scopus 로고
    • Automation control of blood sugar: A servomechanism for glucose monitoring
    • Kadish AH: Automation control of blood sugar: a servomechanism for glucose monitoring. Am J Med Electron. 1964;39:82-86.
    • (1964) Am J Med Electron. , vol.39 , pp. 82-86
    • Kadish, A.H.1
  • 72
    • 0016259390 scopus 로고
    • The artifcial beta cell-A continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system)
    • Pfeiffer EF, Thum C, Clemens AH: The artifcial beta cell-a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). Horm Metab Res. 1974;6:339-42.
    • (1974) Horm Metab Res. , vol.6 , pp. 339-342
    • Pfeiffer, E.F.1    Thum, C.2    Clemens, A.H.3
  • 73
    • 0017849325 scopus 로고
    • Importance of insulin secretion based on the rate of change in blood glucose concentration in glucose tolerance, assessed by the artifcial beta cell
    • Kawamori R, Shichiri M, Goriya Y, Yamasaki Y, Shigeta Y, Abe H.: Importance of insulin secretion based on the rate of change in blood glucose concentration in glucose tolerance, assessed by the artifcial beta cell. Acta Endocrinol (Copenh). 1978;87:339-351.
    • (1978) Acta Endocrinol (Copenh). , vol.87 , pp. 339-351
    • Kawamori, R.1    Shichiri, M.2    Goriya, Y.3    Yamasaki, Y.4    Shigeta, Y.5    Abe, H.6
  • 74
    • 0018748133 scopus 로고
    • Normalization of the paradoxic secretion of glucagon in diabetics who were controlled by the artifcial beta cell
    • Shichiri M, Kawamori R, Abe H.: Normalization of the paradoxic secretion of glucagon in diabetics who were controlled by the artifcial beta cell. Diabetes. 1979;28:272-275.
    • (1979) Diabetes. , vol.28 , pp. 272-275
    • Shichiri, M.1    Kawamori, R.2    Abe, H.3
  • 75
    • 0018765241 scopus 로고
    • The development of an artifcial beta cell system and its validation in depancreatized dogs: The physiological restoration of blood glucose homeostasis
    • Goriya Y, Kawamori R, Shichiri M, Abe H.: The development of an artifcial beta cell system and its validation in depancreatized dogs: the physiological restoration of blood glucose homeostasis. Med Prog Technol. 1979;6:99-108.
    • (1979) Med Prog Technol. , vol.6 , pp. 99-108
    • Goriya, Y.1    Kawamori, R.2    Shichiri, M.3    Abe, H.4
  • 77
    • 0027946726 scopus 로고
    • Glucose clamps with the Biostator: A critical reappraisal
    • Heinemann L, Ampudia-Blasco FJ.: Glucose clamps with the Biostator: a critical reappraisal. Horm Metab Res. 1994;26:579-583.
    • (1994) Horm Metab Res. , vol.26 , pp. 579-583
    • Heinemann, L.1    Ampudia-Blasco, F.J.2
  • 78
  • 80
    • 3042563903 scopus 로고    scopus 로고
    • Evaluation of glucose controllers in virtual environment: Methodology and sample application
    • Chassin LJ, Wilinska ME, Hovorka R.: Evaluation of glucose controllers in virtual environment: methodology and sample application. Artif Intell Med. 2004;32:171-181.
    • (2004) Artif Intell Med. , vol.32 , pp. 171-181
    • Chassin, L.J.1    Wilinska, M.E.2    Hovorka, R.3
  • 84
    • 3042513992 scopus 로고    scopus 로고
    • MPC algorithm controls blood glucose in patients with type 1 diabetes mellitus under fasting conditions using the IV-SC route
    • Schaller HC, Bodenlenz M, Schaupp L, Plank J, Wach P, Pieber TR et al.: MPC algorithm controls blood glucose in patients with type 1 diabetes mellitus under fasting conditions using the IV-SC route. Diabetes Technol Ther. 2002;4:234.
    • (2002) Diabetes Technol Ther. , vol.4 , pp. 234
    • Schaller, H.C.1    Bodenlenz, M.2    Schaupp, L.3    Plank, J.4    Wach, P.5    Pieber, T.R.6
  • 86
    • 33645050932 scopus 로고    scopus 로고
    • On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed-loop control of glucose: Evaluation under fasting conditions in patients with type 1 diabetes
    • Schaller HC, Schaupp L, Bodenlenz M, Wilinska ME, Chassin LJ, Wach P et al. On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed-loop control of glucose: evaluation under fasting conditions in patients with type 1 diabetes. Diabet Med. 2006;23:90-93.
    • (2006) Diabet Med. , vol.23 , pp. 90-93
    • Schaller, H.C.1    Schaupp, L.2    Bodenlenz, M.3    Wilinska, M.E.4    Chassin, L.J.5    Wach, P.6
  • 87
    • 33645051466 scopus 로고    scopus 로고
    • Continuous glucose monitoring and closed-loop systems
    • Hovorka R.: Continuous glucose monitoring and closed-loop systems. Diabet Med. 2006;23:1-12.
    • (2006) Diabet Med. , vol.23 , pp. 1-12
    • Hovorka, R.1
  • 88
    • 33645700078 scopus 로고    scopus 로고
    • Computer-aided continuous drug infusion: Setup and test of a mobile closed-loop system for the continuous automated infusion of insulin
    • Dudde R, Vering T, Piechotta G, Hintsche R. Computer-aided continuous drug infusion: setup and test of a mobile closed-loop system for the continuous automated infusion of insulin. IEEE Trans Inf Technol Biomed. 2006;10:395-402.
    • (2006) IEEE Trans Inf Technol Biomed. , vol.10 , pp. 395-402
    • Dudde, R.1    Vering, T.2    Piechotta, G.3    Hintsche, R.4
  • 90
    • 33845536563 scopus 로고    scopus 로고
    • Automated feedback-controlled insulin delivery in children with tytpe 1 diabetes mellitus (T1D): A preliminary report
    • Weinzimer SA, Steil GM, Kurtz N, Swan KL, Tamborlane WV: Automated feedback-controlled insulin delivery in children with tytpe 1 diabetes mellitus (T1D): a preliminary report. Diabetes. 2006;55:431-P.
    • (2006) Diabetes. , vol.55
    • Weinzimer, S.A.1    Steil, G.M.2    Kurtz, N.3    Swan, K.L.4    Tamborlane, W.V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.