메뉴 건너뛰기




Volumn 10, Issue 2, 2006, Pages 395-402

Computer-aided continuous drug infusion: Setup and test of a mobile closed-loop system for the continuous automated infusion of insulin

Author keywords

Diabetes; Glucose monitor; Insulin infusion

Indexed keywords

ALGORITHMS; CLOSED LOOP CONTROL SYSTEMS; DRUG INFUSION; DRUG PRODUCTS; INSULIN;

EID: 33645700078     PISSN: 10897771     EISSN: None     Source Type: Journal    
DOI: 10.1109/TITB.2006.864477     Document Type: Article
Times cited : (42)

References (18)
  • 2
    • 0034018346 scopus 로고    scopus 로고
    • "The promise of technology in the management of the patient with diabetes"
    • E. Colloff, "The promise of technology in the management of the patient with diabetes," Diabetes Technol. Ther., vol. 2, no. 1, pp. 91-99, 2000.
    • (2000) Diabetes Technol. Ther. , vol.2 , Issue.1 , pp. 91-99
    • Colloff, E.1
  • 3
    • 33645702129 scopus 로고    scopus 로고
    • "Welcome to diabetes technology & therapeutics"
    • D. C. Klonoff, "Welcome to diabetes technology & therapeutics," Diabetes Technol. Ther., vol. 1, no. 1, pp. 1-2, 1999.
    • (1999) Diabetes Technol. Ther. , vol.1 , Issue.1 , pp. 1-2
    • Klonoff, D.C.1
  • 6
    • 0031914389 scopus 로고    scopus 로고
    • "Enhanced, simplified glucose sensor: Long-term clinical application of wearable artificial endocrine pancreas"
    • M. Shichiri, M. Sakakida, K. Nishida, and S. Shimoda, "Enhanced, simplified glucose sensor: Long-term clinical application of wearable artificial endocrine pancreas," Artif. Organs, vol. 22, pp. 32-42, 1998.
    • (1998) Artif. Organs , vol.22 , pp. 32-42
    • Shichiri, M.1    Sakakida, M.2    Nishida, K.3    Shimoda, S.4
  • 7
    • 0033431643 scopus 로고    scopus 로고
    • "The MiniMed continuous glucose monitoring system"
    • J. Mastrototar, "The MiniMed continuous glucose monitoring system," J. Pediatr. Endocrinol. Metab., vol. 12, pp. 751-758, 1999.
    • (1999) J. Pediatr. Endocrinol. Metab. , vol.12 , pp. 751-758
    • Mastrototar, J.1
  • 8
    • 0034780892 scopus 로고    scopus 로고
    • "Clinical evaluation of the GlucoWatch Biographer: A continual, non-invasive glucose monitor for patients with diabetes"
    • M. J. Tierney, J. A. Tamada, R. O. Potts, L. Jovanovic, and S. Garg, "Clinical evaluation of the GlucoWatch Biographer: A continual, non-invasive glucose monitor for patients with diabetes," Biosens. Bioelectron., vol. 16, pp. 621-629, 2001.
    • (2001) Biosens. Bioelectron. , vol.16 , pp. 621-629
    • Tierney, M.J.1    Tamada, J.A.2    Potts, R.O.3    Jovanovic, L.4    Garg, S.5
  • 9
    • 0030175963 scopus 로고    scopus 로고
    • "Glucose monitoring: State of the art"
    • E. Wilkens and P. Atanasov, "Glucose monitoring: State of the art," Med. Eng. Phys., vol. 18, pp. 273-288, 1996.
    • (1996) Med. Eng. Phys. , vol.18 , pp. 273-288
    • Wilkens, E.1    Atanasov, P.2
  • 11
    • 1842338688 scopus 로고    scopus 로고
    • "Open-flow microperfusion of subcutaneous adipose tissue for on-line continuous ex vivo measurement of glucose concentration"
    • Z. Trajanoski, G. A. Brunner, L. Schaupp, M. Ellmerer, P. Wach, T. R. Pieber, P. Kotanko, and F. Skrabal, "Open-flow microperfusion of subcutaneous adipose tissue for on-line continuous ex vivo measurement of glucose concentration," Diabetes Care, vol. 20, pp. 1114-1121, 1997.
    • (1997) Diabetes Care , vol.20 , pp. 1114-1121
    • Trajanoski, Z.1    Brunner, G.A.2    Schaupp, L.3    Ellmerer, M.4    Wach, P.5    Pieber, T.R.6    Kotanko, P.7    Skrabal, F.8
  • 14
    • 33645703113 scopus 로고    scopus 로고
    • "Vergleich zwischen S. C. Sensoren und der offenen Mikroperfusionstechnik zur kontinuierlichen Messung der Glukosekonzentration bei Typ 1 Diabetikem"
    • L. Schaupp, H. Schaller, M. Bodenlenz, B. Balent, J. Plank, R. Sommer, P. Wach, and T. R. Pieber, "Vergleich zwischen S. C. Sensoren und der offenen Mikroperfusionstechnik zur kontinuierlichen Messung der Glukosekonzentration bei Typ 1 Diabetikem," Acta Med. Austriaca Suppl., vol. 55, p. 19, 2001.
    • (2001) Acta Med. Austriaca Suppl. , vol.55 , pp. 19
    • Schaupp, L.1    Schaller, H.2    Bodenlenz, M.3    Balent, B.4    Plank, J.5    Sommer, R.6    Wach, P.7    Pieber, T.R.8
  • 15
    • 26944446945 scopus 로고    scopus 로고
    • "Novel micromachined silicon sensor for continuous glucose monitoring"
    • G. Piechotta, J. Albers, and R. Hintsche, "Novel micromachined silicon sensor for continuous glucose monitoring," Biosens. Bioelectron., vol. 21, pp. 802-808, 2005.
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 802-808
    • Piechotta, G.1    Albers, J.2    Hintsche, R.3
  • 16
    • 0035156628 scopus 로고    scopus 로고
    • "The subcutaneous route to insulin-dependent diabetes therapy"
    • Jan./Feb
    • R. Bellazi, G. Nucci, and C. Cobelli, "The subcutaneous route to insulin-dependent diabetes therapy," IEEE Eng. Med. Biol. Mag., vol. 20, no. 1, pp. 54-64, Jan./Feb. 2001.
    • (2001) IEEE Eng. Med. Biol. Mag. , vol.20 , Issue.1 , pp. 54-64
    • Bellazi, R.1    Nucci, G.2    Cobelli, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.