Volumn 3, Issue 1, 2007, Pages 19-26

Gadofosveset: The first intravascular contrast agent EU-approved for use with magnetic resonance angiography

Author keywords

Gadofosveset; Magnetic resonance angiography; Magnetic resonance contrast agent; Magnetic resonance imaging; Vasovist

Indexed keywords

ALBUMIN; DIAZEPAM; DICLOFENAC; DIGITOXIN; GADOFOSVESET; GADOLINIUM CHELATE; IBUPROFEN; KETOPROFEN; NAPROXEN; NUCLEAR MAGNETIC RESONANCE IMAGING AGENT; PHENPROCOUMON; PIROXICAM; PLACEBO; PROPRANOLOL; VERAPAMIL; WARFARIN;

EID: 33846482508     PISSN: 14796678     EISSN: 17448298     Source Type: Journal    
DOI: 10.2217/14796678.3.1.19     Document Type: Article
Times cited : (4)

References (16)
  • 1
    • 0021962018 scopus 로고
    • The prevalence of peripheral arterial disease in a defined population
    • Criqui MH, Fronek A, Barrett-Connor E et al.: The prevalence of peripheral arterial disease in a defined population. Circulation 71, 510-515 (1985).
    • (1985) Circulation , vol.71 , pp. 510-515
    • Criqui, M.H.1    Fronek, A.2    Barrett-Connor, E.3
  • 2
    • 0026659372 scopus 로고
    • Lower extremity artenal disease and the aging process: A review
    • Vogt MT, Wolfson SK, Kuller LH et al.: Lower extremity artenal disease and the aging process: a review. J. Clin. Epidemiol. 45, 529-542 (1992).
    • (1992) J. Clin. Epidemiol. , vol.45 , pp. 529-542
    • Vogt, M.T.1    Wolfson, S.K.2    Kuller, L.H.3
  • 3
    • 1842333893 scopus 로고    scopus 로고
    • CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease
    • Rieker O, Duber C, Neufang A et al.: CT angiography versus intraarterial digital subtraction angiography for assessment of aortoiliac occlusive disease. Am. J. Rheum. 169, 1133-1138 (1997).
    • (1997) Am. J. Rheum. , vol.169 , pp. 1133-1138
    • Rieker, O.1    Duber, C.2    Neufang, A.3
  • 4
    • 0036665158 scopus 로고    scopus 로고
    • Magnetic resonance angiography for the diagnosis of renal artery stanosis: A mete-analysis
    • Tan KT, van Beek EJ, Brown PW et al.: Magnetic resonance angiography for the diagnosis of renal artery stanosis: a mete-analysis. Clin. Radiol. 57, 617-624 (2002).
    • (2002) Clin. Radiol. , vol.57 , pp. 617-624
    • Tan, K.T.1    van Beek, E.J.2    Brown, P.W.3
  • 5
    • 0033980469 scopus 로고    scopus 로고
    • MRA of the abdominal aorta and lower extremities
    • Grist T: MRA of the abdominal aorta and lower extremities. J. Magn. Reson. Imaging 11, 32-43 (2000).
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 32-43
    • Grist, T.1
  • 6
    • 20744455805 scopus 로고    scopus 로고
    • Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: Safety and efficacy of gadofosveset-enhancad MR angiography - Multicenter comparative Phase III study
    • Rapp JH, Wolff SD, Quinn SF et al.: Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhancad MR angiography - multicenter comparative Phase III study. Radiology 236, 71-78 (2005).
    • (2005) Radiology , vol.236 , pp. 71-78
    • Rapp, J.H.1    Wolff, S.D.2    Quinn, S.F.3
  • 7
    • 23844477876 scopus 로고    scopus 로고
    • MR angiography of aortoiliac occlusive disease: A Phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325
    • Goyen M, Edelman M, Perreault P et al.: MR angiography of aortoiliac occlusive disease: a Phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325. Radiology 236, 825-833 (2005).
    • (2005) Radiology , vol.236 , pp. 825-833
    • Goyen, M.1    Edelman, M.2    Perreault, P.3
  • 8
    • 7244247159 scopus 로고    scopus 로고
    • Accuracy of computed monographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis
    • Vasbinder GB, Nelemans PJ, Kessels AG et al.: Accuracy of computed monographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann. Intern. Med. 141, 674-682 (2004).
    • (2004) Ann. Intern. Med. , vol.141 , pp. 674-682
    • Vasbinder, G.B.1    Nelemans, P.J.2    Kessels, A.G.3
  • 9
    • 17644381276 scopus 로고    scopus 로고
    • High-spatial-resolution MR-angiography of renal arteries wirh integrated parallel acquisitions: Comparison with digital subtraction angiography and US
    • Schoenberg SO, Rieger JR, Weber CH et al.: High-spatial-resolution MR-angiography of renal arteries wirh integrated parallel acquisitions: comparison with digital subtraction angiography and US. Radiology 236, 687-698 (2005).
    • (2005) Radiology , vol.236 , pp. 687-698
    • Schoenberg, S.O.1    Rieger, J.R.2    Weber, C.H.3
  • 10
    • 0032967860 scopus 로고    scopus 로고
    • Renal arteries: Optimization of three-dimensional gadolinium-enhancedMR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold
    • Schoenberg SO, Bock M, Knopp MV et al.: Renal arteries: optimization of three-dimensional gadolinium-enhancedMR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold, Radiology 211, 667-679 (1999).
    • (1999) Radiology , vol.211 , pp. 667-679
    • Schoenberg, S.O.1    Bock, M.2    Knopp, M.V.3
  • 11
    • 15944429689 scopus 로고    scopus 로고
    • Critical limb ischemia: Hybrid-MR angiography compared with DSA
    • Meissner OA, Rieger J, Weber C et al.: Critical limb ischemia: hybrid-MR angiography compared with DSA. Radiology 235, 308-318 (2005).
    • (2005) Radiology , vol.235 , pp. 308-318
    • Meissner, O.A.1    Rieger, J.2    Weber, C.3
  • 12
    • 33846470999 scopus 로고    scopus 로고
    • High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: Initial experience
    • Nikolaou K, Kramer H, Grosse C et al.: High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: initial expericnce. Radiology 241, 861-872 (2006).
    • (2006) Radiology , vol.241 , pp. 861-872
    • Nikolaou, K.1    Kramer, H.2    Grosse, C.3
  • 13
    • 1342329969 scopus 로고    scopus 로고
    • Peripheral vasculature: Whole-body MR angiography with midfemoral venous compression - Initial experience
    • Herborn CU, Ajaj W, Goyen M et al.: Peripheral vasculature: whole-body MR angiography with midfemoral venous compression - initial experience. Rediology 230, 872-878 (2004).
    • (2004) Radiology , vol.230 , pp. 872-878
    • Herborn, C.U.1    Ajaj, W.2    Goyen, M.3
  • 14
    • 20744437425 scopus 로고    scopus 로고
    • Cardiovascular screening with parallel imaging techniques and a whole-body MR imager
    • Kramer H, Schoenberg SO, Nikolaou K et al.: Cardiovascular screening with parallel imaging techniques and a whole-body MR imager. Radiology 236, 300-310 (2005).
    • (2005) Radiology , vol.236 , pp. 300-310
    • Kramer, H.1    Schoenberg, S.O.2    Nikolaou, K.3
  • 15
    • 0034111614 scopus 로고    scopus 로고
    • Pelvic and lower extremity veins: Contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience
    • Ruehm SG, Wiesner W, Debatin JF: Pelvic and lower extremity veins: contrast-enhanced three-dimensional MR venography with a dedicated vascular coil-initial experience. Radiology 215, 421-427 (2000).
    • (2000) Radiology , vol.215 , pp. 421-427
    • Ruehm, S.G.1    Wiesner, W.2    Debatin, J.F.3
  • 16
    • 0037062132 scopus 로고    scopus 로고
    • Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: A prospective study
    • Oudkerk M, van Beek EJ, Wielopolski P et al.: Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study. Lancet 359, 1643-1647 (2002).
    • (2002) Lancet , vol.359 , pp. 1643-1647
    • Oudkerk, M.1    van Beek, E.J.2    Wielopolski, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.