메뉴 건너뛰기




Volumn 241, Issue 3, 2006, Pages 861-872

High-spatial-resolution multistation MR angiography with parallel imaging and blood pool contrast agent: Initial experience

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM; GADOFOSVESET;

EID: 33846470999     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2413060053     Document Type: Article
Times cited : (100)

References (18)
  • 1
    • 4644226383 scopus 로고    scopus 로고
    • Imaging of carotid arteries in symptomatic patients: Cost-effectiveness of diagnostic strategies
    • Buskens E, Nederkoorn PJ, Buijs-Van Der Woude T, et al. Imaging of carotid arteries in symptomatic patients: cost-effectiveness of diagnostic strategies. Radiology 2004;233:101-112.
    • (2004) Radiology , vol.233 , pp. 101-112
    • Buskens, E.1    Nederkoorn, P.J.2    Buijs-Van Der Woude, T.3
  • 2
    • 17644381276 scopus 로고    scopus 로고
    • High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: Comparison with digital subtraction angiography and US
    • Schoenberg SO, Rieger J, Weber CH, et al. High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: comparison with digital subtraction angiography and US. Radiology 2005;235:687-698.
    • (2005) Radiology , vol.235 , pp. 687-698
    • Schoenberg, S.O.1    Rieger, J.2    Weber, C.H.3
  • 3
    • 15944429689 scopus 로고    scopus 로고
    • Critical limb ischemia: Hybrid MR angiography compared with DSA
    • Meissner OA, Rieger J, Weber C, et al. Critical limb ischemia: hybrid MR angiography compared with DSA. Radiology 2005;235:308-318.
    • (2005) Radiology , vol.235 , pp. 308-318
    • Meissner, O.A.1    Rieger, J.2    Weber, C.3
  • 4
    • 0035820272 scopus 로고    scopus 로고
    • Rapid magnetic resonance angiography for detection of atherosclerosis
    • Ruehm SG, Goyen M, Barkhausen J, et al. Rapid magnetic resonance angiography for detection of atherosclerosis. Lancet 2001;357:1086-1091.
    • (2001) Lancet , vol.357 , pp. 1086-1091
    • Ruehm, S.G.1    Goyen, M.2    Barkhausen, J.3
  • 5
    • 2442693136 scopus 로고    scopus 로고
    • Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease
    • Herborn CU, Goyen M, Quick HH, et al. Whole-body 3D MR angiography of patients with peripheral arterial occlusive disease. AJR Am J Roentgenol 2004;182:1427-1434.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 1427-1434
    • Herborn, C.U.1    Goyen, M.2    Quick, H.H.3
  • 6
    • 0034242336 scopus 로고    scopus 로고
    • Whole-body MR angiography on a rolling table platform (AngioSURF) [in German]
    • Ruehm SG, Goyen M, Quick HH, et al. Whole-body MR angiography on a rolling table platform (AngioSURF) [in German]. Rofo 2000;172:670-674.
    • (2000) Rofo , vol.172 , pp. 670-674
    • Ruehm, S.G.1    Goyen, M.2    Quick, H.H.3
  • 7
    • 20744437425 scopus 로고    scopus 로고
    • Cardiovascular screening with parallel imaging techniques and a whole-body MR imager
    • Kramer H, Schoenberg SO, Nikolaou K, et al. Cardiovascular screening with parallel imaging techniques and a whole-body MR imager. Radiology 2005;236:300-310,
    • (2005) Radiology , vol.236 , pp. 300-310
    • Kramer, H.1    Schoenberg, S.O.2    Nikolaou, K.3
  • 8
    • 14844324342 scopus 로고    scopus 로고
    • Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries
    • Vogt FM, Ajaj W, Hunold P, et al. Venous compression at high-spatial-resolution three-dimensional MR angiography of peripheral arteries. Radiology 2004;233:913-920.
    • (2004) Radiology , vol.233 , pp. 913-920
    • Vogt, F.M.1    Ajaj, W.2    Hunold, P.3
  • 9
    • 16544382389 scopus 로고    scopus 로고
    • Cuff-compression of the proximal calf to reduce venous contamination in contrast-enhanced stepping-table magnetic resonance angiography
    • Bilecen D, Jager KA, Aschwanden M, Heidecker HG, Schulte AC, Bongartz G. Cuff-compression of the proximal calf to reduce venous contamination in contrast-enhanced stepping-table magnetic resonance angiography. Acta Radiol 2004;45:510-515.
    • (2004) Acta Radiol , vol.45 , pp. 510-515
    • Bilecen, D.1    Jager, K.A.2    Aschwanden, M.3    Heidecker, H.G.4    Schulte, A.C.5    Bongartz, G.6
  • 11
    • 7244247159 scopus 로고    scopus 로고
    • Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis
    • Vasbinder GB, Nelemans PJ, Kessels AG, et al. Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis. Ann Intern Med 2004;141:674-682.
    • (2004) Ann Intern Med , vol.141 , pp. 674-682
    • Vasbinder, G.B.1    Nelemans, P.J.2    Kessels, A.G.3
  • 12
    • 0344584515 scopus 로고    scopus 로고
    • MR angiography with gadofosveset trisodium for peripheral vascular disease: Phase II trial
    • Perreault P, Edelman MA, Baum RA, et al. MR angiography with gadofosveset trisodium for peripheral vascular disease: phase II trial. Radiology 2003;229:811-820.
    • (2003) Radiology , vol.229 , pp. 811-820
    • Perreault, P.1    Edelman, M.A.2    Baum, R.A.3
  • 13
    • 0031836465 scopus 로고    scopus 로고
    • MS-325: Albumin-targeted contrast agent for MR angiography
    • Lauffer RB, Parmelee DJ, Dunham SU, et al. MS-325: albumin-targeted contrast agent for MR angiography. Radiology 1998;207:529-538.
    • (1998) Radiology , vol.207 , pp. 529-538
    • Lauffer, R.B.1    Parmelee, D.J.2    Dunham, S.U.3
  • 14
    • 27544442176 scopus 로고    scopus 로고
    • Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths
    • Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ. Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 2005;40:715-724.
    • (2005) Invest Radiol , vol.40 , pp. 715-724
    • Rohrer, M.1    Bauer, H.2    Mintorovitch, J.3    Requardt, M.4    Weinmann, H.J.5
  • 15
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 16
    • 0036234895 scopus 로고    scopus 로고
    • 3D MR angiography of renal arteries: Comparison of volume rendering and maximum intensity projection algorithms
    • Mallouhi A, Schocke M, Judmaier W, et al. 3D MR angiography of renal arteries: comparison of volume rendering and maximum intensity projection algorithms. Radiology 2002;223:509-516.
    • (2002) Radiology , vol.223 , pp. 509-516
    • Mallouhi, A.1    Schocke, M.2    Judmaier, W.3
  • 17
    • 23844477876 scopus 로고    scopus 로고
    • MR angiography of aortoiliac occlusive disease: A phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325
    • Goyen M, Edelman M, Perreault P, et al. MR angiography of aortoiliac occlusive disease: a phase III study of the safety and effectiveness of the blood-pool contrast agent MS-325. Radiology 2005;236:825-833.
    • (2005) Radiology , vol.236 , pp. 825-833
    • Goyen, M.1    Edelman, M.2    Perreault, P.3
  • 18
    • 20744455805 scopus 로고    scopus 로고
    • Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: Safety and efficacy of gadofosveset-enhanced MR angiography-multicenter comparative phase III study
    • Rapp JH, Wolff SD, Quinn SF, et al. Aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease: safety and efficacy of gadofosveset-enhanced MR angiography-multicenter comparative phase III study. Radiology 2005;236:71-78.
    • (2005) Radiology , vol.236 , pp. 71-78
    • Rapp, J.H.1    Wolff, S.D.2    Quinn, S.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.