메뉴 건너뛰기




Volumn 33, Issue 1, 2007, Pages 21-30

Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ALGORITHM; ARTICLE; ATLAS TOPOGRAPHY; CLINICAL ARTICLE; CONTACT LENS; CORNEA; CORNEA CURVATURE; EXCIMER LASER; FEMALE; HOLLADAY 2 FORMULA; HUMAN; INTERMETHOD COMPARISON; KERATOMETRY; LENS IMPLANT; LENS POWER; MALE; MATHEMATICAL MODEL; MYOPIA; PHACOEMULSIFICATION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REFRACTION INDEX; REFRACTIVE SURGERY; UNITED STATES; VIDEOKERATOGRAPHY;

EID: 33845738187     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2006.08.026     Document Type: Article
Times cited : (59)

References (44)
  • 1
    • 0042205452 scopus 로고    scopus 로고
    • Intraocular lens calculations in patients with corneal scarring and irregular astigmatism
    • Cua I.Y., Qazi M.A., Lee S.F., and Pepose J.S. Intraocular lens calculations in patients with corneal scarring and irregular astigmatism. J Cataract Refract Surg 29 (2003) 1352-1357
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1352-1357
    • Cua, I.Y.1    Qazi, M.A.2    Lee, S.F.3    Pepose, J.S.4
  • 2
    • 0027179635 scopus 로고
    • Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculations
    • Cuaycong M.J., Gay C.A., Emery J., et al. Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculations. J Cataract Refract Surg 19 (1993) 178-181
    • (1993) J Cataract Refract Surg , vol.19 , pp. 178-181
    • Cuaycong, M.J.1    Gay, C.A.2    Emery, J.3
  • 3
    • 0028820164 scopus 로고
    • Intraocular lens power calculation for eyes after refractive keratotomy
    • Hoffer K.J. Intraocular lens power calculation for eyes after refractive keratotomy. J Refract Surg 11 (1995) 490-493
    • (1995) J Refract Surg , vol.11 , pp. 490-493
    • Hoffer, K.J.1
  • 4
    • 0033498941 scopus 로고    scopus 로고
    • Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy
    • Seitz B., Langenbucher A., Nguyen N.X., et al. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy. Ophthalmology 106 (1999) 693-702
    • (1999) Ophthalmology , vol.106 , pp. 693-702
    • Seitz, B.1    Langenbucher, A.2    Nguyen, N.X.3
  • 5
    • 0033966206 scopus 로고    scopus 로고
    • Intraocular lens calculations status after corneal refractive surgery
    • Seitz B., and Langenbucher A. Intraocular lens calculations status after corneal refractive surgery. Curr Opin Ophthalmol 11 (2000) 35-46
    • (2000) Curr Opin Ophthalmol , vol.11 , pp. 35-46
    • Seitz, B.1    Langenbucher, A.2
  • 6
    • 0034076365 scopus 로고    scopus 로고
    • Intraocular lens power calculation in eyes after corneal refractive surgery
    • Seitz B., and Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg 16 (2000) 349-361
    • (2000) J Refract Surg , vol.16 , pp. 349-361
    • Seitz, B.1    Langenbucher, A.2
  • 7
    • 0035320552 scopus 로고    scopus 로고
    • Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis
    • Gimbel H.V., and Sun R. Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis. J Cataract Refract Surg 27 (2001) 571-576
    • (2001) J Cataract Refract Surg , vol.27 , pp. 571-576
    • Gimbel, H.V.1    Sun, R.2
  • 8
    • 0035147564 scopus 로고    scopus 로고
    • Intra-ocular lens calculation status after corneal refractive surgery
    • Speicher L. Intra-ocular lens calculation status after corneal refractive surgery. Curr Opin Ophthalmol 12 (2001) 17-29
    • (2001) Curr Opin Ophthalmol , vol.12 , pp. 17-29
    • Speicher, L.1
  • 9
    • 0037323783 scopus 로고    scopus 로고
    • Cataract surgery in patients with prior refractive surgery
    • Hamilton D.R., and Hardten D.R. Cataract surgery in patients with prior refractive surgery. Curr Opin Ophthalmol 14 (2003) 44-53
    • (2003) Curr Opin Ophthalmol , vol.14 , pp. 44-53
    • Hamilton, D.R.1    Hardten, D.R.2
  • 10
    • 0042706567 scopus 로고    scopus 로고
    • Intraocular lens power calculation after refractive surgery
    • Argento C., Cosentino M.J., and Badoza D. Intraocular lens power calculation after refractive surgery. J Cataract Refract Surg 29 (2003) 1346-1351
    • (2003) J Cataract Refract Surg , vol.29 , pp. 1346-1351
    • Argento, C.1    Cosentino, M.J.2    Badoza, D.3
  • 11
    • 3242713890 scopus 로고    scopus 로고
    • Intraocular lens power calculation after corneal refractive surgery
    • Feiz V., and Mannis M.J. Intraocular lens power calculation after corneal refractive surgery. Curr Opin Ophthalmol 15 (2004) 342-349
    • (2004) Curr Opin Ophthalmol , vol.15 , pp. 342-349
    • Feiz, V.1    Mannis, M.J.2
  • 12
    • 20444457969 scopus 로고    scopus 로고
    • Vergleichende Ergebnisse der Hornhautbrechkraftbestimmung dreier Messgeräte nach LASIK
    • Schäfer S., Kürzinger G., Spraul C.W., and Kampmeier J. Vergleichende Ergebnisse der Hornhautbrechkraftbestimmung dreier Messgeräte nach LASIK. Klin Monatsbl Augenheilkd 222 (2005) 419-423
    • (2005) Klin Monatsbl Augenheilkd , vol.222 , pp. 419-423
    • Schäfer, S.1    Kürzinger, G.2    Spraul, C.W.3    Kampmeier, J.4
  • 14
    • 0842305653 scopus 로고    scopus 로고
    • A direct method to measure the power of the central cornea after myopic in situ keratomileusis
    • Sónego-Krone S., López-Moreno G., Beaujon-Balbi O.V., et al. A direct method to measure the power of the central cornea after myopic in situ keratomileusis. Arch Ophthalmol 122 (2004) 159-166
    • (2004) Arch Ophthalmol , vol.122 , pp. 159-166
    • Sónego-Krone, S.1    López-Moreno, G.2    Beaujon-Balbi, O.V.3
  • 15
    • 13844313472 scopus 로고    scopus 로고
    • Response of the posterior corneal surface to laser in situ keratomileusis for myopia
    • Twa M.D., Roberts C., Mahmoud A.M., and Chang J.S. Response of the posterior corneal surface to laser in situ keratomileusis for myopia. J Cataract Refract Surg 31 (2005) 61-71
    • (2005) J Cataract Refract Surg , vol.31 , pp. 61-71
    • Twa, M.D.1    Roberts, C.2    Mahmoud, A.M.3    Chang, J.S.4
  • 16
    • 0036205558 scopus 로고    scopus 로고
    • A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis
    • Hamed A.M., Wang L., Misra M., and Koch D.D. A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis. Ophthalmology 109 (2002) 651-658
    • (2002) Ophthalmology , vol.109 , pp. 651-658
    • Hamed, A.M.1    Wang, L.2    Misra, M.3    Koch, D.D.4
  • 17
    • 0036854822 scopus 로고    scopus 로고
    • Measuring corneal power for intraocular lens power calculation after refractive surgery; comparison of methods
    • Kim J.-H., Lee D.-H., and Joo C.-K. Measuring corneal power for intraocular lens power calculation after refractive surgery; comparison of methods. J Cataract Refract Surg 28 (2002) 1932-1938
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1932-1938
    • Kim, J.-H.1    Lee, D.-H.2    Joo, C.-K.3
  • 18
    • 4744341208 scopus 로고    scopus 로고
    • Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK
    • Wang L., Booth M.A., and Koch D.D. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology 111 (2004) 1825-1831
    • (2004) Ophthalmology , vol.111 , pp. 1825-1831
    • Wang, L.1    Booth, M.A.2    Koch, D.D.3
  • 20
    • 0032992877 scopus 로고    scopus 로고
    • Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity
    • Zeh W.G., and Koch D.D. Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity. J Cataract Refract Surg 25 (1999) 898-903
    • (1999) J Cataract Refract Surg , vol.25 , pp. 898-903
    • Zeh, W.G.1    Koch, D.D.2
  • 21
    • 0028875511 scopus 로고
    • Calculation of intraocular lens power after radial keratotomy with computerized videokeratography
    • Celikkol L., Pavlopoulos G., Weinstein B., et al. Calculation of intraocular lens power after radial keratotomy with computerized videokeratography. Am J Ophthalmol 120 (1995) 739-750
    • (1995) Am J Ophthalmol , vol.120 , pp. 739-750
    • Celikkol, L.1    Pavlopoulos, G.2    Weinstein, B.3
  • 22
    • 0029936409 scopus 로고    scopus 로고
    • Computerized videokeratography and keratometry in determining intraocular lens calculations
    • Husain S.E., Kohnen T., Maturi R., et al. Computerized videokeratography and keratometry in determining intraocular lens calculations. J Cataract Refract Surg 22 (1996) 362-366
    • (1996) J Cataract Refract Surg , vol.22 , pp. 362-366
    • Husain, S.E.1    Kohnen, T.2    Maturi, R.3
  • 23
    • 0033485849 scopus 로고    scopus 로고
    • Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis
    • Srivannaboon S., Reinstein D.Z., Sutton H.F.S., and Holland S.P. Accuracy of Orbscan total optical power maps in detecting refractive change after myopic laser in situ keratomileusis. J Cataract Refract Surg 25 (1999) 1596-1599
    • (1999) J Cataract Refract Surg , vol.25 , pp. 1596-1599
    • Srivannaboon, S.1    Reinstein, D.Z.2    Sutton, H.F.S.3    Holland, S.P.4
  • 24
    • 0034907377 scopus 로고    scopus 로고
    • Intraocular lens power calculations using corneal topography after photorefractive keratectomy
    • Ladas J.G., Boxer Wachler B.S., Hunkeler J.D., and Durrie D.S. Intraocular lens power calculations using corneal topography after photorefractive keratectomy. Am J Ophthalmol 132 (2001) 254-255
    • (2001) Am J Ophthalmol , vol.132 , pp. 254-255
    • Ladas, J.G.1    Boxer Wachler, B.S.2    Hunkeler, J.D.3    Durrie, D.S.4
  • 25
    • 3042695528 scopus 로고    scopus 로고
    • Intraocular lens power calculation after incisional and thermal keratorefractive surgery
    • Packer M., Brown L.K., Hoffman R.S., and Fine I.H. Intraocular lens power calculation after incisional and thermal keratorefractive surgery. J Cataract Refract Surg 30 (2004) 1430-1434
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1430-1434
    • Packer, M.1    Brown, L.K.2    Hoffman, R.S.3    Fine, I.H.4
  • 26
    • 22644442254 scopus 로고    scopus 로고
    • Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis
    • Cheng A.C.K., and Lam D.S.C. Keratometry for intraocular lens power calculation using Orbscan II in eyes with laser in situ keratomileusis. J Refract Surg 21 (2005) 365-368
    • (2005) J Refract Surg , vol.21 , pp. 365-368
    • Cheng, A.C.K.1    Lam, D.S.C.2
  • 27
    • 0031984513 scopus 로고    scopus 로고
    • The prediction of surgically induced refractive change from corneal topography
    • Smith R.J., Chan W.-K., and Maloney R.K. The prediction of surgically induced refractive change from corneal topography. Am J Ophthalmol 125 (1998) 44-53
    • (1998) Am J Ophthalmol , vol.125 , pp. 44-53
    • Smith, R.J.1    Chan, W.-K.2    Maloney, R.K.3
  • 28
    • 0023858680 scopus 로고    scopus 로고
    • Comparison of the SRK II™ formula and other second generation formulas
    • Sanders D.R., Retzlaff J., and Kraff M.C. Comparison of the SRK II™ formula and other second generation formulas. J Cataract Refract Surg 14 (1998) 136-141
    • (1998) J Cataract Refract Surg , vol.14 , pp. 136-141
    • Sanders, D.R.1    Retzlaff, J.2    Kraff, M.C.3
  • 29
    • 0034764626 scopus 로고    scopus 로고
    • Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia; a standardized approach
    • Feiz V., Mannis M.J., Garcia-Ferrer F., et al. Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia; a standardized approach. Cornea 20 (2001) 792-797
    • (2001) Cornea , vol.20 , pp. 792-797
    • Feiz, V.1    Mannis, M.J.2    Garcia-Ferrer, F.3
  • 30
    • 0027943021 scopus 로고
    • The accuracy of "power" maps to display curvature data in corneal topography systems
    • Roberts C. The accuracy of "power" maps to display curvature data in corneal topography systems. Invest Ophthalmol Vis Sci 35 (1994) 3525-3532
    • (1994) Invest Ophthalmol Vis Sci , vol.35 , pp. 3525-3532
    • Roberts, C.1
  • 31
    • 33845730153 scopus 로고    scopus 로고
    • Corneal topography: basic principles
    • Azar D.T., Gatinel D., and Hoand-Xuan II T. (Eds), Mosby, St Louis, MO In Press
    • Roberts C. Corneal topography: basic principles. In: Azar D.T., Gatinel D., and Hoand-Xuan II T. (Eds). Refractive Surgery. 2nd ed. (2006), Mosby, St Louis, MO In Press
    • (2006) Refractive Surgery. 2nd ed.
    • Roberts, C.1
  • 32
    • 0035161383 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes
    • Chakrabarti H.S., Craig J.P., Brahma A., et al. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes. J Cataract Refract Surg 27 (2001) 1823-1828
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1823-1828
    • Chakrabarti, H.S.1    Craig, J.P.2    Brahma, A.3
  • 33
    • 0037373268 scopus 로고    scopus 로고
    • Reliability of pachymetric measurements using Orbscan after excimer refractive surgery
    • Prisant O., Calderon N., Chastang P., et al. Reliability of pachymetric measurements using Orbscan after excimer refractive surgery. Ophthalmology 110 (2003) 511-515
    • (2003) Ophthalmology , vol.110 , pp. 511-515
    • Prisant, O.1    Calderon, N.2    Chastang, P.3
  • 34
    • 0036303315 scopus 로고    scopus 로고
    • Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia
    • Odenthal M.T.P., Eggink C.A., Melles G., et al. Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia. Arch Ophthalmol 120 (2002) 421-438
    • (2002) Arch Ophthalmol , vol.120 , pp. 421-438
    • Odenthal, M.T.P.1    Eggink, C.A.2    Melles, G.3
  • 35
    • 0036594922 scopus 로고    scopus 로고
    • Comparison of IOL powers by corrected method in eyes after PRK and LASIK
    • Koo O.S., Kim J.-G., and Song B.J. Comparison of IOL powers by corrected method in eyes after PRK and LASIK. Korean J Ophthalmol 16 (2002) 26-31
    • (2002) Korean J Ophthalmol , vol.16 , pp. 26-31
    • Koo, O.S.1    Kim, J.-G.2    Song, B.J.3
  • 36
    • 0346119007 scopus 로고    scopus 로고
    • Calculating IOL power in eyes that have had refractive surgery
    • [editorial]
    • Koch D.D., and Wang L. Calculating IOL power in eyes that have had refractive surgery. [editorial]. J Cataract Refract Surg 29 (2003) 2039-2042
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2039-2042
    • Koch, D.D.1    Wang, L.2
  • 37
    • 0347379977 scopus 로고    scopus 로고
    • Intraocular lens power calculation after corneal refractive surgery: double-K method
    • Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg 29 (2003) 2063-2068
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2063-2068
    • Aramberri, J.1
  • 38
    • 23944465227 scopus 로고    scopus 로고
    • Intraoperative optical refractive biometry for intraocular lens power estimation without axial length and keratometry measurements
    • Ianchulev T., Salz J., Hoffer K., et al. Intraoperative optical refractive biometry for intraocular lens power estimation without axial length and keratometry measurements. J Cataract Refract Surg 31 (2005) 1530-1536
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1530-1536
    • Ianchulev, T.1    Salz, J.2    Hoffer, K.3
  • 39
    • 20544442305 scopus 로고    scopus 로고
    • Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery
    • Rosa N., Capasso L., Lanza M., et al. Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery. J Cataract Refract Surg 31 (2005) 1020-1024
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1020-1024
    • Rosa, N.1    Capasso, L.2    Lanza, M.3
  • 40
    • 23044446383 scopus 로고    scopus 로고
    • Nomogram-based intraocular lens power adjustment after myopic photorefractive keratectomy and LASIK; a new approach
    • Feiz V., Moshirfar M., Mannis M.J., et al. Nomogram-based intraocular lens power adjustment after myopic photorefractive keratectomy and LASIK; a new approach. Ophthalmology 112 (2005) 1381-1387
    • (2005) Ophthalmology , vol.112 , pp. 1381-1387
    • Feiz, V.1    Moshirfar, M.2    Mannis, M.J.3
  • 41
    • 33646072742 scopus 로고    scopus 로고
    • Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation
    • Masket S., and Masket S.E. Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32 (2006) 430-434
    • (2006) J Cataract Refract Surg , vol.32 , pp. 430-434
    • Masket, S.1    Masket, S.E.2
  • 42
    • 0042828973 scopus 로고    scopus 로고
    • Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis
    • Shammas H.J., Shammas M.C., Garabet A., et al. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol 136 (2003) 426-432
    • (2003) Am J Ophthalmol , vol.136 , pp. 426-432
    • Shammas, H.J.1    Shammas, M.C.2    Garabet, A.3
  • 43
    • 33645920323 scopus 로고    scopus 로고
    • Analysis of intraocular lens power calculation for eyes with previous myopic LASIK
    • Jin G.J.C., Crandall A.S., and Jin Y. Analysis of intraocular lens power calculation for eyes with previous myopic LASIK. J Refract Surg 22 (2006) 387-395
    • (2006) J Refract Surg , vol.22 , pp. 387-395
    • Jin, G.J.C.1    Crandall, A.S.2    Jin, Y.3
  • 44
    • 33646073049 scopus 로고    scopus 로고
    • Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power
    • Walter K.A., Gagnon M.R., Hoopes Jr. P.C., and Dickinson P.J. Accurate intraocular lens power calculation after myopic laser in situ keratomileusis, bypassing corneal power. J Cataract Refract Surg 32 (2006) 425-429
    • (2006) J Cataract Refract Surg , vol.32 , pp. 425-429
    • Walter, K.A.1    Gagnon, M.R.2    Hoopes Jr., P.C.3    Dickinson, P.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.