메뉴 건너뛰기




Volumn 12, Issue 1, 2001, Pages 17-29

Intra-ocular lens calculation status after corneal refractive surgery

Author keywords

[No Author keywords available]

Indexed keywords

CATARACT EXTRACTION; CORNEA SURGERY; EXCIMER LASER; HUMAN; KERATOMETRY; KERATOMILEUSIS; LENS IMPLANT; LENS POWER; PRIORITY JOURNAL; RADIAL KERATOTOMY; REFRACTION ERROR; REVIEW;

EID: 0035147564     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/00055735-200102000-00005     Document Type: Review
Times cited : (95)

References (57)
  • 4
    • 0022683495 scopus 로고
    • Extracapsular cataract extraction with posterior chamber intraocular lens implantation in a postradial keratotomy patient
    • (1986) Arch Ophthalmol , vol.104 , pp. 329-331
    • Markovits, A.S.1
  • 7
    • 8244254369 scopus 로고    scopus 로고
    • Intraocular lens power prediction in patients who undergo cataract surgery following previous radial keratotomy
    • (1997) Arch Ophthalmol , vol.115 , pp. 457-461
    • Lyle, W.A.1    Jin, G.J.2
  • 21
    • 0028820164 scopus 로고
    • Intraocular lens power calculation for eyes after refractive keratotomy
    • (1995) J Refract Surg , vol.11 , pp. 490-493
    • Hoffer, K.J.1
  • 29
    • 85046523870 scopus 로고    scopus 로고
    • Underestimation of intraocular lens power for cataract surgery after myopic PRK
    • (2000) Ophthalmology , vol.107 , pp. 222-223
    • Coulibaly, R.1
  • 40
    • 25944478886 scopus 로고
    • Die Dioptrik des Auges
    • Handbuch der physiologischen Optik, 3.Aufl. Edited by Helmholtz H. Hamburg/Leipzig
    • (1909) , vol.41 , pp. 375
    • Gullstrand, A.1
  • 46
    • 0030828953 scopus 로고    scopus 로고
    • Disparity between keratometry-style readings and corneal power within the pupil after refractive surgery for myopia
    • (1997) Cornea , vol.16 , pp. 517-524
    • Maeda, N.1    Klyce, S.D.2    Smolek, M.K.3
  • 49
    • 0011860165 scopus 로고
    • Contact lens fitting by retinoscopy
    • Contact lenses: Advances in design, fitting, application. Edited by Soper JW. Miami: Symposia specialists
    • (1974)
    • Soper, J.W.1    Goffman, J.2
  • 50
    • 0032992877 scopus 로고    scopus 로고
    • Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity
    • (1999) J Cataract Refract Surg , vol.25 , pp. 898-903
    • Zeh, W.G.1    Koch, D.D.2
  • 54
    • 4243451140 scopus 로고    scopus 로고
    • Ultrasound of optical biometry
    • German Association for IOL Implantation and Refractive Surgery Congress 1999. Edited by Kohnen T, Ohrloff C, Wenzel M. Köln
    • (1999) , pp. 180-186
    • Haigis, W.1    Lege, B.A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.