메뉴 건너뛰기




Volumn 25, Issue 7, 1999, Pages 898-903

Comparison of contact lens overrefraction and standard keratometry for measuring corneal curvature in eyes with lenticular opacity

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CATARACT; CLINICAL ARTICLE; CLINICAL TRIAL; CONTACT LENS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORNEA CURVATURE; DIAGNOSTIC ACCURACY; HUMAN; KERATOMETRY; LENS IMPLANT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 0032992877     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0886-3350(99)00088-7     Document Type: Article
Times cited : (74)

References (9)
  • 1
    • 0024820917 scopus 로고
    • Refractive complications of cataract surgery after radial keratotomy
    • Koch D.D., Liu J.F., Hyde L.L., et al. Refractive complications of cataract surgery after radial keratotomy. Am J Ophthalmol. 108:1989;676-682.
    • (1989) Am J Ophthalmol , vol.108 , pp. 676-682
    • Koch, D.D.1    Liu, J.F.2    Hyde, L.L.3
  • 2
    • 0027317877 scopus 로고
    • When keratometric measurements do not accurately reflect corneal topography
    • Sanders D.R., Gills J.P., Martin R.G. When keratometric measurements do not accurately reflect corneal topography. J Cataract Refract Surg. 19:1993;131-135.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 131-135
    • Sanders, D.R.1    Gills, J.P.2    Martin, R.G.3
  • 3
    • 0028820164 scopus 로고
    • Intraocular lens power calculation for eyes after refractive keratotomy
    • Hoffer K.J. Intraocular lens power calculation for eyes after refractive keratotomy. J Refract Surg. 11:1995;490-493.
    • (1995) J Refract Surg , vol.11 , pp. 490-493
    • Hoffer, K.J.1
  • 4
    • 0028875511 scopus 로고
    • Calculation of intraocular lens power after radial keratotomy with computerized videokeratography
    • Cellikkol L., Pavlopoulos G., Weinstein B., et al. Calculation of intraocular lens power after radial keratotomy with computerized videokeratography. Am J Ophthalmol. 120:1995;739-750.
    • (1995) Am J Ophthalmol , vol.120 , pp. 739-750
    • Cellikkol, L.1    Pavlopoulos, G.2    Weinstein, B.3
  • 5
    • 0001116295 scopus 로고
    • Consultations in refractive surgery
    • Holladay J.T. Consultations in refractive surgery. Refract Corneal Surg. 5:1989;203.
    • (1989) Refract Corneal Surg , vol.5 , pp. 203
    • Holladay, J.T.1
  • 7
    • 0026990947 scopus 로고
    • Sources of error in intraocular lens power calculation
    • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 18:1992;125-129.
    • (1992) J Cataract Refract Surg , vol.18 , pp. 125-129
    • Olsen, T.1
  • 8
    • 0027179635 scopus 로고
    • Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculations
    • Cuaycong M.J., Gay C.A., Emery J., et al. Comparison of the accuracy of computerized videokeratography and keratometry for use in intraocular lens calculations. J Cataract Refract Surg. 19:1993;178-181.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 178-181
    • Cuaycong, M.J.1    Gay, C.A.2    Emery, J.3
  • 9
    • 0029936409 scopus 로고    scopus 로고
    • Computerized videokeratography and keratometry in determining intraocular lens calculations
    • Husain S.E., Kohnen T., Maturi R., et al. Computerized videokeratography and keratometry in determining intraocular lens calculations. J Cataract Refract Surg. 22:1996;362-366.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 362-366
    • Husain, S.E.1    Kohnen, T.2    Maturi, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.