메뉴 건너뛰기




Volumn 18, Issue 1, 2007, Pages 67-73

Optimizing higher-order aberrations with intraocular lens technology

Author keywords

Aspheric intraocular lenses; Optical aberrations; Optical quality; Spherical aberration

Indexed keywords

CONTRAST SENSITIVITY; HUMAN; LENS IMPLANT; LIGHT SCATTERING; MODULATION TRANSFER FUNCTION; POINT SPREAD FUNCTION; PRIORITY JOURNAL; PUPIL; QUALITY CONTROL; REVIEW; SENSITIVITY ANALYSIS; TECHNOLOGY;

EID: 33845617907     PISSN: 10408738     EISSN: None     Source Type: Journal    
DOI: 10.1097/ICU.0b013e3280121af1     Document Type: Review
Times cited : (45)

References (47)
  • 1
    • 0036743484 scopus 로고    scopus 로고
    • Vision Science and its Applications: Standards for reporting the optical aberrations of the eyes
    • VSIA Standards Taskforce Members
    • Thibos LN, Applegate RA, Schwiegerling JT, Webb R. VSIA Standards Taskforce Members. Vision Science and its Applications: Standards for reporting the optical aberrations of the eyes. J Refract Surg 2002; 18:S652-S660.
    • (2002) J Refract Surg , vol.18
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3    Webb, R.4
  • 2
    • 18644375676 scopus 로고    scopus 로고
    • Image metrics for predicting subjective image quality
    • Chen L, Singer B, Guirao A, et al. Image metrics for predicting subjective image quality. Optom Vis Sci 2005; 82:358-369. Spherical aberration had a relevant influence in impairing the subjective view of images, but the total wavefront error and the Strehl ratio were poor predictors of the subjective quality of vision.
    • (2005) Optom Vis Sci , vol.82 , pp. 358-369
    • Chen, L.1    Singer, B.2    Guirao, A.3
  • 3
    • 33745287879 scopus 로고    scopus 로고
    • The Charles W Prentice Award Lecture 2005: Optics of the human eye: progress and problems
    • Charman WN. The Charles W Prentice Award Lecture 2005: optics of the human eye: progress and problems. Optom Vis Sci 2006; 83:335-345.
    • (2006) Optom Vis Sci , vol.83 , pp. 335-345
    • Charman, W.N.1
  • 4
    • 22144437405 scopus 로고    scopus 로고
    • Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye
    • Carvalho LA. Accuracy of Zernike polynomials in characterizing optical aberrations and the corneal surface of the eye. Invest Ophthalmol Vis Sci 2005; 46:1915-1926. Zernike's polynomials up to the sixth order are often not enough to describe aberrated corneal surfaces; therefore, a variable number of polynomials should be considered, according to the specific corneal surface properties and to the desired accuracy.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 1915-1926
    • Carvalho, L.A.1
  • 5
    • 32244435300 scopus 로고    scopus 로고
    • Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces
    • Smolek MK, Klyce SD. Goodness-of-prediction of Zernike polynomial fitting to corneal surfaces. J Cataract Refract Surg 2005; 31:2350-2355. Ten Zernike's orders were necessary to describe the corneal shape down to 0.25-μm accuracy in eyes operated by radial keratotomy. The authors propose a 'precision index' for Zernike analysis of corneal topographies.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2350-2355
    • Smolek, M.K.1    Klyce, S.D.2
  • 6
    • 29544435798 scopus 로고    scopus 로고
    • The shape of the anterior and posterior surface of the aging human cornea
    • Dubbelman M, Sicam VADP, Van der Heijde GL. The shape of the anterior and posterior surface of the aging human cornea. Vision Res 2006; 46:993-1001.
    • (2006) Vision Res , vol.46 , pp. 993-1001
    • Dubbelman, M.1    Sicam, V.A.D.P.2    Van Der Heijde, G.L.3
  • 7
    • 30444444228 scopus 로고    scopus 로고
    • Comparison of higher-order wavefront aberrations with 3 aberrometers
    • Liang CL, Juo SH, Chang CJ. Comparison of higher-order wavefront aberrations with 3 aberrometers. J Cataract Refract Surg 2005; 31:2153-2156.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 2153-2156
    • Liang, C.L.1    Juo, S.H.2    Chang, C.J.3
  • 8
    • 33644689371 scopus 로고    scopus 로고
    • Clinical comparison of 6 aberrometers. Part 2: Statistical comparison in a test group
    • Rozema JJ, Van Dyck DEM, Tassignon M-J. Clinical comparison of 6 aberrometers. Part 2: Statistical comparison in a test group. J Cataract Refract Surg 2006; 32:33-44.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 33-44
    • Rozema, J.J.1    Van Dyck, D.E.M.2    Tassignon, M.-J.3
  • 10
    • 29544432884 scopus 로고    scopus 로고
    • Distribution and enantiomorphism of higher-order ocular optical aberrations
    • Gatinel D, Delair E, Abi-Farah H, Hoang-Xuan T. Distribution and enantiomorphism of higher-order ocular optical aberrations. J Fr Ophtalmol 2005; 28:1041-1050.
    • (2005) J Fr Ophtalmol , vol.28 , pp. 1041-1050
    • Gatinel, D.1    Delair, E.2    Abi-Farah, H.3    Hoang-Xuan, T.4
  • 11
    • 33644550296 scopus 로고    scopus 로고
    • Optics of the average normal cornea from general and canonical representations of its surface topography
    • Navarro R, Gonzalez L, Hernandez JL. Optics of the average normal cornea from general and canonical representations of its surface topography. J Opt Soc Am A 2006; 23:219-232.
    • (2006) J Opt Soc Am A , vol.23 , pp. 219-232
    • Navarro, R.1    Gonzalez, L.2    Hernandez, J.L.3
  • 13
    • 32144464395 scopus 로고    scopus 로고
    • The human eye is an example of robust optical design
    • Artal P, Benito A, Tabernero J. The human eye is an example of robust optical design. J Vision 2006; 6:1-7. This paper describes how the human eye compensates for possible optical errors, including aberrations in general and spherical aberration in particular.
    • (2006) J Vision , vol.6 , pp. 1-7
    • Artal, P.1    Benito, A.2    Tabernero, J.3
  • 14
    • 3042525926 scopus 로고    scopus 로고
    • Predicting subjective judgment of best focus with objective image quality metrics
    • Cheng X, Bradley A, Thibos LN. Predicting subjective judgment of best focus with objective image quality metrics. J Vision 2004; 4:310-321.
    • (2004) J Vision , vol.4 , pp. 310-321
    • Cheng, X.1    Bradley, A.2    Thibos, L.N.3
  • 15
    • 14244264014 scopus 로고    scopus 로고
    • Ocular higher-order aberrations in eyes with supernormal vision
    • Levy Y, Segal O, Avni I, Zadok D. Ocular higher-order aberrations in eyes with supernormal vision. Am J Ophthalmol 2005; 139:225-228. Also this study did not find any relation between total wavefront error and visual acuity better than 20/15. A small amount of positive spherical aberration (0.11 μm) was found in these eyes.
    • (2005) Am J Ophthalmol , vol.139 , pp. 225-228
    • Levy, Y.1    Segal, O.2    Avni, I.3    Zadok, D.4
  • 16
    • 33745284941 scopus 로고    scopus 로고
    • Effect of interactions among wave aberrations on optical image quality
    • McLellan JS, Prieto PM, Marcos S, Burns SA. Effect of interactions among wave aberrations on optical image quality. Vision Res 2006; 46:3009-3016.
    • (2006) Vision Res , vol.46 , pp. 3009-3016
    • McLellan, J.S.1    Prieto, P.M.2    Marcos, S.3    Burns, S.A.4
  • 17
    • 0036884049 scopus 로고    scopus 로고
    • Statistical variation of aberration structure and image quality in a normal population of healthy eyes
    • Thibos LN, Honh X, Bradley A, Cheng X. Statistical variation of aberration structure and image quality in a normal population of healthy eyes. J Opt Soc Am A 2006; 19:2329-2348.
    • (2006) J Opt Soc Am A , vol.19 , pp. 2329-2348
    • Thibos, L.N.1    Honh, X.2    Bradley, A.3    Cheng, X.4
  • 18
    • 0036734697 scopus 로고    scopus 로고
    • Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted
    • Guirao A, Redondo M, Geraghty E, et al. Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted. Arch Ophthalmol 2002; 120:1143-1151.
    • (2002) Arch Ophthalmol , vol.120 , pp. 1143-1151
    • Guirao, A.1    Redondo, M.2    Geraghty, E.3
  • 19
    • 3242772864 scopus 로고    scopus 로고
    • Comparison of wavefront aberrations and optical quality of eyes implanted with five intraocular lenses
    • Bellucci R, Morselli S, Piers P. Comparison of wavefront aberrations and optical quality of eyes implanted with five intraocular lenses. J Refract Surg 2004; 20:297-306.
    • (2004) J Refract Surg , vol.20 , pp. 297-306
    • Bellucci, R.1    Morselli, S.2    Piers, P.3
  • 20
    • 19344373262 scopus 로고    scopus 로고
    • Effect of cataract surgery incision location and intraocular lens type on ocular aberrations
    • Pesudovs K, Dietze H, Stewart OG, et al. Effect of cataract surgery incision location and intraocular lens type on ocular aberrations. J Cataract Refract Surg 2005; 31:725-734. The scleral tunnel with a polymethyl methacrylate intraocular lens led to lower aberrations than corneal incisions with Acrysof intraocular lenses.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 725-734
    • Pesudovs, K.1    Dietze, H.2    Stewart, O.G.3
  • 21
    • 33744942621 scopus 로고    scopus 로고
    • Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses
    • Iseli P, Jankov M, Bueeler M, et al. Corneal and total wavefront aberrations in phakic and pseudophakic eyes after implantation of monofocal foldable intraocular lenses. J Cataract Refract Surg 2006; 32:762-771.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 762-771
    • Iseli, P.1    Jankov, M.2    Bueeler, M.3
  • 22
    • 20544477015 scopus 로고    scopus 로고
    • Influence of intraocular lens optical design on high-order aberrations
    • Taketani F, Yukawa E, Yoshii T, et al. Influence of intraocular lens optical design on high-order aberrations. J Cataract Refract Surg 2005; 31:969-972. The more curved anterior design led to lower aberration measurements than the flatter anterior design.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 969-972
    • Taketani, F.1    Yukawa, E.2    Yoshii, T.3
  • 23
    • 28244499294 scopus 로고    scopus 로고
    • Postoperative wavefront analysys and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs
    • Rocha KM, Chalita MR, Souza CE, et al. Postoperative wavefront analysys and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs. J Refract Surg 2005; 21:S808-S812.
    • (2005) J Refract Surg , vol.21
    • Rocha, K.M.1    Chalita, M.R.2    Souza, C.E.3
  • 24
    • 33645134493 scopus 로고    scopus 로고
    • Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses
    • Padmanabhan P, Yoon G, Porter J, et al. Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses. J Refract Surg 2006; 22:237-242.
    • (2006) J Refract Surg , vol.22 , pp. 237-242
    • Padmanabhan, P.1    Yoon, G.2    Porter, J.3
  • 25
    • 28244479887 scopus 로고    scopus 로고
    • A comparison of higher order aberrations following implantation of four foldable intraocular lens designs
    • Martin RG, Sanders DR. A comparison of higher order aberrations following implantation of four foldable intraocular lens designs. J Refract Surg 2005; 21:716-721. The Acrysof MA60BM intraocular lens was associated with the highest aberrations in this study.
    • (2005) J Refract Surg , vol.21 , pp. 716-721
    • Martin, R.G.1    Sanders, D.R.2
  • 26
    • 33745968295 scopus 로고    scopus 로고
    • Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses: Comparative study
    • Rohart C, Lemarinel B, Thanh HX, Gatinel D. Ocular aberrations after cataract surgery with hydrophobic and hydrophilic acrylic intraocular lenses: comparative study. J Cataract Refract Surg 2006; 32:1201-1205. The hydrophilic acrylic lens was associated with the lower induced aberrations in the implanted eyes.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1201-1205
    • Rohart, C.1    Lemarinel, B.2    Thanh, H.X.3    Gatinel, D.4
  • 27
    • 0036859744 scopus 로고    scopus 로고
    • A new intraocular lens design to reduce spherical aberration of pseudophakic eyes
    • Holladay JT, Piers PA, Koranyi G, et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. J Refract Surg 2002; 18:683-691.
    • (2002) J Refract Surg , vol.18 , pp. 683-691
    • Holladay, J.T.1    Piers, P.A.2    Koranyi, G.3
  • 28
    • 16344378592 scopus 로고    scopus 로고
    • Optical performance of 3 intraocular lens designs in the presence of decentration
    • Altmann GE, Nichamin LD, Lane SS, Pepose JS. Optical performance of 3 intraocular lens designs in the presence of decentration. J Cataract Refract Surg 2005; 31:574-585.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 574-585
    • Altmann, G.E.1    Nichamin, L.D.2    Lane, S.S.3    Pepose, J.S.4
  • 30
    • 0025775401 scopus 로고
    • Design of aspheric intraocular lenses
    • Atchison DA. Design of aspheric intraocular lenses. Ophthalm Physiol Opt 1991; 11:137-146.
    • (1991) Ophthalm Physiol Opt , vol.11 , pp. 137-146
    • Atchison, D.A.1
  • 31
    • 0036859728 scopus 로고    scopus 로고
    • Prospective randomized trial of an anterior surface modified prolate intraocular lens
    • Packer M, Fine IH, Hoffman RS, Piers PA. Prospective randomized trial of an anterior surface modified prolate intraocular lens. J Refract Surg 2002; 18:692-696.
    • (2002) J Refract Surg , vol.18 , pp. 692-696
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3    Piers, P.A.4
  • 32
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: Clinical comparative study
    • Mester U, Dillinger P, Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg 2003; 29:652-660.
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 33
    • 19344374372 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study
    • Bellucci R, Scialdone A, Buratto L, et al. Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study. J Cataract Refract Surg 2005; 31:712-717.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 712-717
    • Bellucci, R.1    Scialdone, A.2    Buratto, L.3
  • 34
    • 18844456295 scopus 로고    scopus 로고
    • Optical quality and depth of field of eyes implanted with spherical and aspheric intraocular lenses
    • Marcos S, Barbero S, Jimenez-Alfaro I. Optical quality and depth of field of eyes implanted with spherical and aspheric intraocular lenses. J Refract Surg 2005; 21:223-235.
    • (2005) J Refract Surg , vol.21 , pp. 223-235
    • Marcos, S.1    Barbero, S.2    Jimenez-Alfaro, I.3
  • 35
    • 33644669989 scopus 로고    scopus 로고
    • Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter
    • Kasper T, Buhren J, Kohnen T. Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter. J Cataract Refract Surg 2006; 32:78-84. The differences in the induced spherical aberration in favour of the aspheric intraocular lenses were evident at any pupil diameter, but the differences in the total higher-order aberrations were found only for pupil diameters of 6 mm.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 78-84
    • Kasper, T.1    Buhren, J.2    Kohnen, T.3
  • 36
    • 33644820379 scopus 로고    scopus 로고
    • Quality of vision after cataract surgery in patients with prolate aspheric lens
    • Denoyer A, Roger F, Majzoub S, Pisella PJ. Quality of vision after cataract surgery in patients with prolate aspheric lens. J Fr Ophtalmol 2006; 29:157-163. The spherical aberration was lower and contrast sensitivity was higher in the eyes implanted with the Tecnis intraocular lens as compared to the eyes with the CeeOn 911 Edge intraocular lens.
    • (2006) J Fr Ophtalmol , vol.29 , pp. 157-163
    • Denoyer, A.1    Roger, F.2    Majzoub, S.3    Pisella, P.J.4
  • 37
    • 33644501101 scopus 로고    scopus 로고
    • Monochromatic aberrations in eyes with different intraocular lens optic designs
    • Padmanabhan P, Rao SK, Jayasree R, et al. Monochromatic aberrations in eyes with different intraocular lens optic designs. J Refract Surg 2006; 22:172-177. Although the Tecnis intraocular lens minimized the spherical aberration in the implanted eyes, no differences in total wavefront aberration were observed in comparison with the Acrysof MA60BM intraocular lens and the AMO AR40e intraocular lens.
    • (2006) J Refract Surg , vol.22 , pp. 172-177
    • Padmanabhan, P.1    Rao, S.K.2    Jayasree, R.3
  • 38
    • 33645986504 scopus 로고    scopus 로고
    • Comparison of the retinal image quality with a Hartmann-Shack sensor and with a double-pass instrument
    • Diaz-Douton F, Benito A, Pujol J, et al. Comparison of the retinal image quality with a Hartmann-Shack sensor and with a double-pass instrument. Invest Ophthalmol Vis Sci 2006; 47:1710-2171. A double-pass instrument taking light scattering into account gives more precise results than an Hartmann-Shack sensor in evaluating the optical quality of eyes with poor transparent optical media.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 1710-2171
    • Diaz-Douton, F.1    Benito, A.2    Pujol, J.3
  • 39
    • 23944443051 scopus 로고    scopus 로고
    • Retinal image quality after microincision intraocular lens implantation
    • Aliò JL, Schimchak P, Montes-Mico R, Galal A. Retinal image quality after microincision intraocular lens implantation. J Cataract Refract Surg 2005; 31:1557-1560. The optical quality of microincision lenses was good on analysis with a double-pass optical analyser.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1557-1560
    • Aliò, J.L.1    Schimchak, P.2    Montes-Mico, R.3    Galal, A.4
  • 40
    • 32044438228 scopus 로고    scopus 로고
    • Evaluation of optical function using a new Point Spread Function analysis system in cataractous and pseudophakic eyes: Preliminary results
    • Negishi K, Kobayashi K, Ohnuma K, et al. Evaluation of optical function using a new Point Spread Function analysis system in cataractous and pseudophakic eyes: preliminary results. Jpn J Ophthalmol 2006; 50:12-19. The PSF analyser based on the double-pass technique can be employed to follow the evolution of the visual impairment due to lens opacification.
    • (2006) Jpn J Ophthalmol , vol.50 , pp. 12-19
    • Negishi, K.1    Kobayashi, K.2    Ohnuma, K.3
  • 42
    • 33646358968 scopus 로고    scopus 로고
    • Imaging quality of intraocular lenses
    • (letter)
    • Norrby S. Imaging quality of intraocular lenses (letter). J Cataract Refract Surg 2006; 32:545-546.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 545-546
    • Norrby, S.1
  • 43
    • 33646346134 scopus 로고    scopus 로고
    • Optomechanical eye model with imaging capabilities for objective evaluation of intraocular lenses
    • Gobbi PG, Fasce F, Bozza S, Brancato R. Optomechanical eye model with imaging capabilities for objective evaluation of intraocular lenses. J Cataract Refract Surg 2006; 32:643-651.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 643-651
    • Gobbi, P.G.1    Fasce, F.2    Bozza, S.3    Brancato, R.4
  • 44
    • 25144506466 scopus 로고    scopus 로고
    • Limitations of correcting spherical aberration with aspheric intraocular lenses
    • Dietze HH, Cox MJ. Limitations of correcting spherical aberration with aspheric intraocular lenses. J Refract Surg 2005; 21:S541-S546. A good review of the current discussion about the limitations of intraocular lenses with negative spherical aberration, represented by the need for patient selection and the effects in case of decentration.
    • (2005) J Refract Surg , vol.21
    • Dietze, H.H.1    Cox, M.J.2
  • 45
    • 4944255688 scopus 로고    scopus 로고
    • Influence of intraocular lens tilt and decentration of wavefront aberrations
    • Taketani F, Matura T, Yukawa E, Yoshiaki H. Influence of intraocular lens tilt and decentration of wavefront aberrations. J Cataract Refract Surg 2004; 30:2158-2162.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2158-2162
    • Taketani, F.1    Matura, T.2    Yukawa, E.3    Yoshiaki, H.4
  • 46
    • 0024396846 scopus 로고
    • Optical design of intraocular lenses. I. On-axis performance
    • Atchison DA. Optical design of intraocular lenses. I. On-axis performance. Optom Vis Sci 1989; 66:671-681.
    • (1989) Optom Vis Sci , vol.66 , pp. 671-681
    • Atchison, D.A.1
  • 47
    • 24944471397 scopus 로고    scopus 로고
    • Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye
    • Wang L, Koch DD. Effect of decentration of wavefront-corrected intraocular lenses on the higher-order aberrations of the eye. Arch Ophthalmol 2005; 123:1226-1230. A confirmation of previous work demonstrating the problems with decentration of aspheric intraocular lenses in experimental conditions.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1226-1230
    • Wang, L.1    Koch, D.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.