-
3
-
-
0015688894
-
Slit-image photography and measurement of the eye
-
N. Brown Slit-image photography and measurement of the eye Medical and Biological Illustration 23 1973 192 203
-
(1973)
Medical and Biological Illustration
, vol.23
, pp. 192-203
-
-
Brown, N.1
-
4
-
-
0018849648
-
Photo-cell device for slit-beam adjustment to the optical axis of the eye in Scheimpflug photography
-
V. Dragomirescu, O. Hockwin, and H. Koch Photo-cell device for slit-beam adjustment to the optical axis of the eye in Scheimpflug photography Ophthalmic Research 12 1980 78 86
-
(1980)
Ophthalmic Research
, vol.12
, pp. 78-86
-
-
Dragomirescu, V.1
Hockwin, O.2
Koch, H.3
-
5
-
-
0035022540
-
The shape of the aging human lens: Curvature equivalent refractive index and the lens paradox
-
M. Dubbelman, and G.L. Van der Heijde The shape of the aging human lens: curvature equivalent refractive index and the lens paradox Vision Research 41 2001 1867 1877
-
(2001)
Vision Research
, vol.41
, pp. 1867-1877
-
-
Dubbelman, M.1
Van Der Heijde, G.L.2
-
6
-
-
9644276888
-
Change in shape of the aging human crystalline lens with accommodation
-
M. Dubbelman, G.L. Van der Heijde, and H.A. Weeber Change in shape of the aging human crystalline lens with accommodation Vision Research 45 2005 117 132
-
(2005)
Vision Research
, vol.45
, pp. 117-132
-
-
Dubbelman, M.1
Van Der Heijde, G.L.2
Weeber, H.A.3
-
7
-
-
0036667901
-
Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography
-
M. Dubbelman, H.A. Weeber, G.L. Van der Heijde, and H.J. Völker-Dieben Radius and asphericity of the posterior corneal surface determined by corrected Scheimpflug photography Acta Ophthalmologica 80 2002 379 383
-
(2002)
Acta Ophthalmologica
, vol.80
, pp. 379-383
-
-
Dubbelman, M.1
Weeber, H.A.2
Van Der Heijde, G.L.3
Völker-Dieben, H.J.4
-
10
-
-
0028918116
-
Topographic determination of corneal asphericity and its lack of effect on the refractive outcome of radial keratotomy
-
F. Eghbali, K.K. Yeung, and R.K. Maloney Topographic determination of corneal asphericity and its lack of effect on the refractive outcome of radial keratotomy American Journal of Ophthalmology 119 1995 275 280
-
(1995)
American Journal of Ophthalmology
, vol.119
, pp. 275-280
-
-
Eghbali, F.1
Yeung, K.K.2
Maloney, R.K.3
-
11
-
-
0036257336
-
Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study
-
T. Eysteinsson, F. Jonasson, H. Sasaki, A. Arnarsson, T. Sverrisson, K. Sasaki, and E. Stefansson Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study Acta Ophthalmologica 80 2002 11 15
-
(2002)
Acta Ophthalmologica
, vol.80
, pp. 11-15
-
-
Eysteinsson, T.1
Jonasson, F.2
Sasaki, H.3
Arnarsson, A.4
Sverrisson, T.5
Sasaki, K.6
Stefansson, E.7
-
12
-
-
0031194743
-
Radius of curvature of the posterior surface of the cornea
-
L.F. Garner, H. Owens, M.K. Yap, M.J. Frith, and R.F. Kinnear Radius of curvature of the posterior surface of the cornea Optometry and Vision Science 74 1997 496 498
-
(1997)
Optometry and Vision Science
, vol.74
, pp. 496-498
-
-
Garner, L.F.1
Owens, H.2
Yap, M.K.3
Frith, M.J.4
Kinnear, R.F.5
-
16
-
-
84950609221
-
The mean shape of the human cornea
-
P.M. Kiely, G. Smith, and L.G. Carney The mean shape of the human cornea Optica Acta 29 1982 1027 1040
-
(1982)
Optica Acta
, vol.29
, pp. 1027-1040
-
-
Kiely, P.M.1
Smith, G.2
Carney, L.G.3
-
18
-
-
0020850433
-
Light distribution on the retina of a wide-angle theoretical eye
-
A.C. Kooijman Light distribution on the retina of a wide-angle theoretical eye Journal of the Optical Society America 73 1983 1544 1550
-
(1983)
Journal of the Optical Society America
, vol.73
, pp. 1544-1550
-
-
Kooijman, A.C.1
-
19
-
-
0030876072
-
Measurement of posterior corneal asphericity on Hong Kong Chinese: A pilot study
-
A.K. Lam, and W.A. Douthwaite Measurement of posterior corneal asphericity on Hong Kong Chinese: a pilot study Ophthalmic and Physiological Optics 17 1997 348 356
-
(1997)
Ophthalmic and Physiological Optics
, vol.17
, pp. 348-356
-
-
Lam, A.K.1
Douthwaite, W.A.2
-
26
-
-
0022655651
-
On the calculation of power from curvature of the cornea
-
T. Olsen On the calculation of power from curvature of the cornea British Journal of Ophthalmology 70 1986 152 154
-
(1986)
British Journal of Ophthalmology
, vol.70
, pp. 152-154
-
-
Olsen, T.1
-
27
-
-
0032769681
-
Measurement of corneal curvature in young and older normal subjects
-
S. Pardhan, and J. Beesley Measurement of corneal curvature in young and older normal subjects Journal of Refractive Surgery 15 1999 469 474
-
(1999)
Journal of Refractive Surgery
, vol.15
, pp. 469-474
-
-
Pardhan, S.1
Beesley, J.2
-
29
-
-
0025153902
-
Measurement of the posterior corneal radius using slit lamp and Purkinje image techniques
-
J.M. Royston, M.C. Dunne, and D.A. Barnes Measurement of the posterior corneal radius using slit lamp and Purkinje image techniques Ophthalmic and Physiological Optics 10 1990 385 388
-
(1990)
Ophthalmic and Physiological Optics
, vol.10
, pp. 385-388
-
-
Royston, J.M.1
Dunne, M.C.2
Barnes, D.A.3
-
30
-
-
14744278223
-
Zentrale und periphere Hornhautpachymetrie, Normevaluation met dem Pentacam-system
-
F. Rüfer, A. Schröder, M.K. Arvani, and C. Erb Zentrale und periphere Hornhautpachymetrie, Normevaluation met dem Pentacam-system Klinische Monatsblätter für die Augenheilkunde 222 2 2005 117 122
-
(2005)
Klinische Monatsblätter für Die Augenheilkunde
, vol.222
, Issue.2
, pp. 117-122
-
-
Rüfer, F.1
Schröder, A.2
Arvani, M.K.3
Erb, C.4
|