메뉴 건너뛰기




Volumn 51, Issue 2, 2006, Pages 158-172

Practical problems with aerosol therapy in COPD

Author keywords

Breath actuated pressurized inhalers; Chronic obstructive pulmonary disease; Dry powder inhaler; Holding chamber; Inhaler; Metered dose inhaler; Nebulizer; Spacer

Indexed keywords

BECLOMETASONE; BUDESONIDE; CICLESONIDE; CORTICOSTEROID; FLUNISOLIDE; FLUTICASONE; FLUTICASONE PROPIONATE PLUS SALMETEROL; FORMOTEROL; FORMOTEROL FUMARATE; HYDROCORTISONE; IPRATROPIUM BROMIDE; LEVALBUTEROL; MOMETASONE; PIRBUTEROL; PIRBUTEROL ACETATE; PREDNISONE; SALBUTAMOL; SALMETEROL; SALMETEROL XINAFOATE; TERBUTALINE; TIOTROPIUM BROMIDE; TRIAMCINOLONE; UNCLASSIFIED DRUG; ZANAMIVIR;

EID: 33748135238     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (166)

References (81)
  • 1
    • 0017141320 scopus 로고
    • The bronchodilator effects of terbutaline: Route of administration and patterns of response
    • Dulfano MJ, Glass P. The bronchodilator effects of terbutaline: route of administration and patterns of response. Ann Allergy 1976;37(5):357-366.
    • (1976) Ann Allergy , vol.37 , Issue.5 , pp. 357-366
    • Dulfano, M.J.1    Glass, P.2
  • 3
    • 1242314344 scopus 로고    scopus 로고
    • Koninck JC, Magro P, Khanjari F, Lemarié E, Diot P. HFA inhalers. Pediatr Pulmonol Suppl 2004;26:23-25.
    • Koninck JC, Magro P, Khanjari F, Lemarié E, Diot P. HFA inhalers. Pediatr Pulmonol Suppl 2004;26:23-25.
  • 4
    • 0032827577 scopus 로고    scopus 로고
    • Advances in metered dose inhaler technology with the development of a chlorofluorocarbon-free drug delivery system
    • Ross DL, Gabrio BJ. Advances in metered dose inhaler technology with the development of a chlorofluorocarbon-free drug delivery system. J Aerosol Med 1999;12(3):151-160.
    • (1999) J Aerosol Med , vol.12 , Issue.3 , pp. 151-160
    • Ross, D.L.1    Gabrio, B.J.2
  • 5
    • 0035035768 scopus 로고    scopus 로고
    • GOLD Scientific Committee. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary
    • Pauwels RA, Buist AS, Calverley PMA, Jenkins CR, Hurd SS. GOLD Scientific Committee. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary. Am J Respir Crit Care Med 2001;163(5):1256-1276.
    • (2001) Am J Respir Crit Care Med , vol.163 , Issue.5 , pp. 1256-1276
    • Pauwels, R.A.1    Buist, A.S.2    Calverley, P.M.A.3    Jenkins, C.R.4    Hurd, S.S.5
  • 6
    • 13544253826 scopus 로고    scopus 로고
    • Device selection and outcomes of aerosol therapy: Evidence-based guidelines. American College of Chest Physicians /American College of Asthma, Allergy, and Immunology
    • Dolovich MB, Ahrens RC, Hess DR, Anderson P, Dhand R, Rau JL, et al. Device selection and outcomes of aerosol therapy: evidence-based guidelines. American College of Chest Physicians /American College of Asthma, Allergy, and Immunology. Chest 2005;127(1):335-371.
    • (2005) Chest , vol.127 , Issue.1 , pp. 335-371
    • Dolovich, M.B.1    Ahrens, R.C.2    Hess, D.R.3    Anderson, P.4    Dhand, R.5    Rau, J.L.6
  • 7
    • 0034763042 scopus 로고    scopus 로고
    • Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: A systematic review of the literature
    • Brocklebank D, Ram F, Wright J, Barry P, Cates C, Davies L, et al. Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature. Health Technol Assess 2001;5(26):1-149.
    • (2001) Health Technol Assess , vol.5 , Issue.26 , pp. 1-149
    • Brocklebank, D.1    Ram, F.2    Wright, J.3    Barry, P.4    Cates, C.5    Davies, L.6
  • 8
    • 0036901803 scopus 로고    scopus 로고
    • Inhaler devices for the treatment of asthma and chronic obstructive airways disease (COPD)
    • Wright J, Brocklebank D, Ram F. Inhaler devices for the treatment of asthma and chronic obstructive airways disease (COPD). Qual Saf Health Care 2002;11(4):376-382.
    • (2002) Qual Saf Health Care , vol.11 , Issue.4 , pp. 376-382
    • Wright, J.1    Brocklebank, D.2    Ram, F.3
  • 10
    • 0035378635 scopus 로고    scopus 로고
    • Asthma and COPD. Inhalation therapy - clarity or confusion?
    • Seeto L, Lim S. Asthma and COPD. Inhalation therapy - clarity or confusion? Aust Fam Physician 2001;30(6):557-561.
    • (2001) Aust Fam Physician , vol.30 , Issue.6 , pp. 557-561
    • Seeto, L.1    Lim, S.2
  • 11
    • 0036178365 scopus 로고    scopus 로고
    • Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
    • Giraud V, Roche N. Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability. Eur Respir J 2002;19(2):246-251.
    • (2002) Eur Respir J , vol.19 , Issue.2 , pp. 246-251
    • Giraud, V.1    Roche, N.2
  • 12
    • 0030722056 scopus 로고    scopus 로고
    • Home nebulized therapy for patients with COPD: Patient compliance with treatment and its relation to quality of life
    • Corden ZM, Bosley CM, Rees PJ, Cochrane GM. Home nebulized therapy for patients with COPD: patient compliance with treatment and its relation to quality of life. Chest 1997;112(5):1278-1282.
    • (1997) Chest , vol.112 , Issue.5 , pp. 1278-1282
    • Corden, Z.M.1    Bosley, C.M.2    Rees, P.J.3    Cochrane, G.M.4
  • 13
    • 29744453224 scopus 로고    scopus 로고
    • Problems with inhaler use: A call for improved clinician and patient education
    • discussion 1374-1375
    • Fink JB, Rubin BK. Problems with inhaler use: a call for improved clinician and patient education. Respir Care 2005;50(10):1360-1374; discussion 1374-1375.
    • (2005) Respir Care , vol.50 , Issue.10 , pp. 1360-1374
    • Fink, J.B.1    Rubin, B.K.2
  • 14
    • 0001576236 scopus 로고
    • Medihaler therapy for bronchial asthma: A new type of aerosol therapy
    • Freedman T. Medihaler therapy for bronchial asthma: a new type of aerosol therapy. Postgrad Med 1956;20(6):667-673.
    • (1956) Postgrad Med , vol.20 , Issue.6 , pp. 667-673
    • Freedman, T.1
  • 15
    • 34249980899 scopus 로고    scopus 로고
    • Thiel CG. From Susie's question to CFC free: an inventor's perspective on forty years of MDI development and regulation. In: Dalby RN, Byron PR, Farr SJ, editors. Respiratory drug delivery, 5th ed. Buffalo Grove, IL: Interpharm Press;1996:115-123
    • Thiel CG. From Susie's question to CFC free: an inventor's perspective on forty years of MDI development and regulation. In: Dalby RN, Byron PR, Farr SJ, editors. Respiratory drug delivery, 5th ed. Buffalo Grove, IL: Interpharm Press;1996:115-123.
  • 16
    • 0000386688 scopus 로고
    • Misuse of inhaled bronchodilator agents
    • Saunders KB. Misuse of inhaled bronchodilator agents. Br Med J 1965;5441:1037-1038.
    • (1965) Br Med J , vol.5441 , pp. 1037-1038
    • Saunders, K.B.1
  • 17
    • 0017169942 scopus 로고
    • Synchronization of bronchodilator release
    • Coady TJ, Stewart CJ, Davies HJ. Synchronization of bronchodilator release. Practitioner 1976;217(1248):273-275.
    • (1976) Practitioner , vol.217 , Issue.1248 , pp. 273-275
    • Coady, T.J.1    Stewart, C.J.2    Davies, H.J.3
  • 18
    • 0017302555 scopus 로고
    • Patient error in use of bronchodilator metered aerosols
    • Orehek J, Gayrard P, Grimaud C, Charpin J. Patient error in use of bronchodilator metered aerosols. Br Med J 1976;1(6001):76.
    • (1976) Br Med J , vol.1 , Issue.6001 , pp. 76
    • Orehek, J.1    Gayrard, P.2    Grimaud, C.3    Charpin, J.4
  • 19
    • 0017231654 scopus 로고
    • Use of pressurised aerosols by asthmatic patients
    • Paterson IC, Crompton GK. Use of pressurised aerosols by asthmatic patients. Br Med J 1976;1(6001):76-77.
    • (1976) Br Med J , vol.1 , Issue.6001 , pp. 76-77
    • Paterson, I.C.1    Crompton, G.K.2
  • 20
    • 0020322578 scopus 로고
    • Problems patients have using pressurized aerosol inhalers
    • Crompton GK. Problems patients have using pressurized aerosol inhalers. Eur J Respir Dis Suppl 1982;119:101-104.
    • (1982) Eur J Respir Dis Suppl , vol.119 , pp. 101-104
    • Crompton, G.K.1
  • 21
    • 0028355136 scopus 로고
    • Misuse of metered-dose inhalers in hospitalized patients
    • Thompson J, Irvine T, Grathwohl K, Roth B. Misuse of metered-dose inhalers in hospitalized patients. Chest 1994;105(3):715-717.
    • (1994) Chest , vol.105 , Issue.3 , pp. 715-717
    • Thompson, J.1    Irvine, T.2    Grathwohl, K.3    Roth, B.4
  • 22
    • 0029116514 scopus 로고
    • Improper patient techniques with metered dose inhalers: Clinical consequences and solutions to misuse
    • McFadden ER Jr. Improper patient techniques with metered dose inhalers: clinical consequences and solutions to misuse. J Allergy Clin Immunol 1995;96(2):278-283.
    • (1995) J Allergy Clin Immunol , vol.96 , Issue.2 , pp. 278-283
    • McFadden Jr., E.R.1
  • 23
    • 0022636609 scopus 로고
    • Effect of InspirEase on the deposition of metered-dose aerosols in the human respiratory tract
    • Newman SP, Woodman G, Clarke SW, Sackner MA. Effect of InspirEase on the deposition of metered-dose aerosols in the human respiratory tract. Chest 1986;89(4):551-556.
    • (1986) Chest , vol.89 , Issue.4 , pp. 551-556
    • Newman, S.P.1    Woodman, G.2    Clarke, S.W.3    Sackner, M.A.4
  • 24
    • 0029595260 scopus 로고
    • How patients determine when to replace their metered-dose inhalers
    • Ogren RA, Baldwin JL, Simon RA. How patients determine when to replace their metered-dose inhalers. Ann Allergy Asthma Immunol 1995;75(6 Pt 1):485-489.
    • (1995) Ann Allergy Asthma Immunol , vol.75 , Issue.6 PART 1 , pp. 485-489
    • Ogren, R.A.1    Baldwin, J.L.2    Simon, R.A.3
  • 25
    • 4544242633 scopus 로고    scopus 로고
    • How do patients determine that their metered-dose inhaler is empty?
    • Rubin BK, Durotoye L. How do patients determine that their metered-dose inhaler is empty? Chest 2004;126(4):1134-1137.
    • (2004) Chest , vol.126 , Issue.4 , pp. 1134-1137
    • Rubin, B.K.1    Durotoye, L.2
  • 26
    • 0029117621 scopus 로고
    • Drug delivery characteristics of metered-dose inhalers
    • Schultz RK. Drug delivery characteristics of metered-dose inhalers. J Allergy Clin Immunol 1995;96(2):284-287.
    • (1995) J Allergy Clin Immunol , vol.96 , Issue.2 , pp. 284-287
    • Schultz, R.K.1
  • 27
    • 0027475604 scopus 로고
    • Metered-dose inhalers. Do health care providers know what to teach?
    • Interiano B, Guntupalli KK. Metered-dose inhalers. Do health care providers know what to teach? Arch Intern Med 1993;153(1):81-85.
    • (1993) Arch Intern Med , vol.153 , Issue.1 , pp. 81-85
    • Interiano, B.1    Guntupalli, K.K.2
  • 28
    • 0026606963 scopus 로고
    • Incorrect use of metered dose inhalers by medical personnel
    • Guidry GG, Brown WD, Stogner SW, George RB. Incorrect use of metered dose inhalers by medical personnel. Chest 1992;101(1):31-33.
    • (1992) Chest , vol.101 , Issue.1 , pp. 31-33
    • Guidry, G.G.1    Brown, W.D.2    Stogner, S.W.3    George, R.B.4
  • 29
    • 0029118979 scopus 로고
    • Metered-dose inhalers: Do emergency health care providers know what to teach?
    • Jones JS, Holstege CP, Riekse R, White L, Bergquist T. Metered-dose inhalers: do emergency health care providers know what to teach? Ann Emerg Med 1995;26(3):308-311.
    • (1995) Ann Emerg Med , vol.26 , Issue.3 , pp. 308-311
    • Jones, J.S.1    Holstege, C.P.2    Riekse, R.3    White, L.4    Bergquist, T.5
  • 30
    • 0027492869 scopus 로고
    • Pharmacist knowledge and ability to use inhaled medication delivery systems
    • Kesten S, Zive K, Chapman KR. Pharmacist knowledge and ability to use inhaled medication delivery systems. Chest 1993;104(6):1737-1742.
    • (1993) Chest , vol.104 , Issue.6 , pp. 1737-1742
    • Kesten, S.1    Zive, K.2    Chapman, K.R.3
  • 32
    • 0036147024 scopus 로고    scopus 로고
    • Ability to learn inhaler technique in relation to cognitive scores and tests of praxis in old age
    • Allen SC, Ragab S. Ability to learn inhaler technique in relation to cognitive scores and tests of praxis in old age. Postgrad Med J 2002;78(915):37-39.
    • (2002) Postgrad Med J , vol.78 , Issue.915 , pp. 37-39
    • Allen, S.C.1    Ragab, S.2
  • 33
    • 0022458123 scopus 로고
    • What determines whether an elderly patient can use a metered dose inhaler correctly?
    • Allen SC, Prior A. What determines whether an elderly patient can use a metered dose inhaler correctly? Br J Dis Chest 1986;80(1):45-49.
    • (1986) Br J Dis Chest , vol.80 , Issue.1 , pp. 45-49
    • Allen, S.C.1    Prior, A.2
  • 34
    • 0024448573 scopus 로고
    • Use and misuse of metered-dose inhalers by patients with chronic lung disease: A controlled, randomized trial of two instruction methods
    • De Blaquiere P, Christensen DB, Carter WB, Martin TR. Use and misuse of metered-dose inhalers by patients with chronic lung disease: a controlled, randomized trial of two instruction methods. Am Rev Respir Dis 1989;140(4):910-916.
    • (1989) Am Rev Respir Dis , vol.140 , Issue.4 , pp. 910-916
    • De Blaquiere, P.1    Christensen, D.B.2    Carter, W.B.3    Martin, T.R.4
  • 36
    • 0019360181 scopus 로고
    • Deposition of pressurized suspension aerosols inhaled through extension devices
    • Newman SP, Morén F, Pavia D, Little F, Clarke SW. Deposition of pressurized suspension aerosols inhaled through extension devices. Am Rev Respir Dis 1981;124(3):317-320.
    • (1981) Am Rev Respir Dis , vol.124 , Issue.3 , pp. 317-320
    • Newman, S.P.1    Morén, F.2    Pavia, D.3    Little, F.4    Clarke, S.W.5
  • 37
    • 0020505452 scopus 로고
    • Clinical evaluation of a simple demand inhalation MDI aerosol delivery device
    • Dolovich M, Ruffin R, Corr D, Newhouse MT. Clinical evaluation of a simple demand inhalation MDI aerosol delivery device. Chest 1983;84(1):36-41.
    • (1983) Chest , vol.84 , Issue.1 , pp. 36-41
    • Dolovich, M.1    Ruffin, R.2    Corr, D.3    Newhouse, M.T.4
  • 38
    • 0029804408 scopus 로고    scopus 로고
    • Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants
    • Wildhaber JH, Devadason SG, Eber E, Hayden MJ, Everard ML, Summers QA, LeSouëf PN. Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants. Thorax 1996;51(10):985-988.
    • (1996) Thorax , vol.51 , Issue.10 , pp. 985-988
    • Wildhaber, J.H.1    Devadason, S.G.2    Eber, E.3    Hayden, M.J.4    Everard, M.L.5    Summers, Q.A.6    LeSouëf, P.N.7
  • 39
    • 0027316392 scopus 로고
    • Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug
    • O'Callaghan C, Lynch J, Cant M, Robertson C. Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug. Thorax 1993;48(6):603-606.
    • (1993) Thorax , vol.48 , Issue.6 , pp. 603-606
    • O'Callaghan, C.1    Lynch, J.2    Cant, M.3    Robertson, C.4
  • 40
    • 0029823099 scopus 로고    scopus 로고
    • Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device
    • Clark DJ, Lipworth BJ. Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device. Thorax 1996;51(10):981-984.
    • (1996) Thorax , vol.51 , Issue.10 , pp. 981-984
    • Clark, D.J.1    Lipworth, B.J.2
  • 41
    • 0029792378 scopus 로고    scopus 로고
    • Electrostatic charge on a plastic spacer device influences the delivery of salbutamol
    • Wildhaber JH, Devadason SG, Hayden MJ, James R, Dufty AP, Fox RA, et al. Electrostatic charge on a plastic spacer device influences the delivery of salbutamol. Eur Respir J 1996;9(9):1943-1946.
    • (1996) Eur Respir J , vol.9 , Issue.9 , pp. 1943-1946
    • Wildhaber, J.H.1    Devadason, S.G.2    Hayden, M.J.3    James, R.4    Dufty, A.P.5    Fox, R.A.6
  • 42
    • 2542509095 scopus 로고    scopus 로고
    • Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery
    • Piérart F, Wildhaber JH, Vrancken I, Devadason SG, Le Souëf PN. Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery. Eur Respir J 1999;13(3):673-678.
    • (1999) Eur Respir J , vol.13 , Issue.3 , pp. 673-678
    • Piérart, F.1    Wildhaber, J.H.2    Vrancken, I.3    Devadason, S.G.4    Le Souëf, P.N.5
  • 43
    • 0031901296 scopus 로고    scopus 로고
    • The effects of static charge in spacer devices on glucocorticosteroid aerosol disposition in asthmatic patients
    • Kenyon CJ, Thorsson L, Borgström L, Newman SP. The effects of static charge in spacer devices on glucocorticosteroid aerosol disposition in asthmatic patients. Eur Respir J 1998;11:606-610.
    • (1998) Eur Respir J , vol.11 , pp. 606-610
    • Kenyon, C.J.1    Thorsson, L.2    Borgström, L.3    Newman, S.P.4
  • 44
    • 34250010267 scopus 로고    scopus 로고
    • Is the use of electrostatic charge-dissipative materials effective as a means of improving aerosol delivery by valved holding chamber (VHC) to the poorly coordinated patient? (abstract)
    • Mitchell JP, Rau JL, Coppolo D, Nagel MW, Avvakoumova VI, Doyle CC, Wiersema KJ. Is the use of electrostatic charge-dissipative materials effective as a means of improving aerosol delivery by valved holding chamber (VHC) to the poorly coordinated patient? (abstract) Proceedings of the American Thoracic Society 2005;Vol 2:A377.
    • (2005) Proceedings of the American Thoracic Society , vol.2
    • Mitchell, J.P.1    Rau, J.L.2    Coppolo, D.3    Nagel, M.W.4    Avvakoumova, V.I.5    Doyle, C.C.6    Wiersema, K.J.7
  • 45
    • 0029958785 scopus 로고    scopus 로고
    • Inhalation of single vs multiple metered-dose bronchodilator actuations from reservoir devices: An in vitro study
    • Rau JL, Restrepo RD, Deshpande V. Inhalation of single vs multiple metered-dose bronchodilator actuations from reservoir devices: an in vitro study. Chest 1996;109(4):969-974.
    • (1996) Chest , vol.109 , Issue.4 , pp. 969-974
    • Rau, J.L.1    Restrepo, R.D.2    Deshpande, V.3
  • 46
    • 0028047817 scopus 로고
    • Medical personnel's knowledge of and ability to use inhaling devices: Metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers
    • Hanania NA, Wittman R, Kesten S, Chapman KR. Medical personnel's knowledge of and ability to use inhaling devices: metered-dose inhalers, spacing chambers, and breath-actuated dry powder inhalers. Chest 1994;105(1):111-116.
    • (1994) Chest , vol.105 , Issue.1 , pp. 111-116
    • Hanania, N.A.1    Wittman, R.2    Kesten, S.3    Chapman, K.R.4
  • 47
    • 0015133119 scopus 로고
    • Dry powder aerosols. I. A new powder inhalation device
    • Bell JH, Hartley PS, Cox JS. Dry powder aerosols. I. A new powder inhalation device. J Pharm Sci 1971;60(10):1559-1564.
    • (1971) J Pharm Sci , vol.60 , Issue.10 , pp. 1559-1564
    • Bell, J.H.1    Hartley, P.S.2    Cox, J.S.3
  • 48
    • 8644222142 scopus 로고    scopus 로고
    • Associazione Italiana Pneumologi Ospedalieri Educational Group. Inhalation technique and variables associated with misuse of conventional metered-dose inhalers and newer dry powder inhalers in experienced adults
    • Melani AS, Zanchetta D, Barbato N, Sestini P, Cinti C, Canessa PA, et al. Associazione Italiana Pneumologi Ospedalieri Educational Group. Inhalation technique and variables associated with misuse of conventional metered-dose inhalers and newer dry powder inhalers in experienced adults. Ann Allergy Asthma Immunol 2004;93(5):439-446.
    • (2004) Ann Allergy Asthma Immunol , vol.93 , Issue.5 , pp. 439-446
    • Melani, A.S.1    Zanchetta, D.2    Barbato, N.3    Sestini, P.4    Cinti, C.5    Canessa, P.A.6
  • 49
    • 0031850061 scopus 로고    scopus 로고
    • Assessment of the inhalation technique in outpatients with asthma or chronic obstructive pulmonary disease using a metered-dose inhaler or dry powder device
    • van Beerendonk I, Mesters I, Mudde AN, Tan TD. Assessment of the inhalation technique in outpatients with asthma or chronic obstructive pulmonary disease using a metered-dose inhaler or dry powder device. J Asthma 1998;35(3):273-279.
    • (1998) J Asthma , vol.35 , Issue.3 , pp. 273-279
    • van Beerendonk, I.1    Mesters, I.2    Mudde, A.N.3    Tan, T.D.4
  • 50
    • 0028811409 scopus 로고
    • Evaluation of the effectiveness of four different inhalers in patients with chronic obstructive pulmonary disease
    • van der Palen J, Klein JJ, Kerkhoff AHM, van Herwaarden CLA. Evaluation of the effectiveness of four different inhalers in patients with chronic obstructive pulmonary disease. Thorax 1995;50(11):1183-1187.
    • (1995) Thorax , vol.50 , Issue.11 , pp. 1183-1187
    • van der Palen, J.1    Klein, J.J.2    Kerkhoff, A.H.M.3    van Herwaarden, C.L.A.4
  • 51
    • 0030668509 scopus 로고    scopus 로고
    • Inhaler use in chronic obstructive pulmonary disease
    • Oliver S, Rees PJ. Inhaler use in chronic obstructive pulmonary disease. Int J Clin Pract 1997;51(7):443-445.
    • (1997) Int J Clin Pract , vol.51 , Issue.7 , pp. 443-445
    • Oliver, S.1    Rees, P.J.2
  • 52
    • 0035835924 scopus 로고    scopus 로고
    • Comparison of elderly people's technique in using two dry powder inhalers to deliver zanamivir: Randomized controlled trial
    • Diggory P, Fernandez C, Humphrey A, Jones V, Murphy M. Comparison of elderly people's technique in using two dry powder inhalers to deliver zanamivir: randomized controlled trial. BMJ 2001;322(7286):577-579.
    • (2001) BMJ , vol.322 , Issue.7286 , pp. 577-579
    • Diggory, P.1    Fernandez, C.2    Humphrey, A.3    Jones, V.4    Murphy, M.5
  • 53
    • 0032933838 scopus 로고    scopus 로고
    • Influence of the moisture on the performance of a new dry powder inhaler
    • Maggi L, Bruni R, Conte U. Influence of the moisture on the performance of a new dry powder inhaler. Int J Pharm 1999;177(1):83-91.
    • (1999) Int J Pharm , vol.177 , Issue.1 , pp. 83-91
    • Maggi, L.1    Bruni, R.2    Conte, U.3
  • 54
    • 0027276653 scopus 로고
    • Effect of exposure to humidity on terbutaline delivery from turbuhaler dry powder inhalation devices (letter)
    • Meakin BJ, Cainey J, Woodcock PM. Effect of exposure to humidity on terbutaline delivery from turbuhaler dry powder inhalation devices (letter). Eur Respir J 1993;6(5):760-761.
    • (1993) Eur Respir J , vol.6 , Issue.5 , pp. 760-761
    • Meakin, B.J.1    Cainey, J.2    Woodcock, P.M.3
  • 55
    • 0028889728 scopus 로고
    • The Diskus: A new multi-dose powder device - efficacy and comparison with Turbuhaler
    • Fuller R. The Diskus: a new multi-dose powder device - efficacy and comparison with Turbuhaler. J Aerosol Med 1995;8(Suppl 2):S11-S17.
    • (1995) J Aerosol Med , vol.8 , Issue.SUPPL. 2
    • Fuller, R.1
  • 57
    • 0034864241 scopus 로고    scopus 로고
    • On the use of dry powder inhalers in situations perceived as constrained
    • Borgström L. On the use of dry powder inhalers in situations perceived as constrained. J Aerosol Med 2001;14(3):281-287.
    • (2001) J Aerosol Med , vol.14 , Issue.3 , pp. 281-287
    • Borgström, L.1
  • 58
    • 0034933441 scopus 로고    scopus 로고
    • Ex-vivo product performance of Diskus and Turbuhaler inhalers using inhalation profiles from patients with severe chronic obstructive pulmonary disease
    • Burnell PKP, Small T, Doig S, Johal B, Jenkins R, Gibson GJ. Ex-vivo product performance of Diskus and Turbuhaler inhalers using inhalation profiles from patients with severe chronic obstructive pulmonary disease. Respir Med 2001;95(5):324-330.
    • (2001) Respir Med , vol.95 , Issue.5 , pp. 324-330
    • Burnell, P.K.P.1    Small, T.2    Doig, S.3    Johal, B.4    Jenkins, R.5    Gibson, G.J.6
  • 59
    • 0025275637 scopus 로고
    • Influence of inspiratory flow rate upon the effect of a Turbuhaler
    • Pedersen S, Hansen OR, Fuglsang G. Influence of inspiratory flow rate upon the effect of a Turbuhaler. Arch Dis Child 1990;65(3):308-310.
    • (1990) Arch Dis Child , vol.65 , Issue.3 , pp. 308-310
    • Pedersen, S.1    Hansen, O.R.2    Fuglsang, G.3
  • 60
    • 0031596530 scopus 로고    scopus 로고
    • Clinical effect of Diskus dry-powder inhaler at low and high inspiratory flow-rates in asthmatic children
    • Nielsen KG, Auk IL, Bojsen K, Ifversen M, Klug B, Bisgaard H. Clinical effect of Diskus dry-powder inhaler at low and high inspiratory flow-rates in asthmatic children. Eur Respir J 1998;11(2):350-354.
    • (1998) Eur Respir J , vol.11 , Issue.2 , pp. 350-354
    • Nielsen, K.G.1    Auk, I.L.2    Bojsen, K.3    Ifversen, M.4    Klug, B.5    Bisgaard, H.6
  • 61
    • 0032921459 scopus 로고    scopus 로고
    • Peak inspiratory flow through Turbuhaler in chronic obstructive airways disease
    • Dewar MH, Jamieson A, McLean A, Crompton GK. Peak inspiratory flow through Turbuhaler in chronic obstructive airways disease. Respir Med 1999;93(5):342-344.
    • (1999) Respir Med , vol.93 , Issue.5 , pp. 342-344
    • Dewar, M.H.1    Jamieson, A.2    McLean, A.3    Crompton, G.K.4
  • 62
    • 8644246755 scopus 로고    scopus 로고
    • The course of inhalation profiles during an exacerbation of obstructive lung disease
    • Broeders ME, Molema J, Hop WC, Vermue NA, Folgering HT. The course of inhalation profiles during an exacerbation of obstructive lung disease. Respir Med 2004;98(12):1173-1179.
    • (2004) Respir Med , vol.98 , Issue.12 , pp. 1173-1179
    • Broeders, M.E.1    Molema, J.2    Hop, W.C.3    Vermue, N.A.4    Folgering, H.T.5
  • 63
    • 0034864138 scopus 로고    scopus 로고
    • Effective delivery of particles with the HandiHaler dry powder inhalation system over a range of chronic obstructive pulmonary disease severity
    • Chodosh S, Flanders JS, Kesten S, Serby CW, Hochrainer D, Witek TJ Jr. Effective delivery of particles with the HandiHaler dry powder inhalation system over a range of chronic obstructive pulmonary disease severity. J Aerosol Med 2001;14(3):309-315.
    • (2001) J Aerosol Med , vol.14 , Issue.3 , pp. 309-315
    • Chodosh, S.1    Flanders, J.S.2    Kesten, S.3    Serby, C.W.4    Hochrainer, D.5    Witek Jr., T.J.6
  • 64
    • 0141837060 scopus 로고    scopus 로고
    • Assessment of patient performance of the HandiHaler compared with the metered dose inhaler four weeks after instruction
    • Dahl R, Backer V, Ollgaard B, Gerken F, Kesten S. Assessment of patient performance of the HandiHaler compared with the metered dose inhaler four weeks after instruction. Respir Med 2003;97(10):1126-1133.
    • (2003) Respir Med , vol.97 , Issue.10 , pp. 1126-1133
    • Dahl, R.1    Backer, V.2    Ollgaard, B.3    Gerken, F.4    Kesten, S.5
  • 65
    • 0032940311 scopus 로고    scopus 로고
    • Comparative efficacy and safety of albuterol sulfate Spiros inhaler and albuterol metered-dose inhaler in asthma
    • Nelson H, Kemp JP, Bieler S, Vaughan LM, Hill MR. Comparative efficacy and safety of albuterol sulfate Spiros inhaler and albuterol metered-dose inhaler in asthma. Chest 1999;115(2):329-335.
    • (1999) Chest , vol.115 , Issue.2 , pp. 329-335
    • Nelson, H.1    Kemp, J.P.2    Bieler, S.3    Vaughan, L.M.4    Hill, M.R.5
  • 66
    • 0029763316 scopus 로고    scopus 로고
    • Medication nebulizer performance. Effects of diluent volume, nebulizer flow, and nebulizer brand
    • Hess D, Fisher D, Williams P, Pooler S, Kacmarek RM. Medication nebulizer performance. Effects of diluent volume, nebulizer flow, and nebulizer brand. Chest 1996;110(2):498-505.
    • (1996) Chest , vol.110 , Issue.2 , pp. 498-505
    • Hess, D.1    Fisher, D.2    Williams, P.3    Pooler, S.4    Kacmarek, R.M.5
  • 67
    • 0022599361 scopus 로고
    • Nebulisers: Uses and abuses (editorial)
    • Newman SP, Clarke SW. Nebulisers: uses and abuses (editorial). Arch Dis Child 1986;61(5):424-425.
    • (1986) Arch Dis Child , vol.61 , Issue.5 , pp. 424-425
    • Newman, S.P.1    Clarke, S.W.2
  • 68
    • 20444429757 scopus 로고    scopus 로고
    • Factors guiding the choice of delivery device for inhaled corticosteroids in the long-term management of stable asthma and COPD: Focus on budesonide
    • Thorsson L, Geller D. Factors guiding the choice of delivery device for inhaled corticosteroids in the long-term management of stable asthma and COPD: focus on budesonide. Respir Med 2005;99(7):836-849.
    • (2005) Respir Med , vol.99 , Issue.7 , pp. 836-849
    • Thorsson, L.1    Geller, D.2
  • 69
    • 0034120751 scopus 로고    scopus 로고
    • Effectiveness and acceptability of a domiciliary multidrug inhalation treatment in elderly patients with chronic airflow obstruction: Metered dose inhaler versus jet nebulizer
    • Balzano G, Battiloro R, Biraghi M, Stefanelli F, Fuschillo S, Gaudiosi C, De Angelis E. Effectiveness and acceptability of a domiciliary multidrug inhalation treatment in elderly patients with chronic airflow obstruction: metered dose inhaler versus jet nebulizer. J Aerosol Med 2000;13(1):25-33.
    • (2000) J Aerosol Med , vol.13 , Issue.1 , pp. 25-33
    • Balzano, G.1    Battiloro, R.2    Biraghi, M.3    Stefanelli, F.4    Fuschillo, S.5    Gaudiosi, C.6    De Angelis, E.7
  • 70
    • 84990454867 scopus 로고
    • Evaluation of a breath actuated pressurized aerosol
    • Coady TJ, Davies HJ, Barnes P. Evaluation of a breath actuated pressurized aerosol. Clin Allergy 1976;6(1):1-6.
    • (1976) Clin Allergy , vol.6 , Issue.1 , pp. 1-6
    • Coady, T.J.1    Davies, H.J.2    Barnes, P.3
  • 71
    • 0026089655 scopus 로고
    • The use of a new beath-actuated inhaler by patients with severe airflow obstruction
    • Fergusson RJ, Lenney J, McHardy GJR, Crompton GK. The use of a new beath-actuated inhaler by patients with severe airflow obstruction. Eur Respir J 1991;4(2):172-174.
    • (1991) Eur Respir J , vol.4 , Issue.2 , pp. 172-174
    • Fergusson, R.J.1    Lenney, J.2    McHardy, G.J.R.3    Crompton, G.K.4
  • 72
    • 0027376998 scopus 로고
    • A comparison of breath-actuated and conventional metered-dose inhaler inhalation techniques in elderly subjects
    • Chapman KR, Love L, Brubaker H. A comparison of breath-actuated and conventional metered-dose inhaler inhalation techniques in elderly subjects. Chest 1993;104(5):1332-1337.
    • (1993) Chest , vol.104 , Issue.5 , pp. 1332-1337
    • Chapman, K.R.1    Love, L.2    Brubaker, H.3
  • 73
    • 0025951893 scopus 로고
    • Improvement of drug delivery with a breath actuated pressurized aerosol for patients with poor inhaler technique
    • Newman SP, Weisz AWB, Talaee N, Clarke SW. Improvement of drug delivery with a breath actuated pressurized aerosol for patients with poor inhaler technique. Thorax 1991;46(10):712-716.
    • (1991) Thorax , vol.46 , Issue.10 , pp. 712-716
    • Newman, S.P.1    Weisz, A.W.B.2    Talaee, N.3    Clarke, S.W.4
  • 74
    • 0034129205 scopus 로고    scopus 로고
    • Inappropriate inhaler use: Assessment of use and patient preference of seven inhalation devices. EDICI
    • Lenney J, Innes JA, Crompton GK. Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices. EDICI. Respir Med 2000;94(5):496-500.
    • (2000) Respir Med , vol.94 , Issue.5 , pp. 496-500
    • Lenney, J.1    Innes, J.A.2    Crompton, G.K.3
  • 75
    • 0036223740 scopus 로고    scopus 로고
    • Mass output and particle size distribution of glucocorticosteroids emitted from different inhalation devices depending on various inspiratory parameters
    • Kamin WES, Genz T, Roeder S, Scheuch G, Trammer T, Juenemann R, Cloes RM. Mass output and particle size distribution of glucocorticosteroids emitted from different inhalation devices depending on various inspiratory parameters. J Aerosol Med 2002;15(1):65-73.
    • (2002) J Aerosol Med , vol.15 , Issue.1 , pp. 65-73
    • Kamin, W.E.S.1    Genz, T.2    Roeder, S.3    Scheuch, G.4    Trammer, T.5    Juenemann, R.6    Cloes, R.M.7
  • 76
    • 22144438721 scopus 로고    scopus 로고
    • Fink JB. Inhalers in asthma management: is demonstration the key to compliance? (editorial) Respir Care 2005;50(5):598-600.
    • Fink JB. Inhalers in asthma management: is demonstration the key to compliance? (editorial) Respir Care 2005;50(5):598-600.
  • 77
    • 27744498750 scopus 로고    scopus 로고
    • Instruction of hospitalized patients by respiratory therapists on metered-dose inhaler use leads to decrease in patient errors
    • Song WS, Mullon J, Regan NA, Roth BJ. Instruction of hospitalized patients by respiratory therapists on metered-dose inhaler use leads to decrease in patient errors. Respir Care 2005;50(8):1040-1045.
    • (2005) Respir Care , vol.50 , Issue.8 , pp. 1040-1045
    • Song, W.S.1    Mullon, J.2    Regan, N.A.3    Roth, B.J.4
  • 78
    • 0036229829 scopus 로고    scopus 로고
    • Inhalation Devices Study Group. Patient perception and acceptability of multidose dry powder inhalers: A randomized crossover comparison of Diskus/Accuhaler with Turbuhaler
    • Serra-Batlles J, Plaza V, Badiola C, Morejón E. Inhalation Devices Study Group. Patient perception and acceptability of multidose dry powder inhalers: a randomized crossover comparison of Diskus/Accuhaler with Turbuhaler. J Aerosol Med 2002;15(1):59-64.
    • (2002) J Aerosol Med , vol.15 , Issue.1 , pp. 59-64
    • Serra-Batlles, J.1    Plaza, V.2    Badiola, C.3    Morejón, E.4
  • 79
    • 2942744348 scopus 로고    scopus 로고
    • Meeting the needs of patients with COPD: Patients' preference for the Diskus inhaler compared with the Handi-Haler
    • Moore AC, Stone S. Meeting the needs of patients with COPD: patients' preference for the Diskus inhaler compared with the Handi-Haler. Int J Clin Pract 2004;58(5):444-450.
    • (2004) Int J Clin Pract , vol.58 , Issue.5 , pp. 444-450
    • Moore, A.C.1    Stone, S.2
  • 80
    • 0032823380 scopus 로고    scopus 로고
    • Targeted delivery of inhaled drugs: Current challenges and future goals
    • Ganderton D. Targeted delivery of inhaled drugs: current challenges and future goals. J Aerosol Med 1999;12 Suppl 1:S3-S8.
    • (1999) J Aerosol Med , vol.12 , Issue.SUPPL. 1
    • Ganderton, D.1
  • 81
    • 0032869779 scopus 로고    scopus 로고
    • New propellant-free technologies under investigation
    • Dolovich M. New propellant-free technologies under investigation. J Aerosol Med 1999;12 Suppl 1:S9-S17.
    • (1999) J Aerosol Med , vol.12 , Issue.SUPPL. 1
    • Dolovich, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.