메뉴 건너뛰기




Volumn 13, Issue 3, 1999, Pages 673-678

Washing plastic spacers in household detergent reduces electrostatic charge and greatly improves delivery

Author keywords

Aerosol therapy; Deposition; Electrostatic charge; Plastic spacers

Indexed keywords

DETERGENT; SALBUTAMOL;

EID: 2542509095     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1183/09031936.99.13367399     Document Type: Article
Times cited : (152)

References (23)
  • 1
    • 0029073833 scopus 로고
    • Factors affecting total and "respirable" dose delivered by a salbutamol metered dose inhaler
    • Everard ML, Devadason SG, Summers QA, Le Souëf PN. Factors affecting total and "respirable" dose delivered by a salbutamol metered dose inhaler. Thorax 1995; 50: 746-749.
    • (1995) Thorax , vol.50 , pp. 746-749
    • Everard, M.L.1    Devadason, S.G.2    Summers, Q.A.3    Le Souëf, P.N.4
  • 2
    • 0038160379 scopus 로고
    • Bronchial asthma, chronic bronchitis and pulmonary parenchymal diseases
    • Moren F, Dolovich MB, Newhouse MT et al., eds. Amsterdam, Elsevier
    • Selroos O. Bronchial asthma, chronic bronchitis and pulmonary parenchymal diseases. In: Moren F, Dolovich MB, Newhouse MT et al., eds. Aerosols in Medicine: Principles, Diagnosis and Therapy. Amsterdam, Elsevier, 1993; pp. 261-289.
    • (1993) Aerosols in Medicine: Principles, Diagnosis and Therapy , pp. 261-289
    • Selroos, O.1
  • 3
    • 0029785420 scopus 로고    scopus 로고
    • Delivery devices for inhaled asthma medication. Clinical implications of differences in effectiveness
    • Selroos O, Pietmalho A, Riska H. Delivery devices for inhaled asthma medication. Clinical implications of differences in effectiveness. Clin Immunother 1996; 6: 273-299.
    • (1996) Clin Immunother , vol.6 , pp. 273-299
    • Selroos, O.1    Pietmalho, A.2    Riska, H.3
  • 4
    • 0026320776 scopus 로고
    • Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler
    • Selroos O, Halme M. Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler. Thorax 1991; 46: 891-894.
    • (1991) Thorax , vol.46 , pp. 891-894
    • Selroos, O.1    Halme, M.2
  • 5
    • 0029787537 scopus 로고    scopus 로고
    • Inhalational drug delivery from seven different spacer devices
    • Barry PW, O'Callaghan C. Inhalational drug delivery from seven different spacer devices. Thorax 1996; 51: 835-840.
    • (1996) Thorax , vol.51 , pp. 835-840
    • Barry, P.W.1    O'Callaghan, C.2
  • 6
    • 0027316392 scopus 로고
    • Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug
    • O'Callaghan C, Lynch J, Cant M, Robertson C. Improvement in sodium cromoglycate delivery from a spacer device by use of an antistatic lining, immediate inhalation, and avoiding multiple actuations of drug. Thorax 1993; 48: 603-606.
    • (1993) Thorax , vol.48 , pp. 603-606
    • O'Callaghan, C.1    Lynch, J.2    Cant, M.3    Robertson, C.4
  • 7
    • 0029070370 scopus 로고
    • The effect of delay, multiple actuations and spacer static charge on the in vitro delivery of budesonide from the Nebuhaler
    • Barry PW, O'Callaghan C. The effect of delay, multiple actuations and spacer static charge on the in vitro delivery of budesonide from the Nebuhaler. Br J Clin Pharmacol 1995; 40: 76-78.
    • (1995) Br J Clin Pharmacol , vol.40 , pp. 76-78
    • Barry, P.W.1    O'Callaghan, C.2
  • 8
    • 0029792378 scopus 로고    scopus 로고
    • Electrostatic charge on a plastic spacer device influences the delivery of salbutamol
    • Wildhaber JH, Devadason SG, Hayden MJ, et al. Electrostatic charge on a plastic spacer device influences the delivery of salbutamol. Eur Respir J 1996; 9: 1943-1946.
    • (1996) Eur Respir J , vol.9 , pp. 1943-1946
    • Wildhaber, J.H.1    Devadason, S.G.2    Hayden, M.J.3
  • 9
    • 0029823099 scopus 로고    scopus 로고
    • Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device
    • Clark DJ, Lipworth BJ. Effect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device. Thorax 1996; 51: 981-984.
    • (1996) Thorax , vol.51 , pp. 981-984
    • Clark, D.J.1    Lipworth, B.J.2
  • 10
    • 0029804408 scopus 로고    scopus 로고
    • Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants
    • Wildhaber JH, Devadason SG, Eber E, et al. Effect of electrostatic charge, flow, delay and multiple actuations on the in vitro delivery of salbutamol from different small volume spacers for infants. Thorax 1996; 51: 985-988.
    • (1996) Thorax , vol.51 , pp. 985-988
    • Wildhaber, J.H.1    Devadason, S.G.2    Eber, E.3
  • 11
    • 0027159864 scopus 로고
    • Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airflow obstruction
    • Melchor R, Biddiscombe MF, Mak VHF, Short MD, Spiro SG. Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airflow obstruction. Thorax 1993; 48: 506-511.
    • (1993) Thorax , vol.48 , pp. 506-511
    • Melchor, R.1    Biddiscombe, M.F.2    Mak, V.H.F.3    Short, M.D.4    Spiro, S.G.5
  • 12
    • 0029863731 scopus 로고    scopus 로고
    • Deposition pattern of radiolabelled salbutamol inhaled from a metered-dose inhaler by means of a spacer with mask in young children with airway obstruction
    • Tal A, Golan H, Grauer N, Aviram M, Albin D, Quastel MR. Deposition pattern of radiolabelled salbutamol inhaled from a metered-dose inhaler by means of a spacer with mask in young children with airway obstruction. J Pediatr 1996; 128: 479-484.
    • (1996) J Pediatr , vol.128 , pp. 479-484
    • Tal, A.1    Golan, H.2    Grauer, N.3    Aviram, M.4    Albin, D.5    Quastel, M.R.6
  • 13
    • 0024433602 scopus 로고
    • Pressurised aerosol deposition in the human lung with and without an "open" spacer device
    • Newman SP, Clark AR, Talaee N, Clarke SW. Pressurised aerosol deposition in the human lung with and without an "open" spacer device. Thorax 1989; 44: 706-710.
    • (1989) Thorax , vol.44 , pp. 706-710
    • Newman, S.P.1    Clark, A.R.2    Talaee, N.3    Clarke, S.W.4
  • 15
    • 0023898690 scopus 로고
    • 2 agonists in the metered dose inhaler with technetium-99m
    • 2 agonists in the metered dose inhaler with technetium-99m. Respiration 1988; 53: 65-73.
    • (1988) Respiration , vol.53 , pp. 65-73
    • Köhler, D.1    Fleischer, W.2    Matthys, H.3
  • 16
    • 0019952520 scopus 로고
    • Absolute quantification of radiotracer uptake in the lungs using a gamma camera
    • Maccy DJ, Marshall R. Absolute quantification of radiotracer uptake in the lungs using a gamma camera. J Nucl Med 1982; 23: 731-734.
    • (1982) J Nucl Med , vol.23 , pp. 731-734
    • Maccy, D.J.1    Marshall, R.2
  • 17
    • 0027389509 scopus 로고
    • Quantification of technetium-99m lung radioactivity from planar images
    • Forge NI, Mountford PJ, O'Doherty MJ. Quantification of technetium-99m lung radioactivity from planar images. Eur J Nucl Med 1993; 20: 10-15.
    • (1993) Eur J Nucl Med , vol.20 , pp. 10-15
    • Forge, N.I.1    Mountford, P.J.2    O'Doherty, M.J.3
  • 18
    • 0025327891 scopus 로고
    • Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution
    • Zainudin BMZ, Biddiscombe M, Tolfree SEJ, Short M, Spiro SG. Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution. Thorax 1990; 45: 469-473.
    • (1990) Thorax , vol.45 , pp. 469-473
    • Zainudin, B.M.Z.1    Biddiscombe, M.2    Tolfree, S.E.J.3    Short, M.4    Spiro, S.G.5
  • 19
    • 0029059091 scopus 로고
    • Aerosol deposition in the human lung following administration from a microprocessor controlled pressurised metered dose inhaler
    • Farr SJ, Rowe AM, Rubsamen R, Taylor G. Aerosol deposition in the human lung following administration from a microprocessor controlled pressurised metered dose inhaler. Thorax 1995; 50: 639-644.
    • (1995) Thorax , vol.50 , pp. 639-644
    • Farr, S.J.1    Rowe, A.M.2    Rubsamen, R.3    Taylor, G.4
  • 20
    • 0020317462 scopus 로고
    • Effects of various inhalation modes on the deposition of radioactive pressurised aerosols
    • Newman SP, Pavia D, Garland N, Clarke SW. Effects of various inhalation modes on the deposition of radioactive pressurised aerosols. Eur J Respir Dis 1982; 63 (Suppl. 119): 57-65.
    • (1982) Eur J Respir Dis , vol.63 , Issue.SUPPL. 119 , pp. 57-65
    • Newman, S.P.1    Pavia, D.2    Garland, N.3    Clarke, S.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.