메뉴 건너뛰기




Volumn 73, Issue 1, 2006, Pages 28-33

Measurement of acetabular polyethylene wear, using a universal measuring microscope, in total hip replacement. Intra- and inter-observer measurement variability;Měřní otěru polyetylenových jamek TEP kyčelního kloubu univerzálním měřicím mikroskopem. Charakteristika měření

Author keywords

Inter observer variability; Intra observer variability; Linear wear; Polyethylene; Total hip arthroplasty; Universal measuring microscope; Volumetric wear; Wear measurement

Indexed keywords

POLYETHYLENE;

EID: 33645353353     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 0030635259 scopus 로고    scopus 로고
    • Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound
    • BERZINS, A., SUMNER, D. R., GALANTE, J. O.: Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound. J. Biomed. Mater. Res., 39: 120-129, 1998.
    • (1998) J. Biomed. Mater. Res. , vol.39 , pp. 120-129
    • Berzins, A.1    Sumner, D.R.2    Galante, J.O.3
  • 2
    • 17644380275 scopus 로고    scopus 로고
    • The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic
    • ČECH, O., DŽUPA, V.: The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic. Acta Chir. orthop. Traum. čech., 72: 57-76, 2005.
    • (2005) Acta Chir. Orthop. Traum. Čech. , vol.72 , pp. 57-76
    • Čech, O.1    Džupa, V.2
  • 3
    • 0031616211 scopus 로고    scopus 로고
    • The estimation of acetabular cup wear volume from two-dimensional measurements: A comprehensive analysis
    • [H]
    • DERBYSHIRE, B.: The estimation of acetabular cup wear volume from two-dimensional measurements: a comprehensive analysis. Proc. Inst. Mech. Eng. [H], 212: 281-291, 1998.
    • (1998) Proc. Inst. Mech. Eng. , vol.212 , pp. 281-291
    • Derbyshire, B.1
  • 4
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • DUMBLETON, J. H., MANLEY, M. T., EDIDIN, A. A.: A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J. Arthroplasty, 17: 649-661, 2002.
    • (2002) J. Arthroplasty , vol.17 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Edidin, A.A.3
  • 6
    • 33645358807 scopus 로고    scopus 로고
    • Měření opotřebení extrahovaných polyetylenových jamek TEP kyčelního kloubu za pomoci univerzálního mikroskopu
    • GALLO, J., HAVRÁNEK, V., HRABOVSKÝ, M.: Měření opotřebení extrahovaných polyetylenových jamek TEP kyčelního kloubu za pomoci univerzálního mikroskopu. Jemná mechanika a optika, 48: 333-338, 2003.
    • (2003) Jemná Mechanika a Optika , vol.48 , pp. 333-338
    • Gallo, J.1    Havránek, V.2    Hrabovský, M.3
  • 8
    • 18444394714 scopus 로고    scopus 로고
    • Přehled statistických metod zpracování dat. Analýza a metaanalýza dat
    • Praha, Portál
    • HENDL, J.: Přehled statistických metod zpracování dat. Analýza a metaanalýza dat. Praha, Portál 2004.
    • (2004)
    • Hendl, J.1
  • 9
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
    • JASTY, M., GOETZ, D. D., BRAGDON, C. R., LEE, K. R., HANSON, A. E., ELDER, J. R., HARRIS, W. H.: Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J. Bone Jt Surg., 79-A: 349-358, 1997.
    • (1997) J. Bone Jt Surg. , vol.79 A , pp. 349-358
    • Jasty, M.1    Goetz, D.D.2    Bragdon, C.R.3    Lee, K.R.4    Hanson, A.E.5    Elder, J.R.6    Harris, W.H.7
  • 10
  • 13
    • 0033972562 scopus 로고    scopus 로고
    • Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components
    • LEWIS, G.: Design issues in clinical studies of the in vivo volumetric wear rate of polyethylene bearing components. J. Bone Jt Surg., 82-A: 281-287, 2000.
    • (2000) J. Bone Jt Surg. , vol.82 A , pp. 281-287
    • Lewis, G.1
  • 14
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • LIVERMORE, J., ILSTRUP, D., MORREY, B.: Effect of femoral head size on wear of the polyethylene acetabular component. J. Bone Jt Surg., 72-A: 518-528, 1990.
    • (1990) J. Bone Jt Surg. , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 15
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • MARTELL, J. M., BERDIA, S.: Determination of polyethylene wear in total hip replacements with use of digital radiographs. J. Bone Jt Surg., 79-A: 1635-1641, 1997.
    • (1997) J. Bone Jt Surg. , vol.79 A , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 16
    • 0038351040 scopus 로고    scopus 로고
    • Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty
    • MARTELL, J. M., BERKSON, E., BERGER, R., JACOBS, J.: Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J. Bone Jt Surg., 85-A: 1111-1117, 2003.
    • (2003) J. Bone Jt Surg. , vol.85 A , pp. 1111-1117
    • Martell, J.M.1    Berkson, E.2    Berger, R.3    Jacobs, J.4
  • 18
    • 0042476688 scopus 로고    scopus 로고
    • Validation of acetabular cup wear volume based on direct and two-dimensional measurements: Hip simulator analysis
    • MIZOUE, T., YAMAMOTO, K., MASAOKA, T., IMAKIIRE, A., AKAGI, M., CLARKE, I. C.: Validation of acetabular cup wear volume based on direct and two-dimensional measurements: hip simulator analysis. J. Orthop. Sci., 8: 491-499, 2003.
    • (2003) J. Orthop. Sci. , vol.8 , pp. 491-499
    • Mizoue, T.1    Yamamoto, K.2    Masaoka, T.3    Imakiire, A.4    Akagi, M.5    Clarke, I.C.6
  • 19
    • 0034487811 scopus 로고    scopus 로고
    • A method for the evaluation of the change in volume of retrieved acetabular cups
    • [H]
    • RAIMONDI, M. T., SASSI, R., PIETRABISSA, R.: A method for the evaluation of the change in volume of retrieved acetabular cups. Proc. Inst. Mech. Eng. [H], 214: 577-587, 2000.
    • (2000) Proc. Inst. Mech. Eng. , vol.214 , pp. 577-587
    • Raimondi, M.T.1    Sassi, R.2    Pietrabissa, R.3
  • 20
    • 0030631656 scopus 로고    scopus 로고
    • An automated method for assessing routine radiographs of patients with total hip replacements
    • [H]
    • REDHEAD, A. L., KOTCHEFF, A. C., TAYLOR, C. J., PORTER, M. L., HUKINS, D. W.: An automated method for assessing routine radiographs of patients with total hip replacements. Proc. Inst. Mech. Eng. [H], 211: 145-154, 1997.
    • (1997) Proc. Inst. Mech. Eng. , vol.211 , pp. 145-154
    • Redhead, A.L.1    Kotcheff, A.C.2    Taylor, C.J.3    Porter, M.L.4    Hukins, D.W.5
  • 21
    • 0032945469 scopus 로고    scopus 로고
    • Wear in total hip and knee replacements
    • SCHMALZRIED, T. P., CALLAGHAN, J. J.: Wear in total hip and knee replacements. J. Bone Jt Surg., 81-A: 115-136, 1999.
    • (1999) J. Bone Jt Surg. , vol.81 A , pp. 115-136
    • Schmalzried, T.P.1    Callaghan, J.J.2
  • 23
    • 0029794815 scopus 로고    scopus 로고
    • Wear of polyethylene cups in total hip arthroplasty. A study of specimens retrieved post mortem
    • SYCHTERZ, C. J., MOON, K. H., HASHIMOTO, Y., TEREFENKO, K. M., ENGH, C. A., JR., BAUER, T. W.: Wear of polyethylene cups in total hip arthroplasty. A study of specimens retrieved post mortem. J. Bone Jt Surg., 78-A: 1193-1200, 1996.
    • (1996) J. Bone Jt Surg. , vol.78 A , pp. 1193-1200
    • Sychterz, C.J.1    Moon, K.H.2    Hashimoto, Y.3    Terefenko, K.M.4    Engh Jr., C.A.5    Bauer, T.W.6
  • 25
    • 0033197866 scopus 로고    scopus 로고
    • Polyethylene wear vector in vivo: A three-dimensional analysis using retrieved acetabular components and radiographs
    • YAMAGUCHI, M., HASHIMOTO, Y., AKISUE, T., BAUER, T. W.: Polyethylene wear vector in vivo: a three-dimensional analysis using retrieved acetabular components and radiographs. J. Orthop. Res., 17: 695-702, 1999.
    • (1999) J. Orthop. Res. , vol.17 , pp. 695-702
    • Yamaguchi, M.1    Hashimoto, Y.2    Akisue, T.3    Bauer, T.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.