메뉴 건너뛰기




Volumn 70, Issue 1, 2003, Pages 6-16

Polyethylene disease;Polyetylenová choroba

Author keywords

Joint arthroplasty; Polyethylene disease; Polyethylene wear

Indexed keywords

FORMALDEHYDE; NITROGEN ACID DERIVATIVE; POLYETHYLENE;

EID: 0038730894     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (39)

References (38)
  • 2
    • 0030017425 scopus 로고    scopus 로고
    • Cellular Biology of Bone-Resorbing Cells
    • ATHANASOU, N.A.: Cellular Biology of Bone-Resorbing Cells. J. Bone Jt Surg., 78-A: 1096-1112, 1996.
    • (1996) J. Bone Jt. Surg. , vol.78 A , pp. 1096-1112
    • Athanasou, N.A.1
  • 3
    • 0032619808 scopus 로고    scopus 로고
    • The Influence of Lubricant on the Morphology of Ultra-High Molecular Weight Polyethylene Wear Debris Generated in Laboratory Tests
    • BESONG, A.A., TIPPER, J.L., MATHEWS, B.J., INGHAM, E., STONE, M.H., FISHER, J.: The Influence of Lubricant on the Morphology of Ultra-High Molecular Weight Polyethylene Wear Debris Generated in Laboratory Tests. Proc. Inst. Mech. Eng., 213: 155-158, 1999.
    • (1999) Proc. Inst. Mech. Eng. , vol.213 , pp. 155-158
    • Besong, A.A.1    Tipper, J.L.2    Mathews, B.J.3    Ingham, E.4    Stone, M.H.5    Fisher, J.6
  • 5
    • 0026346472 scopus 로고
    • Analysis of the Failure of 122 Polyethylene Inserts from Uncemented Tibial Knee Components
    • COLLIER, J.P., MAYOR, M.B., McNAMARA, J.L., SURPRENANT, V.A., JENSEN, R.E.: Analysis of the Failure of 122 Polyethylene Inserts from Uncemented Tibial Knee Components. Clin. Orthop., 273: 232-242, 1991.
    • (1991) Clin. Orthop. , vol.273 , pp. 232-242
    • Collier, J.P.1    Mayor, M.B.2    Mcnamara, J.L.3    Surprenant, V.A.4    Jensen, R.E.5
  • 8
    • 0025260518 scopus 로고
    • Skeletal Tissue Response to Cytokines
    • GOLDRING, M.B., GOLDRING, S.R.: Skeletal Tissue Response to Cytokines. Clin. Orthop., 258: 245-278, 1990.
    • (1990) Clin. Orthop. , vol.258 , pp. 245-278
    • Goldring, M.B.1    Goldring, S.R.2
  • 9
    • 0028283962 scopus 로고
    • T-Lymphocytes Are Not Necessary for Particulate Polyethylene-Induced Macrophage Recruitment. Histologic Studies of the Rat Tibia
    • GOODMAN, S., WANG, J.S., REGULA, D., ASPENBERG, P.: T-Lymphocytes Are Not Necessary for Particulate Polyethylene-Induced Macrophage Recruitment. Histologic Studies of the Rat Tibia. Acta orthop. scand., 65: 157-160, 1994.
    • (1994) Acta Orthop. Scand. , vol.65 , pp. 157-160
    • Goodman, S.1    Wang, J.S.2    Regula, D.3    Aspenberg, P.4
  • 11
    • 0031745101 scopus 로고    scopus 로고
    • Cellular Profile and Cytokine Production at Prosthetic Interfaces. Study of Tissues Retrieved from Revised Hip and Knee Replacements
    • GOODMAN, S.B., HUIE, P., SONG, Y., SCHURMAN, D., MALONEY, W., WOOLSON, S., SIBLEY, R.: Cellular Profile and Cytokine Production at Prosthetic Interfaces. Study of Tissues Retrieved from Revised Hip and Knee Replacements. J. Bone Jt Surg., 80-B: 531-539, 1998.
    • (1998) J. Bone Jt. Surg. , vol.80 B , pp. 531-539
    • Goodman, S.B.1    Huie, P.2    Song, Y.3    Schurman, D.4    Maloney, W.5    Woolson, S.6    Sibley, R.7
  • 12
    • 0034031346 scopus 로고    scopus 로고
    • Reduction of Polyethylene Wear by Concave Dimples on the Frictional Surface in Artificial Hip Joints
    • ITO, H., KANEDA, K., YUHTA, T., NISHIMURA, I., YASUDA, K., MATSUNO, T.: Reduction of Polyethylene Wear by Concave Dimples on the Frictional Surface in Artificial Hip Joints. J. Arthropl., 15: 332-338, 2000.
    • (2000) J. Arthropl. , vol.15 , pp. 332-338
    • Ito, H.1    Kaneda, K.2    Yuhta, T.3    Nishimura, I.4    Yasuda, K.5    Matsuno, T.6
  • 15
    • 0023697318 scopus 로고
    • Wear of Ultra-High-Molecular-Weight Polyethylene Components of 90 Retrieved Knee Prostheses
    • LANDY, M.M., WALKER, P.S.: Wear of Ultra-High-Molecular-Weight Polyethylene Components of 90 Retrieved Knee Prostheses. J. Arthropl., 3-Suppl: S73-85, 1988.
    • (1988) J. Arthropl. , vol.3 , Issue.SUPPL.
    • Landy, M.M.1    Walker, P.S.2
  • 16
    • 0028129938 scopus 로고
    • Ultra-High Molecular Weight Polyethylene. The Material and its Use in Total Joint Implants
    • LI, S., BURSTEIN, A.H.: Ultra-High Molecular Weight Polyethylene. The Material and its Use in Total Joint Implants. J. Bone Jt Surg. 76-A: 1080-1090, 1994.
    • (1994) J. Bone Jt. Surg. , vol.76 A , pp. 1080-1090
    • Li, S.1    Burstein, A.H.2
  • 17
    • 0032773373 scopus 로고    scopus 로고
    • Effect of Protein Lubrication on the Wear Properties of Materials for Prosthetic Joints
    • LIAO, Y.S., BENYA, P.D., McKELLOP, H.A.: Effect of Protein Lubrication on the Wear Properties of Materials for Prosthetic Joints. J. Biomed. Mater. Res., 48: 465-473, 1999.
    • (1999) J. Biomed. Mater. Res. , vol.48 , pp. 465-473
    • Liao, Y.S.1    Benya, P.D.2    Mckellop, H.A.3
  • 18
    • 0029147350 scopus 로고
    • Isolation and Characterization of Wear Particles Generated in Patients Who Have Had Failure of a Hip Arthroplasty Without Cement
    • MALONEY, W.J., SMITH, R.L., SCHMALZRIED, T.P., CHIBA, J., HUENE, D., RUBASH, H.: Isolation and Characterization of Wear Particles Generated in Patients Who Have Had Failure of a Hip Arthroplasty Without Cement. J. Bone Jt Surg., 77-A: 1301-1310, 1995.
    • (1995) J. Bone Jt. Surg. , vol.77 A , pp. 1301-1310
    • Maloney, W.J.1    Smith, R.L.2    Schmalzried, T.P.3    Chiba, J.4    Huene, D.5    Rubash, H.6
  • 19
    • 0033637708 scopus 로고    scopus 로고
    • Effect of Sterilization Method and other Modifications on the Wear Resistance of Acetabular Cups Made of Ultra-High Molecular Weight Polyethylene. A Hip-Simulator Study
    • McKELLOP, H., SHEN, F.W., LU, B., CAMPBELL, P., SALOVEY, R.: Effect of Sterilization Method and other Modifications on the Wear Resistance of Acetabular Cups Made of Ultra-High Molecular Weight Polyethylene. A Hip-Simulator Study. J. Bone Jt Surg., 82-A: 1708-1725, 2000.
    • (2000) J. Bone Jt. Surg. , vol.82 A , pp. 1708-1725
    • Mckellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 21
    • 0031690864 scopus 로고    scopus 로고
    • Quantification of Third-Body Damage and its Effect on Uhmwpe Wear with Different Types of Femoral Head
    • MINAKAWA, H., STONE, M.H., WROBLEWSKI, B.M., LANCASTER, J.G., INGHAM, E., FISHER, J.: Quantification of Third-Body Damage and its Effect on Uhmwpe Wear with Different Types of Femoral Head. J. Bone Jt Surg. , 80-B : 894-899, 1998.
    • (1998) J. Bone Jt. Surg. , vol.80 B , pp. 894-899
    • Minakawa, H.1    Stone, M.H.2    Wroblewski, B.M.3    Lancaster, J.G.4    Ingham, E.5    Fisher, J.6
  • 22
    • 0031887361 scopus 로고    scopus 로고
    • Severe Osteolysis after Third-Body Wear due to Hydroxyapatite Particles from Acetabular Cup Coating
    • MORSCHER, E.W., HEFTI, A., AEBI, U.: Severe Osteolysis after Third-Body Wear due to Hydroxyapatite Particles from Acetabular Cup Coating. J. Bone Jt Surg., 80-B: 267-272, 1998.
    • (1998) J. Bone Jt. Surg. , vol.80 B , pp. 267-272
    • Morscher, E.W.1    Hefti, A.2    Aebi, U.3
  • 23
    • 0035117295 scopus 로고    scopus 로고
    • A Novel Method of Cross-Linking Ultra-High-Molecular-Weight Polyethylene to Improve Wear, Reduce Oxidation, and Retain Mechanical Properties. Recipient of the 1999 Hap Paul Award
    • MURATOGLU, O.K., BRAGDON, C.R., O'CONNOR, D.O., JASTY, M., HARRIS, W.H.: A Novel Method of Cross-Linking Ultra-High-Molecular-Weight Polyethylene to Improve Wear, Reduce Oxidation, and Retain Mechanical Properties. Recipient of the 1999 Hap Paul Award. J. Arthropl., 16: 149-160, 2001.
    • (2001) J. Arthropl. , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 24
    • 0033922311 scopus 로고    scopus 로고
    • Wear of High-Dose Gamma-Irradiated Polyethylene in Total Hip Replacements
    • OONISHI, H. KADOYA, Y.: Wear of High-Dose Gamma-Irradiated Polyethylene in Total Hip Replacements. J. Orthop. Sci., 5: 223-228, 2000.
    • (2000) J. Orthop. Sci. , vol.5 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2
  • 25
    • 0035078816 scopus 로고    scopus 로고
    • Gamma-Irradiated Cross-Linked Polyethylene in Total Hip Replacements- Analysis of Retrieved Sockets after Long-Term Implantation
    • OONISHI, H., KADOYA, Y., MASUDA, S.: Gamma-Irradiated Cross-Linked Polyethylene in Total Hip Replacements- Analysis of Retrieved Sockets after Long-Term Implantation. J. Biomed. Mater. Res., 58: 167-171, 2001.
    • (2001) J. Biomed. Mater. Res. , vol.58 , pp. 167-171
    • Oonishi, H.1    Kadoya, Y.2    Masuda, S.3
  • 26
    • 0001738320 scopus 로고    scopus 로고
    • Gamma Sterilization of Uhmwpe Articular Implants: An Analysis of the Oxidation Problem. Ultra High Molecular Weight Polyethylene
    • PREMNATH, V., HARRIS, W.H., JASTY, M., MERRILL, E.W.: Gamma Sterilization of Uhmwpe Articular Implants: An Analysis of the Oxidation Problem. Ultra High Molecular Weight Polyethylene. Biomaterials, 17: 1741-1753, 1996.
    • (1996) Biomaterials , vol.17 , pp. 1741-1753
    • Premnath, V.1    Harris, W.H.2    Jasty, M.3    Merrill, E.W.4
  • 27
    • 0026662669 scopus 로고
    • Periprosthetic Bone Loss in Total Hip Arthroplasty. Polyethylene Wear Debris and the Concept of the Effective Joint Space
    • SCHMALZRIED, T.P., JASTY, M., HARRIS, W.H.: Periprosthetic Bone Loss in Total Hip Arthroplasty. Polyethylene Wear Debris and the Concept of the Effective Joint Space. J. Bone Jt Surg., 74-A: 849-863, 1992.
    • (1992) J. Bone Jt. Surg. , vol.74 A , pp. 849-863
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 28
    • 0028501856 scopus 로고
    • Polyethylene Wear Debris and Tissue Reactions in Knee as Compared to Hip Replacement Prostheses
    • SCHMALZRIED, T.P., JASTY, M., ROSENBERG, A., HARRIS, W.H.: Polyethylene Wear Debris and Tissue Reactions in Knee as Compared to Hip Replacement Prostheses. J. Appl. Biomater., 5: 185-190, 1994.
    • (1994) J. Appl. Biomater. , vol.5 , pp. 185-190
    • Schmalzried, T.P.1    Jasty, M.2    Rosenberg, A.3    Harris, W.H.4
  • 33
    • 0034114922 scopus 로고    scopus 로고
    • High Macrophage-Colony Stimulating Factor Levels in Synovial Fluid of Loose Artificial Hip Joints
    • TAKEI, I., TAKAGI, M., IDA, H., OGINO, T., SANTAVIRTA, S., KONTTINEN, Y.T.: High Macrophage-Colony Stimulating Factor Levels in Synovial Fluid of Loose Artificial Hip Joints. J. Rheumatol., 27: 894-899, 2000.
    • (2000) J. Rheumatol. , vol.27 , pp. 894-899
    • Takei, I.1    Takagi, M.2    Ida, H.3    Ogino, T.4    Santavirta, S.5    Konttinen, Y.T.6
  • 34
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement
    • URBAN, R.M., JACOBS, J.J., TOMLINSON, M.J., GAVRILOVIC, J., BLACK, J., PEOC'H, M.: Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement. J. Bone Jt Surg., 82-A: 457-476, 2000.
    • (2000) J. Bone Jt. Surg. , vol.82 A , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilovic, J.4    Black, J.5    Peoc'h, M.6
  • 35
    • 0030152397 scopus 로고    scopus 로고
    • Comparison of the Size and Morphology of UHMWPE Wear Debris Produced by a Hip Joint Simulator under Serum and Water Lubricated Conditions
    • WANG, A., ESSNER, A., STARK, C., DUMBLETON, J.H.: Comparison of the Size and Morphology of UHMWPE Wear Debris Produced by a Hip Joint Simulator under Serum and Water Lubricated Conditions. Biomaterials, 17: 865-871, 1996.
    • (1996) Biomaterials , vol.17 , pp. 865-871
    • Wang, A.1    Essner, A.2    Stark, C.3    Dumbleton, J.H.4
  • 36
    • 0032438463 scopus 로고    scopus 로고
    • The Impact of Sterilization Method on Wear in Knee Arthroplasty
    • WILLIAMS, I.R., MAYOR, M.B., COLLIER, J.P.: The Impact of Sterilization Method on Wear in Knee Arthroplasty. Clin. Orthop., 356: 170-180, 1998.
    • (1998) Clin. Orthop. , vol.356 , pp. 170-180
    • Williams, I.R.1    Mayor, M.B.2    Collier, J.P.3
  • 37
    • 0033800360 scopus 로고    scopus 로고
    • Possible Explanation for the White Band Artifact Seen in Clinically Retrieved Polyethylene Tibial Components
    • WILLIE, B.M., GINGELL, D.T., BLOEBAUM, R.D., HOFMANN, A.A.: Possible Explanation for the White Band Artifact Seen in Clinically Retrieved Polyethylene Tibial Components. J. Biomed. Mater. Res., 52: 558-566, 2000.
    • (2000) J. Biomed. Mater. Res. , vol.52 , pp. 558-566
    • Willie, B.M.1    Gingell, D.T.2    Bloebaum, R.D.3    Hofmann, A.A.4
  • 38
    • 0029887658 scopus 로고    scopus 로고
    • Prospective Clinical and Joint Simulator Studies of a New Total Hip Arthroplasty Using Alumina Ceramic Heads and Cross-Linked Polyethylene Cups
    • WROBLEWSKI, B.M., SINEY, P.D., DOWSON, D., COLLINS, S.N.: Prospective Clinical and Joint Simulator Studies of a New Total Hip Arthroplasty Using Alumina Ceramic Heads and Cross-Linked Polyethylene Cups. J. Bone Jt Surg., 78-B: 280-285, 1996.
    • (1996) J. Bone Jt. Surg. , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.