메뉴 건너뛰기




Volumn 39, Issue 1, 1998, Pages 120-129

Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound

Author keywords

Implant retrieval; Polyethylene (UHMWPE); Total hip arthroplasty; Ultrasound; Wear

Indexed keywords

THICKNESS MEASUREMENT; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; ULTRASONIC APPLICATIONS; WEAR OF MATERIALS;

EID: 0030635259     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199801)39:1<120::AID-JBM14>3.0.CO;2-J     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles
    • H. G. Willert, H. Bertram, and G. H. Buchhorn, "Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles," Clin. Orthop., 258, 95-107 (1990).
    • (1990) Clin. Orthop. , vol.258 , pp. 95-107
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 2
    • 0017966550 scopus 로고
    • The appear-ances of wear on polyethylene - A comparison of in vivo and in vitro wear surfaces
    • W. Rostoker, E. Y. S. Chao, and J. O. Galante, "The appear-ances of wear on polyethylene - A comparison of in vivo and in vitro wear surfaces," J. Biomed. Mater. Res., 12, 317-335 (1978).
    • (1978) J. Biomed. Mater. Res. , vol.12 , pp. 317-335
    • Rostoker, W.1    Chao, E.Y.S.2    Galante, J.O.3
  • 6
    • 0029061086 scopus 로고
    • Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups
    • A. Wang, C. Stark, and J. H. Dumbleton, "Role of cyclic plastic deformation in the wear of UHMWPE acetabular cups," J. Biomed. Mater. Res., 29, 619-626 (1995).
    • (1995) J. Biomed. Mater. Res. , vol.29 , pp. 619-626
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3
  • 8
    • 0021673354 scopus 로고
    • Property changes of UHMW polyethylene hip cup endoprostheses during implantation
    • P. Eyerer and Y. C. Ke, "Property changes of UHMW polyethylene hip cup endoprostheses during implantation," J. Biomed. Mater. Res., 18, 1137-1151 (1984).
    • (1984) J. Biomed. Mater. Res. , vol.18 , pp. 1137-1151
    • Eyerer, P.1    Ke, Y.C.2
  • 9
    • 0026202775 scopus 로고
    • Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation
    • M. S. Jahan, C. Wang, G. Schwartz, and J. A. Davidson, "Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation," J. Biomed. Mater. Res., 25, 1005-1017 (1991).
    • (1991) J. Biomed. Mater. Res. , vol.25 , pp. 1005-1017
    • Jahan, M.S.1    Wang, C.2    Schwartz, G.3    Davidson, J.A.4
  • 10
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • J. Livermore, D. Ilstrup, and B. Morrey, "Effect of femoral head size on wear of the polyethylene acetabular component," J. Bone Joint Surg. [Am]., 72-A, 518-528 (1990).
    • (1990) J. Bone Joint Surg. [Am]. , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 11
    • 0028092171 scopus 로고
    • Measurement of polyethylene thickness in total hip arthroplasty
    • A. B. Bankston, M. A. Ritter, E. M. Keating, and P. M. Faris, "Measurement of polyethylene thickness in total hip arthroplasty," J. Arthrop., 9, 533-538 (1994).
    • (1994) J. Arthrop. , vol.9 , pp. 533-538
    • Bankston, A.B.1    Ritter, M.A.2    Keating, E.M.3    Faris, P.M.4
  • 12
    • 0027201038 scopus 로고
    • Socket wear assessment
    • A. Ohlin and G. Selvik, "Socket wear assessment," J. Arthrop., 8, 427-431 (1993).
    • (1993) J. Arthrop. , vol.8 , pp. 427-431
    • Ohlin, A.1    Selvik, G.2
  • 13
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low-friction arthroplasty
    • B. M. Wroblewski, "Direction and rate of socket wear in Charnley low-friction arthroplasty," J. Bone Joint Surg. [Br]., 67-B, 757-761 (1985).
    • (1985) J. Bone Joint Surg. [Br]. , vol.67 B , pp. 757-761
    • Wroblewski, B.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.