메뉴 건너뛰기




Volumn 23, Issue 3, 2006, Pages 273-284

Magnetic resonance brain perfusion imaging with voxel-specific arterial input functions

Author keywords

Blind deconvolution; Dynamic contrast MRI; Local arterial input function; Perfusion weighted imaging; Voxel specific hemodynamic parameters

Indexed keywords

ADULT; ARTERY BLOOD FLOW; ARTERY PERFUSION; ARTICLE; BRAIN ARTERY; BRAIN BLOOD FLOW; BRAIN MAPPING; BRAIN PERFUSION; COMPUTER SIMULATION; CONTRAST ENHANCEMENT; FLOW KINETICS; GRAY MATTER; HEMODYNAMICS; HUMAN; HUMAN EXPERIMENT; MEASUREMENT; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL;

EID: 33644835329     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20505     Document Type: Article
Times cited : (20)

References (40)
  • 1
    • 0036235007 scopus 로고    scopus 로고
    • Which MR-derived perfusion parameters are the best predictors of infarct growth in hyperacute stroke? Comparative study between relative and quantitative measurements
    • Grandin CB, Duprez TP, Smith AM, et al. Which MR-derived perfusion parameters are the best predictors of infarct growth in hyperacute stroke? Comparative study between relative and quantitative measurements. Radiology 2002;223:361-370.
    • (2002) Radiology , vol.223 , pp. 361-370
    • Grandin, C.B.1    Duprez, T.P.2    Smith, A.M.3
  • 2
    • 0036721131 scopus 로고    scopus 로고
    • Using relative cerebral blood flow and volume to evaluate the histopathologic grade of cerebral gliomas: Preliminary results
    • Shin JH, Lee HK, Kwun BD, et al. Using relative cerebral blood flow and volume to evaluate the histopathologic grade of cerebral gliomas: preliminary results. AJR Am J Roentgenol 2002;179:783-789.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 783-789
    • Shin, J.H.1    Lee, H.K.2    Kwun, B.D.3
  • 4
    • 0000174732 scopus 로고    scopus 로고
    • Absolute cerebral blood flow and blood volume measured by magnetic resonance bolus tracking: Comparison with positron emission tomography values
    • Østergaard L, Smith DF, Vestergaard-Poulsen P, et al. Absolute cerebral blood flow and blood volume measured by magnetic resonance bolus tracking: comparison with positron emission tomography values. J Cereb Blood Flow Metab 1998;18:425-432.
    • (1998) J Cereb Blood Flow Metab , vol.18 , pp. 425-432
    • Østergaard, L.1    Smith, D.F.2    Vestergaard-Poulsen, P.3
  • 5
    • 0032852026 scopus 로고    scopus 로고
    • Magnetic resonance perfusion imaging in ischemic heart disease
    • Emmanuelle CP, Marc JF, Didier R. Magnetic resonance perfusion imaging in ischemic heart disease. J Magn Reson Imaging 1999;10:423-433.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 423-433
    • Emmanuelle, C.P.1    Marc, J.F.2    Didier, R.3
  • 6
    • 0032902158 scopus 로고    scopus 로고
    • Hyperacute stroke: Simultaneous measurement of relative cerebral blood volume, relative cerebral blood flow, and mean tissue transit time
    • Sorensen AG, Copen WA, Ostergaard L, et al. Hyperacute stroke: simultaneous measurement of relative cerebral blood volume, relative cerebral blood flow, and mean tissue transit time. Radiology 1999;210:519-527.
    • (1999) Radiology , vol.210 , pp. 519-527
    • Sorensen, A.G.1    Copen, W.A.2    Ostergaard, L.3
  • 7
    • 0036210301 scopus 로고    scopus 로고
    • Intracranial mass lesions: Dynamic contrast-enhanced susceptibility- weighted echo-planar perfusion MR imaging
    • Cha S, Knopp EA, Johnson G, Wetzel SG, Litt AW, Zagzag D. Intracranial mass lesions: dynamic contrast-enhanced susceptibility-weighted echo-planar perfusion MR imaging. Radiology 2002;223:11-29.
    • (2002) Radiology , vol.223 , pp. 11-29
    • Cha, S.1    Knopp, E.A.2    Johnson, G.3    Wetzel, S.G.4    Litt, A.W.5    Zagzag, D.6
  • 8
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke
    • National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. Tissue plasminogen activator for acute ischemic stroke. N Engl J Med 1995;333:1581-1587.
    • (1995) N Engl J Med , vol.333 , pp. 1581-1587
  • 9
    • 0031963837 scopus 로고    scopus 로고
    • Intravenous tissue plasminogen activator for acute ischemic stroke: Feasibility, safety, and efficacy in the first year of clinical practice
    • Chiu D, Krieger D, Villar-Cordova C, et al. Intravenous tissue plasminogen activator for acute ischemic stroke: feasibility, safety, and efficacy in the first year of clinical practice. Stroke 1998;29:18-22.
    • (1998) Stroke , vol.29 , pp. 18-22
    • Chiu, D.1    Krieger, D.2    Villar-Cordova, C.3
  • 10
    • 0029050323 scopus 로고
    • Intravenous thrombolysis with recombinant tissue plasminogen activator for acute hemispheric stroke. The European Cooperative Acute Stroke Study (ECASS)
    • Hacke W, Kaste M, Fieschi C, et al. Intravenous thrombolysis with recombinant tissue plasminogen activator for acute hemispheric stroke. The European Cooperative Acute Stroke Study (ECASS). JAMA 1995;274:1017-1025.
    • (1995) JAMA , vol.274 , pp. 1017-1025
    • Hacke, W.1    Kaste, M.2    Fieschi, C.3
  • 11
    • 0028230438 scopus 로고
    • Cerebral blood volume maps and gliomas: Comparison with tumor grade and histologic findings
    • Aronen HJ, Gazit IE, Louis DN, et al. Cerebral blood volume maps and gliomas: comparison with tumor grade and histologic findings. Radiology 1994;191:41-51.
    • (1994) Radiology , vol.191 , pp. 41-51
    • Aronen, H.J.1    Gazit, I.E.2    Louis, D.N.3
  • 12
    • 13144294020 scopus 로고    scopus 로고
    • Assessment of tumor microcirculation; a new role of dynamic contrast MRI imaging
    • Grieble J, Mayr N, de Vries A, et al. Assessment of tumor microcirculation; a new role of dynamic contrast MRI imaging. J Magn Reson Imaging 1997;7:111-119.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 111-119
    • Grieble, J.1    Mayr, N.2    De Vries, A.3
  • 13
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193,637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gückel, F.5    Lorenz, W.J.6
  • 16
    • 0032989243 scopus 로고    scopus 로고
    • Correction of regional cerebral blood flow measured by stable xenon CT and perfusion MRI
    • Hagen T, Bartylla K, Piepgras U. Correction of regional cerebral blood flow measured by stable xenon CT and perfusion MRI. J Comput Assist Tomogr 1999;23:257-264.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 257-264
    • Hagen, T.1    Bartylla, K.2    Piepgras, U.3
  • 17
    • 0036286107 scopus 로고    scopus 로고
    • Quantitative evaluation of mean transit time obtained with dynamic susceptibility contrast-enhanced MR imaging and with 133Xe SPECT in occlusive cerebrovascular disease
    • Kikuchi K, Murase K, Miki H, et al. Quantitative evaluation of mean transit time obtained with dynamic susceptibility contrast-enhanced MR imaging and with 133Xe SPECT in occlusive cerebrovascular disease. AJR Am J Roentgenol 2002;179:229-235.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 229-235
    • Kikuchi, K.1    Murase, K.2    Miki, H.3
  • 18
    • 0034026245 scopus 로고    scopus 로고
    • Whole brain quantitative CBF and CBV measurements using MRI bolus tracking: Comparison of methodologies
    • Smith AM, Grandin CB, Duprez T, Mataigne F, Cosnard G. Whole brain quantitative CBF and CBV measurements using MRI bolus tracking: comparison of methodologies. Magn Reson Med 2000;43:559-564.
    • (2000) Magn Reson Med , vol.43 , pp. 559-564
    • Smith, A.M.1    Grandin, C.B.2    Duprez, T.3    Mataigne, F.4    Cosnard, G.5
  • 19
    • 0033669002 scopus 로고    scopus 로고
    • Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: A direct comparison with Xe-133 SPECT
    • Wirestam R, Ryding E, Lindgren A, Geijer B, Holtås S, Stålberg F. Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECT. MAGMA 2000;11:96-103.
    • (2000) MAGMA , vol.11 , pp. 96-103
    • Wirestam, R.1    Ryding, E.2    Lindgren, A.3    Geijer, B.4    Holtås, S.5    Stålberg, F.6
  • 20
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part 1: Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part 1: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 21
    • 0036325041 scopus 로고    scopus 로고
    • Perfusion quantification using Gaussian process deconvolution
    • Andersen IK, Szymkowiak A, Rasmussen CE, et al. Perfusion quantification using Gaussian process deconvolution. Magn Reson Med 2002;48:351-361.
    • (2002) Magn Reson Med , vol.48 , pp. 351-361
    • Andersen, I.K.1    Szymkowiak, A.2    Rasmussen, C.E.3
  • 22
    • 0032966087 scopus 로고    scopus 로고
    • Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
    • Vonken EPA, Beekman FJ, Bakker CJG, Viergever MA. Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI. Magn Reson Med 1999;41:343-350.
    • (1999) Magn Reson Med , vol.41 , pp. 343-350
    • Vonken, E.P.A.1    Beekman, F.J.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 23
    • 0034063886 scopus 로고    scopus 로고
    • Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques
    • Wirestam R, Andersson L, Østergaard L, et al. Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques. Magn Reson Med 2000;43:691-700.
    • (2000) Magn Reson Med , vol.43 , pp. 691-700
    • Wirestam, R.1    Andersson, L.2    Østergaard, L.3
  • 24
    • 0037406889 scopus 로고    scopus 로고
    • Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging
    • Carroll TJ, Rowley HA, Haughton VM. Automatic calculation of the arterial input function for cerebral perfusion imaging with MR imaging. Radiology 2003;227:593-600.
    • (2003) Radiology , vol.227 , pp. 593-600
    • Carroll, T.J.1    Rowley, H.A.2    Haughton, V.M.3
  • 25
    • 4744346074 scopus 로고    scopus 로고
    • Defining a local arterial input function for perfusion MRI using independent component analysis
    • Calamante F, Moerup M, Hansen KL. Defining a local arterial input function for perfusion MRI using independent component analysis. Magn Reson Med 2004;52:789-797.
    • (2004) Magn Reson Med , vol.52 , pp. 789-797
    • Calamante, F.1    Moerup, M.2    Hansen, K.L.3
  • 29
    • 0001414496 scopus 로고
    • Applications of homomorphic deconvolution to seismology
    • Ulrych TJ. Applications of homomorphic deconvolution to seismology. Geophysics 1971;36:650-660.
    • (1971) Geophysics , vol.36 , pp. 650-660
    • Ulrych, T.J.1
  • 30
    • 0029342761 scopus 로고
    • Restoration of medical ultrasound images using two-dimensional homomorphic deconvolution
    • Taxt T. Restoration of medical ultrasound images using two-dimensional homomorphic deconvolution. IEEE Trans Ultrason Ferroelectr Freq Contr 1995;42:543-554.
    • (1995) IEEE Trans Ultrason Ferroelectr Freq Contr , vol.42 , pp. 543-554
    • Taxt, T.1
  • 31
    • 0031146548 scopus 로고    scopus 로고
    • Comparison of cepstrum-based methods for radial blind deconvolution of ultrasound images
    • Taxt T. Comparison of cepstrum-based methods for radial blind deconvolution of ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Contr 1997;44:666-674.
    • (1997) IEEE Trans Ultrason Ferroelectr Freq Contr , vol.44 , pp. 666-674
    • Taxt, T.1
  • 32
    • 0028450424 scopus 로고
    • An automated film reader for DNA sequencing based on homomorphic deconvolution
    • Ives JT, Gesteland RF, Stockham TG. An automated film reader for DNA sequencing based on homomorphic deconvolution. IEEE Trans Biomed Eng 1994;41:509-519.
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 509-519
    • Ives, J.T.1    Gesteland, R.F.2    Stockham, T.G.3
  • 33
    • 0000042336 scopus 로고
    • Circulation times and the theory of indicator-dilution methods for determining blood flow and volume
    • Washington, DC: American Physiological Society
    • Zierler KL. Circulation times and the theory of indicator-dilution methods for determining blood flow and volume. In: Handbook of physiology, section 2: circulation. Washington, DC: American Physiological Society; 1962. p 585-615.
    • (1962) Handbook of Physiology, Section 2: Circulation , pp. 585-615
    • Zierler, K.L.1
  • 34
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 36
    • 0018478297 scopus 로고
    • Spectral root homomorphic deconvolution system
    • Lim JS. Spectral root homomorphic deconvolution system. IEEE Trans Acoust Speech Signal Process 1979;27:223-233.
    • (1979) IEEE Trans Acoust Speech Signal Process , vol.27 , pp. 223-233
    • Lim, J.S.1
  • 37
    • 0021513276 scopus 로고
    • Spectral analysis using generalized cepstrum
    • Kobayashi T, Imai S. Spectral analysis using generalized cepstrum. IEEE Trans Acoust 1984;32:1087-1089.
    • (1984) IEEE Trans Acoust , vol.32 , pp. 1087-1089
    • Kobayashi, T.1    Imai, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.