메뉴 건너뛰기




Volumn 52, Issue 4, 2004, Pages 789-797

Defining a local arterial input function for perfusion MRI using independent component analysis

Author keywords

Arterial input function; Deconvolution; Independent component analysis; Perfusion

Indexed keywords

DECONVOLUTION; DIAGNOSIS; MAGNETIC SUSCEPTIBILITY; PATIENT MONITORING;

EID: 4744346074     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20227     Document Type: Article
Times cited : (153)

References (22)
  • 1
    • 0037320944 scopus 로고    scopus 로고
    • Imaging-based decision making in thrombolytic therapy for ischemic stroke: Present status
    • Schellinger PD, Fiebach JB, Hacke W. Imaging-based decision making in thrombolytic therapy for ischemic stroke: present status. Stroke 2003;34:575-583.
    • (2003) Stroke , vol.34 , pp. 575-583
    • Schellinger, P.D.1    Fiebach, J.B.2    Hacke, W.3
  • 3
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Østergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 4
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000;44:466-473.
    • (2000) Magn Reson Med , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 5
    • 0042739012 scopus 로고    scopus 로고
    • Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
    • Calamante F, Yim PJ, Cebral JR. Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics. NeuroImage 2003;19:341-353.
    • (2003) NeuroImage , vol.19 , pp. 341-353
    • Calamante, F.1    Yim, P.J.2    Cebral, J.R.3
  • 7
    • 0037944010 scopus 로고    scopus 로고
    • Defining a local input function for perfusion quantification with bolus contrast MRI
    • Honolulu
    • Alsop D, Wedmid A, Schlaug G. Defining a local input function for perfusion quantification with bolus contrast MRI. In: Proc 10th Annual Meeting ISMRM, Honolulu, 2002. p 659.
    • (2002) Proc 10th Annual Meeting ISMRM , pp. 659
    • Alsop, D.1    Wedmid, A.2    Schlaug, G.3
  • 8
    • 0035108686 scopus 로고    scopus 로고
    • Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI
    • van Osch MJP, Vonken EPA, Bakker CJG, Viergever MA. Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI. Magn Reson Med 2001;45:477-485.
    • (2001) Magn Reson Med , vol.45 , pp. 477-485
    • Van Osch, M.J.P.1    Vonken, E.P.A.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 9
    • 0035181223 scopus 로고    scopus 로고
    • Quantitative measurements of cerebral blood flow in patients with unilateral carotid artery occlusion: A PET and MR study
    • Lin W, Celik A, Derdeyn C, An H, Lee Y, Videen T, Østergaard L, Powers WJ. Quantitative measurements of cerebral blood flow in patients with unilateral carotid artery occlusion: a PET and MR study. J Magn Reson Imag 2001;14:659-667.
    • (2001) J Magn Reson Imag , vol.14 , pp. 659-667
    • Lin, W.1    Celik, A.2    Derdeyn, C.3    An, H.4    Lee, Y.5    Videen, T.6    Østergaard, L.7    Powers, W.J.8
  • 10
    • 0042826822 scopus 로고    scopus 로고
    • Independent component analysis: Algorithms and applications
    • Hyvärinen A, Oja E. Independent component analysis: algorithms and applications. Neural Networks 2000;13:411-430.
    • (2000) Neural Networks , vol.13 , pp. 411-430
    • Hyvärinen, A.1    Oja, E.2
  • 12
    • 0242404415 scopus 로고    scopus 로고
    • Independent component analysis of functional MRI: What is signal and what is noise?
    • McKeown MJ, Hansen LK, Sejnowski TJ. Independent component analysis of functional MRI: What is signal and what is noise? Curr Opin Neurobiol 2003;13:620-629.
    • (2003) Curr Opin Neurobiol , vol.13 , pp. 620-629
    • McKeown, M.J.1    Hansen, L.K.2    Sejnowski, T.J.3
  • 14
    • 0036083756 scopus 로고    scopus 로고
    • Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis
    • Carroll TJ, Haughton VM, Rowley HA, Cordes D. Confounding effect of large vessels on MR perfusion images analyzed with independent component analysis. AJNR Am J Neuroradiol 2002;23:1007-1012.
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 1007-1012
    • Carroll, T.J.1    Haughton, V.M.2    Rowley, H.A.3    Cordes, D.4
  • 15
    • 0013057488 scopus 로고    scopus 로고
    • Signal detection using ICA: Application to chat room topic spotting
    • San Diego
    • Kolenda T, Hansen LK, Larsen J. Signal detection using ICA: application to chat room topic spotting. In: Proc ICA, San Diego, 2001. p 540-545.
    • (2001) Proc ICA , pp. 540-545
    • Kolenda, T.1    Hansen, L.K.2    Larsen, J.3
  • 16
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography
    • Axel L. Cerebral blood flow determination by rapid-sequence computed tomography. Radiology 1980;137:676-686.
    • (1980) Radiology , vol.137 , pp. 676-686
    • Axel, L.1
  • 17
    • 0035739233 scopus 로고    scopus 로고
    • Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging
    • Murase K, Shinohara M, Yamazaki Y. Accuracy of deconvolution analysis based on singular value decomposition for quantification of cerebral blood flow using dynamic susceptibility contrast-enhanced magnetic resonance imaging. Phys Med Biol 2001;46:3147-3159.
    • (2001) Phys Med Biol , vol.46 , pp. 3147-3159
    • Murase, K.1    Shinohara, M.2    Yamazaki, Y.3
  • 20
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation. Theory and experiment
    • Weisskoff RM, Zuo CS, Boxerman JL, Rosen BR. Microscopic susceptibility variation and transverse relaxation. Theory and experiment. Magn Reson Med 1994;31:801-810.
    • (1994) Magn Reson Med , vol.31 , pp. 801-810
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 21
    • 0141498389 scopus 로고    scopus 로고
    • The effect of T2′ changes on spin-echo EPI-derived brain activation maps
    • Honolulu
    • Birn RM, Bandettini PA. The effect of T2′ changes on spin-echo EPI-derived brain activation maps. In: Proc 10th Annual Meeting ISMRM, Honolulu, 2002. p 1324.
    • (2002) Proc 10th Annual Meeting ISMRM , pp. 1324
    • Birn, R.M.1    Bandettini, P.A.2
  • 22
    • 0025773948 scopus 로고
    • Review of the variability of the territories of the major cerebral arteries
    • van der Zwan A, Hillen B. Review of the variability of the territories of the major cerebral arteries. Stroke 1991;22:1078-1084.
    • (1991) Stroke , vol.22 , pp. 1078-1084
    • Van Der Zwan, A.1    Hillen, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.