-
1
-
-
0343081631
-
Origin of pH-glass electrode potentials and development of pNa-responsive glasses
-
Y. Abe, and M. Maeda Origin of pH-glass electrode potentials and development of pNa-responsive glasses J. Electrochem. Soc. 147 2 2000 787 791
-
(2000)
J. Electrochem. Soc.
, vol.147
, Issue.2
, pp. 787-791
-
-
Abe, Y.1
Maeda, M.2
-
2
-
-
0035949835
-
Consecutive microcontact printing - Ligands for asymmetric catalysis in silicon channels
-
H. Andersson, C. Jönsson, C. Moberg, and G. Stemme Consecutive microcontact printing - ligands for asymmetric catalysis in silicon channels Sens. Actuators B 79 2001 78 84
-
(2001)
Sens. Actuators B
, vol.79
, pp. 78-84
-
-
Andersson, H.1
Jönsson, C.2
Moberg, C.3
Stemme, G.4
-
3
-
-
0037096670
-
Micro total analysis systems. 2. Analytical standard operations and applications
-
P.-A. Auroux, D.R. Reyes, D. Iossifidis, and A. Manz Micro total analysis systems. 2. Analytical standard operations and applications Anal. Chem. 74 2002 2637 2652
-
(2002)
Anal. Chem.
, vol.74
, pp. 2637-2652
-
-
Auroux, P.-A.1
Reyes, D.R.2
Iossifidis, D.3
Manz, A.4
-
4
-
-
0034204621
-
Electrochemistry and contact angle measurements on polymer films of ω-(3-pyrrolyl)-alkanoic acids in aqueous solution
-
P.N. Bartlett, M.C. Grossel, and E.M. Barrios Electrochemistry and contact angle measurements on polymer films of ω-(3-pyrrolyl)-alkanoic acids in aqueous solution J. Electroanal. Chem. 487 2000 142 148
-
(2000)
J. Electroanal. Chem.
, vol.487
, pp. 142-148
-
-
Bartlett, P.N.1
Grossel, M.C.2
Barrios, E.M.3
-
5
-
-
0010586286
-
Microtechnologies for pH ISFET chemical sensors
-
C. Cané, I. Gràcia, and A. Merlos Microtechnologies for pH ISFET chemical sensors Microelectron. J. 28 1997 389 405
-
(1997)
Microelectron. J.
, vol.28
, pp. 389-405
-
-
Cané, C.1
Gràcia, I.2
Merlos, A.3
-
6
-
-
0032746841
-
Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays
-
D.C. Duffy, H.L. Gillis, J. Lin, N.F. Sheppard Jr., and G.J. Kellogg Microfabricated centrifugal microfluidic systems: characterization and multiple enzymatic assays Anal. Chem. 71 1999 4669 4698
-
(1999)
Anal. Chem.
, vol.71
, pp. 4669-4698
-
-
Duffy, D.C.1
Gillis, H.L.2
Lin, J.3
Sheppard Jr., N.F.4
Kellogg, G.J.5
-
7
-
-
0036606580
-
An integrated microfabricated cell sorter
-
A.Y. Fu, H.P. Chou, Spence, F.H. Arnold, and S.R. Quake An integrated microfabricated cell sorter Anal. Chem. 74 2002 2451 2457
-
(2002)
Anal. Chem.
, vol.74
, pp. 2451-2457
-
-
Fu, A.Y.1
Chou, H.P.2
Spence3
Arnold, F.H.4
Quake, S.R.5
-
11
-
-
0033827229
-
Recent development and applications of optical and fiber-optic pH sensors
-
L. Jie Recent development and applications of optical and fiber-optic pH sensors Trends Anal. Chem. 19 9 2000 541 552
-
(2000)
Trends Anal. Chem.
, vol.19
, Issue.9
, pp. 541-552
-
-
Jie, L.1
-
12
-
-
7444267914
-
Telemetric electrochemical sensor
-
W.Y. Liao, Y.G. Lee, C.Y. Huang, H.Y. Lin, Y.C. Weng, and T.C. Chou Telemetric electrochemical sensor Biosens. Bioelectron. 20 2004 482 490
-
(2004)
Biosens. Bioelectron.
, vol.20
, pp. 482-490
-
-
Liao, W.Y.1
Lee, Y.G.2
Huang, C.Y.3
Lin, H.Y.4
Weng, Y.C.5
Chou, T.C.6
-
13
-
-
0033997415
-
Response of nanosized cobalt oxide electrodes as pH sensors
-
Q.W. Li, G.A. Luo, and Y.Q. Shu Response of nanosized cobalt oxide electrodes as pH sensors Anal. Chim. Acta 409 2000 137 142
-
(2000)
Anal. Chim. Acta
, vol.409
, pp. 137-142
-
-
Li, Q.W.1
Luo, G.A.2
Shu, Y.Q.3
-
14
-
-
0031677581
-
Partly disposable three-way microvalve for a medical micro total analysis system (μ-TAS)
-
T. Ohori, S. Shoji, K. Miura, and A. Yotsumoto Partly disposable three-way microvalve for a medical micro total analysis system (μ-TAS) Sens. Actuators A 64 1998 57 62
-
(1998)
Sens. Actuators a
, vol.64
, pp. 57-62
-
-
Ohori, T.1
Shoji, S.2
Miura, K.3
Yotsumoto, A.4
-
15
-
-
0037096666
-
Micro total analysis systems. 1. Introduction, theory, and technology
-
D.R. Reyes, D. Iossifidis, P.-A. Auroux, and A. Manz Micro total analysis systems. 1. Introduction, theory, and technology Anal. Chem. 74 2002 2623 2636
-
(2002)
Anal. Chem.
, vol.74
, pp. 2623-2636
-
-
Reyes, D.R.1
Iossifidis, D.2
Auroux, P.-A.3
Manz, A.4
-
16
-
-
2342456343
-
Characterization of a microgravimetric sensor based on pH sensitive hydrogels
-
A. Richter, A. Bund, M. Keller, and K.F. Arndt Characterization of a microgravimetric sensor based on pH sensitive hydrogels Sens. Actuators B 99 2004 579 585
-
(2004)
Sens. Actuators B
, vol.99
, pp. 579-585
-
-
Richter, A.1
Bund, A.2
Keller, M.3
Arndt, K.F.4
-
17
-
-
0025698138
-
Piezoelectric micropump with three valves working peristaltically
-
J.G. Spencer Piezoelectric micropump with three valves working peristaltically Sens. Actuators A 21-23 1990 203 206
-
(1990)
Sens. Actuators a
, vol.21-23
, pp. 203-206
-
-
Spencer, J.G.1
-
18
-
-
0034615958
-
Monolithic microfabricated valves and pumps by multilayer soft lithography
-
M.A. Unger, H.P. Chou, T. Thorsen, A. Scherer, and S.R. Quake Monolithic microfabricated valves and pumps by multilayer soft lithography Science 288 2000 113 116
-
(2000)
Science
, vol.288
, pp. 113-116
-
-
Unger, M.A.1
Chou, H.P.2
Thorsen, T.3
Scherer, A.4
Quake, S.R.5
-
20
-
-
0033170255
-
Sol-gel silica coatings doped with a pH-sensitive chromophore
-
M.A. Villegas, and L. Pascual Sol-gel silica coatings doped with a pH-sensitive chromophore Thin Solid Films 351 1999 103 108
-
(1999)
Thin Solid Films
, vol.351
, pp. 103-108
-
-
Villegas, M.A.1
Pascual, L.2
-
21
-
-
31144447290
-
Automatic bio-sensing diagnostic chips integrated with micro-pumps and micro-valves for multiple disease detection
-
in press.
-
Wang C.H., Lee G.B. Automatic bio-sensing diagnostic chips integrated with micro-pumps and micro-valves for multiple disease detection, Biosens. Bioelectron., in press.
-
Biosens. Bioelectron.
-
-
Wang, C.H.1
Lee, G.B.2
-
22
-
-
14744295455
-
Functionalized platinum(II) terpyridyl alkynyl complexes as colorimetric and luminescence pH sensors
-
K.M.C. Wong, W.S. Tang, X.X. Lu, N.Y. Zhu, and V.W.W. Yam Functionalized platinum(II) terpyridyl alkynyl complexes as colorimetric and luminescence pH sensors Inorg. Chem. 44 2005 1492 1498
-
(2005)
Inorg. Chem.
, vol.44
, pp. 1492-1498
-
-
Wong, K.M.C.1
Tang, W.S.2
Lu, X.X.3
Zhu, N.Y.4
Yam, V.W.W.5
-
23
-
-
0029350360
-
A bidirectional silicon micropump
-
R. Zengerle, J. Ulrich, S. Kluge, M. Richter, and A. Richter A bidirectional silicon micropump Sens. Actuators A 50 1995 81 86
-
(1995)
Sens. Actuators a
, vol.50
, pp. 81-86
-
-
Zengerle, R.1
Ulrich, J.2
Kluge, S.3
Richter, M.4
Richter, A.5
|